Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENGINEERING
DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 PV-3 PV-4 SITE PLAN SINGLE-LINE DIAGRAM SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 FIRE SAFETY PLAN ELECTRICAL CALCULATIONS MODULE DATASHEET ARRAY WIRING BOX DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY ADDRESS ZONING USE AND OCCUPANCY CLASSIFICATION UTILITY COMPANY ELECTRICAL CODE FIRE CODE OTHER BUILDING CODES 5601 CASSIA DR FORT PIERCE, FL 34982 RESIDENTIAL ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) FPL 2014 NEC (NFPA 70) 2015 NFPA 1 2017 FL BUILDING CODE RESIDENTIAL 6TH EDITION COMPANY ADDRESS CONTRACTOR INFORMATION EFFICIENT HOME SERVICES 9416 INTERNATIONAL CT, ST PETERBURG, FL 32907 PHONE NUMBER (844) 778-8810 PROJECT DATE: 6/1/20 PV-1 AP P E N D I X GR I D - T I E D S O L A R P O W E R S Y S T E M REYES MANUEL RUIZ-DONATE 88991PE 56 0 1 C A S S I A D R FO R T P I E R C E , F L 3 4 9 8 2 P-132296 This item has been signed and sealed byReyes Manuel Ruiz Donate, 88991PE on 6/1/2020using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. GENERAL NOTES P-132296 1 2 3 4 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. (N) AC COMBINER (C1), OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE SITE PLAN PV-2 1 2 EFFICIENT HOME SERVICES 844-778-8810 EHSFL.COM REYES MANUEL RUIZ-DONATE 88991PE 9416 INTERNATIONAL CT ST PETERSBURG FL 32907 GR I D - T I E D S O L A R P O W E R S Y S T E M REYES MANUEL RUIZ-DONATE STREET CASSIA DR 5 UTILITY METER ACCESSIBLE 24/7 Layout subject to modification due to roof obstructions without interference of the safety fire pathways. MANUAL DISCONNECT LESS THAN 10 FT FROM UTILITY METER 3 4 (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 27 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 156° AZIMUTH S T R E E T C A S S I A D R 3 4 5 2 DATE: 6/1/20 56 0 1 C A S S I A D R FO R T P I E R C E , F L 3 4 9 8 2 5 4 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF NEC ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO 690.47(B) AND 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO 250.166 AN ADDITIONAL ARRAY GROUNDING ELECTRODE SHALL BE INSTALLED IN ACCORDANCE WITH NEC SECTIONS 250.52 AND 250.54 UNLESS THE ARRAY STRUCTURE IS SUITABLE TO SERVE AS A GROUNDING ELECTRODE AS PER NEC SECTION 250.2, THE LOAD SERVED BY THE ARRAY IS INTEGRAL WITH THE ARRAY, OR THE PREMISE'S EXISTING WIRING ELECTRODE IS LOCATED WITHIN 6FT, AS PER NEC SECTION 690.47(D) 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 43.1V AT 0°C (0°C - 25°C) X -0.113V/C + 40.29V = 43.1V). POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE WITH NEC 705.12(D). OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL. THE PV BREAKER SHALL NOT BE MARKED FOR "LINE" AND "LOAD". THE PV BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. 