Loading...
HomeMy WebLinkAboutCertification for Design load Compliance Planning&Development Services Department • Building&Code Regulations Division I - --— - 2300 Virginia Avenue, Fort Pierce, FL 34982-(772)462-1553 Certification for Design Load Compliance Project Name: McDonald's NSN-22447 Menu Boards Replacement Project Address: 7626 S.US Highway 1,Port St.Lucie,FL 34983 i Permit#: 2 00 (p- n aOC� Occupancy Type: Construction Type:Menu Board Signs a INSTRUCTIONS FOR USE: • This certification must be completed,signed,and sealed by the design professional of record. • Submit(2)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Sixth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as(check one): Enclosed Partially Enclosed x Open 3. Risk Category:_l x II III IV Exposure Category:—B x C D I 4. Design Wind Velocity 160 mph x ASD LRFD End Zone Width: na ft 5. Mean Roof Height na ft Roof Pitch: na :12 Parapet: na ft 6. Components&Cladding Design Pressures Used:(PSF,based on 10sgft @ 15'MRH,clearly label on all plan openings):na Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: 0 PSF Roof/Dead: 0 PSF Roof/Live: 0 Balcony: 0 PSF Dock: 0 PSF Deck: 0 PSF Stairs: 0 PSF Fence: 0 PSF Railings: 0 PSF 8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not: its a menu board 9. Is A Continuous Load Path Provided?_ Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? no Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also, e,r ifij)th'at-structural elements depicted on these plans provide adequate resistance to the design for sp `fi,d: - !� \ Anthony Scenna 77994 33159 - Print Name Cert#&Co.Cert Auth. The Kachele Group 1000 Whitehorse Rd.,Suite 406,Voorhees,NJ SYg netur6, Date,-and Seal Company Name&Address Revised 12/07/2018 I I I