Loading...
HomeMy WebLinkAboutEngineering SHUTTER CORPORATION 12980 SE SUZANNE DRIVE. HOBE SOUND, FL 33455 PH: (772)-545-3300 FAX: (772)-545-3297 Property Information Building Information Owner: Lydia Wiseman Wind Zone: 170 MPH. Address: 9413 Scarborough Ct Exposure Category: C Port Saint Lucie,FL 34986 Minimum Building Dimension: 45 ft. Mean Roof Height: 18 ft. Jul Risk Category: 1I Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft)]F Pressure(p.-,f) Pressure(psf) 1 Int 44 69 7 37.4 -40.7 2 Int 44 69 7 37.4 -40.7 3 Int 34 57 7 38.5 -41.8 4 Int 44 69 7 37.4 -40.7 5 Int 44 69 7 37.4 -40.7 6 Int 86 107 7 34.5 -37.9 7 Int 160 110 7 32.9 -36.2 8 End 86 91 7 35.0 -43.9 9 End 44 79• 7 37.0 -48.1 10 Int 44 79 7 37.0 -40.4 11 Int 44 57 7 37.9 -41.2 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.6th Edition(2017)Florida Building Code. Page 1 of 1 MARTIN COUNTY BUILDING DEPARTMENT 900 SE RUHNKE STREET ' STUART,FL 34994 (772)288-5916 FAX(772)288-5911 MARTIN COUNTY BUILDING DEPARTMENT SHUTTERSCHEDULE APPROX. APPROX. HEADER I.D. OPENING APPROX. ANCHOR REINF. NO. SIZE SHUTTER WIDTH HEIGHT SPACING REQ'D. REMARKS (W X H) YES/NO 37"X 63" 45" 71" 12" NO EXAMPLE 1 37x63 44 69 10-9.5 Tapcon Concrete 2 37x63 44 69 10-9.5 Tapcon Concrete 3 26x51 34 57 10 Tapcon Concrete 4 37x63 44 69 10-9.5 Tapcon Concrete 5 37x63 44 69 10-9.5 Tapcon Concrete 6 80x104 86 107 12-12-12-9.5 Tapcon Concrete 7 144x114 160 110 12-12-12-9.5 Tapcon Concrete 8 80x88 86 91 10-12-12-7 Tapcon Concrete 9 4305 44 79 10-12-12-8 Tapcon Concrete 10 4305 44 79 10-12-12-8 Tapcon Concrete 11 37x50 44 57 10 Tapcon Concrete