s%i onal CERTIFIED' www.ahritl irectory.org AHRI Certified Reference Number: 201498266 Date: 01-02-2019 Model Status: Production Stopped Old AHRI Reference Number: 10206644 AHRI Type: RCU-A-CB Series: GSX16 Outdoor Unit Brand Name: FRANKLIN Outdoor Unit Model Number (Condenser or Single Package) : GSX160241 F' Indoor Unit Model Number (Evaporator andfor Air Handler) : ASPT33C14A• Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions _ until June 3Q 2016. Beginning July 1, 2016 _central a'a conditioners can only be installed in regien(s) rating, of this system combination. ❑r Cooling1 Capacity (A2) - Single or High Stage (95F); btuh : 23600 SEER,: 6;00 w8woftIM91TOdWwowo EER (A2)\`-,rSingle or High Stage (95F) :13.00 rAritve' Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced'Production Stopped' Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is soli selling or offering for sale. Retinas that are acmmoanied by WAS indicate an inveluntary re -rate. The new published rating is shown _alonq_withthe revious r.e WASLrrdi g DISCLAIMER AHRI does not endorse the pmduct(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data fisted on this Certificate. Certified ratings are valid only for models and configurations listed In the . directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes The contents of this Certificate may not, In whole or In part, be reproduced; cepled; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual, personal and confidential reference. „ AIR-CONDITIONING. HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information forthe model cited on this certificate can be verified at www.ahrldireetory.org• click an"Verify Certificate' link we make lire bcuer` and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed at bottom right - - - ©2019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 131909355657274230 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SUNSET KEY MODEL PEPITONE_2019 Builder Name: PORT ST LUCIE PROPERTIES Street: 6004 HICKORY DR Permit Office: City, State, Zip: FT PIERCE, FL, 34982 Permit Number: Owner. Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL County: SL Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1530.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1364.20 ft' b. Frame - Wood, Adjacent R=11.0 176.00 112 3. Number of units, if multiple family 1 c. NIA R= 112 4. Number of Bedrooms 3 d. N/A R= f' 10. Ceiling Types (1602.0 sqft.) Insulation Area S. Is this a worst case? Yes a. Roof Deck (Unvented) R=20.0 1602.00 112 6. Conditioned floor area above grade (ft2) 1602 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 11. Ducts R ft2 7. Windows(125.7 sqft.) Description Area a. Sup: Attic,;Ret: Main, AH: Main 6 275.2 a. U-Factor. Dbl, U=0.58 40.11 ft2 SHGC: SHGC=0.24 b. U-Factor. Dbl, U=0.29 40.00 ft' 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.29 a. Central Unit 23.6 SEER:16.00 c. U-Factor. Dbl, U=0.62 39.01 ft' SHGC: SHGC=0.22 13. Heating systems kBtuthr Efficiency d. U-Factor. other (see details) 6.60 112 a. Electric Strip Heat 28.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.754 ft. Area Weighted Average SHGC: 0.250 14, Hot water systems a. Electric Cap: 40 gallons 8. FloorT yp es (1602.0 sgft.) Insulation Area EF: 0.930 a. Slab -On -Grade Edge Insulation R=0.0 1602.00 112 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.078 Total Proposed Modified Loads: 54.85 PASS Total Baseline Loads: 55.50 I hereby certify that the plans and specifications covered by Review of the plans and OF'CKE STq�� this calculation are in compliance with the Florida Ener y Code. specifications covered by this li di i calculation indicates compliance y , _ z O� MECHANICAL Florida Energy Code. F mn4•+, "+ rd„ O PREPARED BY: Air conditioning Corp. with the Before construction is completed r DATE: 2 9 this building will be inspected for compliance with Section 553.908 O y hereby certify thatLthisuilding de ' ed, is i mpliance Florida Statutes.with the Florida Enead COD WB'� OWNER/AGE . BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). F11-E copy 10125/2019 9:22 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Bdsting: Comment: SUNSET KEY MODEL_PEPI User 1 PORT ST LUCIE PROPERTI Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 1602 Total Stories: 1 Worst Case: Yes Rotate Angle: 180 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook Street: 6004 HICKORY OR County. St. Lucie City, State, Zip: FT PIERCE, FL, 34982 CLIMATE Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blackl 1602 14418 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1602 14418 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 167 ft 0 1602 ft' — 0.5 0 0.5 ROOF V # Type Materials Roof Gable Roof Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1792 ft' 0 ft' Unfinishe N 0.96 No 0.4 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Unvented 0 '1602 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 0 Blown. 