HomeMy WebLinkAboutBuilding PlansrxlKt
rRV1v1 I GI.LVj%I iVlr '
SCALE: 111 1-0
11
STOM MODEL FOR.
i ROZA BUILDERS, INC.
VERMONT SD
STEVEN DUNN
0 SLASH PINE TRAIL
FT. PIERCE, FL 34951
WINDOW DOORCHAFIT
VERMONTSD
ROUGH OPENING SIZE
UNITDIMENSION
W
H
W
H
UFACTOR
SOLARHEATGAIN
(INCHES)
(INCHES)
(INCHES)
(INCHES)
13080€NTRY
20468ATHERMATRU
38-3/8
98-2/2
37-5/8
98
0.14
0.01
5
SH25
FL 16177.1 IMPACT CWS
37-3/4
63
37
63
0.31
0.19
114
SH2S
FL161771IMPACT CWS
74-7/8
63
74-1/8
63
0.3
0.19
1
SH H32
FL161771IMPACT
CWS
27-1/4
26
26-1/2
26
0.3
0.21
SH24
FL 16177.1IMPACT
CWS
37-3/4
505/8
37
50-5/8
0.3
0.21
15068
SGD
FL 11103.1 IMPACT
CWS
61-1/2
80-3/4
59-1/2
79-1/2
10.33
10.26
2SH35
FLU103.1I
pAcirms
53-7/8
63
53-1/8
63
10.3
10.21
132"XW'TRANSOM
FL11103.11
PACTCWS
34
112
32
10
10.28
10.21
12868
120468.4THERMATRU
34-3/8
82-1/2
33-5/8
82
10.14
10.01
ST. LUCIE COUNTY BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
BUILDING PERMIT
OWNERS NAME
}
CONTRACTOR GR02A BUILDERS CONTRACTOR'S ADDRESS 511 SW PORT ST LUCIE BLVD
PORT ST LUCIE FL 34953
OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FD(ED GLASS, WINDOWS & SKYLIGHTS
FL= OR MIAMI-DADE
PRODUCT
MODEL NUMBER
MANUFACTURER
GLASS DESCRIPTION
METHOD OF ATTACHMENT
BUILDING 0 I N
PR UCi GN
PRESSURE
PRESSURE
FL 16177.1 IMPACT
WINDOWS
SH8100 PVC SINGLE HUNG
CWS WINDOWS
IMPACT
J" Tapoons, 1-1/4" Min. Embed in
SEE ELEVATION PAGE
+/- 70 PSF
SINGLE HUNG
IMPACT
LOW-E 366 INSULATED
Head & Jamb, in all mfg. holes
IMPACT
r Tapoons, 1-1/4" Min. Embed in
SEE ELEVATION PAGE
+J- 60 PSF
FL 11103.1 IMPACT
SLIDING GLASS DOOR
8900 PVC SGD
CWS WINDOWS
LOW{ 366 INSULATED
Head & Jamb, In all mfg. holes
?r" T.C. at 14" O.C. 1-1/4" EMBED AT
SEE ELEVATION PAGE
'0 PSF
50 PSF
20468.4
FIBERGLASS FRONT DOOR
T}IERMA TRU
6" FROM CORNERS
+/- 45 PSF
17-M19.12
GARAGE DOOR 16'W
am/811
DAB
P AG ANGLE TO HAVE (3) & x 1.5/8' Las SCREWS
AND DOOR BRACK rTO HAVE LAG SCREWS 24" D.C.
SEE ELEVATION PAGE
+27.0/-30.0
GARAGE DOOR 8'W
8241811.:
DAB
MAX AND 6" FROM CORNERS
FL= OR MIAMI-DADE
MODEL NUMBER
MANUFACTURER
-' .METHOD OF ATTACHMENT
BUILDING DESIGN
PRODUCT DESIGN
PRESSURE
PRESSURE
MULLIONS
R--9520.1
-
METAL ROOF
SHINGLE ROOF
16-0329.13
IKO
6 ROOFING NAILS PER TAB, CLASS F OR H
SIDING
SOFFIT
FL23352
Ply Gem Siding Group
2X4 BRACE AT CENTER OF PANEL - L..
+23.6/-28.8
+701-61.3
HURRICANE PANELS
-
LESS THAN 5'-T' SPAN
HURRICANE PANELS
S' 7" SPAN OR MORE
-
FLORIDA METAL PRODUCTS,
Apply roofing cement to the underside, flack and side flanges of the roof vent. Cement should be }° thick and
ROOF VENT
FL-23580.3
INC.
extend 2" onto roof undedayment
NOTE:
ALL MANUFACTURED HOLES MUST BE FILLED WITH APPROPRIATE FASTENERS
I HAVE REVIEWED THE ABOVE COMPONANTS AND CLADDING AND HAVE APPROVED THEIR
USE IN TEH STRUCTURE TO PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORCES DATE:
SPECIFIED BY CURRENT CODE PROVISIONS.
NAME MGNATURE
DESIGN FIRM CERT. NO
BIRDSEYE
SCALE: $rt = 11-019
TOP OF WINDOWS TO FASCIA=11-3/16" +/- W/2X4 END RAIL
REVISION
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
FILE COPY
;7 ��M,
W A T E R- A I R- L A N D
5109 Grand Palmetto Way chrisbeers@byu.net 941-628-0635
North Port, Florida 34291-8049 fax 413-687-9013
`- r I s t O p rie r Dtgrta(ly signed by Christopher a l
n la
DN c= FS U5,o=ldenTrustACUnaffiliat c
Individual, cn=Christopher D Beers,
0.9.2342.19200300.100.1.1=A0109800
�r 1
R ° Beet' ( 00163D5C505KO0009BOA
✓ Dater 2020.03.24 08:40:00 -04'00'
CHRISTOPHER D. BEERS, P.E.
FLORIDA LICENSE NO.64594
Although every effort is made to
ensure the accuracy of these
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown.
Bluestteant Design Studio will
not be held liable for any errors
or omissions on these plans.
-aidu
BLUESTREAM
DS
DESIGN
STUDIO
Residental CAD DIraffing
3D Ren Brings
Graphic Desgn Services
Pon: Orange, FI
(386)k256-8978
Port Charlotte, FI
(941) 275-9931
www.bluestreamdesignsLudio.com
CAD@bluestreamdesignstudio.com
ra
W
U in
Z J
u-
Q�
(Qjj W
N
® .J
d
•-I
L62
v
Z
cn
!n
m
Design and layout or concepts
for this design were provided to
Bluesheam Design Studio by
the builder shown. Any
similarities to other plans or
blueprints is solely the
responsibility of the builder.
Plans may not be reproduced or
copied without the express
written consent of the Builder
shown.
DATE
3/13/20
DESIGN BY:
LBEI
CHECKED BY:
TMB
JOB NO.
VERMONT SD Pe
REV
DESCRIPTION
I
PI09/27/19
2
P210102/19
3
P310125/19
4
P411106119
5
P5 02(26/2020
6
P6 03/11/2020
7
8
J
U)�}
_!
ZWU..
Z Lij
0CLr)
o >gEL
d > ccnC)L
SHEET
C1
COVER
SCALE:1/4" = 1'-0"
1 OF 8
nit set
4
FOUNDATION NOTES
ALL CONCRETE SHALL HAVE A MIN. COMPRESSIVE
STRENGTH OF 3000 PSI ® 28 DAYS FOR FTG'S & SLABS
REINFORCING STEEL (REBAR) SHALL BE ASTM. GRADE 60
DEFORMED BILLET STL. CLEAR COVER SHALL BE 3" FOR
FOOTINGS & 1-1/2' IN BEAMS. LAPPED STEEL MIN 25". 10" STD.
HOOKS W/ 90 DEGREE BENDS.
FTGS SHALL BEAR ON UNDISTURBED SOIL A/0 PROPERLY
COMPACTED FILL (2000 PSF MIN.). FILL MATERIAL SHALL
BE COMPACTED TO 95% DENSITY OF A STANDARD PROCTOR.
TO BE VERIFIED BY GENERAL CONTRACTOR/OWNER.
ELECTRIC SERVICE GROUND TO BE BONDED TO FTG STEEL
CONTRACTOR TO VERIFY ALL HOSE BIBB LOC. & TYPE
CONTRACTOR TO ROUGH IN A/H CHASE A/0 DRAIN
LINES, & CONDUITS AS NEEDED
CONTRACTOR TO VERIFY A/0 PROVIDE FOR SLAB
RECESSES, SILLS & CURB REQMTS 0 ALL DOORS
CONTRACTOR TO DETERMINE ANY SLOPE OF SLAB REQMTS
LAP ALL HORIZ FTG REBAR 25" MIN
ALL STL MIN. GRADE 60
BOTT OF FTG MIN 12" BELOW FINISH GRADE
ALL CONSTRUCTION SHALL BE IN ACCORDANCE
WITH THE FLORIDA BUILDING CODE 2017 ED AND
LOCAL CODES AS THEY MAY APPLY
N
lV
' t 2) #5 BARS COMlN0005
W/ 25" MIN LAP & #5
VERTICAL BAR @ CORNER
(SEE FOUNDATION PLAN)
FOOTING CORNER DETAIL
MINIMUM 12" SLOPE 116 MAX �:51FLA
OF FOOTINGBELOW GRADE 16".
JI 6"MIN
3" MIN COVER ��
F I 3" TY I� 16"_!43 TYP
MONO EDGE FOOTER
FINISHED FLOOR
ELEVATION 6
#5 REBAR
CONTINUOUS
CH) WEDGE ANCHO • �jy
I X16" �1 6',6" WIRE
STEP FOOTER (2)#5 REBAR MESH OR FIBER
0 SRO. WAU.S
4" CONCRETE
SLAB i
CF-I � u-• .yV
BEARING PAD EACHWAY
6 MIL POLY VAPOR
FBER-MESH
WIRE -MESH
CONCR
COV?.4C'ED FILL.
TYPICAL CONCRETE SLAB
FILL TO BE TREATED FOR TERMITES BEFORE
POURING BUT AFTER PLUMBING. ROUGH IN.
TERMITE NOTES:
1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND
NEED FOR RE -INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE
PROVIDED.
2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1•-0" AWAY
FROM BUILDING SIDE WALLS,
3. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL IS
COMPLETE.
4. MINIMUM 6 MIL VAPOR BARRIER MUST BE INSTALLED TO PROTECT AGAINST
RAINFALL DILUTION.
S. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE
WITHIN V-0" OF THE STRUCTURE SIDEWALLS.
6. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER
CONSTRUCTION.
7. A CERTIFICATE OF COMPLIANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT
BY A LICENSED PEST CONTROL COMPANY BEFORE FINAL INSPECTION.
