Loading...
HomeMy WebLinkAboutProduct Approval (2) BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications ? Contact Us BCIS Site Map Links Search I r Florida +Product Approval - I USER:Public User . - T Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail FL# FL298-R5 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GCP Applied Technologies Inc. Address/Phone/Email 62 whitemore ave Cambridge,MA 02140 (617)498-4303 mark.a.franciosi@gcpat.com Authorized Signature Mark Franciosi mark.a.franciosi@gcpat.com Technical Representative Mark A.Franciosi Address/Phone/Email 62 Whittemore Ave Cambridge,MA 02140 (647)498-4303 Mark.A.Franciosi@gcpat.com Quality Assurance Representative Phillip Marcasciano Address/Phone/Email 62 Whittemore Ave Cambridge,MA 02140 (877)423-6491 philip.j.marcasciano@gcpat.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity Benchmark Holdings,L.L.C. Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. F� Validation Checklist-Hardcopy Received Certificate of Independence FL298 R5 COI WRG12001.2 2017 FBC Eval Report GRACE SA Underlavments final.Of Referenced Standard and Year(of Standard) Standard Year ASTM D 1970 2015 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/22/2018 Date Validated 02/22/2018 Date Pending FBC Approval 03/11/2018 Date Approved 06/12/2018 Summary of Products FL# Model,Number or Name Description 298.1 Grace Ice&Water Shield and Grace Self Adhering underlayments for use in steep slope roofing Ice&Water Shield HT Limits of Use Installation Instructions Approved for use in HVHZ: No FL298 R5 II WRG12001.2 2017 FBC Eval Report GRACE SA Approved for use outside HVHZ:Yes Underlavments final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other:See evaluation report of limits of use Evaluation Reports FL298 R5 AE WRG12001.2 2017 FBC Eval Report GRACE SA Underlavments final.pdf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® F:luck M Credit Card Safe I CREEK Certificate of Authorization No.29824 17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: GCP Applied Technologies, Inc. Issued February 22, 2018 62 Whittemore Avenue Cambridge, MA 02140 (617)876-1400 www.gcpat.com Manufacturing Plants: Bedford Park, IL Evanston, IL Mt. Pleasant,TN Drummondville,Quebec Quality Assurance: Benchmark Holdings, LLC(QUA9495) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties REFERENCES Entitv Report No. Standard Year Intertek Testing Services NA(TST1585). 3173292COQ-005B ASTM D 1970 2015a Intertek Testing Services NA(TST1585) 3150841 COQ-003A ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-017-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-018-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-050-02-02 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-141-02-03 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-141-02-04 ASTM D 1970 2015a WRG12001.2 FL298-R5 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK GCP Applied Technologies,Inc. Self-Adhering Underlayments TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND APPLICATION GRACE ICE& Grace Ice&Water Shield'is a high density cross laminated polyethylene surfaced self- WATER SHIELD® adhered ASTM D 1970 underlayment for use on steep slope roofs. GRACE ICE& Grace Ice&Water Shield'HT is a high density cross laminated polyethylene surfaced WATER SHIELD®HT self-adhered ASTM D 1970 Type II underlayment for use on steep slope roofs Deck Type: The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Attachment method: Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions Allowable roof coverings: Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Roof slope limitations shall be in accordance with FBC requirements. 7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 8) The underlayment may be used as described in other current FBC product approval documents. 9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 10) The underlayment shall not be installed over existing roof coverings. 11) Underlayments may be exposed on the roof deck for a maximum duration of 30 days. 12) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. WRG12001.2 FI-298-R5 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. GREEKGCP Applied Technologies,Inc. [� Self-Adhering Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. GAP - RAF- 2018.02.2 • No 74021 �1 - 211 :14:24 )l : 05'00' 0:. STATE OF •:�� Zachary, Florida Reg st atio P.E. 74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT WRG12001.2 FL298-R5 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.