6 7 8 3 4 5 2 2 3 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703. THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) 1 GROUNDING NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER 1 THE DC AND AC CONNECTORS OF THE ENPHASE IQ7-60-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(A) AND NEC 690.17(E) GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 3 4 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.8 (D). SINGLE-LINE DIAGRAMPV-3 1 SINGLE-LINE DIAGRAM SCALE: NTS THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS.PV-3 9 8 7 GR I D - T I E D S O L A R P O W E R S Y S T E M REYES MANUEL RUIZ-DONATE 88991PE 9416 INTERNATIONAL CT ST PETERSBURG FL 32907 P-132296 ROOF NEMA 3R JUNCTION BOX BLACK - L1 RED - L2 GREEN - GROUND SOLADECK TYP AC COMBINER 20A BREAKER PER CIRCUIT ENGAGE CABLE #12 AWG THWN FOR FOME RUNS LESS THAN 100' #10 AWG THWN FOR HOME RUNS OVER 100' (1) LINE 1 (1) LINE 2 PER CIRCUIT #8 AWG THWN (1) EGC INSIDE AT LEAST 3/4 " CONDUIT TBD ON SITE #8 AWG THHN (1) LINE 1 (1) LINE 2 (1) NEUTRAL #8 AWG (1) EGC IN @ LEAST 3 4" CONDUIT TYPICALLY 60 A SERVICE RATED FUSED DISCONNECT NEUTRAL TO GROUND BOND 50 A FUSE MANUAL DISCONNECT METER N #8 AWG THHN (1) LINE 1 (1) LINE 2 (1) NEUTRAL #8 AWG (1) EGC IN @ LEAST 3 4" CONDUIT TYPICALLY MAIN DISTRIBUTION PANEL 150A MAIN SUPPLY SIDE G 60 A SERVICE RATED FUSED DISCONNECT NEUTRAL TO GROUND BOND MANUAL DISCONNECT METER N#8 AWG THHN (1) LINE 1 (1) LINE 2 (1) NEUTRAL #8 AWG (1) EGC IN @ LEAST 3 4" CONDUIT TYPICALLY MAIN DISTRIBUTION PANEL 200A MAIN WITH MAIN DERATED TO 150 A LOAD SIDE OPTIONAL G 50 A DATE: 6/1/20 56 0 1 C A S S I A D R FO R T P I E R C E , F L 3 4 9 8 2 EACH DISCONNECTING MEANS FORPHOTOVOLTAIC EQUIPMENT (C1)! WARNING !ELECTRIC SHOCK HAZARD. DO NOT TOUCHTERMINALS. TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZED IN THE OPENPOSITION.NEC 690.17(E)AC DISCONNECT 3 MAXIMUM AC OPERATING CURRENT: 32.6 AMAXIMUM AC OPERATING VOLTAGE: 240V 4 NEC 690.54PHOTOVOLTAIC SYSTEM EQUIPPEDWITH RAPID SHUTDOWNNEC 690.56(C) AND IFC 605.11.1 A N Y A C E L E C T R I C A L P A N E L T H A T I S F E D B Y B O T H T H E U T I L I T Y A N D T H E P H O T O V O L T A I C S Y S T E M ( M S P ) ! W A R N I N G ! D U A L P O W E R S O U R C E . S E C O N D S O U R C E I S P H O T O V O L T A I C S Y S T E M . NE C 7 0 5 . 1 2 ( D ) ( 3 ) S O L A R B R E A K E R ! W A R N I N G ! I N V E R T E R O U T P U T C O N N E C T I O N . D O N O T R E L O C A T E T H I S O V E R C U R R E N T D E V I C E . NE C 7 0 5 . 1 2 ( D ) ( 2 ) ( 3 ) ( B ) P H O T O V O L T A I C A C D I S C O N N E C T NE C 6 9 0 . 1 3 ( B ) S O L A R B A C K F E E D B R E A K E R A S M A I N A C S O L A R D I S C O N N E C T ( C B 1 I N M S P ) L A B E L I N G N O T E S A L L P L A Q U E S A N D S I G N A G E R E Q U I R E D B Y 2 0 1 4 N E C A N D 2 0 1 5 N F P A 1 W I L L B E I N S T A L L E D A S R E Q U I R E D . 2 L A B E L S , W A R N I N G ( S ) A N D M A R K I N G S H A L L C O M P L Y W I T H A N S I Z 5 3 5 . 4 , W H I C H R E Q U I R E S T H A T D A N G E R , W A R N I N G , A N D C A U T I O N S I G N S U S E D T H E S T A N D A R D H E A D E R C O L O R S , H E A D E R T E X T , A N D S A F E T Y A L E R T S Y M B O L O N E A C H L A B E L . T H E A N S I S T A N D A R D R E Q U I R E S A H E A D I N G T H A T I S A T L E A S T 5 0 % T A L L E R T H A N T H E B O D Y T E X T , I N A C C O R D A N C E W I T H N E C A P E R M A N E N T P L A Q U E O R D I R E C T O R Y S H A L L B E I N S T A L L E D P R O V I D I N G T H E L O C A T I O N O F T H E S E R V I C E D I S C O N N E C T I N G M E A N S A N D T H E P H O T O V O L T A I C S Y S T E M D I S C O N N E C T I N G M E A N S I F N O T I N T H E S A M E L O C A T I O N I N A C C O R D A N C E W I T H N E C 6 9 0 . 