Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProject InformationRECENED
Load Short Form
'�-
Jab:
7902 James Road
wrighisoft'
DEC 21 2019
Data:
November3, 2019
Entire House
By.,
Josh Putman
WebReps LLC.
Permitting Department
Plan
79D2 James Road
•
St. Lucie County
1892 Con re ue A•nue, %tro Beads, R. 32960 Phone: 800-8103280 Emei: manua1j@mbrepshwcmm
For. Joseph W. Gianna, St Lucie Habitat for Humanity, Inc
702 South 6th Street, Fort Pierce, FL 34950
Phone:772-464-1117
Web: www.stiuciehabitatorg Ernskjoseph@stluciehabitatorg
Htg
Clg Infiltration
Outside db(°F)
41
90 Method Simplified
Inside db (eF)
70
75 Construction quality Semi -tight
Design TD CF)
29
15 Fireplaces
Dailyrange
-
L
Inside humidity ffi)
30
50
Moisture difference (grAb)
.2
57
HEATING EQUIPMENT
Make Goodman
Trade Heat Strip
Model
AHRI ref
Efficiency
Heatinginput
Heating output
Temperature rise
Actual airflow
Airflowfactor
Static pressure
Space thermostat
100 EFF
8.0
kW
27297
Btuh
27
°F
920
cirri
0.052
dm/Btuh
0.60
in H2O
COOLING EQUIPMENT
Make Goodman Mfg.
Trade GOODMAN
Cond GSX160301F
Coil ASPT30C14A
AHRI ref 200825240
Efficiency 13.0 EER,
Sensible cooling'
Latent000ling
Total cooling
Actual airflow
Airflowfalaor
Static pressure
Load sensible heat ratio
16 SEER
20424
Btuh
7176
Btuh
27600
Btuh
920
rim
0.049
dim/Btuh
0.60
in H2O
0.76
ROOM NAME
Area
(ffT)
Htg load
(Btuh)
Clg load
(Btuh)
H(gAVF
(rim)
CIgAVF
(rim)
Bed
191
R aE
FC3P" 2798
1922
1388
Bath 2
117
m
�.IP" ' 1650
69
81
Bed 3
129¢ 9.
�C. a 24588
164
1211
�. ��o
Living Rm
245
C 4069
150
201
Kitchen
252
3970
113
196
Bed
174
2274
2418
119
119
pnty
21
0
0
0
0
cist 1
18
0
0
0
0
dC
'149A
IaaA
III
CA
odul I
®�Calculations approved YA to mall 1in ments ofManual J 8th Ed..
-*- elvrightsoft 2019-Nov-0616AIAB
CC$ Ri9hiSuI�QDUnP.era1201919.0.09 RSU76998 Pagel
/YL.t.A.-ACWabifatfor Hu nhyPSLV902Ja sRoadnlp Catc-MI6 FrontD=fam%S
Entire House
1335
17533
18658
920
920
Other equip loads
46
1707
Equip. @ 1.00 RSM
20364
Latent000ling
6487
1335
17579
26851
1 920
920
OTALS
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-F#F wrightsofY zola�w rws tsnt:te
RghMftvDWiuetsal 201919.0.09 RSU16998 Paget
/tCC.i1..AcilabitalforHmianityPSLV902Jam Roadmp CaIc=MD! FronlDoorfaces: S
- Pro ect
1 Summa ry
Job:
7902 James Road
wrightsofC
Entire House
Data:
By:
November 3, 2019
Josh Pubnan
WebReps LLC.
Plan:
7902 James Road
1892 CormreroeAenue,Wro Beach, FL 32960 Phone: 80O-8103280 Eme9:manua11@xebrepshvaccnm
Project• •
For: Joseph W. Gianna, St Lucie Habitat for Humanity, Inc'
702 South 6th Street, Fort Pierce, FL 34950
Phone:772-464-1117
Web: wwwstiuciehabitatorg Email:joseph@stiuciehabitatorg
Notes: 7902 James Road Ft Pierce FL
Desi n Information
Weather.
