HomeMy WebLinkAboutSITE SPECIFIC BEACHDesign Information Risk Category 2 Windspeed 160 mph Exposure D Int. Press. Coef., GCp,(+/-) 0.18 a 6.SD feet Select the appropriate fastener size and spacing using the pre-engineered attachment schedule for the Florida Approved Product(s) or NOA used on this job. The contractor is responsible to ensure the use of the proper material, reinforcement, components, etc. to meet the indicated pressure per the product approval engineering document. The contractor is responsible to verify the component is in the appropriate zone using the "a" dimension shown above and diagrams shown below. The building pressures are calculated using the Allowable Stress Design. Contact Seaside Engineers immediately if the substrate at the attachment i .,t; s a ears to have deterioration ahn„rmauri— damage nr other conditions resulting in auestionable integrity. Component & Cladding Wind Loads Prepared for DVT Hurricane Shutters Inc Calculations by Seaside Engineers Project: Beach Residence Certificate of Authorization No. 32048 Location: 2478 Harbour Cove Drive 4265 60th Court Area Fort Pierce, FL 34949 Vero Beach, Florida 32967 Project ID: Zone or NOA Manufacturer Model Pressure (PSF) Pressure (PSF) (722)202-8008 info@seasideengineers.com Date: 5/28/2020 www.seasideengineers.com Design Information Risk Category 2 Windspeed 160 mph Exposure D Int. Press. Coef., GCp,(+/-) 0.18 a 6.SD feet Select the appropriate fastener size and spacing using the pre-engineered attachment schedule for the Florida Approved Product(s) or NOA used on this job. The contractor is responsible to ensure the use of the proper material, reinforcement, components, etc. to meet the indicated pressure per the product approval engineering document. The contractor is responsible to verify the component is in the appropriate zone using the "a" dimension shown above and diagrams shown below. The building pressures are calculated using the Allowable Stress Design. Contact Seaside Engineers immediately if the substrate at the attachment i .,t; s a ears to have deterioration ahn„rmauri— damage nr other conditions resulting in auestionable integrity. ROOF: WALL: I((tVD This item has been elec- tronically signed and •,••a••. K.",#,. ••.. ''.. sealed by Edward Rosh �`�: PE using a Digital Signa- Florida ture Printed oopies of document ' Product Q SQA OF •7�. ,.o r i'`1� .�( C R ��\�;` '. Area Approval # Building Design Product Design ID Opening Description (sgft) Zone or NOA Manufacturer Model Pressure (PSF) Pressure (PSF) 1 Shutter 39.9 5 FL12246.1 Expert Shutter Services Nautilus Rolling Shutter 40.4 -51.5 135.0 -135.0 2 Shutter 39.9 5 FL12246.1 Expert Shutter Services Nautilus Rolling Shutter 40.4 -51.5 135.0 -135.0 ROOF: WALL: I((tVD This item has been elec- tronically signed and •,••a••. K.",#,. ••.. ''.. sealed by Edward Rosh �`�: PE using a Digital Signa- No.72228 ture Printed oopies of document ' this are not considered signed and sealed and the signature Q SQA OF •7�. ,.o r i'`1� .�( C R ��\�;` '. must be verified on aryy E electronic copies. dW.r ,k le * No. 72228 • 2020.0 2-28 STATE OF ; 41i °:•665:2 3 1111,,��' Edward K R k P 0 04- May 28, 2020