5 6 ( B ) . L A B E L ( S ) W I T H M A R K I N G , " P H O T O V O L T A I C S Y S T E M E Q U I P P E D W I T H R A P I D S H U T D O W N , " S H A L L B E L O C A T E D A T P O I N T - O F - I N T E R C O N N E C T I O N O R A T M A I N S E R V I C E D I S C O N N E C T T H E L A B E L S H A L L H A V E 3 / 8 ” T A L L L E T T E R S A N D B E R E F L E C T I V E W I T H W H I T E T E X T O N A R E D B A C K G R O U N D P - 1 3 2 2 9 5 S A F E T Y L A B E L S R E V I E W E R : R . R . P V - 4 123456 1 R E Y E S M A N U E L R U I Z - D O N A T E 8 8 9 9 1 P E 9 4 1 6 I N T E R N A T I O N A L C T S T P E T E R S B U R G F L 3 2 9 0 7 GRID-TIED SOLAR POWER SYSTEM P - 1 3 2 2 9 6 MSP - MAIN SERVICE PANEL4 1 AC COMBINER BOXMANUAL DISCONECT23FLA S H I N G C O U N T B Y R O O F T Y P E SHINGLE ()TILE ( S / W ) M E T A L / F L A T ( 5 5 ) T I L E ( F L A T ) 7817UTILITY METER4 7 P H O T O V O L T A I C S Y S T E M C O M B I N E R P A N E L D O N O T A D D L O A D S N E C 6 9 0 . 1 3 ( B ) W A R N I N G : P H O T O V O L T A I C P O W E R S O U R C E A C C O M B I N E R 7 W A R N I N G : P H O T O V O L T A I C P O W E R S O U R C E N E C 6 9 0 . 1 3 ( B ) W A R N I N G : P H O T O V O L T A I C P O W E R S O U R C E A C C O M B I N E R 8 D A T E : 6 / 1 / 2 0 5601 CASSIA DR FORT PIERCE, FL 34982 ATTACHMENT PLAN REVIEWER: R.R. PV-5 GR I D - T I E D S O L A R P O W E R S Y S T E M REYES MANUEL RUIZ-DONATE 88991PE 9416 INTERNATIONAL CT ST PETERSBURG FL 32907 GR I D - T I E D S O L A R P O W E R S Y S T E M P-132296STRUSS LOCATION IS APROXIMATE. LAYOUT SUBJECT TO CHANGE DUE TO ROOF OBSTRUCTIONS. ATTACHMENTS ARE APROXIMATED, ALSO MAY CHANGE DUE TO LACATION OF STRUSS. 3 FT DATE: 6/1/20 56 0 1 C A S S I A D R FO R T P I E R C E , F L 3 4 9 8 2 GENERAL NOTES 1 2 ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS (WINDOWS OR DOORS), ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION, AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS (TREE LIMBS, WIRES, OR SIGNS). (NFPA 1 11.12.2.2.1.3) PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A MANNER THAT PROVIDES A 3 FT WIDE CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE OF EACH ROOF SLOPE WHERE THE PHOTOVOLTAIC MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE LOCATED AT A STRUCTURALLY STRONG LOCATION OF THE BUILDING, SUCH AS A BEARING WALL, EXCEPT WHERE ADJOINING ROOF PLANES PROVIDE A 3 FT WIDE CLEAR ACCESS PATHWAY. (NFPA 1 11.10.2.2.2.1.1) PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS THAN 3 FT BELOW THE RIDGE. (NFPA 1 11.10.2.2.2.2) 1.5 FT. WIDE FIRE ACCESS PATHWAY 3.0 FT. WIDE SMOKE-VENTILATION SETBACK, PER NFPA 1 11.10.2.2.2.2 ROOF ACCESS POINT THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. FIRE SAFETY PLAN PV-6 3 1 2 3 4 6 7 REVIEWER: R.R. REYES MANUEL RUIZ-DONATE 88991 PE 9416 INTERNATIONAL CT ST PETERSBURG FL 32907 GR I D - T I E D S O L A R P O W E R S Y S T E M PV MODULES INSTALLED ON ROOF WITH UNIRAC SOLARMOUNT MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 5/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1, 2, 3, OR 10 MODULES. THE Q-CELLS