Loading...
HomeMy WebLinkAboutbuilding permitAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: (l. -- s" COUNTY F L O R I D A" Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Permit Number: Building Permit Application Commercial Residential j PERMIT TYPE: Z�7eG�rG PROPOSED IMPROVEMENT LOCATION: Address: 5-iYO 7 (jve- Property Tax ID #: 3"105-/ - 5-0l -65-5-3 010 % Lot No. Site Plan Name: Project Name: DETAILED DESCRIPTION OF WORK: Block No. - ,5S'-'/ / i kh/ Sta laj (jtlte(�7u� i.✓r f� Cii iy.Y��uf � t rYi�S t P 5wi{c;l� 11n feJ O,, ( of cr-dt- CONSTRUCTION INFORMATION: Additional work to be performed under this permit - check all that apply: _Mechanical _ Gas Tank _ Gas Piping A/ Electric _ Plumbing _ Sprinklers Total Sq. Ft of Construction: Cost of Construction: $ Shutters Generator Sq. Ft. of First Floor: Utilities: —Sewer _Septic Windows/Doors Roof Pitch Building Height: OWNER/LESSEE: CONTRACTOR: Name %eon�Ah Oa v Name: l)eml' el 5+yb6S Address: S 1-tv Company: Sfw l�ci�r City: P' e; (f' State: F Zip Code: 3f-142Y'�- Fax: Phone No. Address: 5-c91 City: P, e-Ce, State:/ / Zip Code: Fax: Phone No 72)-- - ` PI-1411.46 E-Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail t'lbb5 33 d &{7u,: I • ` k-n State or County License '300 7 / If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DE5)GNER/ENGINEER: _Not Applicable MORTGAGE COMPANY: — Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEES LE TITLE HOLDER: _ Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: _ Zip: Phone: Zip: Phone: OWNER( CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie Courty Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." i Signature of O�.v er(' LesseeiContractor as agent for O% ner Signature of Con ractor/bcense Holder STATE OF FLORIDA, I STATE OF FLORIDA COUNTY OF 1 - ,0 A c- COUNTY OF The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me :his day of 20'Z(- by this cay of 20_ by Name of person making statemen-. tame of person. making statement. Personally Known. � OR Produced Identification Personally Known OR Produced Identification Type of Identification Type of Identification Produced Produced . igna:ure of Notary Public- State o Ftf9iia L of Public- State of Florida ; LAURAR.CUBBEDGE Commission No. Commission# GG 022075rn s, n No. (Seal) Expires October 21, 2020 of WoM TtW TIDY Fain L um= 8M385-7019 — REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE 'MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW SATE-- ---- — ---- -------------- ------- RECEIVED DATE COMPLETED Y S C ' d J TLC 11 10/13/16 kW INCLUDES: • True Power" Electrical Technology • Two-line multilingual digital LCD Evolution'" controller (English/Spanish/French/Portuguese) • Two transfer switch options available: 100 amp 16 circuit switch or 200 amp service rated smart switch • Electronic governor • Standard VVi-Fi' connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled by the Southwest Research Institute allowing installation as close as 18 in (457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. https. Ilassets. swri. orgllibraryIDirectotyOfListedProductsl Constructionlndustry1973_ DoC_204_ 13204-01-01 _Rev9. pdf FEATURES iirNuuA-HVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA M61-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY O MOBILE LINK"` WI-FI CONNECTIVITY: FREE with select Guardian Series home standby generators, Mobile Link Wi-Fi allows users to monitor the status of the generator from anywhere in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. GENERAL' GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007171-0, G007172-0 (Aluminum - Bisque) —10 kVV 60 Hz G007173-0, G007174-0, G007175-0 (Aluminum - Bisque) —13 kVV 60 Hz G007176-0, G007177-0, G007178-0 (Aluminum - Bisque) —16 kW 60 Hz V GENERAC c\\ 1 I/us or CL LISTED OS Note: CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. GENERAC PROMISE iM C�L7 10/13/16 kW Features and Benefits Engine • Generac G-force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance. and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers vital electrical loads to the energized source of power. • NEMA 311 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near an existing distribution panel for simple, low-cost installation. Evolution`" Controls • AUTO/MANUAL/OFF illuminated buttons • Two-line multilingual LCD • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Programmable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Select the operating mode and provide easy, at -a -glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Smooth, weather -resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to verify the cleanest power is delivered to the home. Prevents nuisance startups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Verifies engine is ready to assume the load. Setpoint approximately 5 seconds. Allows engine to cool prior to shutdown. Setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Offers a selectable setting for weekly or monthly operation, providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. 