Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION 4 Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 8129 Amalfi Circle Builder Name: Adams Homes of Northwest Florida, Inc. Street: 8129 Amalfi Circle Permit Office: St Lucie County City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Owner: Adams Homes Jurisdiction: 611000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1884.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1342.70 ft' 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 328.00 ft' c. Frame - Wood, Adjacent R=13.0 213.33 ft' 4. Number of Bedrooms 4 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (2413.0 soft.) Insulation Area a. Under Attic (Vented) R=30.0 2281.00 ft' 6. Conditioned floor area above grade (ft') 2281 b. Knee Wall (Vented) R=30.0 132.00 ft' Conditioned floor area below grade (ft') 0 c. NIA R ft' 11 •Ducts R ft' 7. Windows(288.5 soft.) Description Area a. Sup: Attic, Rat: Main, AH: Main 6 350 a. U-Factor: Dbl, U=0.33 233.76 ft' SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.29 32.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.16 a. Central Unit 35.0 SEER:15.00 c. U-Factor: Dbl, U=0.28 15.56 ft' SHGC: SHGC=0.16 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 7.22 ft' a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 6.068 ft. Area Weighted Average SHGC: 0.218 14. Hot water systems 8. Floor Types (2281.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ft' b. Conservation features EF: 0.950 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.126 Total Proposed Modified Loads: 67.09 -PASS Total Baseline Loads: 69.20 I hereby certify that the plans and specifications covered by Review of the plans and ` this calculation are in compliance with the Florida Energy specifications covered by this 04?f1�ST11� p Cade. calculation indicates compliance "/ i„ ' D{O (� with the Florida Energy Code. y E+ nni %. •;=' ;;' PREPARED BY: /�i{ Y ru Before construction is completed r DATE: this building will be inspected for compliance with Section 553.908 # ri I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Eoerov Code. Q0 t¢ OWNER/AGENT_ L BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this proje tres an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). �� 12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 8129 Amalfi Circle Bedrooms: 4 User Conditioned Area: 2281 Adams Homes Total Stories: 1 1 Worst Case: No Adams Homes of Northwest F Rotate Angle: 0 St Lucie County Cross Ventilation: 611000 Whole House Fan: Single-family New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlalBook: Street: 8129 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2281 18248 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2281 18248 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 228 ft 0 2281 ft2 — 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 2561 ft2 572 ft2 Medium N 0.85 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2281 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 30 Batt 2281 ft2 0.11 Wood 132 ft2 0.11 Wood 12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 -FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS ` Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 W Exterior Concrete Block - Int Insul Main 4.1 14 4 8 114.7 ft' 0 0.600000 0 2 W Exterior Concrete Block - Int Insul Main 4.0999 6 10 60.0 ft' 0 0.600000 0 3 W Exterior Concrete Block - Int Insul Main 4.0999 14 8 10 146.7 ft' 0 0.600000 0 4 W Garage Frame - Wood Main 13 22 0 8 176.0 ft' 0.23 0.600000 0 5 N Garage Frame -Wood Main 13 2 4 8 18.7 ft' 0.23 0.600000 0 6 S Garage Frame - Wood Main 13 2 4 8 18.7 ft' 0.23 0.600000 0 7 S Exterior Concrete Block - Int Insul Main 4,0999 46 8 8 373.3 ft' 0 0.600000 0 8 N Exterior Concrete Block - Int Insul Main 4.0999 33 8 8 269.3 ft' 0 0.600000 0 9 N Exterior Frame -Wood Main 13 8 8 8 69.3 ft' 0.23 0.600000 0 _ 10 E Exterior Frame - Wood Main 13 23 4 8 186.7 ft' 0.23 0.600000 0 _11 SE Exterior Frame - Wood Main 13 3 8 24.0 ft' 0.23 0.600000 0 12 S Exterior Frame - Wood Main 13 6 8 48.0 ft' 0.23 0.600000 0 _ 13 N Exterior Concrete Block - Int Insul Main 4.0999 47 4 8 378.7 ft' 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .21 3 6 8 20 ft' 2 NW Wood Main None .21 2 8 6 8 17.8ft- WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 W 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 6 It 2 in 3 ft 2 in None None 2 W 2 Vinyl Low-E Double Yes 0.29 0.16 N 14.2 ft' 1 ft 4 in 1 It 2 in None None 3 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 7.2 ft' 8 ft 4 in 1 It 2 in None None 4 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 37.0 ft' 1 ft 4 in 3 It 2 in None None 5 S 7 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft' 1 It 4 in 1 It 2 in None None 6 S 7 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft' 1 It 4 in 1 ft 2 in None None 7 N 8 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft' 1 It 4 in 1 ft 2 in None None 8 N 9 Vinyl Low-E Double Yes 0.29 0.16 N 17.8 ft' 23 ft 4 in 1 8 2 in None None 9 E 10 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft' 9 ft 4 in 1 ft 2 in None None 10 E 10 Vinyl Low-E Double Yes 0.33 0.23 N 15.0 ft' 9 ft 4 in 1 ft 2 in None None 11 SE 11 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft' 10 It 4 in 1 It 2 in None None 12 N 13 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 1 It 4 in 1 ft 2 in None None 13 S 12 Vinyl Low-E Double Yes 0.28 0.16 N 15.6 ft' 20 ft 4 in 1 ft 2 in None None 12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 476.3 ft' 476.3 ft' 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1520.7 83.48 157 .0881 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER: 15 35 kBlu/hr 1050 clin 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / V # — supply — Location R-Value Area — Return — Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 350 W Main 114.05 Default Leakage Main (Default) (Default) 1 1 12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2D17 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programabl[e, Thermostat: Y Ceiling Fans:Cooling Venting Jan jr[ Apr May [[[[ Jun Jul[[X]][[ ]] �X� Nov [[)(�) H Dec [ ] Feb Mar lxJ [X� l l Jul lXJ Aug Sep Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .ft. 0 it. 0 ft 0.3 Main 12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) GroundAvater source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 2281 d) Room unit/PTAC EER e) Other 15.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.323 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.218 14. Heating system: Capacity 34.6 c) Area 7c. 288.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. 30.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature. Date: Address of New Home: 8129 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951 1212812019 10:19:40 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1