Q.PEAK DUO BLK-G5 315 IS TYPE 1. P-132296 2 2 2 3 3 DATE: 6/1/20 56 0 1 C A S S I A D R FO R T P I E R C E , F L 3 4 9 8 2 56 01 Cassia D r Reyes Ruiz-Donate ADDRESSADDRESS 5601 Cassia Dr, Fort Pierce, FL 34982, USA, 34982 Created for 9.18kW 27 B 160 mph 0 psf 1342.84 lbs 1 SPECIFICATIONSSPECIFICATIONS Total PowerTotal Power Total ModulesTotal Modules Wind Exposure CategoryWind Exposure Category ASCE 7-10 Wind SpeedASCE 7-10 Wind Speed Ground Snow LoadGround Snow Load Total Project WeightTotal Project Weight Total numbers of arraysTotal numbers of arrays Composition Shingle 24 '' II IBC 2018, IRC 2018 CBC/CRC 2019, FBC/FRC 2017 STRUCTURALSTRUCTURAL Roofing TypeRoofing Type Rafter Spac ingRafter Spac ing Building Risk CategoryBuilding Risk Category Code ComplianceCode Compliance Reyes Ruiz-Donate reyes@ehsfl.c om 6/1/2020 ADDITIONAL INFORMATIONADDITIONAL INFORMATION Created ByCreated By User EmailUser Email CreatedCreated 5601 Cassia Dr Page 1 5601 Cassia Dr Page 2 Bi ll of MaterialsBill of Materials ManufacturerManufacturer PartPart Product CodeProduct Code ProjectProject TotalTotal Price/Price/ EAEA TotalTotal priceprice ModulesModules *Q CELLS Q .PEAK BUO BLK-G6 340W 27 0 0 Rails & SplicesRails & Splices Quick Mount PV Q MR-RL14 A 0800 14 42.41 593.74 Quick Mount PV Q MR-ISL A 0830 6 7.6 45.6 Clamps & GroundingClamps & Grounding Quick Mount PV Q MR-UEC3045 A 0943 16 3.85 61.6 Quick Mount PV Q MR-UMC3045 A 0935 46 3.85 177.1 Quick Mount PV Q MR-GLQ A 0888 4 7.04 28.16 Mounts & L-FeetMounts & L-Feet Quick Mount PV Q MLM A 0151 55 11.25 618.75 AccessoriesAccessories Quick Mount PV Q MR-TB A 0880 55 0.99 54.45 Quick Mount PV Q MR-WC A 0892 54 0.41 22.14 MSRP: $1601.54$1601.54 Discount: 0% ($0.00)($0.00) Total Pric e: $1601.54$1601.54 Mount Mid Clamp End Clamp Ground Lug Rail Rafter QSkirt Array1Array1 9 .18kW 27 180° 30' 26° or 5:12 24" Power Output:Power Output: Modules:Modules: Azimuth:Azimuth: Roof Height:Roof Height: Roof Slope:Roof Slope: Rafter Spa cing :Rafte r Sp acing: 46 16 13 42.838 lbs 24.415 lbs 1 58.294 lbs 2.578 psf *Q CELLS, Q.PEAK BUO BLK-G6 340W*Q CELLS, Q.PEAK BUO BLK-G6 340W 68.5" Long x 40.55" Wide68.5" Long x 40 .55" Wide Number Of Mid Clamps:Number Of Mid Clamps: Number Of End Clamps:Number Of End Clamps: Total System Weight:Total System Weight: Weight/Attachment:Weight/Attachment: Racking Weight:Racking Weight: Distributed Weigh t:Distributed Weig ht: Yes Max Cantilever:Max Cantilever: Roof Zone 1: 23"23" Roof Zone 2: 16.3"16.3" Roof Zone 3: 13.3"13.3" Max Mount Spacing:Max Mo unt Spacing: Roof Zone 1: 48"48" Roof Zone 2: 48"48" Roof Zone 3: 24"24" Staggered Mounts Required :Staggered Mounts Required: 5601 Cassia Dr Page 3 The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while EGLMIZMRKXLILMKLIWXW]WXIQIJƤGMIRG] Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase )RPMKLXIRƎQSRMXSVMRKERHEREP]WMWWSJX[EVI IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading [EVVERX]SJYTXS]IEVW Enphase IQ 7 and IQ 7+ Microinverters To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverters Region: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements ŵ 'SRƤKYVEFPIJSVZEV]MRKKVMHTVSƤPIW • Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com