HomeMy WebLinkAboutNOA; GAF Ruberoid Modified Bitumen Roof System for Wood DecksMIAMI•DADE
DEPARTMENT OF I
BOARD AND CODE
REVIEWED FOR
CODE COMPLIANCE
NOTICE OF ACCEPTANCE
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
9
FILE COPY
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Sheet, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
www.miamidade.gov/economv
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within
their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade
County Product Control Section that this product or material fails to meet the requirements of the
applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Ruberoid® Modified Bitumen Roof System for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at thejob site at the request of the Building Official.
This NOA renews and revises NOA No. 15-1020.01 and consists of pages I through 67.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 18-0919.12
MwMi-DADEcourm Expiration Date: 11/06/23
Approval Date: 11/01/18
Page I of 67
r
ROOFING SYSTEM APPROVAL
Category Roofing '
Sub -Category: Modified Bitumen
Material: APP/SBS
Deck Type: Wood
Maximum Design Pressure: -105 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
GAFGLAS® Ply 4
39.37"
ASTM D2178
Smooth surfaced asphaltic ply sheet
(I meter) Wide
reinforced with fiberglass mat.
Tri-Ply® Ply 4 Ply Sheet
39.37"
ASTM D2178
Smooth surfaced asphaltic ply sheet
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS®
39.37"
ASTM D2178
Smooth surfaced asphaltic ply sheet
F1exPly' 6
(1 meter) Wide
reinforced with fiberglass mat.
GAFGLAS® #75 Base Sheet
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
(I meter) Wide
reinforced with fiberglass mat.
Tri-Ply® #75 Base Sheet
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
(I meter) Wide
reinforced with fiberglass mat.
GAFGLAS® #80 Ultima'" Base
39.37"
ASTM D4601
Smooth asphaltic base or base/ply sheet
Sheet
(I meter) Wide
reinforced with fiberglass mat.
GAFGLAS® Stratavent®
39.37"
ASTM D4891
Smooth surfaced asphaltic perforated
Perforated Venting Base Sheet
(1 meter) Wide
venting base sheet reinforced with
fiberglass mat.
GAFGLAS® Stratavent®
39.37"
ASTM D4897
Smooth surfaced asphaltic nailable venting
Nailable Venting Base Sheet
(1 meter) Wide
base sheet reinforced with fiberglass mat.
Bottom side surfaced with granules.
Ruberoid® HW 25 Smooth
39.37"
ASTM D6163
Smooth surfaced torch applied SBS base
(1 meter) Wide
or ply sheet reinforced with a fiberglass
mat.
Ruberoid® HW Smooth
39.37"
ASTM D6164
Smooth surfaced torch applied SBS base
(1 meter) Wide
or ply sheet reinforced with a polyester
mat.
Ruberoid® HW Granule
39.37"
ASTM D6164
Granule surfaced torch applied SBS cap
(I meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® HW Granule FR
39.37"
ASTM D6164
Fire retardant granule surfaced heat -
(I meter) Wide
welded SBS cap sheet reinforced with a
polyester mat.
Ruberoid® HW Plus Granule
39.37"
ASTM D6164
Granule surfaced torch applied SBS cap
(I meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® HW Plus Granule
39.37"
ASTM D6164
Fire retardant granule surfaced torch
FR
(1 meter) Wide
applied SBS cap sheet reinforced with a
polyester mat.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 2 of 67
Test
Product
Product
Dimensions
Specification
Description
Ruberoid® EnergyCap' HW
I meter
ASTM D6164
Fire retardant granule surfaced heat -
Plus Granule FR
(39.37") Wide
welded SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT® EnergyCote''
Elastomeric Coating.
Ruberoid® Torch Smooth
39.37"
ASTM D6222
Smooth surfaced torch applied APP base
(1 meter) Wide
or ply sheet reinforced with a polyester
mat.
Tri-Ply® APP Smooth
39.37"
ASTM D6222
Smooth surfaced torch applied APP cap,
Membrane
(1 meter) Wide
base or ply sheet reinforced with a
polyester mat.
Ruberoid® Torch Granule
39.37"
ASTM D6222
Granule surfaced torch applied APP cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Tri-Ply® APP Granule Cap
39.37"
ASTM D6222
Granule surfaced torch applied APP cap
Sheet
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® Torch Plus Granule
39.37"
ASTM D6222
Fire retardant granule surfaced torch
FR
(1 meter) Wide
applied APP cap sheet reinforced with a
polyester mat.
Ruberoid® EnergyCap'
39.37"
ASTM D6222
Fire retardant granule surfaced torch
Torch Plus Granule FR
(1 meter) Wide
applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT® EnergyCote'
Elastomeric Coating.
Ruberoid® EnergyCar
39.37"
ASTM D6222
Fire retardant granule surfaced torch
Torch Granule FR
(1 meter) Wide
applied APP cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT® EnergyCote
Elastomeric Coating.
Ruberoid® 20 Smooth
39.37"
ASTM D6163
SBS polymer -modified asphalt base or ply
(I meter) Wide
sheet reinforced with a fiberglass mat.
Ruberoid® 30 Granule
39.37"
ASTM D6163
Granule surfaced mop applied SBS cap
(I meter) Wide
sheet reinforced with a fiberglass mat.
Ruberoid® 30 Granule FR
39.37"
ASTM D6163
Fire retardant granule surfaced mop
(1 meter) Wide
applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoid® 30 Plus Granule FR
39.37"
ASTM D6163
Fire retardant granule surfaced mop
(I meter) Wide
applied SBS cap sheet reinforced with
fiberglass mat.
