Loading...
HomeMy WebLinkAboutProduct Approval (4) f.14 SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us SCIS Site Map Links Search i bpr a f a '�;' Product Approval USER:Public User r ,sm Product Approval Menu>Product or Application Search>Application List>Application Detail>Application Checklist Form Title: Validation checklist for evaluation report from an architect or engineer Form#: 9N-3.011(3)(c) Administrative Validation 1. Verify the evaluator is a Florida Registered Architect or Florida Professional Engineer who has taken the core building code course. 2. Verify submission of the evaluator's certification of independence. G 3. If the evaluation is not performed by a third party independent of the manufacturer then verify validator's certificate of independence. W 4. Verify the evaluation report is for the products listed on the application as described on the application and that the products are within the scope of Rule 9B-72. [ 5. Verify that test reports demonstrating compliance were performed at a test lab accredited by an approved accreditation body for the test performed,and verify test lab location. Cj 6. Verify that the test reports or rational analysis are required by the Building Code as a component of a product approval for the product category and subcategory. 7. Verify that rational analysis demonstrating performance were executed utilizing current code requirements and was not used in lieu of a standardized test required by the Code or that rational analysis was not required. 8. Verify that all data,test reports and calculations,are substantiated on the report. EZ 9. Verify that the application has the Code sections and reference standards for which the evaluation demonstrates compliance. Wj 10. Verify the method of demonstrating compliance indicate any limitations on the use of the product,as intended. LZ 11. Verify the manufacturer installation Instructions are in accordance with the evaluation report,and attachments are provided. Q 12. Verify that a quality assurance program audited by a Florida Building Commission approved third party quality assurance agency is in place. To the best of my/our knowledge,this application is complete,the Items in the checklist above have been verified and reviewed,and the evaluation report submitted with this application indicates that the product,method,or system described in this application meets or exceeds the Florida Building Code requirements and reference standards listed in the application. Back Plext Contact Us::2601 Blair Stone Road.Tallahassee FI 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® E Credit Card Safe CREEK Certificate of Authorization No.29824 17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,6T"EDITION(2017) Manufacturer: GCP Applied Technologies, Inc. Issued February 22, 2018 62 Whittemore Avenue Cambridge, MA 02140 (617)876-1400 www.gcpat.com Manufacturing Plants: Bedford Park, IL Evanston, IL Mt. Pleasant,TN Drummondville,Quebec Quality Assurance: Benchmark Holdings, LLC(QUA9495) Ili SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year Intertek Testing Services NA(TST1585) 3173292COQ-0058 ASTM D 1970 2015a Intertek Testing Services NA(TST1585) 3150841 COQ-003A ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-017-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-018-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-050-02-02 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-141-02-03 ASTM D 1970 2015a PRI Construction Materials Technologies(TST5878) WRG-141-02-04 ASTM D 1970 2015a WRG12001.2 FL298-R5 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK GCP Applied Technologies,Inc. Self-Adhering Underlayments TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND APPLICATION GRACE ICE& Grace Ice&Water Shield'is a high density cross laminated polyethylene surfaced self- WATER SHIELD® adhered ASTM D 1970 underlayment for use on steep slope roofs. GRACE ICE& Grace Ice&Water Shield'HT is a high density cross laminated polyethylene surfaced WATER SHIELD®HT self-adhered ASTM D 1970 Type II underlayment for use on steep slope roofs Deck Type: The roof deck shall be constructed of closely fitted sheathing for new or existing construction. Sheathing shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Attachment method: Underlayment shall be attached in accordance with the FBC Table 1507.1.1 and manufacturer's installation instructions Allowable roof coverings: Mechanically attached roof systems as prescribed in FBC Section 1507.1.1. LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Roof slope limitations shall be in accordance with FBC requirements. 7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 8) The underlayment may be used as described in other current FBC product approval documents. 9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 10) The underlayment shall not be installed over existing roof coverings. 11) Underlayments may be exposed on the roof deck for a maximum duration of 30 days. 12) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. WRG12001.2 FI-298-R5 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. GpEEK GCP Applied Technologies,Inc. [t Self-Adhering Underlayments TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6'"Edition(2017)as evidenced in the referenced documents submitted by the named manufacturer. ,t%Ju1111►1,,I,' p ,,.`%% ,?:P�G EN....... �'Fs�'•, 2010.02.2 • No 74021 2 11 .14.24 � � � d•p.areb saWa Pr, �= .13 STATE OF :•4/► -05'00' Zachary R. Priest, P.E. Florida Registration No.74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT WRG12001.2 FI-298-R5 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. p