MINIMUM 12" T SLOPE 116 MAX
OF FOOTING
BELOW GRADE 16"
'F1A
-` 6" MIN
(2) #5 REBA
F I CURB 3" MIN COVER
3"TYP-61 16„ I+-3"TYP
TYP FOOTING
W/CURB SCALE: NYS
MINIMUM 12"
OF FOOTING
BELOW GRADE
16"
(2)1
3" MIN COVER
F3 CURB
FLAT TOP FOOTING L16"-J
WICURS $�F: NTH
MINIMUM 12" SLOPE 116 MAX _ 4" SHOWER
OF FOOTING RECESS
BELOW GRADE 16" '
FLARE
(2) #5 REBAR-- 6" MIN
F I S 3" MIN COVER
3" TYP. I 43" TYP
MONO EDGE FOOTER W/
RECESS SHOWER SCALE: NTS
TUB `rz �` `2" BATH 2
WC f---3" 2" VENT C.O.
�r
LAV 2„
2"
�--LTUB
2" VENT C.O. 2" ,' SHOWER
I
I i LAV
2",
MASTER BATH
3" - 3---
' WC LAV
2" VENT C.O. KITCHEN
I
I
I
3" Lj SINK i
WASH U TIL i 2" i DW
1 I �
Lr ;
`--------- I,
I•
3"
1
` I
I
`J
I
,I
13"
1
I
• I 4"
4" 2 WAY C/O
REVISION
V
TO SEWER SYSTEM
OR APPROVED SEPTIC
SYSTEM
PLUMBING RISER
N . T. S. REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
NOTE:
PLUMBING CONTRACTOR TO VERIFY
PLUMBING LAYOUT AND RISER DIAGRAM.
PLUMBING CONTRACTOR TO FILE COPY
VERIFY PLUMBING WALL LOCATIONS
W A T E R- A I R- L A N D
5109 Grand Palmetto Way chrisbeers@byu.net 941-628-0635
North Port, Florida 34291-8049 fax 413-687-9013
hristopher
1 Beers
ON: c=—US, o=ldenTrust ACES Unaffil
Individual, cn=Christopher D Beers,
0.9.2342.19200300.100.1.1 =A01 09E
00163D5C505EC00009BOA
Date: 2020.03.24 0838:47-04'00'
CHRISTOPHER D. BEERS, P.E.
FLORIDA LICENSE NO.64594
Although every effort is made to
ensure the accuracy of these
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown-
Bluestream Design Studio will
not be held liable for any errors
or omissions on these plans.
1
I II>,•�, II' � i
DESIGN
STUDIO
Port Orange, FI
(386) 256-8978
Port Charlotte, FI
(941) 275-9931
Design and layout or concepts
for this design were provided to
Bluestream Design Studio by
the builder shown. Any
similarities to other plans or
blueprints is solely the
responsibility of the builder.
Plansmay not be reproduced or
copied without the express
written consent of the Builder
shown.
DATE
3/13/20
DESIGN BY:
EBB
CHECKED BY:
TMB
JOB NO.
VERMONT SD Pe
REV
DESCRIPTION
1
P109/27/19
2
P210102/19
3
P3 10/25/19
4
P411/06/19
5
P5 02/28/2020
6
P6 03/11/2020
7
8
J to
U CAM
I- ZwLL-
Z �ZL1i
�d0
W W
a
W I— N H
to o u-
SHEET
Al
FOUNDTION
SCALE: 1/4" = V-0"
2OF$ _7J
t set
Although every effort is made to
ensure the accuracy of these
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown.
Bluestream Design Studio will
not be held liable for any errors
or omissions on these plans.
"Aib
BLUESTREAM
<@Ds DESIGN
STUDIO
Residental CAD Drafting
3D Rendedngs
Graphic Design Services
Port Orange, FI
(386) 256-8978
Port Charlotte, FI
(941) 275-9931
www.bluestreamdesignstudio.com
CAD@biuestreamdesignstudio.com
llt
in
J M
Z 1,L
J�W�yy
d
t/1
0
Lr)
ur a
V
Z,
U)
N
Q "
m
Design and layout or concepts
for this design were provided to
Bluestream Design Studio by
the builder shown. Any
similarities to other plans or
blueprints is solely the
responsibility of the builder.
Plans may not be reproduced or
copied without the express
written consent of the Builder
shown.
DATE
3/24/20
DESIGN BY:
LBB
CHECKED BY:
TMB
108 NO.
VERMONT SD Pe
REV
DBOUPTION
1
P1 /27/19
2
P210/02/19
3
P310125/19
4
P411/06/19
5
P5 02/28/2020
6
P6 03/11/2020
7
8
i,
r
r
J iCJ'
F M
C0
z W l-
_�CLW
0 U -
�j
W Co tail
.N
> 4
CL �LIJ
n�jF-
SHEET
A2
FLOOR PLAN
SCALE: 1/4" = V-0"
30F8
It set
:MAND CALCULATION
VA/FT = 3 VA X 1777 5331 VA
UITS 4500 VA
5000 VA
ISM VA
1500 VA
400 VA
1200 VA
4500 VA
12000 VA
1200 VA
720 VA
JER 600 VA
486VA
'
_ __------------------------__ _
900 VA
_ '
[EATER 4500 VA
-
9000 VA
53331 VA
'
10000 VA
17332.4 VA
15000 VA
TOTAL 42332.4 VA
240 VOLTS
IR
LCULATIONS
176.385AMPS
____________________________________________
,
TENTS
USE 200 AMP SERVICE
1
1
L
1
\
NOTE:
/ /
\ `\
hand
PREWIRE FOR POOL EQUIP. FIELD VERIFY
`♦\
i
,
head
FAN/LIGHT
PREWIRE
i
pusntr
INSTALL LIGHT
PREWIRE FORONLY
t 1
t
FUTURE HOT
�♦
_
TUB. FIELD
I
ELECTRICAL LEGEND
ELECTRICAL
SYMBOL
Calling Fan Light Combo Rough In
f A
l ,
11 -7
�.
recess can It
recent can It vapor proof
extuior light Ol standard
Light F[wreseent
1
Disconnect
AC unit junction 220V
mno.
Disposal Outlet
,l{I
�vL®vv
Exhaust Fan
Outlet 220 V
Prewire For GOO
GDO
Range J I IOV At 220V outlet
grymllA
cable or Outlet
dishwasher outlet1110v
dryer 220V outlet
electrical meter
E3
electrical panel
light
{ }
oudei
outlet ga
}�T�
nutlet Wp
kl
pull chain. light
'fFC
push button gdo
T
refrigerator outlet
smoke and co detector
s�co
split receptacle
III
Switch
switch 3 way
'..
3
telephone outlet
Ph
4
washer outlet
,H,
water heater junction 220%,
n
wall mounted 031 light
L- - -
`
It
,♦
VERIFY
GRr
,
NOTE
PREWIRE FOR WELL EQUIP. FIELD VERIFY
.`. 1
` r ',
♦
PLANT SHELF •
L------ -- - - --
i -
---- i---"--"'----
I
1
r
'
/
``
PLAATT SHELF
w
I
♦
frN�
-
------------- ' ,
�'
♦ 1 ,
, I
/
NOTE: exhaust in bathrooms exhausted
♦
� _ -
,
1
•♦
/ // / •�•� •<
i
directly to outdoors
'' ` ®
`♦
/ / ♦ ♦ j
1
'
i
0
RJ
I
I
1
An
sp
o
r--_c-------Co �
it
it
J
/ ♦
n 1
PLANT SHELFtit
I
/
O
NOTE: FIELD VERIFY
�/
�`
/' -(�-.
.`
I
GASTANK/LINE 26
LOCATIONS
♦`
�♦♦
i/ / . . i
, i ♦�
6
,
�`
1
Vent fortankless
1
I
gas water heater.
HB
1. 1 Am 1 I
L _ _ "LEI
t /
♦
1
I
CRESSq-
8F
I
--r-_
1
GF1
WATER liFA76r
�-a{'
CRASH °POLE
___-
----
r -
ry.p
G�
GDO
,
uJ7
GFI
FIELD VERIFY GAS LINE FOR FIELD LOCATE METER AND
- ------------------
,
c
FUT URE GENERATOR PANG
- - - _ _ _ _
-- - . / ,
NiTRANSFERSU2TCHF0R 'i -`i --- - '"_
FUTUr GENERATOR
GRINDER I
is
,
Although every effort is made to
ensure the accuracy of these
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown.
Blueshram Design Studio will
not be held liable for any errors
or omissions on these plans.
BLUESTREAM
nc I DESIGN
Residental CAD Draffing
D Ren n
_ Grep Ic Ign rnces
Poll Orange, FI
(386) 256,-8978
PortCharlotte, Fl
(941) 275-9931
www.bluestreamdesignsWdio.com
CAD@bluestreamdesignstudio.com
m
LU
Zj 0
LLLL
U
v+
N
Ln 2u�
sthrooms exhausted
awe
LLj
4d '.105
��
200 AMP OVERHEAD
ELECTRIC SERVICE
PRIMARYr°
SERVICE SY
11r rat Pipe
POWER CO.
200 AMP
SERVICE
200
AMP
METER
O kID.
SIZE SERVICE 200 AMPS
k-#B
Y' PVC/14 COPPER TO t1piTS
CONDl1CfOR SIZE 2/0 CU
@ OUTLETS
PER
PER
METER CAN ONLY
CODE #4 Bare cofIo COPPER TO WATER NEATER
t0 ArmOfCOPPER TO RANGE
CONST. TYPE RESIDENTIAL
with one ground
rod 6' away
ELECTRICAL RISER
REVISIO"N
NTS
I.
ELECTRICAL CONTRACTOR TO VERIFY SERVICE REQUIREMENTS
2.
200 AMP SERVICE
3..
ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/
REVIEWED FOR
APPLICABLE PROVISIONS OF THE NATIONAL ELEC CODE, LOCAL
CODES, AND THE LOCAL POWER CO.
4.
CODE COMPLIANCE S.
SMOKE DETECTORS ARE REQUIRED
CAR" MONOKIDE DETECTORS AS REQUIRED
ST. L UCIE COON A 1 6.
FIELD VERIFY RECEPTACLE LOCATIONS
7.
ALL RECEPTACLES NOT REQ D TO BE GFI SHALL BE ARC FAULT
BOCC
PROTECTED PER NEC 210.12
8.
ALL RECEPTACLES TO BE TAMPERPROOF WHERE REQ'D. BY NEC
406.11 ARC -FAULT CIRCUIT INTERRUPTER SHALL BE INSTALLED
IN A READILY ACCESSIBLE LOCATION
9.
RECESSED LIGHTING FIXTURES MUST COMPLY WITH FLORIDA
ENERGY CODE 6D&1ABC. 1.2.4, PRODUCT APPROVAL (TOTALY
ENCLOSED,
10.
FILE COPY
DISHWASHER OUTLET. TO BE UNDER SINK FOR ACCESS
11.
.EXHAUST IN BATHROOMS EXHAUSTED DIRECTLY TO OUTDOORS
12.
WIRE FOR GARBAGE DISPOSAL WITH SWITCHED OUTLET
13.
KITCHEN OUTLETS TO BE GFI
14.
FIELD VERIFY WELL PUMP AND AC EQUIPMENT LOCATIONS
IS.
ALL LIGHTING FDRURES, RECEPTACLES AND LIGHT SWITCHES
- -
MUST COMPLY WITH ART. 410 OF NEC
16.
