HomeMy WebLinkAboutProduct Approval (2) BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications ? Contact Us BCIS Site Map Links Search
I r Florida
+Product Approval
- I USER:Public User
. -
T
Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail
FL# FL298-R5
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer GCP Applied Technologies Inc.
Address/Phone/Email 62 whitemore ave
Cambridge,MA 02140
(617)498-4303
mark.a.franciosi@gcpat.com
Authorized Signature Mark Franciosi
mark.a.franciosi@gcpat.com
Technical Representative Mark A.Franciosi
Address/Phone/Email 62 Whittemore Ave
Cambridge,MA 02140
(647)498-4303
Mark.A.Franciosi@gcpat.com
Quality Assurance Representative Phillip Marcasciano
Address/Phone/Email 62 Whittemore Ave
Cambridge,MA 02140
(877)423-6491
philip.j.marcasciano@gcpat.com
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity Benchmark Holdings,L.L.C.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
F� Validation Checklist-Hardcopy Received
Certificate of Independence FL298 R5 COI WRG12001.2 2017 FBC Eval Report GRACE SA
Underlavments final.Of
Referenced Standard and Year(of Standard) Standard Year
ASTM D 1970 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/22/2018
Date Validated 02/22/2018
Date Pending FBC Approval 03/11/2018
Date Approved 06/12/2018
Summary of Products
FL# Model,Number or Name Description
298.1 Grace Ice&Water Shield and Grace Self Adhering underlayments for use in steep slope roofing
Ice&Water Shield HT
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL298 R5 II WRG12001.2 2017 FBC Eval Report GRACE SA
Approved for use outside HVHZ:Yes Underlavments final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: N/A Created by Independent Third Party: Yes
Other:See evaluation report of limits of use Evaluation Reports
FL298 R5 AE WRG12001.2 2017 FBC Eval Report GRACE
SA Underlavments final.pdf
Created by Independent Third Party:Yes
Back Next
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
® F:luck M
Credit Card
Safe
I
CREEK Certificate of Authorization No.29824
17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: GCP Applied Technologies, Inc. Issued February 22, 2018
62 Whittemore Avenue
Cambridge, MA 02140
(617)876-1400
www.gcpat.com
Manufacturing Plants: Bedford Park, IL
Evanston, IL
Mt. Pleasant,TN
Drummondville,Quebec
Quality Assurance: Benchmark Holdings, LLC(QUA9495)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
REFERENCES
Entitv Report No. Standard Year
Intertek Testing Services NA(TST1585). 3173292COQ-005B ASTM D 1970 2015a
Intertek Testing Services NA(TST1585) 3150841 COQ-003A ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-017-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-018-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-050-02-02 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-141-02-03 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-141-02-04 ASTM D 1970 2015a
WRG12001.2 FL298-R5 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK GCP Applied Technologies,Inc.
Self-Adhering Underlayments
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND APPLICATION
GRACE ICE& Grace Ice&Water Shield'is a high density cross laminated polyethylene surfaced self-
WATER SHIELD® adhered ASTM D 1970 underlayment for use on steep slope roofs.
GRACE ICE& Grace Ice&Water Shield'HT is a high density cross laminated polyethylene surfaced
WATER SHIELD®HT self-adhered ASTM D 1970 Type II underlayment for use on steep slope roofs
Deck Type: The roof deck shall be constructed of closely fitted
sheathing for new or existing construction.
Sheathing shall be installed in accordance with FBC
requirements. Roof decks shall have no more than
1/8"gap at abutting joints.
Attachment method: Underlayment shall be attached in accordance with
the FBC Table 1507.1.1 and manufacturer's
installation instructions
Allowable roof coverings: Mechanically attached roof systems as prescribed in
FBC Section 1507.1.1.
LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Roof slope limitations shall be in accordance with FBC requirements.
7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps
shall be staggered between courses in accordance with the manufacturer's application instructions.
8) The underlayment may be used as described in other current FBC product approval documents.
9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
10) The underlayment shall not be installed over existing roof coverings.
11) Underlayments may be exposed on the roof deck for a maximum duration of 30 days.
12) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
WRG12001.2 FI-298-R5 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.
GREEKGCP Applied Technologies,Inc.
[� Self-Adhering Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6th Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
GAP - RAF- 2018.02.2
• No 74021 �1
- 211 :14:24
)l : 05'00'
0:. STATE OF •:��
Zachary, Florida Reg st atio P.E.
74021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have,nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
WRG12001.2 FL298-R5 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not
specifically addressed herein.