10/13/16 kW Generatoi GENERAC Specifications Model G007171-0, G007172-0 0007173-0, G007174-0, G007176-0, G007177-0, (10 kW) 0007175-0 (13 kW) G007178.0 (16 kW) Rated maximum continuous power capacity (LP) 10,000 Wafts* 13,000 Watts* 16,000 Watts* Rated maximum continuous power capacity (NG) 9,000 Watts* 13,000 Watts* 16,000 Watts* Rated voltage 240 Rated maximum continuous load current - 240 volts (LP/NG) 41.7 / 37.5 54.2 / 54.2 66.7 / 66.7 Total Harmonic Distortion Less than 5% Main line circuit breaker 45 Amp 60 Amp 70 Amp Phase 1 Number of rotor poles 2 Rated AC frequency 60 Hz Power factor 1.0 Battery requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit weight (Ib/kg) 338/153 385/175 420/191 Dimensions (LxWxH)in/cm 48 x 25 x 29 / 121 .9 x 63.5 x 73.7 Sound output in dB(A) at 23 It (7 m) with generator operating at normal load** 61 65 65 Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test'" low -speed exercise mode** 57 55 55 Exercise duration 5 min Engine Engine type GENERAC G-Force 400 Series GENERAC G-force 800 Series Number of cylinders 1 2 Displacement 460 cc 816 cc Cylinder block Aluminum w/ cast iron sleeve Valve arrangement Overhead valve Lifter type Solid Hydraulic Ignition system Solid-state w! magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx. 1.1 qt! 1.0 L Approx. 2.2 qt / 2.1 L Operating rpm 3,600 Fuel consumption Natural Gas ft3/hr (m3/hr) 1/2 Load 101 (2.86) 154 (4.36) 182 (5.15) Full Load 127 (3.60) 225 (6.37) 245 (6.94) Liquid Propane ft3/hr (gal/hr) [L/hr] 1/2 Load 36 (0.97) [3.66] 56 (1.54) [5.83] 62 (1.70) [6.45] Full Load 54 (1.48) [5.62] 90 (2.45) [9.28] 109 (2.99) [11.321 Ncte: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7.0 in water column (0.87-1.74 kPa) for NG, 10-12 in water column (2.49-2.99 kPa) for LP c_as =or STU coiicn[. m itiply ft'/hr x 2,500 (LP) or ft3/hr x 1,000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG). Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons: AUTO Automatic start on utility failure. Weekly, Bi-Weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place. OFF Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility voltage loss/Retum to utility adjustable (brownout setting) From 140-171 V / 190-216 V Future set capable exerciser/Exercise set error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration). Starter lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC Warning Standard Low Baftery/Bahery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard **Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). * Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU (Megajoule) content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5%for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1 % for each 6 *C (10 *0 above 16 °C (60 `F). 10/13/16 kW Limited Circuits Switch Features • 16 space, 24 circuit. Breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking, • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1 in standard, tandem, GFCI, and AFCI breakers from Siemens, Murray, Eaton, and Square D for the most flexible and cost effective install. Dimensions Height Width Depth H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 cm 67.94 76.43 26.67 34.18 17.54 Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0-#14 2/0-#14 1 2/0-#14 Model GENERAC' Switch Options G007172-0 (10 kW) No. of poles Current rating (amps) Voltage rating (VAC) Utility voltage monitor (fixed)* -Pick-up -Dropout Return to utility* Exercises bi-weekly for 5 minutes* ETL or UL Listed Total circuits available Tandem breaker capabilities Circuit breaker protected Available RMS Symmetrical Fault Current @ 250 Volts *Function of Evolution controller Exercise can be set to weekly or monthly i- DEPTH - Sr:fvice Rated Smart Switch Features Model • Includes Smart A/C Management (SACM) module standard. • Intelligently manages up to four air conditioner loads with no additional No. of poles hardware. Current rating (amps) • Up to eight large (240 VAC) loads can be managed with Smart Management Voltage rating (VAC) Modules (SMMs). Utility voltage monitor (fixed)* • Electrically operated, mechanically -held contacts for fast, clean connections. -Pick-up • Rated for all classes of load,100% equipment rated, both inductive and -Dropout resistive. Return to utility* • 2-pole, 250 VAC contactors. Exercises bi-weekly for 5 minutes* • Service equipment rated, dual coil design. ETL or UL Listed • Rated for both aluminum and copper conductors. Enclosure type • Main contacts are silver plated or silver alloy to resist welding and sticking. Circuit breaker protected • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Lug range mounting flexibility. * Dimensions 200 Amps 120/240, to Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.3 GM 67.94 76.45 26.67 1 34.3 16.01 Wire Ranges Conductor Lug Neutral Lug Ground Lug 400 MCM - #4 350 MCM - #6 2/0 - #14 G007174-0 G007177-0 (13 kW) (16 kW) 2 100 120 / 240,10 80% 65% Approx. 15 sec Standard Standard 24 8 tandems 10,000 G007175-0 G007178-0 (13 kw) (16 kW) Function of Evolution Controller Exercise can be set to weekly or monthly L DEPTH J 2 200 120/240,10 80% 65% 15 sec Standard Standard NEMA/UL 311 22,000 250 MCM - #6 GENERAC' 10/13/16 kW Available Accessories Model # Product Description G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact ). G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). (Not necessary for use with AGM -style batteries). G007102 0 Oil Warmer Oil warmer slips directly over the oil fitter. Recommended for use if the temperature regularly falls below 0 °F (-18 °C). G007103-1 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you Contact Kit may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, G007027-0 - Bisque Fascia Base Wrap Kit contoured appearance as well as offering protection from rodents and insects by covering the lifting holes lo- cated in the base. G005703-0 - Bisque Touch -Up Paint Kit If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. G006482-0 —10 kW Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the items necessary to perform complete routine maintenance G007216-0 —13 / 16 kW on a Generac automatic standby generator (oil not included). The Wi-R enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring G007005-0 Wi-Fi LP Fuel Level Monitor the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0 (50 amps) Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages G007006-0 (100 amps) Smart Management Module large electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce the overall size and cost of the system. The Mobile Link 46 LTE Cellular Accessory allows users to monitor the status of the generator from anywhere G007169-0 Mobile Link" 413 LTE Cellular in the world, using a smartphone, tablet, or PC. Easily access information such as the current operating status Accessory and maintenance alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. Model UPC G007171-0 696471074680 G007172-0 696471074673 G007173-0 696471076400 0007174-0 696471077100 G007175-0 696471077117 G007176-0 696471076417 G007177-0 696471077124 G007178-0 696471077131 GENERAC` 125.5 in] LEFT SIDE VIEW Dimensions & PCs t48.5 fnf FRONT VIEW Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000033190 Rev. A 07/26/19 10/13/16 kW Installation System • 14 in (35.6 cm) flexible fuel line connector • Integral sediment trap Connectivity • Ability to view generator status • Ability to view generator Exercise/Run and Total Hours • Ability to view generator maintenance information • Monthly report with previous month's activity • Ability to view generator battery information • Weather information GENERAC' Features and Benefits Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. Meets IFGC and NFPA 54 installation requirements. Monitor your generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. Review the generator's complete protection profile for exercise hours and total hours. Provides maintenance information for your specific model generator when scheduled maintenance is due. Detailed monthly reports provide historical generator information. Built in battery diagnostics displaying current state of the battery. Provides detailed local ambient weather conditions for generator location.