W/P GFI OUTLET WITHIN 25' OF AC COMPRESSOR
17.
WIRE FOR GARAGE DOOR OPENER
18.
ALL SWITCHES WITH DECORA ROCKER
19.
WIRE FOR VENTLESS MICROWAVE, OUTLET IN CABINET ABOVE
MUST BE HOME RUN
20•
IF NEC, PREWIRE FOR MIN SEWER ALARM BOX OR DOZER SEPTIC
SYSTEM (FIELD VERIFY)
21.
ALL SMOKE DETECTORS MUST BE A MINIMUM OF Y FROM ANY
BATHROOM DOOR
22.
ARC FAULT PROTECTION TO BE USED IN ALL BEDROOMS
23.
ELECTRICIAN TO SUPPLY ALL SMOKE DETECTORS AND DOOR BELL
CHIMES
24.
ALL CHANGES MUST BE DONE IN WRITING BY GROZA BUILDERS,
INC. HOME OWNERS DO NOT HAVE THE RIGHT TO CREATE
CHANGES WITHOUT DOCUMENTS
I . .
Design and layout or concepts
for this design were provided to
Bluestream Design Studio by
the builder shown. Any
similarities to other plans or
blueprints is solely the
responsibility of the builder.
Plans may not be reproduced or
copied without the express
written consent of the Builder
shown
DATE
3/13/20
Tilt set
DESIGN BY:
LBB
CHECKED BY:
TMB
JOB NO.
VERMONT SD Pei
REV
D6CIRIPRON
C/)
I—
ZWLi-
z
5ZW
U
Wt=/1W
W
SHEET
A3
ELECTRICAL
SCALE:
1/4" = V-0"
40F8
Although every effort is made to
ensure the accuracy of these
I
ROOF VENTING CALLS PER FBC R806
TOTAL ROOF AREA 3193
VENTING REQUIRED 3193SFX144SQIN/SQFTX1/300SQINVENT/SQINROOF =
1533SQIN
10.64333333 SQ FT VENTILATION REQUIRED
40%MINIMUMINUPPER ROOF = 4.2573333SO. FTREQUIRED
ACHIEVED WITH 4' LONG OFF RIDGE VENTING. ACTUAL FREE VENT AREA =.72 SQ FT/4' VENT
6 TOTAL REQUIRED WITHIN 3'-0" OF MAIN PEAK =
4.32 SQ FT
REMAINDER TO BE ACHIEVED WITH VENTED VINYL SOFFIT
20.64333333 - 4 32 _
6.3235 SQ FT REQ`D
AS PER IVANUF.SPECS VENTED VINYL SOFFIT IS 6.2 SQ INAIN FT= .043 SQ FT PER UN FT. TOTAL SOFFIT LF=
268 X 0.043 = 11.52 SF
TOP OF WINDOWS TO FASCIA=11-3/16" +/- W/2X4 END RAIL
TOP OF. WINDOWS TO FASCIA=11-3/16" +/- W/2X4 END RAIL/ - -
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown.
Bluestream Design Studio will
not be held liable for any errors
or omissions on these plans.
�_�i�lllll;ll�l'
�, t �
Residental CAD Drafting
3D Renderings
Grap tl ic Des" Services
Port Orange, FI
(386) 256-8978
Port' Charlotte, FI
(941) 275-9931
www.bluestreamdesignstudio.com
C.Ao@blue5treamdesignstudio.com
V M
N'f
J
LLLL
LU
+37.51 .. �J
-40.7 .'. +36.0-48.7
� / +36.9/
-39 2 y
"�. 0'-0"FiniahFloor j
Finish Grade
n w n e� wrnw ..
wr
-40.5 9
-- � I —r I I
i-I" Truss B i
REVISION
written COnaart of the Builder
shown.
®
®®
DATE
3/13/20
+38.0/
DESIGN BY:.
LBB
-41.2
CHECKED BY:
TMB
TOP OF WINDOWS TO FASCIA=11-3/16'° +/- W(2X4 END RAIL
01
_
JOB NO.
VERMONT SD Pe
it set
G
+43o6/
REVIEWED FOR
a-o"Finish Floor
CODE COMPLIANCE
REV
DEsauPnoN
Finish Grade
LEFT
SCALE:
- +362/
ass
ELEVATION
-Orr
q
� -
5F,
__:_
tit I I I i ;—IRnaF I
ST. LUCIE COUNTY
BOCC
FILE COPY
1
P109/2719
2
P210// 19
3
26/19
P11110/O6/19
¢
P4
5
PS 02/28/2020
6
P6o3/tv2020
7
FE3WATER -AIR -LAND
TOP OF WINDOWS TO FASCIA=Il-3l16" +/- WAX4 END RAIL = +375/
5109 Grand Palmetto Way chdsbeers@byu.net 941-628-0635 LU LLL
North Port, Florida 34291-8049 fax Z 4 -
Digitally signed by Christopher D Beers ' �"' 0 �, it
DN: c=US, �IdertTrust ACES Unafflliat 0) u1 W
�/� p , Christopher g a
Individual, cn=Christopher D Beers, p tL
Finish -^W
++36s0.9.342.19200300.100.1.1=A01H o LFL
0-o"Finish Floor 0163D5C505E00000960A n Beers
Date: 2020.03.24 083638-04'00`
K SHEET
RIGHT ELEVATION `L R,.. ~ A4
gip'' CHRISTOPHER D. BEERS, P.E. ELEVATION
SCALE: 4n = 1'_011 r , FLORIDA LICENSE NO.64594 SCALE; 1/4" = V-0"'
5OF8
CONNECTOR TABLE
FASTENING INFORMAT ON
ADDITIONAL INSTRUC710NS
51MPSON USP UPLIFT a6N
WOOD TO WOW
HT520 HTW20
1454
20 10D NABS TOTAL
2 HT520 2 HTW20
29DO
20 tOD NAILS LACK STRAP.
9 10DX7-1 LK a 810D TOP
Nm
TE
HI OA RT16A
SPH4 SPTH4 6
1140
1360
72 N WRY
WOOD TO CONCRETE
7 1WX1-i 2 NAILS 3 4" EMBEDMBHT
TYP FOR HIP JACKS OR 1-PLY TRUSSE
META20 -
1450
70 1ODXI-1 2 NAILS 3: 4 EMBEDMENT
TYP FOR HIP JACKS OR 1-PLY TRUSSE
HUA20 -
1810
10 10DX1-1 2 NAILS & 4' EMBEDM�7T
lYP FOR HIP JACKS INC 1-PLY 11
HTA16
HTW20 HTVM20
1870
1175
!2 tED NAILS k 4 t 4"X2-3 4" TAPCONS
TYP FOR MISSED STRAPS NO UMI
TYP FOR i-PLY TRUSSES GIRDRS
2 META2 -
1985
5 tODX1-1 2 NAILS EACH STRAP
NAILS EACH STRAP & 4" EMBEDMENT
T"!P FOR 2-PLY 1RU55E5 G88)ERS
211 HETA2
25pp
7 18D
EACH STRAP & 4" EMBEDMENT
TYP FOR 1 cr 2-P!Y TRUSSES qR
2 HTA76
2430 110
10D NAILS
OTHER CMNLUImb
5 8" klR ITABED fi" & 22 50D NAILS 10
ADD 4 TO ED EMBFOR LINTEL BEAMS
MGT MUGn5
----
9780
2 3 4' ATR EMBED 10" & 8 16 FOR H IUD NAILSADD 4" TO EMSED FOR LINTEL BEAMS
HOT HUGT
FGTR
5000
2 1 2'X5' TRITE HD & 18 SOSI 4X3 TO WO D MAY BE FGTRHL 3850 MAX UPU
AY BE 2 FGi18iL 7200 MAX UPU
2 FGTR
940D
2 1 2 W TITEN HD g 18 5D5t 4X3 TO W000
5 ATR EMBED 6- & 18 16D NAILS lD
EA
ADD 4 TO EMBED FOR LINTEL BEAMS
HTT4 H114
4235
is
5 ATR EMBED 6' & 26 16D NAILS TO
ADD TO BEAMS
HTr5 HTTS
5090
7630
7 B ATR QED 12' d: 20 3" WOOD SCREWS
3 1' Mar WOW mt,MuER
HDOB-SDS PHDB
11 0 -
1' AIR EMBED 12" do 24 3 WOOD SCREWS
5 1 4 Mai W0� MEMBER
HHDQ71- UPHD9
HH0014-SD UPHD14
73710
1' AIR EMBED 12' k 30 3" WOOD SCREWS
'III
5 1 4' MIN WOOD MEMBER
ON PLPALNYS
MBHA NFMXXU
3165
3 4'X8" AIR EMBED FACE k q 114"TOP FOR
N%NEER a REPMR Aait
RPS22 KRPS22
7720
8 16D NAGS EACH END
GENERAL NOTES
1) NAILING MAY BE REDUCED FOR LOWtJt UPUFIS. PROVIDE (i) 10DX1-t/2' NAIL FOR EA 100 U35OF UPLIFT (4 NAILS MIN).
USE MAXMUM UPLIFT 1175/. FOR UPLIFTS
2) MISSED STRAPS PROVIDE HTSM20/MTVM20 1-1/r MIN EDGE DISTANCE. UNUMITED.
TO 3965M PROVIDE MUGT15/MGT
SPECIFIES REFERENCED
STRAP FOR 1-PLY TRUSSES, ADD 24" MIN 2X SCAB TO TRUSS CHORD
3) WHERE ENGINEER
ON PLAN V4TH EQUAL OR BETTER PER THIS TABLE IS ACCEPTABLE
4) REPLACEMENT OF CONNECTOR
101 0$1
Maas Uplift 3=11(LC 1). 2-110¢c 8
CJ
Max Uplift 3=-66(LC 12),2-117(LC
WE
Max Uplift 3-128(LC.12), 2-123(LC
Max Uplift 3=-161'.(LC 12), 2=140(LC 12
EJ7
Max Uplift 3-161(1-C 12). 2-140(LC 1
EJ7
Max Uplift 3=-161(LC 12), 2-140(LC 12
EJ7
Max Uplift 3-161(LC 12). 2-140(LC12
Max Uplift 3=-161(LC 12), 2=140(LC 2
0 F
Max Uplift 3-1O1(LC 12), 2-140(LY,
EJ7
Max Uplift 3=-161(LC 12), 2-140(LC 12
E,171
Max Uplift 3=161(LC 12), 2=14G(LC 12
EJ
Max Uplif3=-161(LC 12), 2=-140(LC 12
ER
Max Uplift 3=-161(LC 12), 2=14O(LC 12
1-HETA20
EX
- Max Uplift 3=-161(LC 12), 2-140(LC12
EA
Max Uplift 3=-161(LC 12), 2=140(LC 12
EX
'Max Upl(Ity3=161(W 12), 2=14o(LC 1
y EJ71
CJ1
-
Max Uplift 3-1
LC 1),
1 1O(LC
8
CJ
Max Uplift
14 2
11ALC
CJ
Max Uplift 3-1
C 12),
-123(L (
8
EJ
Max Uplift 3-
161 (LC
2),
-
Max Uplift 3-
61(LC
)• EJ7
-
2=140(LC 12
v
Max Uplift 3-1
(Lc,4E
EJ7
2= 4140(LC 12
tV
ER
Max Uplift 3-1
(LC 12
2=140(LC 12
Max Uplift 3-1
1(LC '12
EJ7
2=140(LC 12
Max Uplift 3=1
(LC 12
2-7
I
Max Uplift 3=4H
(LC 12),
-117(L
8
CJ
Max upift
1(LC 1
2-11
CJi
�1
3
7s 0"
V2
V3
V4
m
V4
-
iV
N
m
m
1'�i
e�1�t7
tqa
p
i4
N N
N
N
N
aH
.r
a
d
�
eS
1�1
O N
!1 11
N
•
I�
�
"
7 cY v
71 n 1 0" f of 1 On 10n 1 0x f on, 1 0- 1 0"
30' "
1-HEfA20
71 011
Im
ER
Ix UpIiR 6= 90(L 5), 2'-590 L 4
w Uplift 9=-244(LC 9), 6-234(LC 8
ax UR(ift 8=213(LC 9), 5=-218(LC/"
8'-1" CLNG
EJ7Q
Uplift:
2--140(LC
CE
Q. G Q
--161(LC 12F Q
12 V
EJ7
W
Max Uplift
2-140(Lc
ER
=161(LC 12), r
12 0 ,r-f
T-4
Max uplift
2=14O(LC
161(LC 12)-cq -
2
EJ2
E.17
�5
Max Uplift
-16(1.10 12),
2-14G(LC
ER co
Max U
12 2
ID
- 161(LC 12M -
2=1
12
EJ7
Max Upat
- 161(LC 12).
