Certification for Design Load Compliance
Project Name: McDonald's NSN-22447 Menu Boards Replacement
Project Address: 7626 S US Highway 1 Port St.Lucie FL 34983
Permit#:- Occupancy Type: Construction Type:Menu Board Signs
INSTRUCTIONS FOR USE:
• This certification must be completed,signed,and sealed by the design professional of record.
• Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Sixth Edition with 20 17 Supplements using ASCE 7-10
I
2. Structure Designed as(check one): Enclosed Partially Enclosed x Open 1
3. Risk Category: I x II III IV Exposure Category:—B x C D
4. Design Wind Velocity 160 mph x ASD LRFD End Zone Width: na ft
5. Mean Roof Height na ft Roof Pitch: na :12 Parapet: na ft
6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):nal
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor: 0 PSF Roof/Dead: 0 PSF Roof/Live: 0 Balcony: 0 PSFi
Dock: 0 PSF Deck: 0 PSF Stairs: 0 PSF Fence: 0 PSF Railings: 0 PSF
8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not:
its a menu board
9. Is A Continuous Load Path Provided? x Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? no Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans &specifications have been designed to,
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also,cer i 'that structural elements depicted on these plans provide adequate resistance to the design
forc s Qci d:, 1
. .• Anthony Scenna 77994 33159
_ Print Name Cert#&Co.Cert Auth.
The Kachele Group
1000 Whitehorse Rd.,Suite 406,Voorhees,NJ
i
Signature;Date;,and.Seal-
Company Name&Address