HomeMy WebLinkAboutEvaluation ReportDIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 0616 00—SHEATHING DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 25 00—WATER-RESISTIVE BARRIERS/WEATHER BARRIERS A SECTION: 07 27 00—AIR BARRIERS 3i OF o �b�r%�PJw REPORT HOLDER: HUBER ENGINEERED WOODS, LLC EVALUATION SUBJECT: ZIP SYSTEM° WALL SHEATHING ICC ICC ICC - 3"*) � M (P "� C"'") FILE COPY "2014 Recipient of Prestigious Western States Seismic Policy Council t�� (WSSPQ Award in Excellence" A Subsidiary of 000E OUNCIC ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. , �°"EEC 1705a , 01M Copyright ® 2018 ICC Evaluation Service, LLC. All rights reserved. ESR-1474 I Most Widely Accepted and Trusted Page 3 of 9 SILL SECTION HEADER SECTION JAMB SECTION FIGURE 1—TYPICAL CROSS SECTIONS OF FLANGED WINDOW ESR-1474 I Most Widely Accepted and Trusted Page 4 of 9 SILL SECTION HEADER SECTION WINDOW JAMB ZE SYSTEM' WALL SHEATHING ADHE9VE-BADKEO FLASHING TAPE OUTSIDE CAULKING ROUGH OPENING INSIDE LOW-PRESSURE POLYURETHANE FOAM JAMB SECTION FIGURE 2—TYPICAL CROSS SECTIONS OF INSTALLED BRICK MOLD WINDOW ESR-1474 I Most Widely Accepted and Trusted Page 5 of 9 ZIP SYSTEM TM WALL SHEATHING WALL FRAMING ADHESIVE -BACKED FLASHING TAPE FLASHING FASTENER ADHESIVE -BACKED FLASHING TAPE �ROOF UNDERLAYMENT (FEM � ROOF SHEATHING ROOF JOIST FIGURE 3-ROOF-WALL INTERSECTION (OPTION 1) FIGURE S-TYPICAL WALL -SILL INTERSECTION AND FLASHING DETAILS FOR BRICK SIDING ZIP SYSTEMT%l WALL SHEATHING WALLFRAMING ADHESIVE -BACKED FLASHING TAPE FLASHING FASTENER COUNTER FLASHING BASE FLASHING ,- FLASHING FASTENER ilVEAACKED FLASHING TAPE ROOF UNDERLAYMENT (FELT) - ROOF SHEATHING ROOF JOIST FIGURE 4-ROOF-WALL INTERSECTION (OPTION 2) FIGURE 6-TYPICAL WALL -SILL INTERSECTION AND FLASHING DETAILS FOR LAPPED SIDING IMES Evaluation Report ESR-1474 LABC and LARC Supplement Reissued October 2018 This report is subject to renewal October 2020. www.icc-es.orq 1 (800) 423-6587 1 (662) 699-0543 A Subsidiary of the Intemational Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 06 16 00--Sheathing • DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 25 00—Water-resistive Barriers/Weather Barriers Section: 07 27 00—Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the ZIP System Wall Sheathing, described in [CC -ES master evaluation report ESR-1474 has also been evaluated for compliance with the codes noted below as adopted by the Los Angeles Department of Building and Safety (LADBS). Applicable code editions: ■ 2017 City of Los Angeles Building Code (LABC) ■ 2017 City of Los Angeles Residential Code (LARC) 2.0 CONCLUSIONS The ZIP System® Wall Sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474 complies with the LABC Chapter 14, and the LARC Section R703, and is subject to the conditions of use described in this supplement 3.0 CONDITIONS 00 USE The ZIP System® Wall Sheathing, described in this evaluation report must comply with all of the following conditions: ■ All applicable sections in the master evaluation report ESR-1474. ■ The design, installation, conditions of use and identification are in accordance with the 2015 International Building Code (2015 IBC) provisions noted in the master evaluation report ESR-1474. ■ The design, installation and inspection are in accordance with additional requirements of LABC Chapters 16 and 17, as applicable. This supplement expires concurrently with the master report, reissued October 2018. !CC -ES Evaluation Repons are not to be rnmwedas mpreeemmgoetihetis army otberaltnbutes no, spechmlly ddres.d. norare they to be conshued as on endo,.,., of the subject of the report or a recommendation fur its use.. There is no x.arrenly by lCL' Evalumiun Service, LLC, express or implied. in m to myfinding or other matter in this report, or as to airy product covered by the repon. Copyright 0 2018 ICC Evaluation Service, LLC. All rights reserved. Page 7 of 9 ICC-ES Evaluation Report ESR-1474 CBC and CRC Supplement Reissued October2018 This report is subject to renewal October 2020. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 25 00—Water-resistive Barriers/Weather Barriers Section: 07 27 00—AIr Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System® Wall Sheathing, recognized in ]CC -ES master evaluation report ESR-1474, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2016 California Building Code (CBC) ■ 2016 California Residential Code (CRC) 2.0 CONCLUSIONS 2.1 CBC The ZIP System Wall Sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, complies with CBC Chapter 14, provided the design and installation are in accordance with the 2015 International Building Code® (2015 IBC) provisions noted in the master report and the additional requirements of the CBC Chapters 14, 16, 16A, 17, 17A and 23, as applicable. 2.2 CRC The ZIP System Wall Sheathing, as described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474e complies with the CRC, provided the design and installation are in accordance with the 2015 International Residential Code (2015 IRC) provisions noted in the master report. The ZIP System® Wall Sheathing recognized in this supplement has, not been evaluated for compliance with the International Wildland-Urban Interface Code . This supplement expires concurrently with the master report, reissued October 2018. ICC-ES Evaluation Reports are not to be ronatrued as repraenaag aesrhedas or any other attributes notspec fmRyaddressed, nor are they to be construed as an endorsement of the suh)em of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, esprrrs ar imphed as :'� to arty finding or other matter in this report. or ae to airy product covered by the report Copyright 0 2018 ICC Evaluation Service, LLC. All rights reserved. Page B of 9 [CC -ES Evaluation Report ESR-1474 FBC Supplement Reissued October 2018 This report is subject to renewal October 2020. www.icc-es.ora 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the Intemational Code Council® DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 25 00—Water-Resistive Barriers/Weather Barriers Section: 07 27 00—Air Barriers REPORT HOLDER: HUBER ENGINEERED WOODS, LLC EVALUATION SUBJECT: ZIP SYSTEM® WALL SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP Systems Wall Sheathing panels, recognized in [CC -ES master evaluation report ESR-1474, have also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2017 Florida Building Code —Building ■ 2017 Florida Building Code —Residential 2.0 CONCLUSIONS The ZIP System Wall Sheathing panels, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1474, comply with the Florida Building Code —Building and the Florida Building Code —Residential, provided the design and installation are in accordance with the 2015 International Building Code provisions noted in the master report. Use of the ZIP System® Wall Sheathing panels for compliance with the High -Velocity Hurricane Zone provisions of the Florida Building Code —Building and the Florida Building Code —Residential has not been evaluated, and is outside the scope of this evaluation report. For products falling under Florida Rule 9N-3, verification that the report holder's quality assurance program is audited by a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued October 2018 ICC-ES Evaluation Reports are not to be construed as representing aesthetics orarry other ardibves not spec fcaQy addressed. nnrare they to he construed as an endorsement ufthe suhjectof the report arts recommendation fur its use. There is no varrenry by WC Evalualmn Servrce. LLC, express or implied, at to any finding or other matter in this report, or as to anvproduct covered by the report Copyright C 2018 ICC Evaluation Service, LLC. All tights reserved. Page 9 of 9