Loading...
HomeMy WebLinkAboutConstruction Plans7 - CODES: -FLORIDA BUILDING CODE 6TH EDITION (2017). -THE ALUMINUM DESIGN MANUAL, CURRENT EDITION. -ASCE 7-10. -DESIGN WIND PRESSURES DERIVED FROM ASCE 7-10 AND PER FBC SECTION 1609 AND TABLE 2002.4. - OCCUPANCY: SINGLE FAMILY HOME - SCREEN ENCLOSURE - STRUCTURE: OPEN - BUILDING HEIGHT: < 60 FEET - MEAN ROOF HEIGHT: 9'-0" - BASIC WIND SPEED: 150 MPH - RISK CATEGORY I - EXPOSURE CATEGORY: B - WIND PRESSURES: - 9 PSF SCREEN ROOF - 31 PSF WALLS 25 PSF SOLID ROOF - ROOF DEAD LOAD: 0 PSF FOR WIND LOAD CALCULATIONS - ACCORDING TO RATIONAL ANALYSIS THE EXISTING STRUCTURE AND ATTACHMENT TO FASCIA CAN SUPPORT GRAVITY, UPLIFT, AND LATERAL LOADS IMPOSED BY SCREEN ENCLOSURE - PROJECT HAS BEEN REVIEWED FOR SHEAR WALL REQUIREMENTS - NO IMPACT PROTECTION IS REQUIRED FOR SCREEN ENCLOSURES - SOIL BEARING CAPACITY FOR FOUNDATIONS: EXISTING, ASSUMED TO BE WELL COMPACTED AT 2000 PSF - CONCRETE SHALL RAVE A MINIMUM COMPRESSIVE STRENGTH OF 3.000 PSI AFTER 28 DAYS. - ALL BEAMS AND COLUMNS ARE "LAB BEAMS", UNLESS NOTED OTHERWISE. cn E5 r� H z GENERAL NOES: 1. DESIGN IS BASED ON 6005-T5 ALUMINUM ALLOY. 2. CONTRACTOR MAY ADJUST DOOR LOCATION IN FIELD PER HOMEOWNERS REQUEST. 3. 18 X 14 OR 20 X 20 SCREEN MESH MAY BE USED. 4. ENGINEER HAS NOT VISITED THE JOB SITE AND SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANYWAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS THAT HAVE BEEN PROVIDED BY THE CONTRACTOR. WORK SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. T 7,-5. Lt F'--- 8'4' INSULATED ROOF SYSTE (APPROVAL # FL-7561-114) 2' 18' 2, 22' PLAN VIEW FRONT ELEVATION PER THE FLORIDA BUILDING CODE 61h EDITION (2017) FOR FOUNDATIONS AD LOAD = 25 2.0 PSF PSF w �. TAL qz = qz -DEAD LOAD = EA OF ROOF = 23.0 396 PSF SF F+ NO UPLIFT = TOTAL gz'•ROOF AREA = 9 108 LBS Q U O FETY FACTOR - SF = SF•WIND UPLIFT = 1.67 15 210 LBS TAL WIND UPLIFT = 3 ax :TIGHT OF CONCRETE (A)= EXIST. BUILDING) (B) = 144 58 PCF FT RIMETER OF SCREEN (EXCLUDING RIMETER OF EXIST. BUILDING RESISTING UPLIFT (EB) = 22 Fr 'UFT RESISTED BY EXIST. BUILDING (UB) = 7,605 LBS W EIGHT OF CONC. FOOTING = A•B•WIDTH•DEPTH = F IICKNESS OF CONC. SLAB (C) = 8 352 N/A LBS FT 44 o tEA OF CONC. SLAB CONSIDERED IN