Ruberoid® Mop Granule
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Tri-Ply® SBS Granule Cap
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
Sheet
(1 meter) Wide
sheet reinforced with a polyester mat.
Intec Flex PRF
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(I meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® Mop Smooth
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base
(1 meter) Wide
sheet reinforced with a polyester mat.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 3 of 67
Test
Product
Product
Dimensions
Specification
Description
Ruberoid® Mop Smooth 1.5
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® Mop Plus Smooth
39.37"
ASTM D6164
Smooth surfaced mop applied SBS base or
(1 meter) Wide
ply sheet reinforced with a polyester mat.
Ruberoid® Mop Plus Granule
39.37"
ASTM D6164
Granule surfaced mop applied SBS cap
(1 meter) Wide
sheet reinforced with a polyester mat.
Ruberoid® Mop Plus Granule
39.37"
ASTM D6164
Fire retardant granule surfaced mop
FR
(1 meter) Wide
applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid® EnergyCap' Mop
39.37"
ASTM D6164
Fire retardant granule surfaced mop
Plus Granule FR
(I meter) Wide
applied SBS cap sheet reinforced with a
polyester mat. Cap sheet is factory coated
with TOPCOAT® EnergyCote'
Elastomeric Coating.
Ruberoid® Mop Granule FR
39.37"
ASTM D6164
Fire retardant granule surfaced mop
(I meter) Wide
applied SBS cap sheet reinforced with a
polyester mat.
Ruberoid® EnergyCap' 30
39.37"
ASTM D6163
Fire retardant granule surfaced mop
Granule FR
(1 meter) Wide
applied SBS cap sheet reinforced with a
fiberglass mat. Cap sheet is factory coated
with TOPCOAT® EnergyCote'"
Elastomeric Coating.
GAFGLAS® Mineral -Surfaced
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Cap Sheet
(1 meter) Wide
reinforced with fiberglass mat.
Tri-Ply® BUR Granule Cap
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Sheet
(1 meter) wide
reinforced with a fiberglass mat.
GAFGLAS®EnergyCap'
39.37"
ASTM D3909
Granule surfaced asphaltic cap sheet
Mineral -Surfaced Cap Sheet
(I meter) Wide
reinforced with fiberglass mat. Cap sheet
is factory coated with TOPCOAT
EnergyCote' Elastomeric Coating.
TOPCOAT® Membrane
1, 5 or 55 gallons
ASTM D6083
Water based elastomeric coating.
United Coatings' Roof Mate
1, 5 or 55
ASTM D6083
Water -based elastomeric coating
TCM Coating
Gallons
TOPCOAT®
5 or 55 gallons
ASTM D6083
Solvent based thermoplastic rubber sealant
Surface Seal SB
designed to protect and restore aged roof
surfaces and to increase roof reflectivity.
United Coatings' Surface Seal
5 or 55 Gallons
ASTM D6083
Solvent -based thermoplastic rubber
SB Roof Coating
sealant designed to protect and restore
aged roof surfaces and to increase roof
reflectivity.
TOPCOAT' MB Plus
5 or 55 gallons
Proprietary
Water based, low VOC primer used to
block asphalt bleed -through.
United Coatings' Roof Mate
5 or 55 Gallons
Proprietary
Water based, low VOC primer designed to
MB Plus Coating
block asphalt bleed -through.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 4 of 67
Test
Product
Product
Dimensions
Specification
Description
FireOut" Fire Barrier Coating
5 or 55 gallons
Proprietary
Low VOC, water -based fire barrier
coating.
Flex Seal'
1, 5 gallons
TAS 139
Solvent -based elastomeric sealant.
or 1 qt. tube
VersaShield® Fire -Resistant
12" x 100' rolls
ASTM D226
Non -asphaltic fiberglass -based
Roof Deck Protection
underlayment and /or fire barrier.
VersaShield® Solo' Fire-
42" roll wide,
ASTM D146,
Non -asphaltic, fire resistant fiberglass
Resistant Slip Sheet
100 ft.
D828, D4869,
underlayment
D6757
Matrix' 102 SBS Membrane
3, 5 or 55 gallons
ASTM D3019
Fiber reinforced rubberized cold -applied
Adhesive
adhesive for modified bitumen roof
systems.
APPROVED INSULATIONS:
Product Name
EnergyGuard'' Polyiso Insulation
EnergyGuard'
Tapered Polyiso Insulation
EnergyGuard'
RA Polyiso Insulation
EnergyGuard'
RH Polyiso Insulation
EnergyGuard'"
RH Tapered Polyiso
Insulation
EnergyGuard' RN Polyiso Insulation
EnergyGuard' Perlite Recover Board
EnergyGuard' Perlite Roof Insulation
Table 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Perlite recover board
Perlite insulation board
EnergyGuard' RA Composite Polyiso Polyisocyanurate foam insulation
Insulation with high density fiberboard or
permalite
Structodek® High Density Fiberboard Roof High density fiberboard
Insulation
SECUROCK® Gypsum -Fiber Roof Board Gypsum board
SECUROCK® Glass -Mat Roof Board Gypsum board
DensDeck® Roof Board Gypsum board
DensDeck® Prime Roof Board Gypsum board
Manufacturer
(With Current NOA)
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
Blue Ridge Fiberboard, Inc.
United States Gypsum Corp.
United States Gypsum Corp.