1602 ft' 0 Wood 10125/2019 9:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 W=>E Exterior Concrete Block- Int Insul Main 4.0999 20 3 8 162.0 ft' 0 0.5 0 -2 W=>E Exterior Concrete Block- Int Insul Main 4.0999 16 9 4 149.3 ft' 0 0.5 0 _ 3 W=>E Exterior Concrete Block - Int Insul Main 4.0999 21 9 8 174.0 ft' 0 0.5 0 -4 N=>S Exterior Concrete Block - Int Insul Main 4.0999 34 8 272.0 ft' 0 0.5 0 -5 E=>W Exterior Concrete Block- Int Insul Main 4.1 13 2 8 105.3 ft' 0 0.5 0 -6 S=>N Exterior Concrete Block- Int Insul Main 4.0999 7 5 8 59.3 ft' 0 0.5 0 -7 E=>W Exterior Concrete Block- Int Insul Main 4.0999 24 2 9 4 225.6 ft' 0 0.5 0 -8 N=>S Garage Frame - Woad Main 11 22 8 176.0 ft' 0.2 0.5 0 9 S=>N Exterior Concrete Block- Int Insul Main 4.0999 25 10 8 206.7 ft' 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In _ 1 E=>W Insulated Main None .46 6 8 48 ft' 2 N=>S Insulated Main None .46 2 6 8 20 ft' WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W=>E 1 Metal Double (Tinted) Yes 0.58 0.24 N 16.6 ft' 1 ft 0 in 1 ft 0 in None Exterior 5 2 W=>E 2 Metal Double (Tinted) Yes 0.29 0.29 N 40.0 ft' 10 ft 0 in 1 ft 0 in None Exterior 5 3 W=>E 3 Metal Dxiuble (Tinted) Yes 0.58 0.24 N 16.6 ft' 1 ft 0 in 1 ft 0 in None Exterior 5 4 N=>S 4 Metal Double (tinted) Yes 0.58 0.24 N 6.9 ft' 1 ft 0 in 1 ft 0 in None Exterior 5 5 E=>W 5 Metal Double (Tinted) Yes 0.62 0.22 N 16.6 ft' 1 ft 0 in 1 It 0 in None Exterior 5 _ 6 E=>W 7 Metal Double (-Iinted) Yes 0.62 0.22 N 22A ft' 6 ft 0 in 1 110 in None Exterior 5 7 S=>N 9 Metal Double (Clear) Yes 0.58 0.24 N 6.6 ft' 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 400 ft' 400 ft' 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 EIA EgLA ACH ACH 50 1 Wholehcuse Proposed ACH(50) .000343 1441.8 79.15. 148.86 .1246 6 10125/2019 9:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 28 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Black Ducts 1 Central Unit/ None SEER: 16 23.6 kBtuRrr 708 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS —Supply— # Location R Value Area —Return Air Location Area Leakage Type Handler CFM 25 TOT CFM25 OUT ON RLF HVAC# Heat Cool 1 Attic 6 275.2 ft Main 68.8 W Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablee('IThermostat: Y IrX'I Mar Cooling Jan Feb Venting [ ] Jan H Feb [X] Mar r Ceiling Fans: IrX (rX IIX may Apr € i May [ Jun [ Jul [ AAAug u Sep p r Oct rIX Nov Nov [X� Nov Dec IrX [ Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Healing(WD) AM 66 PM 68 Heating(WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs1s .fL 0 ft' 0 ft 0.3 Main 10125/2019 9:2.2 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 23.6 a) Split system SEER 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. fQ 6. 1602 d) Room unit/PTAC JEER e) Other 16.0 7. Windows, type and area a) U-fadar.(weighted average) 7a. 0.500 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 28.0 c) Area 7c. 125.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.93 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit Heati B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed base stalled a compliant features. A Builder Signature: Date: Address of New Home: 6004 HICKORY DR City/FL Zip: FT PIERCE FL 34982 10/25/2019 9:22:58 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 6004 HICKORY DR Permit Number: FT PIERCE, FL, 34982 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory).The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. ❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402A.1 through R402A.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveldpe building thermal envelope shall comply with Sections R402.4.1.1 and R402A.12. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. Ei R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402A.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402A.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(% (g) or () or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be dosed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers Including exhaust, intake, makeup air, backdraft and flue dampers shall be Gosed, but not sealed beyond Intended infiltration control measures. 3. Interior doors, if Installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402A.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402A.3 Fenestration air leakagdMindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 L/slm2), and swinging doors no more than 0.5 drn per square foot (2.6 L/slm2), when tested according to NFRC 400 or AAMAI WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 10/25/2019 9:23 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R402.4.4 Rooms containing fuel-buming appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both Intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402A.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfrm (0.944 Lls) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSVRESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (J), Florida Statutes, to be "substantially leak free' in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturers designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturers air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test 2. Postoonstmction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturers air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: I. