Form Title: Validation checklist for evaluation report from an architect or engineer
Form#: 9N-3.011(3)(c)
Administrative Validation
1. Verify the evaluator is a Florida Registered Architect or Florida Professional Engineer
who has taken the core building code course.
2. Verify submission of the evaluator's certification of independence.
G 3. If the evaluation is not performed by a third party independent of the manufacturer
then verify validator's certificate of independence.
W 4. Verify the evaluation report is for the products listed on the application as described on
the application and that the products are within the scope of Rule 9B-72.
[ 5. Verify that test reports demonstrating compliance were performed at a test lab
accredited by an approved accreditation body for the test performed,and verify test
lab location.
Cj 6. Verify that the test reports or rational analysis are required by the Building Code as a
component of a product approval for the product category and subcategory.
7. Verify that rational analysis demonstrating performance were executed utilizing current
code requirements and was not used in lieu of a standardized test required by the
Code or that rational analysis was not required.
8. Verify that all data,test reports and calculations,are substantiated on the report.
EZ 9. Verify that the application has the Code sections and reference standards for which the
evaluation demonstrates compliance.
Wj 10. Verify the method of demonstrating compliance indicate any limitations on the use of
the product,as intended.
LZ 11. Verify the manufacturer installation Instructions are in accordance with the evaluation
report,and attachments are provided.
Q 12. Verify that a quality assurance program audited by a Florida Building Commission
approved third party quality assurance agency is in place.
To the best of my/our knowledge,this application is complete,the Items in the
checklist above have been verified and reviewed,and the evaluation report submitted
with this application indicates that the product,method,or system described in this
application meets or exceeds the Florida Building Code requirements and reference
standards listed in the application.
Back Plext
Contact Us::2601 Blair Stone Road.Tallahassee FI 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
® E
Credit Card
Safe
CREEK
Certificate of Authorization No.29824
17520 Edinburgh Drive
Tampa,FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017)
Manufacturer: GCP Applied Technologies, Inc. Issued February 22, 2018
62 Whittemore Avenue
Cambridge, MA 02140
(617)876-1400
www.gcpat.com
Manufacturing Plants: Bedford Park, IL
Evanston, IL
Mt. Pleasant,TN
Drummondville,Quebec
Quality Assurance: Benchmark Holdings, LLC(QUA9495)
Ili
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
REFERENCES
Entity Report No. Standard Year
Intertek Testing Services NA(TST1585) 3173292COQ-0058 ASTM D 1970 2015a
Intertek Testing Services NA(TST1585) 3150841 COQ-003A ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-017-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-018-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-050-02-02 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-141-02-03 ASTM D 1970 2015a
PRI Construction Materials Technologies(TST5878) WRG-141-02-04 ASTM D 1970 2015a
WRG12001.2 FL298-R5 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
CREEK GCP Applied Technologies,Inc.
Self-Adhering Underlayments
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION AND APPLICATION
GRACE ICE& Grace Ice&Water Shield'is a high density cross laminated polyethylene surfaced self-
WATER SHIELD® adhered ASTM D 1970 underlayment for use on steep slope roofs.
GRACE ICE& Grace Ice&Water Shield'HT is a high density cross laminated polyethylene surfaced
WATER SHIELD®HT self-adhered ASTM D 1970 Type II underlayment for use on steep slope roofs
Deck Type: The roof deck shall be constructed of closely fitted
sheathing for new or existing construction.
Sheathing shall be installed in accordance with FBC
requirements. Roof decks shall have no more than
1/8"gap at abutting joints.
Attachment method: Underlayment shall be attached in accordance with
the FBC Table 1507.1.1 and manufacturer's
installation instructions
Allowable roof coverings: Mechanically attached roof systems as prescribed in
FBC Section 1507.1.1.
LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Roof slope limitations shall be in accordance with FBC requirements.
7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps
shall be staggered between courses in accordance with the manufacturer's application instructions.
8) The underlayment may be used as described in other current FBC product approval documents.
9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
10) The underlayment shall not be installed over existing roof coverings.
11) Underlayments may be exposed on the roof deck for a maximum duration of 30 days.
12) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
WRG12001.2 FI-298-R5 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
GpEEK GCP Applied Technologies,Inc.
[t Self-Adhering Underlayments
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code,6'"Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer.
,t%Ju1111►1,,I,' p
,,.`%% ,?:P�G EN.......
�'Fs�'•, 2010.02.2
• No 74021
2 11 .14.24
� � � d•p.areb saWa Pr,
�=
.13 STATE OF :•4/► -05'00'
Zachary R. Priest, P.E.
Florida Registration No.74021
Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
WRG12001.2 FI-298-R5 Page 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.