l]
2=-140(LC
12 -
EJ7
Max I
pfift3=-129(LC 12), 2-123(LC
CJ5
Max
I iplift 3=-65(1-C 12), 2-117(LC 8
CJ3
Max U
ift 3-11(LC 1), 2=41O(LC 8
CJ1
U
10, oil 7' 011
'
Max Uplift
11(
1),
-11
CJ1
Do
OD
Max Uplift 3=6
LC ),
2
117
CM
. Max Uplift 3-
280 P
12
2-1
CJ5
EJ7
Max Uplift 3=161(L
12
2=-
40(L
0
Although every effort is trade to
ensure the accuracy of these
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown.
Bluestream Design Studio will
not be held liable for any errors
or omissions on these plans.
BLUESTREAM
DS SIGN
FUDIO
Residental CAD Drafting
3D Rende- s
rapFIC Design Services
Port Orange, FI
(386) 256-8978
Port Charlotte, A
(941) 275-9931
www.bluesb eamdesignsbidio.com
c
c
mM
M
LL
UX
__..
8
)-
(LC8 N.Q
0.
TRUSS END DETAIL
Z
2 �
12
(L 1 PLUMB CUT OVERHANG 57
2
4-1116"
2 HEEL HEIGHT
C
• • 1`*i
• • • 0
L 1
C 2 m
C 12 REVISION
Design and layout or concepts
am for this design were provided to
-H ETA20 BluestreDesign Studio by
the builder shown. A"
c 1 ). similarities to other plans or
ROOF SHEETING rblueprints esponsibility
solely the
c 2), responsibility of the builder.
TAII Flan may not be reproduced or
CAD@bluestreamdeslgnsiudlo.com
LC 8
Hatc ege6d
',�'
`
'i'►I���.Mill
,
•s•OJi .�DOOi•00000•••i•OO.O•OOe•P•L•
�ililil��lr�iiils�iinlr '•' a o �
...♦«.••<.�♦ ♦..<:•.<::♦ •psi
-
4
pill
N
1
P1 09127119
2
P210/02/19
3
P3 10/25l19
4
P4 11/06/19
6.
P5 02/28/2020
6
P6 03/11/2020
8
ILE COPY
to
<t/ tU .ill W w'j Max Uplift-147(LC8j, I%
ax Uplift 2=-184(LC 1I/ {
147 LC 8), Max Uplift 3--138(LC 12), a.
184(1-C.4 2=125(LC BMLJU
e
'v
1-HETA20 WATER -AIR -LAND
J
5109 Grand Palmetto Way chrisbeers@byu.net 941-628-0635 F.
North Port, Florida 34291-8049 fax 413-6$7-9013 O a LU
gic Digitally signed by Christopher D Bee s W N W
I, l h r i st 0 p h e r DN: r-US, o=ldenTrust ACES Unafiilia ed C j g d
t`�Ci. ESSlq�4 ',r
Individual, cn�hristopher D Beers, y_ W
3' 6" 6' 4" 3° fs" 0..9.2342.19200300.100.1.1=AO1098 id. > W o LLLL.
k ad .
13' 4" _ r s 00163D5C505EC0000480A
Date: 2020.03.24 0835:41-04•'00' SHEET
" a A6
CHRISTOPHER D. BEERS, P.E. ROOF PLAN
p.C' '')P, �-' • )fir-'.�^
Jv ; FLORIDA LICENSE NO.64594 SCALE:
601`$
®®
Sr
I' •
U q'
IF OVERHANG EXCEEDS 24" NOTE: LANAI AND ENTRY PORCH
INTERMEDIATE BATTENS ARE CEILINGS ARE STUCCO FINISH
REQUIRED 12" O.C.
OVERHANG DOES NOT REQUIRE
BATONS IF 12" OR LESS
PRE-ENGINEERED WOOD TRUSSES
WITH GALV. BEARING PLATES
CP EDGE OMPOSITE S��H��INGLES ON #30 FELT OVER
Rt2" CDXX ( AVAILS AE46 INK W18d
2TTACN�WITHI 16F NAILS THROUGHOUT
ATTACH
WIRE LATH
5/8" stucco (horizontal application) and
7/8 thick stucco (vertical application) on:
3/8" hi -rib lath attached to ;horizontal and,
vertical wood framing with nails or staples
to provide no less than 1-3/4" penetration
into horizontal wood framing and 3/4"
penetration into vertical wood framing
members
AT 12" O.C. STAGGER WITH 12" OVERHANG
FASCIA NAILS
26 GAUGE (MIN.) BAFFLE/1/ENT
ALUMINUM FASCIA OVER
2x4 END RAIL' ATTACH
2x4 TO TRUSSIES WITH
(2) 12d, FACE NAILED —�-
ATTACH FASCIA WITH ROOF
NAILS AT 12" O.C.; STAGGER INSULATION R-30
DRIP EDGE NAILS
OR PER ENERGY CALC'S
PREFINISHED PERFORATED 5/8" DRYWALL OR
VINYL SOFFIT- ATTACH V(2" CD. BOARD CLG.
TO WALL WITH "F" CHANNEL
USING'T-NAILS" AT 16" O.C. (MIN. SINGLE 8" U-BLOCK WITH (1)
A`ND $ATTEN`WITH 0.12" DIAMETER
1-1/2" LONG, SMOOTH SHANK NAILS/
(LE., 4d ROOFING COIL NAILS)
AT 121, O.C.
HURRICANE STRAP @ EA. TRUSS;
ALL STRAPS TO TRUSSES SHALL
BE AS DESIGNATED ON PLANS
VERTICAL REINFORCING - SEE PLAN
FOR LOCATIONS. 1- #5 RE -BAR TYP.
UNLESS NOTED. FILLED W/ 3000 PSI
CONC. STD. 900 HOOK TOP & BOTTOM
MIN, 25" LAP. PROVIDE INSPECTION
HOLES. WINDOW --"
#5 RE -BAR TOP CONTINUOUS
IN EACH U-BLOCK
C
ro
N
N
BLOCK FILLED INJECTED
FOAM INSUALTION
1/2" DRYWALL OVER
1X2 P.T. WD. FURRING
8"x8"X16" CONC. BLOCK WOOD BASE
4" CONC. SLAB,:. 2500 PSI, -W/
DECORATIVE FIBERMESH OR��'AX6X10/10 WWM
CEMENTIOUS BARRIER W/ TAPED & LAPPED
COATING (1) COURSE 9" BLK JOINTS, OVER TERMITE TREATED,
WELL COMPA DEARTH
GRADE SHALL BE
�4" BELOW FINISH �'� SIMPSON EACH DHE AIs
FLOOR LINE ///\�/\/\�/\ / • ` r \/ \\/\/\ \ Or
EACH BEAM
51
16'W X 16"H CONC. FOOTING /
W/(2) #5 BARS CONT. \� \�\\ � .. FILL MUST BE CLEAN AND
(OR A5 NOTED CO FND. PLAN) �/ COMPACTED TO A MINIMUM
OF 95% OF THE MODIFIED
TYPICAL WALL SECTION PROCTOR MAXIMUM DRY DENSITY
NOT TO SCALE
TRUSS CONNECTOR NOTES:
1. PROVIDE SIMPSON (1)HETA 20 HURRICANE STRAP
AT EACH TRUSS TO TIE -BEAM CONNECTION,
UNLESS NOTED OTHERWISE.
R703.8 Flashing.
Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water
into the wail cavity or penetration of water to the building structural framing components. Self -adhered
membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at
GENERAL NOTES:
STRAP DBL TOP PLATE TO
1) FINISHED FIRST FLOOR ELEVATION IS ASSUMED AT 0 =0" - VERIFYACTUAL ELEVATION WITH THE
EA. STUD USING SIMPSON SP
ENGINEERS SITE PLAN
PROVIDE SIMPSON HTS20
STRAPS. ADJUST THE STRAP SIZE
2) CONTRACTOR SHALL VERIFYALL DIMENSIONSAND DETAIISAND SHALL NOTIFYENGINEER
HURRICANE TIE AT EACH TRUSS
TO MATCH STUD WIDTH.
IMMEDL47ELYOICANYERRORS, OMISSIONS OR DISCREPANCIES PRIOR TO COMMENCEMENT
OF WORK.
3) ALL AMTERIALS, EQUIPMENT, CONNECTORS, AND WORK SHALL MEET OR EMCEED THE DESIGN
DATA AND COMPLIANCE CODE C2T'EO.
4) ,ENGINEER IS NOT RESPONSIBLE FOR ANYSUPERVISION DURING CONSTRUCTION.
S) THE CONTRACTOR AWNTAINS THE RESPONSIBILITY FOR ALL CONSTRUCTION MEANS, METHODS
AND TECHNIQUES REQUIRED FOR THE CONNECTIONS OF ALL ROOF, WALL AND
BEAM - SEE TYPICAL SECTION
FLOOR SYSTEMS. ALL WORK SHALL BE PERFORMED INA WORKMANLTKEMANNER.