k)RTLEWI)RIVK]%PPVMKLXWVIWIVZIH%PPXVEHIQEVOWSVFVERHWYWIHEVIXLITVSTIVX]SJ)RTLEWI)RIVK]-RG 2018-11-19 INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-US Commonly used module pairings¹ 235 W - 350 W + 235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 60 V Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A 4:EVVE]GSRƤKYVEXMSR 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range² 240 V / 211-264 V 208 V / 183-229 V 240 V / 211-264 V 208 V / 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit³ 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor (adjustable) 0.85 leading ... 0.85 lagging 0.85 leading ... 0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V 4IEOIJƤGMIRG]97.6 % 97.6 % 97.5 % 97.3 % ')'[IMKLXIHIJƤGMIRG]97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range -40ºC to +65ºC Relative humidity range 4% to 100% (condensing) Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: - PV2 to MC4: order ECA-S20-S22 - PV2 to UTX: order ECA-S20-S25 Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.38 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environmental category / UV exposure rating NEMA Type 6 / outdoor FEATURES Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions. Enphase IQ 7 and IQ 7+ Microinverters Q.ANTUM TECHNOLOGY: LOW LEVELISED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information. YIELD SECURITY ANTI PID TECHNOLOGY (APT) HOT-SPOT PROTECT (HSP) TRACEABLE QUALITY (TRA.QTM) ANTI LID TECHNOLOGY (ALT) www.VDEinfo.comID. 40032587 Quality Tested high reliability low degradation optimized durabilitycontinous line monitoring 11/2016 EN THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Q.PEAK DUO BLK-G6 330-345 ENDURING HIGH PERFORMANCE DETAIL A 16 mm 8.5 mm24.5 mm 980 mm 1740 mm 4 × Mounting slots (DETAIL A) Frame 1030 mm 981 mm 32 mm 8 × Drainage holes 380 mm EN 4 × Grounding points ø 4.5 mm Label ≥1150 mm ≥1150 mm EN RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P O W E R [ % ] 100 95 90 85 80 75 155 2520010 YEARS 98 Q CELLS Industry standard for tiered warranties* Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] α [% / K]+0.04 β [% / K]− 0.27 γ [% / K]−0.36 NMOT [°C]43 ± 3 [V]1000 II [A]20 C [Pa]3600 / 2667 − 40 °C - +85 °C [Pa]5400 / 4000 32 28 24 1815 × 1150 × 1190 mm 683 kg 330 335 340 345 [W]330 335 340 345 [A]10.41 10.47 10.52 10.58 [V]40.15 40.41 40.66 40.92 [A]9.91 9.97 10.02 10.07 [V]33.29 33.62 33.94 34.25 [%]≥ 18.4 ≥ 18.7 ≥ 19.0 ≥ 19.3 [W]247.0 250.7 254.5 258.2 [A]8.39 8.43 8.48 8.52 [V]37.86 38.10 38.34 38.59 [A]7.80 7.84 7.89 7.93 [V]31.66 31.97 32.27 32.57 Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power dur- ing first year. Thereafter max. 0.54 % degradation per year. At least 93.1 % of nominal power up to 10 years. At least 85 % of nominal power up to 25 years. All data within measurement toler- ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2). Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q CE L L S Q. P E A K D U O B L K - G 6 _ 3 3 0 - 3 4 5 _ 2 0 1 9 - 0 3 _ R e v 0 1 _ E N PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS Safety Class Maximum Reverse Current IR Fire Rating Max. Design Load, Push / Pull Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 G according to IEC 60904-3 • 2800 W/m², NMOT, spectrum AM 1.5 G QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION VDE Quality Tested, IEC 61215:2016; IEC 61730:2016, Application Class II; This data sheet complies with DIN EN 50380. Number of Modules per Pallet Number of Pallets per Trailer (24 t) Number of Pallets per 40' HC-Container (26 t) Pallet Dimensions (L × W × H) Pallet Weight MECHANICAL SPECIFICATION Format 1740 mm × 1030 mm × 32 mm (including frame) Weight 19.9 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mm Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 1150 mm, (−) ≥ 1150 mm Connector Stäubli MC4, Amphenol UTX, Renhe 05-6, Tongling TL-Cable01S, JMTHY JM601; IP68 or Friends PV2e; IP67 TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Normal Module Operating Temperature QR a i l — F u l l y I n t e g r a t e d M o u n t i n g a n d R a c k i n g S y s t e m Th e Q R a i l S e r i e s i s a s t r o n g a n d v e r s a t i l e s o l a r a r r a y m o u n t i n g s y s t e m t h a t p r o v i d e s u n r i v a l e d b e n e f i t s t o s o l a r de s i g n e r s a n d i n s t a l l e r s . C o m b i n e d w i t h Q u i c k M o u n t P V ’ s i n d u s t r y - l e a d i n g w a t e r p r o o f m o u n t s , Q R a i l o f f e r s a co m p l e t e r a c k i n g s o l u t i o n f o r m o u n t i n g s o l a r m o d u l e s o n a n y r o o f . QR a i l , t o g e t h e r w i t h Q u i c k M o u n t P V ’ s w a t e r p r o o f m o u n t i n g p r o d u c t s , p r o v i d e s t h e b e n e f i t o f a s i n g l e - s o u r c e d , se a m l e s s l y i n t e g r a t e d r o o f t o p i n s t a l l a t i o n t h a t w o r k s w i t h a l l r o o f t y p e s — c o m p o s i t i o n / a s p h a l t s h i n g l e s , fl a t o r c u r v e d t i l e , m e t a l s h i n g l e , s h a k e , s l a t e a n d l o w s l o p e r o o f s . T h e Q R a i l s y s t e m a l s o w o r k s w i t h a n y r o o f at t a c h m e n t s y s t e m f o r m a x i m u m f l e x i b i l i t y . Co m p r e h e n s i v e , O n e - S o u r c e S o l u t i o n Fa s t , S i m p l e I n s t a l l a t i o n : I t J u s t C l i c k s Th e Q R a i l s y s t e m p r o v i d e s a n i n t e g r a t e d e l e c t r i c a l b o n d i n g p a t h , e n s u r i n g t h a t a l l e x p o s e d m e t a l p a r t s a n d th e s o l a r m o d u l e f r a m e s a r e e l e c t r i c a l l y c o n n e c t e d . A l l e l e c t r i c a l b o n d s a r e c r e a t e d w h e n t h e c o m p o n e n t s a r e in s t a l l e d a n d t i g h t e n e d d o w n . Fu l l y I n t e g r a t e d E l e c t r i c a l B o n d i n g QC l i c k T e c h n o l o g y Th e u n i v e r s a l m i d a n d e n d c l a m p s u s e p a t e n t e d Q C l i c k te c h n o l o g y t o s i m p l y “ c l i c k ” i n t o t h e r a i l c h a n n e l a n d re m a i n u p r i g h t , r e a d y t o a c c e p t t h e m o d u l e . T h e pr e - a s s e m b l e d c l a m p s f i t v i r t u a l l y a l l m o d u l e f r a m e s a n d re q u i r e n o e x t r a h a r d w a r e , e l i m i n a t i n g p r e - l o a d i n g a n d re d u c i n g i n s t a l l a t i o n t i m e . Su p e r i o r S t r e n g t h a n d V e r s a t i l i t y QR a i l i s e n g i n e e r e d f o r o p t i m