Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
Load Short Form Entire House MECHANICALA/C 1V3KKILLIANDP-LAKEPAPtSFL3UO3 E=3:lhwrMECRANCALACCOMNEb:Ur-CAC1E16081 iLroject intormation For. SUNSET KEY CUSTOM _PEPrrONE, PORT ST LUCIE PROPERTIES 6004 HICKORY DR, FORT PIERCE, FL 34982 Job: Date: 1012512019 By: Plane SUNSET FCEY_CUSTOM Design Information Htg Clg Infiltration Outside db (°F) 41 91 Method Simplified Inside db (°F) 68 75 Construction quality Semi -loose Design TO (°F) 27 16 Fireplaces 0 Daily range - L Inside humidity (0/6) 50 50 Moisture difference (grAb) 21 54 HEATING EQUIPMENT Make Goodman Mfg. Trade FRANKUN Model HKSC08XC AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfactor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 32 OF 787 dm 0.041 cfmBWh 0.50 in H2O COOLING EQUIPMENT Make Franklin Trade FRANIO_IN Cond GSX160241F` Coil ASPT33C14A' AHRI ref 201498266 Efficiency 13.0 EER, Sensible 000ling Latent cooling Total cooling Actual airflow Airfawfactor Static pressure Load sensible heat ratio 16 SEER 18880 Btuh 4720 Btuh 23600 Btuh 787 cfm 0.044 chnBtuh 0.50 in H2O 0.80 ROOM NAME Area (fl2) Htg load (Btuh) Cig load (BWh) HtgAVF (ern) CIgAVF (fin) MB 96 1568 853 64 38 MC 65 1200 616 49 27 MBR 250 1925 2073 79 92 WCHEN 150 1358 2486 56 110 LIVING 375 3663 4101 150 1 181 BDRM 3 177 2396 1982 98 88 BTH2 56 643 405 26 18 DINING 106 1427 1771 58 78 LAUN 62 479 882 20 39 GARAGE 428 0 0 0 0 bdnn 2 194 4539 2616 186 116 H 24 0 0 0 0 H2 31 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J81h Ed. .� -I+F-wrightsoft' yplgOe2508MV + ..,,.., ,,.^�, (aghlSuite®Utiyersa1201919A.12 RS1A8764 I'mpelf :s USTOMMO�1SlSLMETKEY-PEPPnONE=p Calc=Ml9 FmnlDwf@ es N Pagel Entire House 2027 19222 17807 787 787 Other equip loads 0 0 Equip. @ 1.00 RSM 17807 Latent cooling 4333 Tn1 Al C nnn7 4nnnn nn4 nA O01 909 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Wrightsoft- 2019-0d4508M25 Rgh4Suite®UnM1e181201919.0.12 RSLI08764 Pa9e2 apeAeSLUSTOMMODELS%SONSETKEKPEPPfrONFi p Cdc=MJ8 FtwlM=fas N Project Summary Entire House MECHANICAL A/C 1373 N. KILLIAN DR, LAI9=PARK, FL 33483 Emal-wWNMECWMCALAGCOMNCb:UC.CAC1816M Job: Data: 10/2612019 By: Plan: SUNSET KEY CUSTOM For. SUNSET KEY CUSTOM PEPITONE, PORT ST LUCIE PROPERTIES 6004 HICKORY DR, FORT PIERCE, FL 34982 Notes: Weather. St Lude Co Intl, FL, US Winter Design Conditions Outside db Inside db Design TD Heating Summary Summer Design Conditions 41 OF Outside db 68 OF Inside db 27 OF Design TD Daily range Relative humidity Moisture difference Structure 16610 Btuh 2610 Central vent (0 c1m) BBtuh (none) Humidification 0 Btuh Piping 0 Btiuh Equipment load 19222 Btuh Infiltration Method Simplified Construction quality Semi -loose Fireplaces 0 Heatin Cool Area 1599 99 5 Molume (M 14061 14061 Airdlangeslhour 0.59 0.31 Equiv AUF (clm) 138 73 Heating Equipment Summary Make Goodman Mfg. Trade FRANKLIN Model HKSC08XC AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfador Static pressure Space thermostat 100 EFF 8.0 kW 27297 Bfuh 787 actin 0.041 dmA3tuh 0.50 in H2O 91 OF 75 OF 16 OF L 50 % 54 grAb Sensible Cooling Equipment Load Sizing Structure 16098 Btuh 8 1700 Btu Central vent (0 chm) BBluh (none) Blower 0 Btuh Use manufacturers data Ratetswingg multipplier 1.00 Btuh Equipmentsensibleload 17807 Latent Cooling Equipment Load Sizing Structure 3445 Btuh Duds 887 Btuh Central vent (0 c1m) 0 Btuh (none) Equipment latent load 4333 Btuh Equipment Total Load (Sen+ at) 22139 Btuh Req. total capacity at 0.80 SHR 1.9 ton Cooling Equipment Summary Make Franldin Trade FRANKLIN Cond GSX160241F` Coil ASPT33C14A' AHRI ref 201498266 Efficiency 13.0 EER,16 SEER Sensible cooling 18880 Btuh Latentcooling 4720 Btuh Total pooling 23600 Btuh Actual airflow 787 cfm Airflowfador 0.044 dmBbuh Static pressure 0.50 in H2O Load sensible heat ratio 0.80 Calculations approved byACCAto meetall requirements of Manual J 8th Ed. _ 85025 � wrigh�ts_o`1Ft RghkSuit.VUA erd201919D.12RS1198764 2019�a-250PageI /1CC{1 �pedesVZSTOM MODELWUNSETKEY-PEPPROWE p Cale=M18 FtontDoorta= N Manual S Compliance Report Date: 10/25/2019 Entire House By. ,n MECHANICALA/C P1are suruErl¢v_cusroM 1373 N. KILLIAN DR, LAKE PARK, FL 33403 Emm1:WMVMECHA"CALAC.COMNPb:UCCAC1816081 Project• • For. SUNSET KEY CUSTOM PEPTfONE, PORT ST LUCIE PROPERTIES 6004 HICKORY DR, FORT PIERCE, FL 34982 Cooling Equipment Design Conditions I Outdoor design DB: 912OF Sensible gain: 17807 Btuh Entering coil DB: 75.1°F Outdoor design VVB: 77.1 OF Latent gain: 4333 Btuh Entering coil VVB: 62.8°F Indoor design DB: 75.0°F Total gain: 22139 Btuh IndoorRH: 50% Estimated airflovr 787 dm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer. Franldin Actual airflow: 787 cfin Sensible capacity. 18880 Btuh Latent capacity., 4720 Btuh Total capacity. 23600 Btuh Model: GSX160241F'+ASPT33C14A• 106% of load 109% of load 107%of load SHR: 80% Heating Equipment Design Outdoor design08: 41.0°F Heat loss: 19222 Btuh Indoor design DB: 68.0'F Manufacturer's Perfor nance Data at Actual Design Conditions Equipmenttype: Elecstrip Manufacturer. Goodman Mfg. Actual airflow. 787 dm Output capacity. 8.0 WV Meets all requirements ofACCA Manual S. Model: HKSC08XC 142%of load Entering coil DB: 67.9°F Temp. rise: 32 OF * Wrightsof - 2019-0a25083025 C lSphFSuite&lkdwrsW201919A.12RSU08764 Pagel ._oPertwTAISTOMMODELS-SIBSETKEY-PEPPROWE p Cale -KW FontD=1aoe& N