CALCULATION (D) = EIGHT OF CONIC. SLAB = A'•C-D = S N/A N/A SF LBS V " )TAL RESISTING FORCE = S+F+LIB = 15,957 LBS Go 1MMARY: 15,9S7 > 1S,210 —8'-3"—I rz&D-� _v( 55' REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC ®' =Z:U) a lu :Z ;t 0 r'.0 J; RECEIVED MAR 0 5 2020 ST. Lucie County, Permitting EXIST. FOUNDATION DETAIL Le:rkm.<?.f :ki..�'tiv Tilt.• �;��}�7 12" x 12" CONCRETE FOOTER W/ l (2) #5 REBAR BENEATH PAVERS Ell ki is FL DATE 03/03/2020 DSM E KENNEDY DRWN: E KENNEDY M. E KENNEDY SCALE: N.T.S. DWG. No. 1 0/ 4 2• COLUMN PER 'sumo 12MIL NOTES• 1) DI9OM AND CONSTRUCTION SHALL CONFORM TO THE NODUIRE1FNTS OF THE FUmGA BUDDING CODE SIN IDXIION (2017L RE ALamm DESIGN MANUAL (MMff EGRION), AND ASCE 7-10. 2) DETAILS ARE BASED ON DESIGN PRESSURES TAIH ULTWME WIRD SPEED - 160 MPH, DPOSURE C. RISK CATEGORY A AND 20 X 20 MESH WITH > 60% SCIm OPENINGS. 3) MINNIUM IN%E'DGOARTER WAM MINIMUM HEAD SHALL AND/OR1/2*.WITH A BE 4) ALL FASTENERS SHALL BE 2D24-74 ALUMINUM ALOY. NON-MAGNERC SWNIFSS STEEL. CABWUM pWED STEEL OR OTHERWISE CORROSION RESISTANT MATERIAL ALL FASTENERS SHALL COMPLY WITH 5.1.1C, GpECMTNTN9 FOR ALUMINUM STRUCTURES - SECTION 1. THE ALUMNNI A450DIATNIN. PG, AND APFIXAB E FEDEPAL. STATE, AND LOCAL CODES. 5) ALL TRCONG 94ALL BE 1 D/4' MOINU EMBED CRUDE3' MINIMUM DISTANCE FROM EDGE OF CONCRETE 6) ALL CONCRETE MOM SIIML HAVE A 1-3/4' MINIMUM EMBED AND 3' UMMUM DISTANCE FROM EOM OF CONCRETE 7) ALL E�C� SNAL BE PROTECTED FROM DISSIIUR METALS TO PRBW 8) DESIGN IS BASED ON 60OS-T5 ALUMINUM ALLOY. CORNER COLUMN N.T.S ETML T RCOU LED B COLUMN) R NNG DETAIL I OA75' 3X3 P T-2- TLP T 2%4P 2' t „0.OSS' 2X4 P 'N• BRACE' (SEE NOTE 4) 'K sumF(SEE NOTE 3) .X. BRACEJ Ti (SEE NOTE 4) (SEE Jigs: 1) PROVIDE UIFL 3/4• KTWEN FASIF3CEP5 AND MN 1/2* EDGE DISTANCE 2) PROM A WIN. OF TWO FASTENENS PER MEUREF. 3) -W BRACE W%DEi USE 3 064• MN. PLATE ORU k017J•XB'XO.OW UN. ANGLE / l(9))-1145MS./HEX HEMS. 4) VSWWirSE 3 X4-4.O i• UKOPLATE OR 4ko.os4• wIu uEai % (6)-f14 sHs/1IEESX IRMs. aK11IM BRACING DETAIL N.T.S 2X2 P EAVE 2X2 2.6X2.6 3%3 1 2• 4L0 6LB 6LB TLB.BLB, 9LB —9LB—H10LB LAP BEAM F-2'— �f 100ow 2X3XO.060 ffNYEiOEA SUMP 0� FAS 1# i9� 0.055' CIA ACE NTIE 3) 0VCE NOTE 4) SEAN TYPE 6 I. AILS .100 .046 OS' us .116 .OSO 