Loading...
HomeMy WebLinkAboutProject InformationCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jun-04 16:11:21 Right-Suite® Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wrightsoft HVAC\DELGADO RENOVATION.rup Calc = MJ8 Front Door faces: S Job:Project Summary Jun 04, 2020Date:Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information DELGADO RENOVATIONFor: 125 SE NARANJA AVENUE, PORT ST LUCIE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90 Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15 Daily range M Relative humidity %50 Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh7211 Structure Btuh6823 Ducts Btuh1091 Ducts Btuh1620 Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none) Humidification Btuh0 Blower Btuh0 Piping Btuh0 Equipment load Btuh8302 Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load Btuh8022 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average 0Fireplaces Structure Btuh2154 Ducts Btuh420 Central vent (0 cfm)Btuh0 CoolingHeating (none) 535535Area (ft²)Equipment latent load Btuh2573 42804280Volume (ft³) Air changes/hour 0.320.61 Equipment Total Load (Sen+Lat)Btuh10595 Equiv. AVF (cfm)2344 Req. total capacity at 0.70 SHR ton1.0 Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Electric Make Mitsubishi Electric Trade Mitsubishi Electric Trade Mitsubishi Electric Model MUZ-HM12NA***Cond MUZ-HM12NA*** AHRI ref 202680601 Coil MSZ-HM12NA*** AHRI ref 202680601 Efficiency 10 HSPF Efficiency 9.9 EER, 18 SEER Heating input Sensible cooling Btuh8400 Heating output Btuh @ 47°F12200 Latent cooling Btuh3600 Temperature rise °F28 Total cooling Btuh12000 Actual air flow cfm400 Actual air flow cfm400 Air flow factor cfm/Btuh0.048 Air flow factor cfm/Btuh0.047 Static pressure in H2O1.00 Static pressure in H2O1.00 Space thermostat Load sensible heat ratio 0.77 Capacity balance point = 32 °F Backup: Input = 2 kW, Output = 7655 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jun-04 16:11:21 Right-Suite® Universal 2019 19.0.08 RSU08101 Page 1 ...ocumnets\Wrightsoft HVAC\DELGADO RENOVATION.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Jun 04, 2020Date:Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House FAMILY ROOM 2 Exposed wall 68.0 ft 61.0 ft 3 Room height 8.0 ft 8.0 heat/coolft 4 Room dimensions ft465.0x1.0 5 Room area 535.0 ft²465.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 176 176 616 337 120 120 420 229 .WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 168 156 546 298 168 156 546 298 .GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ss 18.2018.20 14.9914.99 12 12 218 180 12 12 218 180 .WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 200 168 588 321 200 168 588 321 11 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 32.0832.08 12 1 218 385 12 1 218 385 GG 2 glazing, clr low-e 0.6502 glazing, clr low-e 0.650 ww 18.2018.20 32.7632.76 20 1 366 659 20 1 366 659 CC 16B-19ad16B-19ad 0.0490.049 --1.371.37 2.452.45 535 535 734 1311 465 465 638 1139 FF 22A-tph22A-tph 1.3581.358 --38.0238.02 0.000.00 535 68 2586 0 465 61 2319 0 6 c) AED excursion 457 457 Envelope loss/gain 5872 3947 5314 3668 12 a) Infiltration 1339 376 1201 338 b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 2500 1500 Subtotal (lines 6 to 13)7211 6823 6515 5506 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 7211 6823 6515 5506 15 Duct loads 15%24%1091 1620 15%24%985 1308 Total room load 8302 8444 7500 6814 Air required (cfm)Air required (cfm)400 400 361 323 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Jun-04 16:11:21 Right-Suite® Universal 2019 19.0.08 RSU08101 Page 2 ...ocumnets\Wrightsoft HVAC\DELGADO RENOVATION.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Jun 04, 2020Date:Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 2 Exposed wall 7.0 ft 3 Room height 8.0 heat/coolft 4 Room dimensions ft10.0x7.0 5 Room area 70.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-5ocs 0.125 n 3.50 1.91 56 56 196 107 .W 13A-5ocs 0.125 s 3.50 1.91 0 0 0 0 .G 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 .W 13A-5ocs 0.125 w 3.50 1.91 0 0 0 0 11 G 2 glazing, clr low-e 0.650 w 18.20 32.08 0 0 0 0 G 2 glazing, clr low-e 0.650 w 18.20 32.76 0 0 0 0 C 16B-19ad 0.049 -1.37 2.45 70 70 96 172 F 22A-tph 1.358 -38.02 0.00 70 7 266 0 6 c) AED excursion 0 Envelope loss/gain 558 279 12 a) Infiltration 138 39 b) Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 1000 Subtotal (lines 6 to 13)696 1317 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 696 1317 15 Duct loads 15%24%105 313 Total room load 801 1630 Air required (cfm)39 77 ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������