Georgia-Pacific
Georgia-Pacific
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 5 of 67
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Number Name
Description
1. Drill -Tee' 412 Fastener
Phillips head, modified
buttress thread, pinch
point, carbon steel fastener
for use in steel or wood
decks. With CR-10
coating. Available with a
pinch point or drill point.
2. Drill -Tee' #14 Fastener
Truss head, self -drilling,
pinch point, high thread
fastener for use in steel,
wood or concrete decks.
3. Drill-Tec' XHD Fastener
Truss head, self -drilling,
pinch point, high thread
fastener for use in wood or
steel decks. Carbon steel
extra heavy duty fastener
used in steel decks.
4. Drill-Tec' 3" Steel Plate
Round Galvalume® steel
stress plate with
reinforcing ribs and
recessed for use with Drill -
Tee' fasteners.
5. Drill-Tec' 3" Standard
Galvalume® coated steel
Steel Plate
stress plate for use with
approved Drill-Tec'
fasteners.
6. Drill -Tee' ASAP 3S
Drill-Tec' #12 fastener
with Drill-Tec' 3"
Standard Steel Plate.
7. Drill-Tec' AccuTrac®Flat A2-SS aluminized steel
Plate plate for use with Drill -
Tee' fasteners.
8. Drill-Tec' AccuTrac® Galvalume® steel plate
Recessed Plate with recess for use with
Drill-Tec' fasteners.
9. Drill-Tec' 3 in. Ribbed Round Galvalume®plated
Galvalume Plate (Flat) steel stress plate with
reinforcing ribs for use
with Drill -Tee' fasteners.
Dimensions
#12x8"
Max. Length
#3 Phillips
head.
#14 x 16"
Max. Length
#3 Phillips
head.
#15 x 16"
Max. Length
#3 Phillips
head.
3" Round
3" Round
#12x8"
Max. Length
#3 Phillips
head with 3"
Round plate
3" square;
.017" thick
3" square;
.017" thick.
3" Round
Manufacturer
(With Current NOA)
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 6 of 67
EVIDENCE SUBMITTED:
Test Agencv Test Identifier Description Date
FM Approvals
3001276
FMRC 4470
01/28/99
3010215
FMRC 4470
03/01/01
3029832
FMRC 4470
05/11/07
3036980
FMRC 4470
08/14/09
3034312
FMRC 4470
04/09/09
3040738
FMRC 4470
05/18/12
3042887
FMRC 4470
11/14/11
3046081
FMRC 4470
02/13/13
3043633
FMRC 4470
01/20/12
1B9A8.AM
FMRC 4470
09/04/97
3B9Q1.AM
FMRC 4470
01/08/08
3D4Q2.AM
FMRC 4470
04/30/97
OD1A8.AM
FMRC 4470
04/01/98
797-03221-267
FMRC 4470
09/24/07
797-10228-267
FMRC 4470
01/15/15
797-04694-267
FMRC 4470
06/17/09
797-03825-267
FMRC 4470
07/14/08
RR203450
FMRC 4470
12/04/15
FM Letter
FMRC 4470
04/11/13
FM Letter
FMRC 4470
09/15/15
UL LLC
RI306
UL 790
08/21/18
IRT-ARCON Inc.
02-005
TAS 114-J
07/19/04
02-014
TAS 114-J
04/08/02
Trinity I ERD
C8500SC.11.07
ASTM D6862
11/30/07
G30250.02.10-2
ASTM D6222
11/11/10
G30250.02.10-3-R2
ASTM D3909
06/03/15
G31360.03.10
ASTM D6164
03/31/10
G32520.06.11
ASTM D1876
06/28/11
G33470.01.11
ASTM D6164
01/13/11
G34140.04.11-2
ASTM D6163
04/25/11
G34140.04.11-4-R2
ASTM D4601
6/4/2015
G34140.04.11-5-R3
ASTM D4897
6/4/2015
G36780.07.11-RI
TAS 114-J
07/18/11
G40620.07.12-2
ASTM D6222
07/17/12
G40630.01.14-I
ASTM D6163
01/06/14
G40630.01.14-2A
ASTM D5147
01/07/14
G40630.01.14-2A-1-RI
ASTM D6164
04/10/14
G40630.01.14-213-RI
ASTM D6164
01/16/15
G40630.01.14-2C
ASTM D6164
01/07/14
G40630.03.14
ASTM D5147
03/06/14
G43190.03.14-1
ASTM D5147
03/06/14
G43190.03.14-2
ASTM D5147
03/06/14
G43190.05.14-RI
ASTM D5147
05/20/14
G43610.01.14
ASTM D5147
01/22/14
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 7 of 67
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency
Test Identifier
Description
Date
Trinity ERD
G43190.11.13-1
ASTM D6222
11/15/13
G46160.02.15
ASTM D6163
02/12/15
G46160.02.15-2D-1
ASTM D6163
02/09/16
G46160.03.15
ASTM D6163
03/11/15
G46160.09.14-2A
ASTM D5147
09/09/14
G46160.09.14-3A
ASTM D6164
09/09/14
G46160.09.14-313
ASTM D6164
09/09/14
G46160.09.14-3C
ASTM D5147
09/09/14
G46160.12.14-3E
ASTM D6164
12/29/14
G6850.08.08
ASTM D6163
08/01/08
G6850.08.08-R1
ASTM D6164
04/14/11
G6850.10.08
ASTM D6222
10/06/08
G6850.11.08
ASTM D6222
02/17/09
SC6870.08.14-RI
ASTM D3909
09/04/14
PRI Construction Materials
GAF-122-02-01
TAS 139
05/07/06
Technologies, LLC
GAF-245-02-01
ASTM D6083
06/10/10
GAF-276-02-0 I Rev
ASTME2178
01/04/11
ASTM D6083
GAF-306-02-01
ASTM E96
07/07/11
GAF-314-02-01
ASTM D2178
08/23/11
GAF-315-02-01
ASTM D2178
08/23/11
GAF-369-02-01
ASTM C1289
10/22/12
GAF434-02-03
TAS 114-J
09/06/13
GAF434-02-04
TAS 114-J
09/06/13
GAF464-02-01
ASTM C1289
02/06/14
GAF-498-02-01
ASTM D6083
09/16/16
GAF-499-02-01
ASTM D6083
03/12/14
GAF-500-02-01
ASTM D6083
03/12/14
GAF-559-02-01