6IB .120 .050 71B .120 .OSS BLR .224 .072 9lB M4 .072 OAIO' 9LI1 .306 .082 10LB .369 A92 102 CABLE CONNECTION A 9Ta14XLI fEKS 4'ANGLE.1250N � DEG CDT EYE BOLTFOR G191E TENSION &9'%3•EMBEDEDTAPCON B INTOSIDEOFFOOTIN0 O\, 4 MIN EDGE DISTANCE ® O CONCRETE FOOTING = Z ; W CABLE ATTACHMENT DETAIL i��i,, N.T.S. ZMO.060 OR 2X3)(0.050 0�4.87' 1• 3• UC! N� I 0.078' � � O.OSS• JTI SUPER GUTTER E-GUTTER 2X3SAVE 1144 X 2-EN IS' LONG T I 2• --� 2• ,1E� -CIF. 1• 2' 'I T• "I `I� 5A94' il y - � T l � J� 0.044 0.046• 0.010' il2X3X0. g%2 LGUTTER BRACE 202 1X2 1X3 1.75• �7F �' 2• �A^N 060 LL001'2 0. L 2X2 HHyH-9 riN 0.061' MEMBER EXTRUSIONS N.T.S TTyTa I 1nb� �0.084' C 1X2 C 1 33 C 2X2 C 2X3 File Copy AA I.► . N 0 4 9 DATE 03/D3/2020 OSGN: E NENNEDY DRINK. E RENNEDY CHM. E IONNEDY SCALE' N.T.S. DWG. NIL. 2 OF 4 F • (SEE NOTE 2) 4 2' 27 25' Mw. 3. MIN. /3± EIE PLAN (IBM.) CUP ANGLE DELETE 1X2 FOR OPEN FORT (TYP.) ,x2 FOOTING -:.. SECTION ' =_Wlw PER PUN R2x,/4• ANGLE FACH SIDE OF COLUM 0 62-(2 MR (4)-l12 X 1' LONG SLS TO COlumm (m) TAPCON W/ 2• UN. EMBED OR (0-3/8' X 4' MANSION 1/4• TAPCON W/ 2' ION. EYBFD A 18• O.C. ELSEWHEor NODS: 1) ANGLES ARE NOT REWIRED FOR 202 DOOR .OMB COLS. 2) FOR =%1NS S' DEEP OR LARGER NSTALL ADDIION& 2'X2-L2'XI/4' ANGLE EACH SIX: COLUMN ANCHORING N.TS CUTTER W/ (1)-l10 O 12' O.C. TOP 0 BOT (ION 3 PER PANEL) SEE COENN ANCHDMG DETAIL d CONCRETE FOOTING (PER PLAN) d (1)-1/4 TM -SCREW. W/ 1' WASHER (LAG BOLT SHALL BE A Eel. 1' LONGER THAN PANE. T100(NESS) CONC. STRUCTURE (2)-1/4' % 2-Ile TAPOON CLIP (SEE NOTE 2• x 2' X 1/8' CLIP ANGLE EA SDE W/ (2)-1/4• BOLT/0-SHEY IT OR (TO REAM (SEE NOTE 1) HE40 EA/ aP NOTES: 1) FOR 7LB OR LARGER USE (3)-1/4. 8DLT/WASHER/NUT OR (4)-010 S.NS/HEX HEAD 2) FOR SLB OR LARGER USE (3)-1/4. 2-1/4• TAPS EA CUP FA SIDE OF GUM BEAM TO CONC. WALL CONNECTION ILLS AImum FLANGE (OPRDNAL) 1/8' MNWUY THICWffSS 2- let CUP ANGLE W/ (2)-1/4• FASCA DDLTS/WA9&R/NUT TO BEAN AND (2)-1/4• X S LAO TO FASCIA \—SrAl Notes. 1) FOR 7LB OR GREATER USE (3)-1/4' BOLTS/kk%U/NUT TO BEAM AND (3) 1/4' x 3' LAG TO FASCIA BEAM CONNECTION AT FASCIA N SIZED PER PLAN 4'-0• MAIL WIDTH (IYPJ (LfNCN PER PLAN/PRODUCT APPROVAL.) 