HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
4 Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 8129 Amalfi Circle
Builder Name: Adams Homes of Northwest Florida, Inc.
Street: 8129 Amalfi Circle
Permit Office: St Lucie County
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner: Adams Homes
Jurisdiction: 611000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1884.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1342.70 ft'
3. Number of units, if multiple family 1
b. Frame - Wood, Exterior
R=13.0 328.00 ft'
c. Frame - Wood, Adjacent
R=13.0 213.33 ft'
4. Number of Bedrooms 4
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (2413.0 soft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2281.00 ft'
6. Conditioned floor area above grade (ft') 2281
b. Knee Wall (Vented)
R=30.0 132.00 ft'
Conditioned floor area below grade (ft') 0
c. NIA
R ft'
11 •Ducts
R ft'
7. Windows(288.5 soft.) Description Area
a. Sup: Attic, Rat: Main, AH: Main
6 350
a. U-Factor: Dbl, U=0.33 233.76 ft'
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.29 32.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.16
a. Central Unit
35.0 SEER:15.00
c. U-Factor: Dbl, U=0.28 15.56 ft'
SHGC: SHGC=0.16
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 7.22 ft'
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 6.068 ft.
Area Weighted Average SHGC: 0.218
14. Hot water systems
8. Floor Types (2281.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ft'
b. Conservation features
EF: 0.950
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.126 Total Proposed Modified Loads: 67.09
-PASS
Total Baseline Loads: 69.20
I hereby certify that the plans and specifications covered by
Review of the plans and
`
this calculation are in compliance with the Florida Energy
specifications covered by this
04?f1�ST11�
p
Cade.
calculation indicates compliance
"/
i„ ' D{O
(�
with the Florida Energy Code.
y
E+ nni %. •;=' ;;'
PREPARED BY: /�i{ Y ru
Before construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
# ri
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Eoerov Code.
Q0 t¢
OWNER/AGENT_ L
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this proje tres an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). ��
12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Pagel of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
8129 Amalfi Circle Bedrooms: 4
User Conditioned Area: 2281
Adams Homes Total Stories: 1
1 Worst Case: No
Adams Homes of Northwest F Rotate Angle: 0
St Lucie County Cross Ventilation:
611000 Whole House Fan:
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlalBook:
Street: 8129 Amalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2281 18248
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
2281 18248 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 228 ft 0
2281 ft2 — 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or shed Composition shingles 2561 ft2 572 ft2 Medium
N 0.85 No 0.9 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2281 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 30 Batt
2281 ft2 0.11 Wood
132 ft2 0.11 Wood
12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
-FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
`
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar Below
0
1
W
Exterior
Concrete Block - Int Insul
Main
4.1
14
4
8
114.7 ft'
0 0.600000 0
2
W
Exterior
Concrete Block - Int Insul
Main
4.0999
6
10
60.0 ft'
0 0.600000 0
3
W
Exterior
Concrete Block - Int Insul
Main
4.0999
14
8
10
146.7 ft'
0 0.600000 0
4
W
Garage
Frame - Wood
Main
13
22
0
8
176.0 ft'
0.23 0.600000 0
5
N
Garage
Frame -Wood
Main
13
2
4
8
18.7 ft'
0.23 0.600000 0
6
S
Garage
Frame - Wood
Main
13
2
4
8
18.7 ft'
0.23 0.600000 0
7
S
Exterior
Concrete Block - Int Insul
Main
4,0999
46
8
8
373.3 ft'
0 0.600000 0
8
N
Exterior
Concrete Block - Int Insul
Main
4.0999
33
8
8
269.3 ft'
0 0.600000 0
9
N
Exterior
Frame -Wood
Main
13
8
8
8
69.3 ft'
0.23 0.600000 0
_ 10
E
Exterior
Frame - Wood
Main
13
23
4
8
186.7 ft'
0.23 0.600000 0
_11
SE
Exterior
Frame - Wood
Main
13
3
8
24.0 ft'
0.23 0.600000 0
12
S
Exterior
Frame - Wood
Main
13
6
8
48.0 ft'
0.23 0.600000 0
_ 13
N
Exterior
Concrete Block - Int Insul
Main
4.0999
47
4
8
378.7 ft'
0 0.600000 0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft In
1
N
Insulated
Main
None
.21
3
6 8 20 ft'
2
NW
Wood
Main
None
.21
2
8
6 8 17.8ft-
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
IntShade Screening
1
W
1
Vinyl Low-E Double
Yes
0.33
0.23
N
32.4 ft'
6 It 2 in
3 ft 2 in
None None
2
W
2
Vinyl Low-E Double
Yes
0.29
0.16
N
14.2 ft'
1 ft 4 in
1 It 2 in
None None
3
W
2
Vinyl Low-E Double
Yes
0.33
0.21
N
7.2 ft'
8 ft 4 in
1 It 2 in
None None
4
W
3
Vinyl Low-E Double
Yes
0.33
0.23
N
37.0 ft'
1 ft 4 in
3 It 2 in
None None
5
S
7
Vinyl Low-E Double
Yes
0.33
0.23
N
16.2 ft'
1 It 4 in
1 It 2 in
None None
6
S
7
Vinyl Low-E Double
Yes
0.33
0.23
N
9.8 ft'
1 It 4 in
1 ft 2 in
None None
7
N
8
Vinyl Low-E Double
Yes
0.33
0.23
N
48.6 ft'
1 It 4 in
1 ft 2 in
None None
8
N
9
Vinyl Low-E Double
Yes
0.29
0.16
N
17.8 ft'
23 ft 4 in
1 8 2 in
None None
9
E
10
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft'
9 ft 4 in
1 ft 2 in
None None
10
E
10
Vinyl Low-E Double
Yes
0.33
0.23
N
15.0 ft'
9 ft 4 in
1 ft 2 in
None None
11
SE
11
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft'
10 It 4 in
1 It 2 in
None None
12
N
13
Vinyl Low-E Double
Yes
0.33
0.23
N
32.4 ft'
1 It 4 in
1 ft 2 in
None None
13
S
12
Vinyl Low-E Double
Yes
0.28
0.16
N
15.6 ft'
20 ft 4 in
1 ft 2 in
None None
12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
476.3 ft'
476.3 ft'
64 ft 8 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000254
1520.7 83.48 157 .0881 5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
None
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
None
Singl SEER: 15 35 kBlu/hr 1050 clin 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.95 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft'
DUCTS
/
V #
— supply —
Location R-Value Area
— Return — Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1
Attic 6 350 W Main
114.05 Default Leakage Main (Default) (Default)
1 1
12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2D17 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programabl[e, Thermostat: Y
Ceiling Fans:Cooling
Venting Jan
jr[
Apr
May
[[[[
Jun
Jul[[X]][[
]]
�X�
Nov
[[)(�)
H Dec
[ ]
Feb
Mar
lxJ
[X�
l l Jul
lXJ Aug
Sep
Oct
[X] Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/s
.ft.
0 it.
0 ft
0.3
Main
12/28/2019 10:18 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
35.0
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) GroundAvater source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
2281
d) Room unit/PTAC EER
e) Other
15.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.323
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.218
14. Heating system: Capacity
34.6
c) Area
7c.
288.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
8.50
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
13.0
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
30.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature. Date:
Address of New Home: 8129 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951
1212812019 10:19:40 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1