TAS 117(B)
09/30/14
GAF-559-02-04
ASTM D1876
10/01/14
GAF-559-02-05
ASTM D1876
10/15/14
GAF-559-02-06
TAS 114(I)
10/02/14
GAF-559-02-07
ASTM D903
10/02/14
GAF-559-02-08
ASTM D903
10/02/14
GAF-559-02-09
ASTM D903
10/02/14
GAF-559-02-11
TAS 114-J
10/14/14
GAF-559-02-12
TAS 114-J
10/14/14
GAF-559-02-13
TAS 114-J
10/15/14
GAF-559-02-14
TAS 114-J
10/15/14
GAF-559-02-15
TAS 114-J
10/15/14
GAF-559-02-16
TAS 114-J
10/15/14
GAF-559-02-18
TAS 114-J
10/15/14
GAF-559-02-19
TAS 114-J
04/16/15
Dynatech Engineering Corporation
#4482.02.95-1
TAS 114-C
09/01/95
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 8 of 67
APPROVED ASSEMBLIES
Membrane Type: SBS
Deck Type H: Wood, Insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type A(1):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection
(optional)
or VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting
Base Sheet, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25
Smooth base sheet mechanically fastened to deck as described below.
Fastening
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® F1exPly'" 6,
Option #1:
GAFGLAS® #75 Base Sheet, Tri-Ply® 475 Base Sheet or any of above anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the
field.
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly' 6,
Option #2:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above anchor
sheets attached to deck with Drill -Tee' #12 Fastener, Drill-Tec' #14 Fastener or
Drill -Tee' XHD Fastener and Drill-Tec' 3" Steel Plate, Drill-Tec'' AccuTrac®
Flat Plate or Drill-Tec' AccuTrac® Recessed Plate installed 12" o.c. in 3 rows.
One row is in the 2" side lap. The other rows are equally spaced approximately
12.5" o.c, in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening
GAFGLAS® FlexPly' 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or
Option #3:
any of above anchor sheets attached to deck with approved annular ring shank
nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two
rows 9" o.c. in the field.
(Maximum Design Pressure —52.5 psf. See General Limitation #7)
Fastening GAFGLAS® 475 Base Sheet, Tri-Ply® #75 Base Sheet or any of above anchor
Option #4: sheets attached to deck with Drill-Tec' 412 Fastener, Drill-Tec' #14 Fastener or
Drill-Tec' XHD Fastener and Drill-Tec'" 3" Steel Plate, Drill-Tec' AccuTrac®
Flat Plate or Drill-Tec'" AccuTrac® Recessed Plate installed 12" o.c. in 4 rows.
One row is in the 2" side lap. The other rows are equally spaced approximately 9"
o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening GAFGLAS® #80 Ultima' Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop
Option #5: Smooth base sheet attached to deck approved annular ring shank nails and 3"
inverted Drill-Tec' 3" Steel Plate at a fastener spacing of 9" o.c. at the 4" lap
staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psf. See General Limitation #7)
NOA No.: 18-0919.12
11LAMMAnEcourrrr Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 9 of 67
Fastening GAFGLASe 475 Base Sheet, Tri-Ply® #75 Base Sheet or any of above anchor
Option #6: sheets attached to deck with Drill -Tee' #12 Fastener, Drill -Tee' #14 Fastener or
Drill -Tee' XHD Fastener and Drill-Tec'' 3" Steel Plate, Drill -Tee' AccuTrace
Flat Plate or Drill-Tec'' AccuTrace Recessed Plate installed 8" o.c. in 4 rows.
One row is in the 2" side lap. The other rows are equally spaced approximately 9"
o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard'°' Polyiso RA Insulation,
EnergyGuard' Polyiso RN Insulation, EnergyGuard' RA Composite Polyiso Insulation
Minimum 1" thick N/A N/A
Structodek® High Density Fiber Board, EnergyGuard'' Perlite Recover Board
Minimum'/P thick N/A N/A
EnergyGuard' Perlite Roof Insulation
Minimum %11 thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the ENT range and at a rate of 20-40 lbs./100 ff. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavent®
Perforated Venting Base Sheet laid dry or a layer of EnergyGuard'" Perlite Roof Insulation or
wood fiber overlay board on all polyisocyanurate applications.
Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base
Sheet, GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Ply 4, Tri-Ply® Ply 4
Ply Sheet GAFGLAS® FlexPly'" 6, Ruberoide Mop Smooth, Ruberoide Mop
Smooth 1.5, Ruberoide Mop Plus Smooth, Ruberoide 20 Smooth, Ruberoide HW
Smooth or Ruberoide HW 25 Smooth directly over the top layer of insulation.