Winter Design Conditions
Outside db 41 OF
Inside db 70 OF
Design TD 29 OF
Heating Summary
St Lucie Co Inti, FL, US
Structure
14628 Btuh
2900
Central vent (0 cfm)
Btuh
(none)
Humidification
46 Btuh
Equpmentload
Bhtrh
17579
Infiltration
Method
Simplified
Construction quality
Semi -tight
Fireplaces
0
Heating Coolinr�q
1335
Area (n
1335
Volume (fly
10684. 10684
Airchangesmour
0.16 0.08
Equiv AVF (dim)
28 14
Heating Equipment Summary
Make Goodman
Trade HeatSbip
Model
AHRI ref
Efficiency
Heatinglnput
Heating output
Temperature rise
Actual airflow
Airflowfactor
Static pressure
Space thermostat
100 EFF
8.0 kW
27297 Btuh
27 OF
920 cfrn
0.052 cfm/Btuh
0.60 in H2O
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
DesignTD
15
OF
Daily range
L
Relativehumidity
50
%
Moisture difference
57
grub
Sensible Cooling Equipment Load
Sizing
Structure
14022
Btuh
4630
tu
Btuh
Central vent (0 cfm)
on
Slower
1707
Btuh
Use manufacturers data
Rate/swingg mulfiplier 1.00
Equipmentsensible load 20364 Btuh
Latent Cooling Equipment Load Sizing
Structure
5550
Btuh
Ducts
936
Btuh
Central vent (0 cfin)
0
Btuh
(none)
Equipment latent load
6487
Btuh
Equipment Total Load (Sen+Lat) 26851 Btuh
Req. total capacity at 0.7,4 SHR 2.3 ton
Cooling Equipment Summary
Make Goodman Mfg.
Trade GOODMAN
Cond GSX160301F
Coil ASPT30C14A
AHRI ref 200825240
Efficiency 13,0 EER,16 SEER
Sensiblecooling
20424
Btuh
Latent000ling
7176
Btuh
Total cooling
27600
Btuh
Aclualairflow
920
cfrn
Airflowfactor
0.049
cfmBtuh
Static pressure
0.60
in H2O
Load sensible heat ratio
0.76
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
Vffwf•t ow vere2019.*"616:41:18
Wgh4Sulte®lhie1201B 1BAA8 RSU18B98 -
AM..ACViabltaUor HumanityPSL17902Jemes Roed.rop Celc-MIB FrontDoorlew&,S pe9e1
N
Main Floor
Bed 3
12 x 8 j c2
Bath 2
c3 ,
194cfm
7"
10x6
165 ctn
Bed 2 i.. -.
7"
8x4
5„
81 cfrn
12 x 12
12 x 12
194 ctn
165 cfm
-
8 811
Living Rm 12"
8x8 � 8x8
100 cfm 8 x 8 196 ctn Kitchen
100 cfm 6..
7"
6"
AA
6"
14"
12" 20x2O 12x12
478 cfm 232 cfm
9
1411
PntY
9„
u
8"
1OX6
18 x 18
114 cfm
6„
Garage 18x12
6"
Bath 1
10x6
119 cfm
dst 1
Bed 1
Job M 7902 James Road
WebReps LLC.
Scale'. 1: 70
Pertommd by Josh Putman for.
Pg1
Joseph W.Genna
1892 Commerce Plenue
ROtSAOUdmWD19
702 South 6th Street
Fort Pierce, FL 34950
Vero Beach, FL32960
Phone: 8003103280
194mRSWOM
2D19t4oH3164201
Phone:772-464-1117
manuanviebrepshvacwm
-H=*PSLV9MJaneSRO3in.V
w.wvstiucehabdatorg joseph@stYldehabdatorg
4�
- - wilightsoft- Duct System Summary
Entire House
WebReps LLQ
Job:
7902 James Road
Date:
November 3, 2019 -
By.