2' x 2• x I/W CUP ANGLE W/ W10 Sms/MIX HEAD EA FACE EA. SIDE TYPICAL ROOF PANEL MT.S J�CHNFI PAIL PER PUN (I) -Ile TEK-SCREW, W/ 1' WASHER (LAO BOLT SMALL BE A CON. 1' LONGER THAN COLININ PANEL TEDCINW) 0 8. O.C. (M) TYPICAL SECTION AT COLUMN N.T.S. N.T.S. (OPNONAL) CONC.�(')-nD SYS/IffX STRUCTURE _ READ 0 8' O.C. H-2 OR H-3 16'O.G TO CONIC, I/4-X3' LAG01s•a.Gro2x4sTTD (1)-1/4' X 2-1/P TAPOON 0 2NG ELi/1li' CUNT. PLUM. It O.C. TO CONC. SJANGLE W/ (1 o oIS,/HEx HEAD 8' O.C. NODS. 1) IF UNABLE TO NSTWLY COTSIRIT ANCHORS FROM HEADER CHN001 THEN NSTAIL 2'x2' CONTINUOUS ALUMBAW ANGLE AS SHOWN TO PROVIDE ADEQUATE RDNFORCEIMIT. CONC. WALL CONNECTION N.T.S. SELF-spcoG ALUMNUM ROLL ROOFING TAPE OR EQUAL (PER Pl/N) _ __ ____________ BSUATED PANE. INTERLOCKING PANEL CONNECTION N.T.S. (1)-,/4• TE(-SCREW. W/ 1' WASHER (AG BOLT SHALL BE A CON. 1' LONGER THAN PANE. THIMESS) O 8. O.C. (11'P.) PrDJ.! 18 AP-00 202 or s('l Ds (fO- SAMANEX E) U) 0 ' OE.CD. r' 202 E- (2)-l10 O V 0 Ed SMs/m HEAD U CORNER COLUMN N.T.S. r14 tq F 0 Go 202 202 a. NERD mPa _ _.41111 OFA._ 0 12' O.C. ELSEWHERE _-- - NOTES. 1) 1• FASCIA MAY BE BUILT UP BY LAGGING NEW 1' NFMBER TO ND W/ (2)-1/4' X 3-1/2• LAGS/TRUSS 0R RAPIER. 2• SUB -FASCIA BOW 1' FASCIA IS ALSO ACCEPTABLE, FASCIA CONNECTION N.T.S. PANEL !W. W/ 1' WASHER (LAG WIL I. LONGER THAN 0 8' GG (1YP.) AN e0- A .,IAA �� ''• >� Cp • C ARRYAM • •• 3%2 TEEM 1X2 SX2 o'd BEAM BUN 1/8' ION TIOCIO165 (I)-l10 x I-I/2' 1/8' MN Txx3NESS COWNN TWCK RECEMNO TNANNEL CLIP. ANTRE W/3 !IQ S.MS/HEL HEAD 011' CUP ANGLE W/3 110 ANCHORED TO BEUT W/ (5)-/I{ TE( SMS./IIEDL HEAD EA O.C. (ttP.) SMs./NFX HEAD EA SCREWS EA SIDE AND TO CUWLN M N/ FACE OP.) FACE (TYP.) (5)-!10 SM.S/IEM HEM arsE TIES DETAIL FOR COWMN SPACING GREATER THAN B'. -USE THIS DEIAI. FOR c0E0AN SPACING LESS THAN B'. CARRY BEAM TO COLUM `L' AEI Fa'f' COLUMN TO PANEL CONNECTION CONNECTION WT.S N.T.S. 4L T.E (j Wz ZW w ZZ�� �$ W� G� n° E YW�o$h'S5 n��.bb.Y �y�NNo a N 2 0 5z Q a z DATE' 03/03/2020 DSGN.' E. KENNNEDY DST: E XENNEDY CHKR E KENNEDY SCALE; N.T.S. DWG No. 3 of 4 SCREEN BEAM SCHEDULE WITH MANSARD ROOF MAX, BEAM SPAN BEAM COLUMN SPACOJG W UP TO V COLUMN HQGFT BEAM COLUMN SPACING W UP TO 10' COLUMN NQOT BERM COLUMN SPACING W UP TO IT COLUMN HE[C4T BEAM COLUMN SPACING W UP TO 16' COLUMN EL BEAM COLUMN SPACING W UP TO 20' COLUMN HEIGHT 5' 6' 7 w S' 6' 7' 8' S' 6' ]' B' S' 6' T e' S' 6' 1 7' 1B' 4LB 4m 4m 418 1 1 1 1 4LB SUB 5LB SUB SLB SUB 6W fiW 6UB 6LB 6LB 70 71LB 713 7LB 7LB am 38.3' 31.9' 26.