Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
J Project Summary Job: - �wrightsoftEnt ie House ry By� QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34M Phone: 772-46SW99 Email: OUIOCC4LCS@AOLCOM For: STEVENSADDITION 2410 TAMARIND DRIVE, FT. PIERCE, FL 34949 Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Dagyrange Relative humidity M 50 % Moisture difference 61 gr1b Heating Summary Sensible Cooling Equipment Load Sizing Structure 3999 Btuh Structure 2503 Btuh Ducts 658 Btuh Ducts 809 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidbcation 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 4657 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 3146 Btuh Method Simpified Latent Cooling Equipment Load Sizing Construclion quality Average Fireplaces 0 Structure 477 Btuh Ducts 272 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) 749 Btuh Area(ftt) 228 228 Equipment latent load Volume (ff) 2143 2143 Archangges/hour 0.61 0.32 Equipment TotalLoad(Sen+Lat) 0.70 SHR 3895 0.4 Btuh ton Equiv.AVF(cfm) 22 11 Req. total capacity at Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MUZ-HM09NA"' Cond MUZ-HM09NA" AHRI ref 202680600 Cog MSZ-HM09NA" AHRI ref 202680600 Efficiency 10 HSPF Efficiency 12.0 EER,18 SEER Heating input Sensible cooling 6300 Btuh Heating output 10900 Btuh @ 47-F Latent cooling 2700 Btuh Temperature rise 33 OF Total cooling 9000 Btuh Actual air flow 300 cfm Actualatrflow 300 cfm AP flow factor 0.064 cfmBtuh Air flow factor 0.091 cfmBtuh Staticpressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Capacity balance point = 20 OF Backup: Input =2WV, Output = 6481 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed -Fk wr7ghtsaft- 2020-Jan-281423A9 A__r..A .-..., .- RightSuiR�UnW=1201919.0.07 RSU08101 Page 1 ..)Doalmen61Wn9htmRH\AOSTEVENSACDrrIOUmp Calc=tile Fmnt Duorface SW ° + wrightsoft° Right-JO Worksheet job: Entire House °ems QUICK CALCS, INC. 317 ST. LLICE LANE, FORT PIERCE, FL 34946fhone:772466-6799 Email: 0UKXGC LCS@A9L.ODM 1 Room name Entire House NEW BEDROOM 2 Exposed wall 43.0 0 43D it 3 Room height 9A 8 9A 8 heaYcool 4 Room dimensions 12.0 x 19D 8 5 Roomarea 228.0 IF 228.0 W Ty Construction U- alw Cr HTM Area (8°) Load Area (fF) Load number (BWIviP--°!) (BWh9Fj or perimeter (f) (BWh) or perimeter (tli (BWh) Heal Cool Gross WP)S Heat Cool Gross WPIS Heat Cool 6 W 13AAocs 0.143 se 4D0 2.19 113 113 452 247 113 113 452 247 V,V 13A4ocs 0.143 sw 4D0 2.19 113 101 404 ,221 113 101 404 221 t—G 4A5-2ob 0560 sw 15.68 2294 12 7 188 275 12 7 188 275 t5J �C 134-4acs 0.143 rw 4D0 2.19 179 154 655 358 179 _ 164 655 358 11 4A 22ob 0--w nw 15b6 33.75 15 0 235 506 15 0 235 505 C 16C30ml Onm - 090 128 228 228 204 292 228 228 204 292 F 22A-tpl 0989 - 27.69 0.00 228 43 1191 0 228 43 1191 0 61 c)AED excursion 1 4161 1 416 Envelops toss/gain 3329 2314 33291 Z314 12 e) Infilha6on 671 188 671 188 h Roomventilation 0 0 0 0 13 Irdemalgains: Occupants @ 230 0 0 0 0 Appliance.4olher 0 0 Subtotal (lines 6 to 13) 3999 2503 3999 2503 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3999 2503 3999 2503 15 Duct loads 16% 32% 658 809 658 809 Total room load 4657 3311 4G57 3311 Airrequlred(cfm) Sao 300 300 300 Cale latons approved byACCA to meet aV requirements of Manual J &h Ed. -F4'- wrl5-111- it- 202"n-281423.49 Rght-SuitcOUnwml2Ol9l9.D.O7RSLJOB101 page 1 _Z .amentsWthtsoftFfAC\STEVENSADIXIIONmp Calc=M18 Front Lborfaces SW