Josh Pubnan
Plan:
7902 James Road
1692 Conrrerce,Aenue,Varo Beach, FL 32960 Phone: 800-8103260 Email: manualjawsbrepsNaccom
For. Joseph W. Gianna, St Lucie Habitat for Humanity, Inc
702 South 6th Street, Fort Pierce, FL 34950
Phone:772464-1117 -
Web:www.stluciehabitatorg Email:joseph@stludehabitatorg
Extemal static pressure
Pressure losses
Available static pressure
Supply/return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.60
in H2O
024
in H2O
0.36
in H2O
0.200/0.160
in H2O
0.072
in/100ft
920
d m
500 ft
Supply Branch Detail Table
Cooling
0.60'
in H2O
0.24
in H2O
0.36
in H2O'
0,200 / 0.160
in H2O
0.072
in/100ft
920
dm
Name
Design
(13tuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Dud
Mal
Actual
Ln (ft) .
Ftg.Egv
Ln (ft)
Trunk
Bad
h 3652
192
138
0.073
7.0
Ox0
VIFx
29.6
245.0
st4
Bath2
c 1650.
69.
81
0.078,
4.0
Ox0
VIFx
22.2
235.0
st4
Bed
h 3121
164
121
0.072
7.0
Ox0
VIFx
32A
245.0
W
LMng fbnA
c 2035
75
100
,0.086
5.0
OXO
VIFx
11.9 .
220.0
st3
Wing Pon
c 2035
75
100
0.083
'5.0
OXO
VIFx
20.0
220.0
st3
rJtdfen
c 3970
113
196
0.075
7.0
OXII
VIR
21.1
245.0
st5
Bed
c 2274
119
119
0.081
6.0
OxO
VIFx
17.2
230.0
st2
Bath 1
h 2154
113
64
0.079
1 5.0
Ox O
VIFx
21.3
1 230.0
s@
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diann
H x W
Dud
Name
Type
(cfm)
(dm)
FIR
(fpm)
(in)
(in)
Material
Trunk
s14
PeakAVF
424
341
0.072
540
12.0
0 x 0
VinIFIX
st3
st5
PeakAVF
113
196
0.075
732
7.0
0 x 0
VinIFIX
st3
st1
PeakAVF
920
920
0.072
613
16.2
12 x 18
RedFbg
st3
PeakAVF
688
737
0.072
689
14.0
0 x 0
VinIFIX
st1
st2
PeakAVF
232
183
0.079
666
8.0
0 x 0
VinIFIX
st1
�'i/.�.� -rk Wrightsofe NghFSuile®UniwrsW201919.0.09RSU16998
//Vi/1 -AG4 abllatfar HumanityPSLV902 James Roaduup Caic=MJa FmnlCoorfams: S
2019.Nov061841:19
Page 1
Return Branch Detail Table
Grille
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (n)
(cfm)
(cfm)
(ft)
FIR
(fpm)
(in)
(n)
Opening (in)
Mad
Trunk
rb4
Ox0
232
183
121.9
0.132
526
9.0
Ox 0
VIFx
rt1
rb3
Ox0
192
138
217.1
0.074
549
8.0
Ox 0
VIFx
rt2
rb2
Ox0
164
121
222.8
0.072
469
'8.0
Ox 0
VIFx
rt2
rb1
Ox0
332
478
97.3
0.165
447
14.0
Ox 0
VIFx
rt1
Return Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Dud
Name
Type
(cfm)
(dim)
FIR
(fpm)
(in)
(n)
Material
Trunk
rt1
PeakAVF
920
920
0.072
409
16.2
18 x 18
RectFbg
rt2
PeakAVF
355
259
0.072
452
12.0
0 x 0
VInIFIX
rt1
9
* wrightsoft^ 2019.No*0618AI:f9
AMAw ,,,,.., _.r,,.,Ri9hlSuite®LNherse1207919AA9 RSU18998 Pe9e2
.-ACftbitatforHumanily Y. PSLVMI 902JamesRoadmp Calc=S FmntDoorfame S
s