& 22.0' BIB 35.0' 29.0' 22.0' 150 8W M.5' 25.5' BLB 27.6' 16.9' BLS 20.3' 9W 41.9' 35.7 29.1' 23.5' am 39.8' 92.4' 25.6' 18.9' 9IH VA 29.3' =21,4*22.51 9LB 31.9' 21.4' 8.0' 9LB 24.9' 7.5' 91811 55.9' 48.1' 02.5 3].8' 9LBH 53.5' 96.3' 40.4 35.3 9LBH 51.6' 44.1' 9L&1 47.9'90.0' 32.6' 25.6'9LN1 43.9' 35.3' 26.1' 16.3' LOW 62.6' 58.1' 54.8' 49.6' NOON 62.6' 59.4' 53.7 47.6' LOW 60.6' S6.9' 100 60,0' S4.1' 47.1' 43.5 IGLO 58.5' S0.5' 43.3' 36.W DEAN COLUMN SPACING W UP TO 8' COLUMN HEIGHT COLUMN SPACING Wl UP TO 19 COLUMN HELGM BEAM COLUMN SPACDJG W UP TO 12' COLUMN NEIC4IT COLUMN HQGHI' BEAM COLUMN SPACING W UP TO 20' COLUMN HEIGHT 5' 6' ]' B' 5' 6' 7' 8' S' 6' 7' 8' 7' 8'S'6' 7' 8' 4LB 4LB 4LB4LB 5WSIB 5WSLB6LB6LB 6LBGLB MPACIWV�l.16' RH7LB 7LB7LO 8LB 29.4'19BW 25.0' 11.9' 8W 20.0' 8LBam E 9L6 33.8'24.4' 13.8' 9LB 30.1' 16.8' 9LB 25.8' 10.S' 9LB 9LB 9WH 49.4' 41.4' 34.6' 28.0' 9lSH 46.9' 38.8' 31.tl 33.1' 918H 44.5' 35.6' 26.9' 17.5' 9LBH15.8' 9LEH 33.3' lOLB 59.4' S5.0 48.8' 49.tl lOIB 58,8' S3.4' 46.3 a0.3 101B 58.1' S1.3' 43.8' 36.9' SOW ..38.4' 29.9' 10LB 51.9' EAVE MEMBER SCHEDULE MAX. SPAN EAVE MEMBER DISTANCEFROM EAVE MEMBERTO CHAIR WITH FLAT ROOF RAIL BELOW EAVE MEMBER DISTANCE FROM EAVE MEMEERTO CHAIR WL BELOW WITH 3' MANSARD FAVE MEMBER DISTANCE FROM EAVE MEMBERTD CRAM WITH 4' MANSARD RAIL BELOW 6' 7' 8' 9' 6' 7' 8' 9' 6' 7 w 9' 2%2X0.040 8'-0" B'-0' 8'-0' 1T-e• 2%2X0.040 8'-0' 1 T-9' 1 1 2XZXO.040 1 8'-0" T-6' 6'-11' 6'-6- 2"XO.050 1 8'-0" 1 W-0' I 8'•0' 1 8'-0' 1 2X3X0.050 I B'-0' I 8'-0' 1 8'-0' 1 7-10 1 2X 0.050 8'-0" 9-0' 1 8--0' 7'-6- 2MG.060 I 8'-0' I T-0- I W-0' 1 8'-0' 1 2X3%0.060 1 8--D' I 8'-0' I 8'-0" 1 8'-0' 1 2X3X0.060 1 8--0" 1 9-0' 1 8'-0- I a'-0- COLUMN SCHEDULE WITH SCREEN FABRIC ROOF MAX. COLUMN HEIGHT MAXIMUM COLUMN IHEIGHT fRETURN WALL MAXIMUM COLUMN HEIGHT W UP TO MAX 25 ROOF SEAM I MAXIMUM COLUMN HEIGHT W UP TO MAX S0 ROOF BEAM WLUMN COLUMN COLUMN 4-0" 6'-0" 7-0" B'•0" S-0" 6'-0" T-0" 8'-0" 5'-0" 6'-0" T-0" e'-0" 4LB 9.2' 8.5 7.7 4LB 8.7' 7.8 4LB SUB 12.0 SILT SUB 11.5 10.4' 9.4' 8.6' SE 10.6 9.4 8.4' 7.G 13.3' 10.5' 6LB 12.T 114' . . 