HomeMy WebLinkAboutTANK SPECS - 6-5-20aft -
Quality Steel Corporation AG f UG Propane Tanks
LEC NEE
1450 wg. AND LAP
APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS
WATER
CAPACITY
DIAMETER
(OD)
HEAD
TYPE
OVERALL
LENGTH
OVERALL
HEIGHT
LEG*
WIDTH
LEG**
SPACING
WEIGHT
(ft.)
**QUANTITY
FULL LOAD
PER STACK
*120 wg.
24"
Ellip.
51-8"
3'
1'41/2"
2'-101/2u
or 3 -11
260
109 196
16 112
*250 wg.
30"
Hemi.
7'-10"
31-8"
1-5"
4'-11"
480
S4
9
*320 wg.
30"
Hemi.
9'-7"
3'-8"
1'-5"
5'
620
45
9
500 wg.
371/2"
Hemi.
20'
4'-2"
1'-8"
5'
950
37130
8 1 6
1000 wg.
41"
Hemi.
16'
4'-5"
1'-8"
10'-1"
11800
17 j 15
6 1 5
1450 wg.
461/2"
Ellip.
17'-4"
4'-11"
1'-9"
11'40
2,650
12
4
1990 wg.
461/2"
Ellip.
23'-11"
4'-11"
1'-9"
16'
3,520
8
4
Iftenslons and specHkadom shown are approximate. hkdlWdual vessels may vary.
' Leg Waft +/- 2 % Leg widths and sparing may vary based an mfg. (aatlon. Check with your salesperson for detal6p. 120, 250, 320 wg. standard tanks
- no hales In legs (one center hole an requestL SW and 1WD wg, standard tanks - 2 holes W an center. 1450 wg. and up as shmn above.
'• Full load and stack quantities Yy by shipping location. Check with your salesperson for details.
General Saedflcatlons
- Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vlll, Division 1.
Complies with NFPA 58.
- Rated at 250 prig from -20" F to 125" F. All vessels registered with National Board.
- Two service options available:
Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish
or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite
AG/UG dome.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome.
- All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated June 30, 2015
�, . .. h•• ...;
JIM
vUs sue
*14�
low'i
• , w� • . 9Nt1f�0
_ •ar!rr�1t xv
• J .
• r 1
' - PROPANE CONSTRUCTION NOTES
1. All pipe and fittings above ground and inside building shalt be
SCH..40 Galvanized. ASTM A120 or AGA approved_corrugafed
stainless steel •(C.S.S.T.) •pipe. ,
2. All polypipe and fiitf hgs shall be ASTMI D251.3 or ASTM! D2517
and shaft be butted -outside underground at a depth of 18" with
warning tape and tracer wire.
3. All pipe and meter locations are approximate and subject to
change.-
.4. Ali polypipe shall be joined by heat fusion or approved mechanical .
couplings.
• 5. Ail'galvanlzed plpe shall be threaded.
5: Alt pipe shalt l;e pt essurs tested to 20 PSI for a period of 24
hours.
' UNDERGROUND TANK INSTALLATIOr
• 2" to G•
• DOWNGRADED AWAY
• FROM DOME ._._.. a.� �... •„��
mt
j lb
I ANODE CABLE • • �'•� -� ' ''•` •
SACRIFICIAL ANODE :...��• • , • • _ :• • • ,
(MAGNESIUM BAGS �. •� •
REGULATOR
•
•
SMUT GAS OFF AT
��
ODU D-1 VA16VE
•x
• -
Me v E G AD E
' ..:..
- O
- - .
WARY trG TAPE -
:
•
GRADE/CONCfETB SLEEVE
i
• o.100
.a
.•..f O0 I •;'Ov ••
t/ •. •o O.0.1 dd
•
•. .•w. •• p,•
40
�t1•
4 o..
is .,••• .•• .•• o• o o
..� ..
a°
a •°
• vNoeno vu��o
.aAi COutM n - :SERVICE LINE
•
,
TRACE NIRB