AT BLOCK WALL
6) THE STRUCTURAL INTEGRITY OF 774E BUILDING SHOWN ON THESE PLANS IS DEPENDENT UPON
CONTRACTOR TO FILL LAST
COMPLETIONAC7rC)RDWGTOPLANS AND SPECTRC47YONS. STRUCTURAL MEMBERS ARE NOT SELF
CELL SOLID WITH CONCRETE AND
SUPPORTING DURING CONSTRUCTION AND REQUIRE 7EMPIiYBR4C7NG UNTIL PERMANENTLY
(1) #5 BAR VERT. FOR FRAME WALL
APPLIED TO STRUCTURE. 7HEARO•IITECTASSUMES NO LIABIL.ITYFOR
ATTACHMENT
THESTRUCTUREDURINGCONS77ZUC77ON UNLESS THECONSTRUCTION METHOD AND BRACINGARE
INCLUDED M THE RANSAND SPECIFICATIONS, OR ARE SUPERVISED BY7HEARCHI'TECT
2X4 OR ZX6 STUDS
TAPCON SCREWS #10 X 3"
DURING CONSTRUCTION.
SEE WALL SECTIONS
FOR APPLICABLE WIDTHS
@ 16" O.C. OR 1/2"DIM. X
5-1/2" LG. REDHEADS WJ
7 ALL MODIFICATONS TOTHE PLANS MUST BEREVIEWED AND APPROVED BYTHE ENGWEER.
AND STUD SPACING
2" DIM. X 1/81' WASHER
@ 24" O.C.
2X BLOCKING
AS REQUIRED
BY FLORIDA
BUILDING CODE
STUD ALONG BLOCK
RESIDENTIAL
WALL TO BE P.T.
1/2" X 8" WEDGE ANCHORS @ 32" O.C.
CLIP EACH TRUSS
(SEE FLOOR PLAN FOR TYPE)
W/ (2) WASHERS & NUTS
I
FRAME OUT TO
BLOCK EDGE
DBL 2" X 12" WO D BEAM
CONCRETE FOOTER STUD ANCHORING:
' STUD TO TOP PLATE,
7/16" OSB W/8d SIMPSON SP4 OR SP2
COMMONS @ W ON i
TO FRAME BEARING WALL CONNECTION LSTA16F STET / FIE'i 12"w
FIELD 18" Q.C. TO 48" HIGH
(12)10d NAILS EACH
i
2x6 SYP 616" O.C. 48" TO
NOT TO SCALE
72' IN HEIGHT
°
,
0
SIMPSON SP4 OR SP1
BEAM -SEE FLOOR
4"X4"WOOD
OR USPTP4X FROM
PLAN FOR SPECS.
POST CENTERED
2x4 P.T.
STUD TO BOT: PLATE
ON CBS WALL
•
C85 WALL,
'
LINTEL
'
POST CONNECTED TO CBS
WALL W/ SIMPSON ABU"
II -
(4)10d EACH SIDE
FASTENED W/ 1/2" X 6" TITEN HD
1/2"x8' WEDGE ANCHOR
OF 2x4 TO BEAM
AND (12) Sd NAILS INTO POST:
'.
AT 32" O.G.
'
10d AT P D.C. BOTH SIDES
_
SEE FLOOR PLAN.
FOR BEAM SPEC.
SUPPORT COLUMN
8"CMUWALL
BUILT-UP 2x4's OR
WOOD BEAM TO
' �
4x4 POST
•
.:-;
�;
WQ;I>,BdpEAOH o6'$
CBS WALL ATTACHMENT KNEEWALL DETAIL
;;;1;
TYPICAL BLOCK
POST
NOT TO SCALE NOT TO SCALE
WALL
r . - TIE BEAM
ALTERNATEHOLDOWN:
' '
'••
USE (2) SIMPSON MSTAM24
i r.
WITH (9)10d AND (5)
U4"XL-,f4" TITENS
• , _
.��,�---_-.-----_._.,,._.-�_,_._
(3) A.B. W/6"
MIN.EMB. SPACED •
%\
EQ. W/2"
HEADER
AT
RAISED
ENTRY/CMU
WALL
WASHER OR "
(4) 1 X 4-1/2
NOT To SCALE WEDGEANCHOR
ir)
" N N
s N + to
C4
ENTRY CMU COLUMN/HEADER CR"��C 2-#5 BARS CONTINUOUS BARS PER PLAN
NOT TO SCALE (SEE PLAN FOR w/25 MIN LAP & 1-#5 w/25" MIN LAP
the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C 920 Class 25 Grade LOCATIONS) VERTICAL BAR AT CORNER n
NS or greater for proper joint expansion and contraction,.ASTM C 1281, AAMA 812, or other approved (3)12d NAILS R ISIOP
standard as appropriate for the type of sealant. The flashing shall extend to the surface of the exterior wall PER JOINT
finish. Approved corrosion -resistant flashings must be installed. Sher -Crete flexible concrete waterproofer or TYP. STUCCO k 8"
equal. ILLED BLOCK 1#51X8 P.T. DOOR BUCK 6„
ATTACHED W/ 1-112"'I' NAILS CONTINUOUS BOTTOM CHORD BRACING
•: :. _ - . - :' --:a! 2x4 MINIMUM
X2 P.T:FURRIN 1/2" DRYWALL - - 14" FROM EACH END AND
BEAM CORNER DETAIL
8"O.C.(SINGLE
DBLLE LEAF)8
,2"O.K:.(DBLLEAF) CROSS BRACING DETAIL (TYP.) FOOTING AT CORNER NOT TO SCALE
BRICK MOLDINGS NOT TO SCALE
1X2 P.T. FURRING
FRAME NOT TO SCALE
HINGED SWING DOOR
ATTACH TO CONK. BLOCK C
THROUGHWOODWINDOW C %fl I L.[t A D REVI'EWEDFf OR..
BUCK W/ 3/18" X 2 3/4" TAPCONS. C IL1] J I[�,►
FILLALLHpLES:1.114"MIN EMBEDMENT C�+OTDE.COMPLIANCE
FOIL - OORJAMB ATTACHEDW/1/4"X3.1f2"TAPCONS rr [A� �71. LUCIE COUNTY
1X4 P.T. WINDOW BUCK CASING iI 6-EACH END & 18" O.C. (SINGLE LEAF) & S P E C I 1 I C A T I O N S
ATTACHED W/ 1-1/2" "P NAILS 1X2 P.T. FURRIN 12" O.C. (DBL LEAF)
VV //11 11
18" O.C. VERT 1/2" DRYWALL BR BLOCKING FOR
s ..•:.......:. BRACKETS
�.. 2x6 PT with 1/2" x 7"wedge anchors will square washers
TYP. STUCCO MOUNTING
EXT. SWING DOOR JAMB DERDO
WINDOW ATTACHMENT DETAIL
1@' DRYWALL ATTACHMENT DETAIL 2x6 P.T. S.Y.P. BI,CK.
X2 P.T. FURRIN
NOT 7O SCALE � � W ,m� D E R— A( R— L
EONE 1/2" x 1.5/$" LAG MOUNRNG
NOT TO SCALE SCREW PER TRACK BRACKET BRACKET FOR IIA
AS PER MANUFACTURER: SPRING - 5109 Grand Palmetto Way chrisbeers@byu.net 941-628-0635
1X2 P.T. FURRING North Port, FL., 34291-8049 - fax 413-487-9013
DOORFRAME
/ATTACH TO CONC. BLOCK 16" WEDGE ANCHOR 12 GA. GALV. STEEL VERTICAL TRACK TWO (MIN)Ch . ��A er5
THROUGH WOOD DOOR NOMINAL VERTICAL #5 1/4" 1UNN `1 I ' s e p DN: C=US, o=ldenTrust ACES Una listed
BUCK W/ 3/18" x 2-3/4" TAPCONS. REBAR Trva.> TYPICAL GARAGE DOOR BUCK AND VERTICAL TRACK THRU 2x BLOCK Qtt' t)'4 Individual, cn--Christopher D Bee ,
FILL ALL HOLES:1-114" MIN EMBEDMENT c INSrAlAATION.DETAIL N.T.S. LENGTH OF MINTO CMU; IN' - '.'r Y m k ' p 0.9.2342.19200300. 100.1.1 =AO 10 800000(
c CONCRETE FILLED 163DSC505EC0000960A
° GARAGE DOOR. BUCK INSTALLATION �c .-
8°"iB• � USE 2x6 PRESSURE TREATED WOOD BUCKS ATTACHED GARAGE DOOR SPRING BUCK INSTALLATION HEAD �_ A Date: 2020.0314 08.33:51-(b4"00'
1X6 P.T. DOOR BUCK WITH A MINIMUM OF FOUR 1/2" 0 WEDGE ANCHORS „
:.: • t a USE 2x8 PRESSURE TREATED WOOD BUCK 5
ATTACHED W/ 1-1/2" "T" NAILS G C.M.U.
'+ BUCK ABOVE GARAGE �''-;7r T'fi
IW O.C. VERT 8°X 16" G.M . U . DETAIL. WrTH 3" WASHERS STARTING AT 8" FROM EACH END OF SUFFICIENT HEIGHT TO DOOR OPENING; ATTACH
TYP. STUCCO D AND SPACED NO MORE THAN 32" o.c. ACCOMMODATE BRACKETS. ATTACH CONCRETE NAILS 0 4" O.C. ' "•
CONCRETE NAILS AT 4" Q.C. ci
NOTTOSCALE GARAGE OVERHEAD DOOR CONNECTION ° CHRISTOPHER D. BEERS, P.E.
S.G.D. ATTACHMENT DETAIL FLORIDA LICENSE NO. 64594
NOT TO SCALE NOT TO SCALE
I
Although every effort is made to
ensure the accuracy of time
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown.
Bluestream Design. Studio will
not be held liable for any errors
or omissions on these plans.
BWESTREAM
DS DESIGN
STUDIO
Residental CAD Dratting
D Ren Brings
Graf is Design Services
Port Orange, FI
(386) 256-8978
Port Charlotte, FI
(941) 275-9931
www.btuesb,eamdesignstudfo.com
btuesb,eamdesignstudio.com
CAD@bluestreamdesignstudio.com
m
UJ
M
U In
In
M
w
J
O
aH
N t-
O
in a
_Z
Cn
La
J
m
Design and layout or concepts
for this design were provided to
Bluestream Design studio by
the builder shown. Any
similarities to other plans or
blueprints is solely the
responsibility of the builder.
Plans may not be reproduced or
copied without the express
written consent of the Builder
shown.
DATE
3/13/20
DESIGN BY:
LBB
CHECKED BY:
TMB
JOB No.
VERMONT SD Pe
REV
DESCRIPTION
1
PI09/27/19
2
P2 10/02/19
3
P310/25/19
4
P411106/19
5
PS 02/28/2020
6
PIS03/11/2020
7
8
FILE COP
J Lo
I— Z W LL
n9L
O �
NZ
W0)w
o >Wga
11 W
> tn0�
SHEET
S1
STRUCTURAL
SCALE: Custom
90F8
nit set
1
1
25" MIN
ACTUAL CHANGE IN BEAM
ELEVATION DETERMINED IN
FIELD
CONNECT TRUSSES TO LOAD BEAR
WALL AS NOTED ON THE PLANS. 100 GENERAL
100.5 FRAMING NOTES
BEAM BLOCK
100.1 MATERIALS
100.5.1-
WINDOW AND SLIDING GLASS DOOR DOOR (I.E., SGD) BUCK INSTALLATION
SEE WALL SECTION:
100.1.1 MASONRY UNITS-
ALL WALL AND SHINGLE ROOF SHEATHING SHALL BE 15/32" MINIMUM
C-D PLYWOOD SHEATHING OR OSB.
