HomeMy WebLinkAboutEnergy CodeEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 46/4/2020 4:08 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
DELGADO RENOVATION
Street:
City, State, Zip: PORT ST LUCIE , FL ,
125 SE NARANJA AVENUE
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
Addition
Single-family
1
No
535
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 44.00 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 535.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Int Insul, Exterior R=5.0 544.00 ft²
b. N/A R=f t ²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=19.0 535.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
12. Cooling systems
13. Heating systems
14. Hot water systems
a . Cap: N/A
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:2.000 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
- None required
(Bedrms In Addition) 0(0)
(44.0 sqft.)
(544.0 sqft.)
(535.0 sqft.)
(535.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Heat Pump
k B t u / h r
12.0 SEER:18.00
Efficiency
k B t u / h r Efficiency
17.0 HSPF:10.00
f t ² R
EF: 0.000
Glass/Floor Area: 0.082
Total Proposed Modified Loads:
Total Baseline Loads:
13.53
16.50 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). (Exception may apply)
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
6-8-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
1
DELGADO RENOVATION
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
535
0
Addition
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
PORT ST LUCIE ,
St. Lucie
125 SE NARANJA AVE
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 535 4280
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 FAMILY ROOM 465 3720 No 0 Yes Yes1 Yes
2 BATH 70 560 No 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 465 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -061 ft FAMILY ROOM
2 70 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -07 ft BATH
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Gable or Shed Composition shingles 579 ft² Medium 0.6 0 22.6______No112 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 535 ft² N N150
6/4/2020 4:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)19 465 ft² 0.1 Wood______FAMILY ROOM Blown
2 Under Attic (Vented)19 70 ft² 0.1 Wood______BATH Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 5 0FAMILY ROO 00015 8N Concrete Block - Int Insul 0.60Exterior120.0 ft² ____
2 5 0FAMILY ROO 00021 8S Concrete Block - Int Insul 0.60Exterior168.0 ft² ____
3 5 0FAMILY ROO 00025 8W Concrete Block - Int Insul 0.60Exterior200.0 ft² ____
4 5 0BATH0007 8N Concrete Block - Int Insul 0.60Exterior56.0 ft² ____
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 S Low-E Single 0.65 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes2 N
2 W Low-E Single 0.65 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes3 N
3 W Low-E Single 0.65 0.25 20.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______Yes3 N
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
499.3 727.41.000356Wholehouse .123351.55Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Heat Pump/Supplemen HSPF:10 17 kBtu/hr ______DuctlessSplit1 Single
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/Supplemental for a SEER: 18 12 kBtu/hr 360 cfm 0.8______DuctlessSplit1 Single
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
6/4/2020 4:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 FAMILY ROOM
Default(8 lbs/sq.ft.f t ² f t 0.3 BATH
6/4/2020 4:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������