Adhere with any approved mopping asphalt applied within the EVT range and at a
rate of 20-40 lbs./sq. (See General Limitation #4).
OR
GAFGLAS® Stratavent® Perforated Venting Base Sheet loose -laid dry.
Ply Sheet: (Optional, required over GAFGLAS® Stratavent® Perforated Venting Base Sheet
loose -laid dry)One or more plies GAFGLAS® Ply 4, GAFGLASe F1exPly'" 6,
GAFGLASe #80 Ultima' Base Sheet, Ruberoide Mop Smooth, Ruberoide Mop
Smooth 1.5, Ruberoide Mop Plus Smooth, Ruberoide 20 Smooth adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
NOA No.: 18-0919.12
MIAMMADE COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 10 of 67
Membrane: One or more plies of Ruberoid® 20 Smooth, Ruberoid® 30 Granule, Ruberoid'
EnergyCap'' 30 Granule FR, Ruberoid' 30 Granule FR, Ruberoid' 30 Plus
Granule FR, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid'
Mop Plus Smooth, Ruberoid' Mop Granule FR, Ruberoid' Mop Granule, Tri-Ply'
SBS Granule Cap Sheet, Intec Flex PRF , Ruberoid' Mop Plus Granule,
Ruberoid' Mop Plus Granule FR fully adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet
or GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings'' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure:
APPROVED
See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 11 of 67
Membrane Type: APP/SBS Heat Weld
Deck Type 1I: Wood, Insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type A(2): Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt.
All General and System Limitations shall apply.
Fire Barrier: FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection,
(optional) VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck' Roof Board,
SECUROCK® Gypsum -Fiber Roof Board, or SECUROCK® Glass -Mat Roof
Board.
Anchor sheet: GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting
Base Sheet, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25
Smooth base sheet mechanically fastened to deck as described below;
Fastening GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® FlexPly'" 6, GAFGLAS® #75
Option #1: Base Sheet, Tri-Ply® #75 Base Sheet or any of above anchor sheets attached to
deck with approved annular ring shank nails and tin caps at a fastener spacing of
9" o.c. at the lap staggered and in two rows 18" o.c. in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® F1exPly� 6,
Option #2: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above anchor
sheets attached to deck with Drill-Tec' #12 Fastener or Drill-Tec' 414 Fastener
and Drill-Tec' 3" Steel Plate, Drill-Tec' AccuTrac® Flat Plate or Drill-Tec'
AccuTrac® Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 12.5" o.c. in the field of the
sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening GAFGLAS® F1exPly'" 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet,
Option #3: or any of above anchor sheets attached to deck with approved annular ring shank
nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two
rows 9" o.c. in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure —52.5 psf. See General Limitation #7)
Fastening GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above anchor
Option #4: sheets attached to deck with Drill-Tec' #12 Fastener or Drill-Tec"" #14 Fastener
and Drill-Tec" 3" Steel Plate, Drill -Tee' AccuTrac® Flat Plate or Drill-Tec'
AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
NOA No.: 18-0919.12
nwMFDADe COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 12 of 67
Fastening GAFGLAS® #80 Ultima' Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop
Option #5: Smooth base sheet attached to deck approved annular ring shank nails and 3"
inverted Drill -Ted' 3" Steel Plate at a fastener spacing of 9" o.c. at the 4" lap
staggered in two rows 9" in the field.
Not for use with DensDeck and SECUROCK Fire Barrier
(Maximum Design Pressure —60 psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet, Tri-Ply #75 Base Sheet or any of above anchor
Fastening sheets attached to deck with Drill -Ted'" #12 Fastener or Drill-Tec"" #14 Fastener
Option #6: and Drill -Ted" 3" Steel Plate, Drill-Tec'' AccuTrac® Flat Plate or Drill -Ted'
AccuTrac® Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure - 45 psf. See General Limitation #9)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' RA Polyiso Insulation, EnergyGuard' RA Composite Polyiso Insulation
Minimum 1" thick N/A N/A
Structodek® High Density Fiber Board, EnergyGuard' Perlite Recover Board
Minimum''/z" thick N/A N/A
EnergyGuaril"" Perlite Roof Insulation
Minimum'/4" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Strataven&
Perforated Venting Base Sheet laid dry or a layer of EnergyGuard' Perlite Roof Insulation or
wood fiber overlay board on all polyisocyanurate applications.
Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet,
GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Ply 4, GAFGLAS® FlexPly""
6, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid Mop Plus
Smooth, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25
Smooth directly over the top layer of insulation. Adhere with any approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
(See General Limitation #4).
OR
GAFGLAS® Stratavent® Perforated Venting Base Sheet loose -laid dry.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 13 of 67
Ply Sheet: (Optional except over Ruberoid® Mop Smooth, Ruberoid® 20 Smooth, Ruberoid®
HW Smooth or Ruberoid® HW 25 Smooth or GAFGLAS® Stratavent® Perforated
Venting Base Sheet loose -laid dry) One or more plies GAFGLAS® Ply 4, Tri-Ply®
Ply 4 Ply Sheet, GAFGLAS® F1exPly' 6 or GAFGLAS® #80 Ultima' Base Sheet
adhered in a full mopping of approved asphalt applied within the EVT range and at
a rate of 2040 lbs./sq. or Ruberoid® Torch Smooth or Tri-Ply® APP Smooth
Membrane torch applied according to manufacturer's application instructions
(Ruberoid® Torch Smooth or Tri-Ply® APP Smooth Membrane not to be used over
GAFGLAS® Stratavent® Perforated Venting Base Sheet).