10.4' 9.5' 6LB 11.6 30.4' 9.2 8.7 7L3 15.7 11.8' 7LB 14.5 . 130' 12' 0 11.0' 7LB 13.5 11.9 10.7' 9.7 8LB 20.0' M20.U20.U 18.1' SUB 20.0' 200 .' 187 . 17.4 8LB 20.0' 19.4 17.7 16.3' SUB 20.0' 19.3' 9UB 20.0' 200 .' 19T . 18.3' 9B 20.0' 20.0' 18.6' 17.1' 9B 2O.0' 20.0' 9LEH 20.0' 00 2.' 00'6B 2. 20.0' 9IBH 2O.0' 20.0' 20.0' 20.0' WAY 20.0' ICLB 20.D M.0' 2 0.0'10LB 20.0' IOLB CHAIR RAIL SCHEDULE MAX. SPAN RAIL MEMBER LENGTH OF VERTICAL LOAD ON CFATR RAIL 4' S' 6' 7' 1 8' S 2X2X0.040 8'-0° 7'-D' 6'-6" 6'-0" 5-6" 2X3XO.050 5-11" 8'-10" 8'-0" T-6" 1 T-0" I 6'-B" 2X3XO.06O 11'-0" 1 11'-0" I 10'-S" 1 9'-9" 1 9'-2" 1 8'-8" 2X4XO.05o 11'-0" 1 10-8" 1 7-8" 1 8`11" 1 V-4° 1 7-11" BEAM PROPERTIES BEAM TYPE SIZE THIIXNESS b INCHES 4 INCHES LI INCHES 12 INCHES 4LB LAP BEAM 2.0 4.0 0.100 0.096 5U3 LAP BEAM 2.0 5.0 OA16 0.050 GILD LAP BEAM 2.0 6.0 0.120 0.050 7LB LAP BEAM 2.0 7.0 0.120 0.055 SLB LAP BEAM zo 8.0 0.224 0.072 9LB LAP BEAM 2.0 9.0 0.ZM 0.072 9LBH LAP BEAM zo 9.0 0.306 0.082 10W LAP BEAM 20 10.0 0.389 0.092 DBLSOW LAP BEAM 2.0 10.0 0.389 0.092 SCREEN BEAM SCHEDULE W/ FLAT ROOF (MAX. BEAM SPAN) BEAM COLUMN SPACING S' 6' 7' 1 8' 4LB 1S.5' 14.3' 13.0' 10.0' SUS 17.5' 15.4' 12.5 6LB 19.1' 16.8' 13.4' 7LB 22.4' 20.0' 16.N 8LB 40.1' 36.2' 140.F 30.8' 9LB 42.5 38.4' 32.5 9LBH 46.5 43.5' 39.0 IOLE. 52.5' 495' 45.5 SCHEDULES AND NOTES N.T.S. swEmaE DESCH Bea: 1) THESE PLANS CONFORM M THE REOu0iE11EM5 OF THE FLORIDA BINDOIG CODE 6M DIMON (2017). THE ALLUNlM DESIGN MANUAL (CUMff EDITION). AND ASCE 7-10. 2) WAIDIUM SPANS SPECIFIED ARE BASED ON DESIGN PRESSURES FROM FBC TABLE 2002.4 WHIR BA9C WND SPEED - 150 MPH. DFOSURE D. RISK CATEM I, AND 20 X 20 WF511 WRH > 602 SUM OPENNfS, 3) DESIGN PMSUFES ARE 9 PSF ROOF + 31 PSF WALL COMM LOAD AND 309 LE, POINT LOAD NON -COMBINED LOAD. 4) LOADS ARE APPUED 9MIATANEOUSLY TO WALL & ROOF. 5) DESIGN BASED ON 6005.75 ALUMINUM ALLOY. 8) OEM WEDS L/60 DEFLECTION RMUWEMFNIS. 7) IBTM INTERPOLATION 6 ALLOWED ffiWEFN COLUMN SPACING 0.1 .\ Ni ., % lee L Z : m W:Z � \l'.jl :c i rr J Q J Lu E a 5 ZW E zwtjl8 Z Lwu 0 X z WOR 0.5 v�8<:Ej , % tR ay:j ' DATE 03/03/2020 DSM: E KENNEDY DRWN: E KENNEDY CHXD: E. KENNEDY SCALE: N.T.S. DWG N, 4 01 4