WOOD BUCK STRIPS SHALL BE 'ONE Or PRESSURE TREATED WOOD. WIDTH SHALL BE SUFFICIENT
FOR DETAILS
CONCRETE MASONRY UM75 SHALL BE HOLLOW OR SOLID
TO EXTEND BEYOND THE INTERIOR FACE OF THE WINDOW OR SGD FRAME.
UNIT MASONRY IN ACCORDANCE WITH ASTM C 90 AND
100.5.2-
THE WOOD BUCK STRIPS MAY BE INITIALLY ATTACHED TO THE CMU OR CONCRETE WITH CASEHARD
SHALL HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH
ALL ROOF SHEATHING SHALL BE STAGGERED WITH THE LONG
1-3/4" NAILS AT-16' O.C. THE BUCKS SHALL BE FINALLY ATTACHED WITH REDHEAD 3/16"
\
OF 19M PSI. CMU MATERIALS AND CONSTRUCTION SHALL
DIMENSION PERPENDICULAR TO THE FRAMING.
TAPOONS (THROUGH THE WINDOW OR SGD FRAME) WITH SUFFICIENT LENGTH FOR A MINIMUM OF
5 HORIZ REBAR IN BEAM BLK
COMPLY WITH 'SPECITCTION FOR MASONRY STRUCTURES'
I00.5.3-
1-1/4' OF PENETRATION INTO THE CMU OR CONCRETE. THE NUMBER OF TAPGONS SHALL BE PER
SEE TYP. WALL SECTION FOR
ACI 530.1/ASCE 6-05/iMS 602-05: PART 2 & 3.
NAILING FOR ROOF AND WALL SHEATHING SHALL BE 1 Bd RINGSHANK
(�
THE MANUFACTURER'S INSTALLATION DETAINS.
- DETAILS
100.1AL MORTAR-
NABS FOR ALL SHEATHING UP THOU i/2' THICK AT 6 0.H1/2- THROUGHOUT;
PRIOR TO ATTACHING THE WOOD BUCK TO THE CONCRETE, BOTH MATING SURFACES SHALL
HAVE BEAD OF AOHESVE/SEALANT APPLIED TO BOTH SURFACES TO ENHANCE THE STRENGTH
SHALL BE EITHER TYPE M OR S IN ACCORDANCE WITH
AND (2) tOd RNGSHANK NAILS FOR SHEATHING LARGER THAN 1Jr
E
O THE JOK:L
-
ASTM C 270
THICK. NAILING SHALL BE 6" oc. AT EDGES AND 1r me INTERIOR
#5 HORIZ REBAR IN BEAM BLK
SEE TYP. WALL SECTION FOR
DETAILS #5 HORIZ REBAR CORNER BENT
IN "L" CONFIGURATION FOR
MIN. LAP ON VERT. REBAR
BEAM BLOCK
SEE WALL SECTION
FOR DETAILS
#5 REBAR
VERTICAL
CHANGE IN ` BEAM BLOCK
ELEVATION DETAIL
NOT TO SCALE
2x4 BLOCKS @ 16" O.C. FASTEN TO LOOKOUT V iWO
10d NAILS AND CLIP WITH HCLH OR H4 (IF MORE
THAN
12" OVERHANG) OTHERWISE TOE NAIL WMV010d NAILS
TO GABLE TOP CHORD
USE USP HCLH [[or L OR SIMPSON
H4 CONNECTOR AT ENDS OF CROSS
2x4 LOOKOUTS
BRACING - Ira NOT TOE NAIL
24" O.C. (TYP.)
UP TO 2' O.H
2x4'T-BACK" B
"X" BRACING (2x4) Qd MID
T VERTICALS T
EN
/
POINT REGARDLESS OF HEIGff
AND AT QUARTER POINTS IF
0.
USP HCLH (
L) OR
HEIGHT IS TOR MORE,
STEPSON H4
EXTEND BACK 3 BAYS
CONNECTOR AT
HARDI SIDING OR
XNFRI.MBGASLE
ENDS OF CROSS
TEXTURED CEMENT FINISH
BRACING - DON
TOE
ON METAL LATH & FELTPER
ASTM C1063
@ 48GABLE
END 7RU
DTRU
10d NAILS @ 6" O.C.
BOTTOM CHORDS.
INTO 2X6 PLATE
8" U-BLOCK WITH ` " 2X6 P.T. (MIN. ATTACH TO BEAM W/ 1/2" DRYWALL
WITH ON IN O 3�//O� CX7w7A/// p2'O�WASHERS ❑R,
HOR SOLT AT
TOP CONTINUOUS 3N60o TAPCONIMENT' AT 12 OHOIM MI UM
SETT. R1N 6".EMBEDMENT
SEE PLAN
8" CMU WALL
CONVENTIONAL GABLE END CONNECTION DETAIL
NOT TO SCALE
YS tax TAP 2W ION
PER PLAN
N
w
! 1
4
1 Y
1 J
�
I i
1 1
1 N
1 t
1 1
P
e
T"-� Y4 FOOT PER P(ANIf
8°
6-41'
T-Q"
ENTRY DETAIL
NOT TO .SCALE
(2)2X12 HEADER OR AS
100.1.3 GROUT-
100.5.4-
ENTRY DOOR LIMITATIONS AND BUCK INSTALLATION
- NOTED ON THE PLANS
SHALL HAVE A MAXIMUM COARSE AGGREGATE SIZE OF 3/8
INCH PLACED AT AN 8 TO 11 INCH SLUMP AND HAVE A
ALL INTERIOR FRAME BEARING WALLS AND ALL EXTERIOR FRAME WALLS
SHALL BE ANCHORED TO THE ABUTTING CMU WALL WITH (3) 1/2"x6'
BUCKST S
yIOOO STRIPS BE 'ONE BY PRESSURE TREATED WOOD. MADtH SHALL BE SUFFICIENT
E
MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 2000 PSI
STANDARD WEDGE ANCHOR BOLTS EMBEDDED IN GROUTED CELLS.
TO EXTEND INTERIOR FACE OF THE WINDOW DOOR FRAME.
OFR
AT 28 DAYS WHEN TESTED IN ACCORDANCE WITH ASTM C
THE FLOOR P.T. PLATE SHALL BE ANCHORED WITH 1/2" x. 8" STANDARD
WEDGE ANCHORS AT 32'
THE WOOD BUCK STRIPS MAY BE INITIALLY ATTACHED THE CMU OR CONCRETE WITH CASFRARD
1-3/ E NAILS AT K D.C. THE BUCKS SHALL ATTACHED
T ATTACHED CMU OR REDHEAD WITH
1012, OR SHALL BE IN ACCORDANCE WITH ASTM C 476.
o.c.
TAPOONS (THROUGH THE DOOR FRAME) WITH SUFFICIENT LENGTH FOR A MINIMUM OF 1-1/4' OF
2 SIMPSON "LSTA21"
()
100.1.4 CONCRETE-
100.5.5-
PENETRATION INTO THE CMU OR CONCRETE. THE NUMBER OF TAPCONS SHALL BE PER THE
SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH
MANUFACTURER'S INSTALLATION DETAILS.
STRAPS PER SIDE PER
NOTE:
OF 30DO PS (2500 PS FOR SLABS) AT 28 DAYS PER ACI
AT ALL INTERIOR BEARING WALLS, WHENEVER AN UPLIFT CONNECTOR IS
DEADSOLT SHALL BE TITAN 780 SGL CYLINDER (OR EQUIVALENT) W/ 2-3/8' BACKSET 039' FROM
-
HEADER
BEARING W T.GO
318. SECTION 5.3. INSTALLATION OF CONCRETE SHALL BE
REQUIRED AT THE TOP OF THE WALL, THE CONNECTOR AT THE BOTTOM
TOP OF SLAB. LOCKSET SHALL BE TITAN. 720H SCL CYL (OR EQUIVALENT) W/ 2-3/8' BACKSET
PER ACI 318. SECTION 5.10.
SHALL HAVE CONSISTENT UPLIFT VALUE.
0 44-1/2- FROM TOP OF SLAB. USE 4-1/2- X 1-5/8- WOOD LOCK BLOCK 0 EACH LOCK PREP.
INTO BLOCK W) L -S ATTACH
100.1.5 REINFORCING STEEL-
100.5.6-
WITH WEDGE HORS 37 O.C.
SHALL BE MINIMUM GRADE 40 AND IDENTIFIED IN. ACCORDANCE -
WHENEVER A ORDER TRUSS BEARS ON A FRAME BEARING WALL, IT SHALL
GENERAL NOTE FOR OPENINGS;
VERTICALLY UF VIALL
MATH ASTM A 615. A 616, A 617, OR A 706.
BE SUPPORTED BY A MINIMUM OF AN EQUAL NUMBER OF STUDS AS PLIES
WOOD MEMBERS THICKER THAN THOSE SPECIFIED MAY BE USED. AS LONG AS THE LENGTH OF
1/2" 0 WEDGE ANCHORS, 8-
100.1.6 METAL ACCESSORIES-
IN THE GIRDER.
THE 3/16- TAPOONS IS SUFFICIENT TO OBTAIN A MIN. OF 1-31r PENETRATION INTO THE CMU
DEPTH WITHIN 6" OF STUDS; & 32" D.C.
JOINT REINFORCEMENT, ANCHORS, DAND WIRE FABRIC
100.5.7-
TRUSSES SHALL BE DESIGNED AND SEALED BY A PROFESSIONAL ENGINEER
OR TIE BEAM.ES,
HEADER NOTE
FOR REMAINING WALL
SHALL CONFORM TO THE FOLLOWING STANDARDS.
L ASTM A 82 FOIt JOINT REINFORCEMENT AND WIRE ANCHORS
REGISTERED N THE STATE OF FLORIDA AND SHALL CONFORM WtiH THE TPI
TYPICAL CORRECTION NOTES
(2)2
(2)2)C12 TO SANDWICH
W/3" HOOK AND 3" O
AND TIES.
FOR METAL PLATE CONNECTED TRUSSES, AND
PLYWOOD W/
(2) I/TROWS
WASHERS. NOTE: ALTERNATIVE
2. ASTM A 36 FOR PLATE, HEADED AND BENT BAR ANCHORS.
SHALL OBTAINSPECIFICATIONSOTTO
SHALL CONTAIN BOTTOM CHORD WIND BRACING METHODOLOGY.
1) ONE SIMPSON RtFBj4x10 MAY BE SUBSTITUTED FOR 1/2' ANCHOR BOLTS WHEN NECESSARY
(2) ROWS OF 3' NAILS
3. ASTM A 366 FOR SHEET METAL ANCHORS AND TIES.
2) MISSED HURRICANE STRAPS FOR CONCRETE BEAMS - USE SIMPSON MTSM20 PATH 7) 10d IN
6"O.C.