a l s t r u c t u r a l p e r f o r m a n c e . T h e s y s t e m i s c e r t i f i e d t o U L 2 7 0 3 , f u l l y c o d e c o m p l i a n t a n d b a c k e d b y a 2 5 - y e a r wa r r a n t y . Q R a i l i s a v a i l a b l e i n L i g h t , S t a n d a r d a n d H e a v y v e r s i o n s t o ma t c h a l l g e o g r a p h i c l o c a t i o n s . Q R a i l i s c o m p a t i b l e w i t h v i r t u a l l y a l l mo d u l e s a n d w o r k s o n a w i d e r a n g e o f p i t c h e d r o o f s u r f a c e s . M o d u l e s ca n b e m o u n t e d i n p o r t r a i t o r l a n d s c a p e o r i e n t a t i o n i n s t a n d a r d o r sh a r e d - r a i l c o n f i g u r a t i o n s . S TA N D A R D L IG H T 1 2 3 click !click!2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL E ND C L AMP 2 clamps for modules from 30-45mm or 38-50mm thickUNIVERSAL B ONDED M ID C L AMP QR a i l ’ s i n n o v a t i v e i n t e r n a l Q S p l i c e i n s t a l l s i n s e c o n d s , r e q u i r i n g n o to o l s o r s c r e w s . S i m p l y i n s e r t Q S p l i c e i n t o t h e r a i l a n d s l i d e t h e o t h e r ra i l o n t o c r e a t e a f u l l y s t r u c t u r a l , b o n d e d s p l i c e . A n e x t e r n a l s p l i c e i s al s o a v a i l a b l e . QS p l i c e T e c h n o l o g y QS P L I C E H EA V Y QR a i l s c o m e i n t w o l e n g t h s — 16 8 i n c h e s ( 1 4 f t ) a n d 2 0 8 i n c h e s ( 1 7 . 3 f t ) ™ ™ 2 3 1 Mi l l a n d B l a c k F i n i s h In s t a l l s i n s e c o n d s — n o t o o l s o r h a r d w a r e r e q u i r e d In s t a l l i n g i s a s e a s y a s 1 - 2 - 3 Ea s i l y d e s i g n a r r a y c o n f i g u r a t i o n s w i t h t h e Q D e s i g n s o f t w a r e ap p l i c a t i o n . G e n e r a t e c o m p l e t e e n g i n e e r i n g r e p o r t s a n d c a l c u l a t e a p r e c i s e b i l l o f m a t e r i a l s f o r a l l t h e m o u n t i n g , r a c k i n g a n d ac c e s s o r i e s n e e d e d f o r a c o m p l e t e s o l a r a r r a y . ™ ® www.roof-tech.us info@roof-tech.us RT-MINI Self-flashing base for asphalt & metal roof-top PV mounting systems Dual bolt design: M8 or 5/16” for L-Foot & 1/4” for EMC 1/4” Hex Bolt upper channel Easy tapping screw guide M8 or 5/16” Hex Bolt bottom channel Flat lip for PV Cable clips RT-MINI is suitable for mounting any rail system with a conventional L-Foot. Call Now for more details 858-935-6064 ICC ESR 3575 RT-MINI Flexible Flashing certified by the International Code Council (ICC) Components RT2-00-MINIBK MINI base : 20 ea. Screw : 40 ea. Extra RT-Butyl : 10 ea. RT-Butyl is Roof Tech s flexible flashing used in 550,000 residential PV systems for the last 20 years. It is the first PV mounting system with Flexible Flashing certified by the ICC. ICC ESR-3575 ASTM2140 testing UV testing (7500 hrs.) www.roof-tech.us info@roof-tech.us 10620 Treena Street, Suite 230, San Diego, CA 92131 858.935.6064 Roof Tech Inc. Flexible Flashing 100% Waterproof Metal Flashing Retrofit Shedding water? Ra"er installa#on Deck installa#on ’ P.E. Stamped Letters available at www.roof-tech.us/support PAT : PENDING Dimensions in (mm) (D Y H (D Y H Engineered to ASTM D 1761 (Standard Test Methods for Mechanical Fasteners in Wood)