HomeMy WebLinkAbout3220LSG1 Tremco Drive. Terryville, CT 06786
phone: 860.582.0233 fax: 860.583.0949
signs@lauretano.com www.lauretano.com
Title
Sign TypePrintDate
Int. Note
City/State
Customer
SPES#Line
Location
Size
Description
of
AL
Parallel
Port St. Lucie, FL
Goodblend
ES-85592/06/20203402TM-2
1 3
2
60'-6"
7'- 8.8"
Building frontage: 467.8 sq ft
Wall sign
Reface Existing
4' 0" x 7' 6" (30 sq ft)
Reface existing: Cut-thru backed-up
illuminated wall sign.
This item was reviewed by John J. Orlando PE.
This item has been electronically signed and sealed by
John J. Orlando, PE on using a digital signature.
Printed copies of this document are not considered signed
and sealed and the must be veried on any electronic copies.
Conforms to the requirements of the 6th Edition (2017)
of the Florida Building Code sections 1604, 1609 & app. H
V(ult) = 160 mph
Exposure category = C
Risk category = II
John J. Orlando PE LLC
165 Old Ridge Road
Macon, GA 31211 478 731 5394
jjorlando@cox.net
Florida registration # 0044089
job 3220LSG
sheet 1 of 3
1 Tremco Drive., Terryville, CT 06786 • Phone: 860.582.0233
signs@lauretano.com www.lauretano.com
Installation Method
of
ES#Line
Print Date
= Critical Dimension for
Internal Quality Control UL FILE NO. E70436 Amps Volts
ES-8559
2/06/20203402TM-2
2
2 3
92.8"
Fascia height
7'-8 3/4"
Scale: 1/4"=1'
6 "
4'-0"
7'-6"
MATERIALS / COLORS
1/8" Aluminum Face, painted black
1/8" White acrylic
Reface Existing Wall Sign
Countersunk screws through face,
painted black to match face.
Existing Condition
1' 4.65"
6' 0.85"
CUT-THRU BACKED-UP
W/ .125" WHITE ACRYLIC
1/8" ALUMINUM FACE
NOTES
Paint all sides of existing
cabinet black to match face.
2' 9.0"
1/4" SELF TAPPING SHEET METAL SCREWS
6 EVENLY SPACED PLACES
This item was reviewed by John J. Orlando PE.
This item has been electronically signed and sealed by
John J. Orlando, PE on using a digital signature.
Printed copies of this document are not considered signed
and sealed and the must be veried on any electronic copies.
Conforms to the requirements of the 6th Edition (2017)
of the Florida Building Code sections 1604, 1609 & app. H
V(ult) = 160 mph
Exposure category = C
Risk category = II
John J. Orlando PE LLC
165 Old Ridge Road
Macon, GA 31211 478 731 5394
jjorlando@cox.net
Florida registration # 0044089
job 3220LSG
sheet 2 of 3
Job name Goodblend 5336 Port St. Lucie
Job#3220LSG
Sign company:Lauretano Sign Group
Installation location:7061 US-1, Port St. Lucie, FL 34952
Section 1609.6.4 of Florida Building Code 2017 applies.
Application of wind pressures using the alternative all heights method for components and cladding
Type of structure:1/8" aluminum panel (sign face change)
Occupancy Category:II
Ultimate design wind speed, figure C, FBC 2017, section 1609:160 mph
W ind stagnation pressure (qz) per 1609.6.3 FBC 2017 65.5 psf
Net Pressure Coeficient (Cnet) from Table 1609.6.2 (1)
Components and cladding not in areas of discontinuity - walls and parapets -1.09
Wind Pressure -71.4 psf
Wind load applied between wall and structure, pulling structure away from wall
Load carried by tension in fasteners connecting structure to wall
- maximum height of structure to be attached 4.00 ft
- maximum width of structure to be attached 6.07 ft
- fill factor 1.00
- projected area of each component to be attached 24.3 ft^2
- wind load -1734 lbs
- design limit tension load per fastener to 400 lbs
- even number of fasteners minimum of 2 =-6
- number of fasteners practically required due to structure shape 6
- weight of structure is approximately 121 lbs
- design limit shear load per fastener to 125 lbs
- average shear load per fastener =20.2 lbs
Mounting surface construction is:existing aluminum sign cabinet extrusion
Use methods:#10 self tapping sheet metal screws
Method - #10 self tapping sheet metal screws (ITW Teks Select 10-16 x 3/4" part no. 1076000).
http://www.itwbuildex.com/pdf/teks_select_datasheet.pdf
- design tension (pull out) load = 400 pounds
References:
ASCE 7-10
The 6th Edition (2017) of the Florida Building Code
sheet:3 of 3
John J. Orlando PE LLC 0044089
165 Old Ridge Road
Macon, GA 31211
(478) 731-5394
jjorlando@cox.net
This item was reviewed by John J. Orlando PE.
This item has been electronically signed and sealed by
John J. Orlando, PE on using a digital signature.
Printed copies of this document are not considered signed
and sealed and the must be veried on any electronic copies.