HOLDDOWN IS STEPSON "HTT4"
100.1.7 GALVANIZATION-
TRUSS AND (4) 1/4'x1-3/4" TTAN FASTENERS IN CONCRETE FOR UPUFTS UP M 670 LOS;
ATTACHED TO STUDS.
/
METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSIRUC-
101 FOOTINGS AND FOUNDATION
USE SIMPSON HTSM20 WITH (10) 10d NAILS IN TRUSS AND (4) 1/4"x1-3/4' TITAN FASTENERS
IN CONCRETE FOR UPLIFTS UP TO 1175 LBS;
-
TION AND NOT DIRCTLY EXPOSED TO THE WEATHER SHALL BE
101.1 DESIGN
3) MISSED DOWELS - SET 5/e' DIAMETER. 3r LENGTH DOWEL INTO 3/ex 8' HOLE SET IN
(1) SIMPSON "SPH4"
GALVANIZED IN ACCORDANCE WITH ASTM A 153. CLASS B-2
SIMPSON SET OR EQUIVALENT.
EPDXY
METAL ACCESSORIES FOR USE IN INTERIOR WALL CONSTRUCTION
101.1.1-
4) FIBERMESH FIBER REINFORCED CONCRETE MAY BE USED IN LIEU OF THE 6x6x10/10 WELDED
PER STUD. NOTE:.(2) -
SHALL BE MILL GALVANIZED IN ACCORDANCE WITH ASTM A 641,
TYPICAL FOUNDATION DETAILS AND MINIMUM SIZES ARE SHOWN ON THE
MARE MESH REINFORCEMENT IN CONCRETE FLOOR SLABS.
JACK STUDS & (1)
CLASS 1.
FOUNDATION PLAN AND THIS SHEET.
100.1.8 FASTENERS AND CONNECTORS-
101.1.2
KING STUD (MIN)
UNLESS OTHERWISE STATED, SIZES GIVEN FOR NAILS ARE
-A SOIL OR WASTE PIPE OR A BUILDING DRAM PASSING UNDER A FOOTING
ADDI110NAL GENERAL &STRUCTURAL NOTES
I III
I-
COMMON WIRE NAILS. FOR EXAMPLE, BD - 2 1/2 INCHES
OR THROUGH A FOUNDATION WALL SHALL DE PROVIDED WITH A RELIEVING
A
LONG 0.131-INCH DIAMETER. SEE TABLE &aA IN THE
ARCH, OR THERE SHALL BE BUILT INTO. THE MASONRY WALL AN IRON PIPE
T. CONSTRUCTION METHODS SHALL COMPLY WITH ALL STATE AND LOCAL CODES.
NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION.
SLEEVE TWO PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH.
2 GENERAL CONTRACTOR AND ALL SUB -CONTRACTORS M VERIFY DIMENSIONS,
- d e d -
IOO.I.$ WOOD FRAME MEMBERS
101.2 CONSTRUCTION
DETAILS. AND/OR ANY DISCREPENCIES PRIOR TO CONSTRUCTION.
v
d p -
d d' a'
ALL FRAMING LUMBER SHALL BE HEM -FIR, S. PINE,. OR
101.2.1-
3. THEE: PLANS WERE RENEWm BY THE ENGINEER FOR STRUCTURAL
COMPLIANCE WnH SECTION 1609 ONLY OF THE FLORIDA BUILDING CCDE.
CONCRETE FOUNDATION - d -.
d-
S-P-F. GRADE 2 OR BETTER WITH A MINIMUM Fb OF 1800 PS.
ALL LUMBER USED FOR BEAMS SHALL BE HEM -FIR, S. PINE- OR
THE OUTER BAR OF FOUNDATION STEEL SHALL BE CONTINUOUS AROUND
CORNERS USING CORNER BARS OR BY SENDING THE BAR IN ACCORDANCE
4. THE CONTRACTOR MAINTAINS THE RESPONSBIUIY FOR ALL CONSTRUCTION MEANS
d
_
C d - 4 - - ;AS NOTED ON PLANS �
- .
� o � d
S-P-F, GRADE 2 OR BETTER WITH A MINIMUM Fb OF 1700 PSI.
NATIi 100.3.4. IN BOTH CASKS, THE MINIMUM BAR LAP SHALL BE 25 INCHES.
METHODS & TECHNIQUES, INCLUDING BUT NOT UMITED TO THE STANDARD
CONNECTIONS OF ALL ROOF, WALL, FLOOR AND STRUCTURAL PANEL SYSTEMS
•
- A• d d -
-
- G
100.1.8 WOOD LVL BEAM MEMBERS
101.2.2-
5. UNLESS 07HERMSE NOTED, ANY OPENING GREATER THAN 6- IN A MASONRY WALL
-
p
-
d ., : ' d - e - C
c ..
ALL LVL BEAM LUMBER SHALL HAVE A MINIMUM FLEXURAL
FOUNDATION STEMWALLS SHALL BE AS THICK OR THICKER THAN THE WALL
SHALL HAVE THE CELLS ON EACH SIDE FILLED WITH CONCRETE AND (1) #5
VERTICAL RE
c d a,
d, - - d
STRFNTH. Fb, OF RISC PSI AND MODULUS OF ELASTICITY, E,
SUPPORTED ABOVE, BUT IN NO CASE LESS THAN 8 INCHES THICK, AND
-BAR.
OF ZOOO,000 PSI.
SMALL HAVE SAME VERTICAL REINFORCING AS THE WALL ABOVE.
6. UNLESS OTHERWISE NOTED. FOR WOOD BEARING OPENINGS UP TO 6' USE.
101_.3 FOOTING DOWELS
(2) 2x12 BEAM WITH (2) FULL LENGTH STUDS, AND FOR OPENINGS GREATER
_ -
THAN 6- USE (2) 202 BEAM AND (3) FULL LENGTH STUDS AT EACH END.
-
100.2 MASONRY WORK, GENERAL
ALL FOOTING DOWEL BARS SHALL HAVE A STANDARD 90 DEGREE HOOK AND
SHALL BE EMBEDDED A MINIMUM OF 6 INCHES INTO ALL FOOTINGS; DOWEL
CONNECT BEAMS TO STUDS WITH A MINIMUM OF (2) USP RT12's EACH END.
TO SUDS WITH A MINIMUM OF (2) USP R112's EACH END.
100.2.1-
BARS SHALL LAP VERTICAL WALL REINFORCEMENT A MINIMUM OF 25 INCHES.
7. Buildings shall be constructed in accordance with the provisions of
/� , A pR/�/'w�'►�
FRAME BRIG. WALL W, OPENING
ALL MORTAR JOINTS FOR HOLLOW UNIT MASONRY SHALL EXTEND
the climatic and geographic design criteria as limited by the
THE FULL WIDTH OF FACE SHELLS. MORTAR JOINTS FOR SOLID.
provisions of this section. Additional criteria in
TYPICAL CONNECTOR DETAIL
MASONRY SHALL BE FULL HEAD AND BED JOINTS.
to0.2.2-
1os OPEN STRUCTURES
Table R301.2(1) of the Florida Building Cod 2017 ban edition.
106.1-
8. Flame spread and make index for wall and ceiling flnia es shall
NOT TO.51 F
BED JOINTS SHALL BE 3/8 INCH (+ 1/b INCH) THICK. HEAD
JOINTS SHALL BE 3/8 INCH (+ 3/8 INCH OR -1/4 INCH) THICK.
COLUMNS SHALL BE CONSTRUCTED OF STANDARD MASONRY UNITS OR
PILASTER BLOCK OR MAY BE CAST N PLACE CONCRETE. MAXIMUM COLUMN
be in accordance with Sections R302.9.1 through R3029.4.
WIRE LATH
5/8"stucco (horizontal application) and
7/8" thick stucco (vertical application) on
3/8" hi rib lath attached to horizontal and
vertical wood f3{aming with nails or staples
to provide no 1 s than 1-3/4" penetration
into horizontalood framing and 3/4"
penetration into vertical wood framing
members
PRE-MANUFACTURI
TRUSSES
2X4 STUDS
SEE WALL SE,
FOR APPLICA
AND STUD SF
@ 24" O.C.
2X BLOCKING
AS REQUIRED
BY FLORIDA
BUILDING COL
RESIDENTIAL
100.2.3-
HEIGHT SHALL BE 12 FEET TO TOP OF BOND BEAM. COLUMNS SHALL 9.
Flame spread and smoke -developed 'index for insulation shall be
THE BED JOINT OF THE STARTING COURSE PLACED OVER FOOTINGS
CONTAIN A MINIMUM OF FOUR VERTICAL BARS, ONE IN EACH CORNER.
in accordance with Sections R302.10.1 through R30210.5.
SHALL PERMITTED TO VARY IN THICKNESS FROM A MINIMUMto
1. VERTICAL COLUMN REINFORCEMENT SHALL BE FOUR NO. 3 BARS FOR 10.
AN gypsum boats materials and accessories shall
I
O' 1/4 NCH TO A MAXIMUM OF 3/41NCH.
6xCH 81NCOLUMNS AND FOUR NO. 5 BARS FOR ALL OTHER .COLUMN SIZES
ASTM C 22. C 475,C514, C 10024 C 1047, C 1177, 7, C C 11 t178.8, C
100.2.4-
2 CLEARANCE FROM THE VERITCAL BAR TO THE MASONRY FACESHELL SHALL
BE 1/2 INCH. MINIMUM COVER FOR IN PLACE COLUMNS
1278, C 1396 or C 1658 and shall be installed in accordance with
CAST SHALL
the provisions of this section. Adhesives for the installation of
MASONRY WALLS SHALL BE RUNNING BOND OR STACK BOND
BE 1-1/2 INCHES OVER THE COLUMN TIES.
gypsum board shall conform to ASTM C 557.
_ CONSTRUCTION. WHEN MASONRY UNITS ARE LAID IN STACK BOND,
106.2-
9-GAGE (MINIMUM) HORIZONTAL JOINT REINFORCEMENT, IN
CONNECTION OF COLUMNS TO THE FOUNDATION BELOW AND TO THE BOND 11.
Ceramic file surfaces shall be installed in accordance with ANSI
- ADDITION TO REQUIRED VERTICAL REINFORCEMENT, SHALL BE
BEAM AT THE TOP SHALL BE AS FOLLOWS:
A10&1, A108.4, A108.5,.3, . AT08.6, A108.11, A118.1, AII8A136.1
PLACED IN BED JOINTS AT NOT MORE THAN 16 INCHES ON CENTER. -
1. Bx6 INCH COLUMN; ONE N0. 5 STANDARD 90 HOOK INTO THE SUPPORT
and. A137.1.
100.2.5-
AT THE BOTTOM AND INTO THE BOND BEAM AT THE TOP.
LONGITUDINAL WIRES OF JOINT REINFORCEMENT SHALL BE FULLY
2 Sxi6 INCH COLUMN; TWO NO. 5 STANDARD 90 HOOKS (ONE IN EACH
EMBEDDED IN MORTAR OR GROUT WITH A MINIMUM COVER OF 5/8
CELL) BOTH AT THE BOTTOM AND INTO THE BOND BEAM AT THE TOP.