Membrane: One ply of Ruberoid® Torch Smooth, Tri-Ply® APP Smooth Membrane, Ruberoid®
Torch Granule, Tri-Ply® APP Granule Cap Sheet, Ruberoid® EnergyCap" Torch
Granule FR, , Ruberoid® EnergyCap' Torch Plus Granule FR or Ruberoid® Torch
Plus Granule FR torch applied according to manufacturer's application
instructions.
Or
One or more plies of Ruberoid® HW Plus Granule, Ruberoid® HW Plus Granule
FR, Ruberoid® HW Granule FR, Ruberoid® EnergyCar HW Plus Granule FR,
Ruberoid® HW Granule, Ruberoid® HW Smooth and Ruberoid® HW 25 Smooth
applied according to manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® Mineral Surfaced Cap Sheet
or GAFGLAS® EnergyCapn' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3. TOPCOAT® Surface Seal SB or United Coatings'' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
Maximum
Design Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 14 of 67
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Description: Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier: FireOuf" Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional) VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8
Option #1: in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side
laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8
Option #2: in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side
laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening Drill-Tec' #14 Fasteners and Drill-Tec'-3 in. Standard Steel Plates, Drill-Tec'
Option #3: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the
field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec"'
Option #4: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in, o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the
field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee
Option #5: AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —75 psf, See General Limitation #7)
One or more of any of the following.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard'" Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuard'Ultra Polyiso Insulation, EnergyGuard'"RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
MIAMMADE COUNTY
0 , Expiration Date: 11/06/23
Approval Date: I1/01/18
Page 15 of 67
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ftz
EnergyGuard'°' Perlite Roof Insulation
Minimum '/d'thick N/A N/A
Structodek® High Density Fiber Board Roof Insulation
Minimum'/2" thick N/A N/A
SECUROCKI Gypsum -Fiber Roof Board, DensDeck® Prime
Minimum''/" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet or Tri-Ply® #75 Base Sheet.
Adhered with any approved mopping asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq. (See General Limitation #4).
Ply Sheet: Ruberoid® 20 Smooth adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.
Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid® Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap' Mop Plus
Granule FR, Ruberoid® EnergyCap"' 30 Granule FR, GAFGLAS® Mineral -
Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS®
EnergyCap' Mineral -Surfaced Cap Sheet adhered with any approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. TOPCOAT'® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT'® Membrane or United Coatings'" Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum
Design Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 16 of 67
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Description: Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(4):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. I-5/8
Option #1:
in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side
laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure -45 psj, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8
Option #2:
in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side
laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #3:
AccuTrac® Flat Plates or Drill -Tee'' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the
field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec'' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #4:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the
field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —75 psf, See General Limitation #7)
One or more of the any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuard' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 17 of 67
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard'" Perlite Roof Insulation
Minimum'/" thick N/A N/A
StructodeO High Density Fiber Board
Minimum %"thick N/A N/A
SECUROCK° Gypsum -Fiber Roof Board, DensDeck® Prime
Minimum'/" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard PAS 117 for
insulation attachment.
Base Sheet: Install one ply of GAFGLAS® 475 Base Sheet or Tri-Ply® #75 Base Sheet.
Adhered with any approved mopping asphalt applied within the EVT range and at
a rate of 20-40 lbs./sq. (See General Limitation #4).
Ply Sheet: Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5 or Ruberoid® 20 Smooth
adhered in a full mopping of approved asphalt applied within the EVT range and
at a rate of 20-40 lbs./sq.
Membrane: Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,
Ruberoid® Mop Granule FR, Ruberoid® Mop Plus Granule FR or Ruberoid®
EnergyCap' Mop Plus Granule FR adhered with any approved mopping asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS®EnergyCap"' Mineral -Surfaced Cap Sheet adhered in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 18 of 67
Membrane Type: SBS
Deck Type H:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(5):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® 475 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' 914 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #3:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec'" #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #4:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tec'°' # 14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #5:
AccuTrac® Flat Plates or Drill-Tec7 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —75 psf, See General Limitation #7)
One or more of any of the following insulations.
Base Layer Insulation Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuard' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick - N/A N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 19 of 67
Top Layer Insulation Insulation Fasteners Fastener
(Table 3) Density/ftz
EnergyGuard' Perlite Roof Insulation
Minimum %" thick N/A N/A
Structodek' High Density Fiber Board
Minimum''/:" thick N/A N/A
SECUROCK' Gypsum -Fiber Roof Board, DensDeck' Prime
Minimum'/<" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: Install one or more plies of Ruberoid® 20 Smooth adhered with any approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
(See General Limitation #4).
Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid® Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap' Mop
Plus Granule FR, Ruberoid® EnergyCap' 30 Granule FR GAFGLAS' Mineral -
Surfaced Cap Sheet, Tri-Ply'BUR Granule Cap Sheet or GAFGLAS'
EnergyCap' Mineral -Surfaced Cap Sheet adhered with any approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
MIAMMADEUT , COUNTY Expiration Date: 11/06l23
Approval Date: 11/01/18
Page 20 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(6):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac® Flat Plates or Drill-Tec7 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'°'
Option #4:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill -Tee' 914 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill-Tec"° 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —75 psf, See General Limitation #7)
One or more of any of the following insulations.