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of earying fluids above 105°F (41`C) or below 557 (1 WC) shall be insulated to a minimum of R-3. El caused Protection of piping Insulation. Piping insulation exposbd to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times When heated water is used in the occupancy. 10/2512019 9:23 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the Inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 h inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). Fi R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -heating systems to be turned off. ❑ R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropdate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system Is not operating. ❑ R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and rested HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the wails of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the calling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and Indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is Installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFMIWATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfmtwatt Any Bathroom, utility room 10 1.4 cfmhvatt <90 Bathroom, utility room 90 2.8 cfmlwatt Any For SI: 1 cfrn = 28.3 L1min. a. When tested In accordance with HVI Standard 916 10125/2019 9:23 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R403.7.1.1 Cooling equipment rapacity. Cooling only equipment shall be selected so that its total rapacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: i 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Flodda-registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance fumaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R4037.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment rapacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shag comply with Sections ❑ C403 and C404 of the IECC--Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the healer thermoslaL Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning Ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at ❑ the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 1012512019 9:23 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandatorype energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ❑ R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 10/25/2019 9:23 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SUNSET KEY MODEL_PEPITONE_2019 Builder Name: PORT ST LUCIE PROPERTIES Street: 6004 HICKORY DR Permit Office: City, State, Zip: FT PIERCE, FL, 34982 Permit Number. Owner. Jurisdiction: W Design Location: FL, ST LUCIE_CO_INTL x o COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Alr-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation In any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doers to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous act nment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including Insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the xrawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cot neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind oinino and wirino- Showerftub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exteriorwall tubs shall separate them from the showers and tubs. be Insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/25/2019 9:23 AM EnergyGaugeG USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2011 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit A Job Information Builder: PORT ST LUCIE PROPERTIESommunity: Lot: NA Address: 6004 HICKORY DR City: FT PIERCE State: FL Zip: 34982 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2.. 0 PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the. selected ACH(50) value, as showmon.Forg R405-2017,(Performance) orR406-2017 (ERI), section labeled as infiltration, sub-section.ACH50. ACH(50) specified on Form R405-2017-Energy Cab (Performance) or R40& 2017 (ERI); 6.000 I x 60 + 14418 — Method for calculating building volume: CFM(50) Building Volume ACH(50) Q Retrieved from architectural plans ElPASS 0 Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated must be verified by building department R402A.1.2 Testing. Testing shall be conducted in accordanoevrith ANSURESNETIICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shag be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Slatues.or Individuals licensed as set forth in Section 489.105(3)(f), (g), or (I) or an approved third party. A written report of the results of the test shall be signed by the parry conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be dosed, but not sealed• beyond the intended weathersbipping or other infiltration control measures. 2. Dampers Including exhaust, intake, makeup air, back draft and flue dampers shall be dosed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the lest, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, If installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester. Date of Test: Printed Name of Tester. License/Certification #: Issuing Authority: 10M 2019 9:23:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page t of 1