INCH WHEN EXPOSED TO EARTH OR WEATHER AND 1/2 INCH WHEN
3. 12x12 INCH COLUMN AND 1646 INCH COLUMN; FOUR NO. 5 STANDARD
NOT EXPOSED TO EARTH OR WEATHER.
90 HOOKS (ONE AT EACH VERTICAL BAR) EXTENDING FROM THE FOUNDATION
AND SPLICED WITH THE VERTICAL COLUMN REINFORCEMENT FOR THE BOTTOM;
100.3 REINFORCING STEEL GENERAL
THREE No. 5 STANDARD 90 HOOKS INTO THE BOND BEAM AT TOP, MINIMUM,
100.3.1-
AND EACH SPACED INTO A VERTICAL COLUMN BAR FOR CORNER COLUMNS; &
REINFORCING STEEL SHALL BE N0. 5 BARS. EXCEPTION: WHERE
TWO N0. 5 STANDARD 90 HOOKS INTO THE BOND BEAM AT THE TOP EACH
TEA) NO. 5 BARS ARE REQUIRED WITHIN THE SAME GROUTED
SPLICED TO SPARATE VERTICAL COLUMN BARS FOR COLUMNS NOT LOCATED
IN A CORNER.
MASONRY CELL OR BOND BEAM, ONE NO. 7 BAR MAY BE
106.3-
SUBSTITUTED.
100.3.2-
LATERAL TIES OF A MINIMUM 1/4 INCH DIAMETER SHALL BE USED TO ENCLOSE
T
VERTICAL COLUMN REINFORCEMENT AS FOLLOWS:
N
WHEN TWO BARS ARE REQUIRED IN THE SAME CELL OR BOND BEAM,
I. MAXIMUM VERTICAL SPACING OF LATERAL TIES .SHALL NOT EXCEED THE LEAST
REV1
THEY MAY BE BUNDLED.
NOMINAL CROSS SECTIONAL DIMENSION OF THE COLUMN.
100.3.3-
2LATERAL TIES MAY BE PLACED N THE MORTAR JOINTS (PROVIDED THEY ARE NO
LARGER THAN 1/4 INCH DIAMETER) OR IN THE GROUT. -
SPLICES SHALL BE LAP SPLICES.
3. THE BOTTOM LATERAL TIES SHALL BE LOCATED VERTICALLY NOT MORE THAN ONE
1. NONCONTACT LAP SPLICES MAY BE USED PROVIDED REINFORCING
- -HALF THE LATERAL TIE SPACING ABOVE THE TOP OF THE FOOTING, SLAB, OR
BARS ARE NOT SPACED FARTHER APART THAN 5 INCHES FOR NO. 5
BEAM IN ANY STORY. THE TOP LATERAL TIE SHALL NOT BE MORE THAN ONE
BARS AND 7.INCHES FOR NO. 7 BARS.
-HALF THE LATERAL TIE SPACING BELOW THE LOWEST HORIZONTAL REINFORCEMENT
2. SPLICE LENGTHS SHALL BE A MINIMUM OF 25 INCHES FOR NO. 5
IN THE BEAM ABOVE.
BARS AND 35 INCHES FOR NO. 7 BARS (40 BAR DIAMETERS). SPLICES
OF A NO. 5 BAR WITH ONE NO. 7 BAR SHALL BE A MINIMUM OF 25
107 WINDOWS
MINIMS, AND TWO N0. 5 BARS WITH ONE N0. 7 BAR SHALL BE A
MINIMUM OF 35 INCHES.ALL
EXTERIOR GLAZING MATERIALS SHALL BE IMPACT RESISTANT COVERINGS CERTIFIED
100.3.4-
BY THE MANUFACTURER TO MEET THE REQUIREMENTS OF SST ASTM E 1886 AND
Q,
ASTME 1996. HOWEVER, IF PANELS MEETING THE LOADING REQUIREMENTS OFFBC
ME
REINFORCEMENT MAY BE BENT IN THE SHOP OR IN THE FIELD IF:
1609.1 FOR THE 170 MPH WIND BORNE MISSILE TEST, OR, WOOD STRUCTURAL PANELS
1. ALL REINFORCEMENT IS BENT COLD, AND
MEETING THE REQUIREMENTS OF FBC 1609.1.2 ARE USED FOR OPENING PROTECTION
2. THE DIAMETER OF THE BEND, MEASURED ON THE INSIDE OF THE
THEN THE WINDOWS NEED ONLY MEET THE PRESSURE REQUIREMENTS OF FBC 1609.1
BAR, IS NOT LESS THAN SIX BAR DIAMETERS, AND
FOR THE 170 MPH HAND LOAD AND NOT THE WIND BORNE MISSILE TEST. THE CON-
3. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT
TRACTOR IS REQUIRED TO PROVIDE DOCUMENTATION FOR THE WINDOWS AND PANELS
�1L� p
WERE
BE FIELD BENT. EXCEPTION: ERE BENDING IS NECESSARY TO
DEMONSTRATING COMPLIANCE WITH THESE SPECIFICATIONS.
REVIEWED FOR..
ALIGN DOWEL BARS WIN A VERTICAL CELL, BARS PARTIALLY
lO8 DOORS
EMBEDDED IN CONCRETE SHALL BE PERMITTED TO BE BENT AT A
CODE COMPLIANCE
- SLOPE OF NOT MORE THAN 1 INCH OF HORIZONTAL DISPLACEMENT
TO 6 INCHES OF VERTICAL BAR LENGTH.
ALL EXTERIOR DOOR MATERIALS SHALL BE ABLE TO RESIST THE LOADING REQUIREMENTS
SECTION170 MPHIs
COUNTY
REA
ST. LUCiE.
Qp�M PRIDEDOCUMENTATIONFORDOORS DEMONSTRATING COMPUNE
-
WITH THESE SPECIFICATIONS.
sOCC
100.4 COVER OVER REINFORCING STEEL
WINDOW, EXTERIOR DOOR AND PANEL CRITERIA
100'4'1-
THE MANUFACTURERS SPECIFICATIONS AND TEST RESULTS FOR THE REFERENCED WINDOWS,
FOR FOUNDATIONS MINIMUM CONCRETE COVER OVER REINFORCING
SGD, DOORS AND PANELS IN REGARDS TO COMPLIANCE VAN FLORIDA BUILDING CODE
BARS SHALL BE 3 INCHES IN FOUNDATIONS WHERE CONCRETE
SECTION 15M FOR A 160 MPH, 3 SECOND GUST, WIND LOAD HAVE BEEN RENEWED AND
IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE
ACCEPTED BY THE ENGINEER OF RECORD FOR USE ON INS PROJECT WHEN INSTALLED
EARTH; OR, 1-1/2 INCHES FOR No. 5 AND SMALLER BARS, AND
IN ACCORDANCE WITH THESE PLANS AND THE MANUFACTURER'S SPECIFICATIONS
2 INCHES FOR No. 6 AND LARGER BARS WHERE CONCRETE IS
FORMED AND WILL BE EXPOSED TO THE WEATHER. IN NARROW
FOOTINGS WHERE. INSUFFICIENT WIDTH IS AVAILABLE TO ACCOMODATE
A STANDARD 90 DEGREE HOOK AND PROVIDE THE REQUIRED CON-
CRETE COVER, THE HOOK SHALL BE ROTATED IN THE HORIZONTAL
-
DIRECTION UNTIL THE REWIRED CONCRETE COVER IS ACHIEVED..
100.4.2-
FILE COPY
FOR CAST -IN -PLACE BOND BEAMS WHERE CONCRETE IS
NOT EXPOSED TO WEATHER, THE MINIMUM CONCRETE COVER
FOR REINFORCING SHALL BE 1 1/2 INCHES REGARDLESS
OF BAR SIZE.
DETAILS
AND
D
100.4.3-
,
FOR CAST -IN -PLACE BOND BEAMS WHERE CONCRETE IS EX-
� C
C ^ n
POND TO WEATHER, THE MINIMUM CONCRETE COVER FOR
I
SPECIFICATIONS
C
'
`V �� ' O
REINFORCING SHALL BE
V\
it J
1 1/2 INCHES FOR N0. 5 BARS AND SMALLER,
2 INCHES FOR NO. 6 BARS AND LARGER. +
100.4.4-
REINFORCDMENTBARS EMBEDDED IN GROUTED MASONRY CELLS' '
SHALL HAVE A MINIMUM CLEAR DISTANCE OF 1/4 INCH FOR
FINE GROUT OR 1/2 INCH FOR COARSE GROUT BETWEEN
REINFORCING BARS AND ANY FACE OF A CELL I
100.4.5-
REINFORCING BARS USED IN MASONRY WALLS SHALL HAVE A -
MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN: - w F;z b F,, - L A N
2 INCHES FOR MASONRY UNITS WITH FACE EXPOSED TO
EARTH OR WEATHER:
1 1/2 INCH FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. 5109 Grand Palmetto Way ChdsbeerS@byu.net 941-628-0635
_ .k_..a�..,_._. s, ......... .... ... .... ..... �.....
NOTE: NON BEARING WALL DETAIL IS IN
ACCORDANCE WITH 011i OF THE
qNECTION FLORIDA BUILDING CODE STH EDITION
NOT TO SCALE
- it124. -
4��prESS{,�4,�F';•; _j�'°fib
•ko-
: e caipotb � h
Digitally signed 6y Christopher D Beers
Christopher DIN: r-US, o=IdenTrust ACES Unaffiliate
individual, cn=Christopher D Beers,
0.9.2342.19200300.100.1.1=AO 1098
D 00163D5C5O5EC00009BOA
Beers Date: 2020.03.24 08:32:07 -O VOV
CHRISTOPHER D. BEERS, P.E.
FLORIDA LICENSE NO. 64594
Although every effort is made to
ensure the accuracy of these
plans it is the responsibility of
the builder to verify all
dimensions, details and
specifications shown.
Bluestream Design Studio will
not be held liable for any errors
or omissions on these plans.
."4w -
BLUESTREAM
DS DESIGN
STUDIO
Residental CAD Drafting
3D Renderings
Graphic Design Services
Port Orange, FI
(386)256-8978
Port Charlotte, Fl
(941) 275-9931
www.bluesteamdesigrisLudio.com
CAD@bluestreamdesignstudio.com
LU
a
J M
Z u-
Q W
� C
2Cod
to E-
Lrl
Z
C
lift
m
Design and layout or concepts
for this design were provided to
Bluestream Design Studio by
the builder shown. Any
similarities to other plans or
blueprints is solely the
responsibility of the builder.
Plans may not be reproduced or
copied without the express
written consent of the Builder
shown.
DATE
3/13120
DESIGN BY:
LBS
CHECKED BY:
TMS
JOB NO.
VERMONTSO Pe
REV
DESCRIPTION
I
PT OM19
2
P2IWO2119
3
P310/25/19
4
P411/06/19
5
P5 02/28/2020
6
P6 03111/2020
7
8
-j i
U)
F- z W'
Z :3 U
O 00
W w Ch Uj
W � a
0Uj
L.L N c
SHEET
S2
STRUCTURAL
SCALE: 1/4" = V-O"
10OF8
nit set
N