Base Layer Insulation Insulation Fasteners Fastener
(Table 3) Density/W
EnergyGuard'Polyiso Insulation, EnergyGuard'"Tapered Polyiso Insulation,
EnergyGuard'"Ultra Polyiso Insulation, EnergyGuard'"RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 21 of 67
Top Layer Insulation Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Perlite Roof Insulation
Minimum %" thick N/A N/A
Structodek® High Density Fiber Board
Minimum'/:" thick N/A N/A
SECUROCK® Gypsum -Fiber Roof Board, DensDeck® Prime
Minimum 1/41' thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ft'. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: Install one or more plies of Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5
adhered with any approved mopping asphalt applied within the EVT range and
at a rate of 20-40 lbs./sq. (See General Limitation #4).
Membrane: Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,
Ruberoid® Mop Granule FR, Ruberoid® Mop Plus Granule FR or Ruberoid®
EnergyCap' Mop Plus Granule FR adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
3. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 22 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(7):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo"° Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' # 14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill -Tee'
Option #3:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee'' 3 in. Standard Steel Plates, Drill-Tec'
Option #4:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #5:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —75 psf, See General Limitation #7)
One or more of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuare Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 23 of 67
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
One of the following.
EnergyGuard'°' Perlite Roof Insulation
Minimum'/," thick N/A N/A
Structodek® High Density Fiber Board
Minimum'/2" thick N/A N/A
SECUROC10 Gypsum -Fiber Roof Board, DensDeck® Prime
Minimum'/" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ft'. Please refer to Rooting Application Standard RAS 117 for
insulation attachment.
Base Sheet: Install one ply of GAFGLAS® 475 Base Sheet or Tri-Ply® #75 Base Sheet.
Adhered with any approved mopping asphalt applied within the EVT range and
at a rate of 20-40 lbs./sq. (See General Limitation #4).
Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid®
EnergyCap'' 30 Granule FR, Ruberoid® Mop Granule, Tri-Ply® SBS Granule
Cap Sheet, Intec Flex PRF, Ruberoid® Mop Granule FR, Ruberoid® Mop Plus
Granule FR or Ruberoid®EnergyCap'' Mop Plus Granule FR adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or
GAFGLAS® EnergyCap'' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
3. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOATS Membrane or United Coatings"" Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 24 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(8):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill -Ted" 3 in. Standard Steel Plates, Drill -Ted"
Option #3:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee #14 Fasteners and Drill-Tec'" 3 in. Standard Steel Plates, Drill-Tec'
Option #4:
AccuTrac® Flat Plates or Drill-Tec ' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tecn' #14 Fasteners and Drill -Tee 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —75 psf, See General Limitation #7)
One or more of any of the following insulations.
Base Layer Insulation Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard'Polyiso Insulation, EnergyGuard'°'Tapered Polyiso Insulation,
EnergyGuard'Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 25 of 67
Top Layer Insulation Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Perlite Roof Insulation
Minimum'/<" thick N/A N/A
Structodek® High Density Fiber Board
Minimum''/z" thick N/A N/A
SECUROCK' Gypsum -Fiber Roof Board, DensDeck' Prime
Minimum'/4" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ft. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: Two or more plies of GAFGLAS' Ply 4, Tri-Ply® Ply 4 Ply Sheet or
GAFGLAS® FlexPly'" 6 adhered with any approved mopping asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation
#4).
Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid® Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid' EnergyCap' Mop
Plus Granule FR, Ruberoid® EnergyCap" 30 Granule FR, GAFGLAS® Mineral -
Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS®
EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60'lbs./sq.
2. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 26 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(9):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOuf ' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo" Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. I -
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec"' 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-Tec'
Option #4:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tec' # 14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option 45:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Base Insulation Layer
Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuare Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuarC RH Tapered Polyiso Insulation
Minimum 1" thick N/A
N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 27 of 67
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard' Perlite Roof Insulation
Minimum'/<" thick N/A N/A
Structodek® High Density Fiber Board
Minimum''/a" thick N/A N/A
SECUROCK' Gypsum -Fiber Roof Board, DensDeck' Prime
Minimum'/" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: Install one ply of Ruberoid® 20 Smooth adhered with any approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See
General Limitation #4).
Ply Sheet: Ruberoid® Mop Smooth or Ruberoid® Mop Smooth 1.5 adhered with any
approved mopping asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
Membrane: Ruberoid' Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,
Ruberoid' Mop Granule FR, Ruberoid' Mop Plus Granule FR or Ruberoid'
EnergyCap' Mop Plus Granule FR adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
i
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or
GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 28 of 67
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Description: Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(10): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. I -
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill-Tec'" 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac® Flat Plates or Drill-Tec'" 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #4:
AccuTrac® Flat Plates or Drill -Tee'' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tec' # 14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —82.5 psf, See General Limitation #7)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners_ Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuard' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 29 of 67
Base Sheet:
GAFGLAS® Stratavent® Perforated Venting Base Sheet is loose laid over the
insulation with 2 in. side laps
Membrane:
Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid®
EnergyCap' 30 Granule FR, Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap
Sheet, Intec Flex PRF, Ruberoid® Mop Granule FR, Ruberoid® Mop Plus Granule
FR, Ruberoid® EnergyCap'' Mop Plus Granule FR or Tri-Ply® SBS Granule Cap
Sheet adhered in a full mopping of approved asphalt applied within the EVT range
and at a rate of 20-40 lbs./sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2.
GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
TOPCOAT® Surface Seal SB or United Coatings" Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
nwni Dane courrry Expiation Date: 11/06/23
ET 0=1
Approval Date: 11/01/18
Page 30 of 67
Membrane Type: SBS
Deck Type II:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(11):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet, or
(optional)
VersaShield® Sold'" Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. !-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —15 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. !-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure -52.5 psf, See General Limitation #7)
Fastening
Drill -Ted' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure -52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'°'
Option #4:
AccuTrac® Flat Plates or Drill -Tee'' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure -67.5 psf, See General Limitation #7)
Fastening
Drill-Tec'' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrae Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure -82.5 psf, See General Limitation #7)
One or more layers of any of the following insulations.
Base Layer Insulation Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard'' Tapered Polyiso Insulation,
EnergyGuard' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 31 of 67
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet:
GAFGLAS® Stratavent® Perforated Venting Base Sheet is loosely -laid over the
insulation with 2 in. side laps
Ply Sheet:
Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet or
GAFGLAS® FlexPly" 6 adhered with any approved mopping asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation
#4).
Membrane:
Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid® Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap' Mop
Plus Granule FR, Ruberoid® EnergyCap' 30 Granule FR, GAFGLAS® Mineral -
Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS®
EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2.
TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings'' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 32 of 67
Membrane Type: SBS
Deck Type H: Wood, Insulated
Deck Description: Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(12): All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-Tec'"
Option #3:
AccuTrae Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec'' 3 in. Standard Steel Plates, Drill -Tee'
Option #4:
AccuTrac® Flat Plates or Drill-Tecc' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tec" # 14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —82.5 psf, See General Limitation #7)
One or more layers of any of the following insulations.
Insulation for Base Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuarC Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 33 of 67
Base Sheet: GAFGLAS® Stratavent® Perforated Venting Base Sheet is loosely -laid over the
insulation with 2 in. side laps
Ply Sheet: Install one or more plies of Ruberoid® 20 Smooth adhered with any approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
(See General Limitation #4).
Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF Ruberoid® Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap' Mop
Plus Granule FR, Ruberoid® EnergyCap' 30 Granule FR, GAFGLAS® Mineral -
Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS®
EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. TOPCOATS' Surface Seal SB or United Coatings'' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings'" Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 34 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(13):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo'' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth
or GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as
described below.
Fastening
Miami -Dade County Approved min. 12 ga, annular ring shank nails and min. !-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. !-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee # 14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'"
Option #4:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in
the field of the sheet in three staggered rows.
(Maximum Design Pressure —82.5 psf, See General Limitation #7)
One or more layers of any of the following insulations.
Insulation for Base Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuarC Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuard' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 35 of 67
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs./100 ft=. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet:
GAFGLAS® Stratavent® Perforated Venting Base Sheet is loosely -laid over the
insulation with 2 in. side laps
Ply Sheet:
Install one or more plies of Ruberoid® Mop Smooth, Ruberoid® Mop Smooth
1.5 adhered with any approved mopping asphalt applied within the EVT range
and at a rate of 20-40 lbs./sq. (See General Limitation #4).
Membrane:
Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,
Ruberoid® Mop Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid®
EnergyCap' Mop Plus Granule FR, GAFGLAS® Mineral -Surfaced Cap Sheet,
Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral -
Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 2040 lbs./sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood
coat of approved asphalt at 60 lbs./sq.
2.
TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 36 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type A(14):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet,
(optional)
VersaShield® Solo 'I Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® 475 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth
or GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as
described below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. !-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. (-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill -
Option #3:
Tec' AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat)
are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in.
o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -
Option #4:
Tee' AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat)
are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c.
in the field of the sheet in two staggered rows.
(Maximum Design Pressure —67.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -
Option #5:
Tec7 AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat)
are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c.
in the field of the sheet in three staggered rows.
(Maximum Design Pressure —82.5 psf, See General Limitation #7)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard" Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation,
EnergyGuare Ultra Polyiso Insulation, EnergyGuard'' RH Polyiso Insulation,
EnergyGuard' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
NOA No.: 18-0919.12
Expiration Date: I1/06/23
Approval Date: 11/01/18
Page 37 of 67
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs.1100 ft. Please refer to Roofing Application Standard PAS 117 for
insulation attachment.
Base Sheet:
GAFGLAS® Stratavent® Perforated Venting Base Sheet is loosely -laid over the
insulation with 2 in. side laps
Interply Sheet:
Install one ply of Ruberoid® 20 Smooth adhered with any approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See
General Limitation #4).
Ply Sheet:
Ruberoid® Mop Smooth or Ruberoid® Mop Smooth 1.5 adhered with any
approved mopping asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
Membrane:
Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,
Ruberoid® Mop Granule FR, Ruberoid® Mop Plus Granule FR or Ruberoid®
EnergyCap'' Mop Plus Granule FR adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood
coat of approved asphalt at 60 lbs./sq.
2.
GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS® EnergyCap'°' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 38 of 67
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max
System Type B(1): Base layer of insulation is mechanically attached to roof deck. Any subsequent
layers are then adhered to base layer of insulation. Membrane is subsequently
fully or partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier: FireOut'' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck
(optional) Protection, VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck®Roof
Board, SECUROCK® Gypsum -Fiber Roof Board or SECUROCK® Glass -Mat
Roof Board.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' RA Polyiso Insulation
Minimum 2.0" thick 1, 2, 4, 5 1:3.2 ft'
EnergyGuard' RN Polyiso Insulation
Minimum 1.4" thick 1, 2, 4, 5 1:3 W
EnergyGuard' Polyiso Insulation
Minimum 1.5" thick 1, 2, 4, 5 1:2 ft'
EnergyGuare Perlite Roof Insulation
Minimum'/" thick 1, 2, 4, 5 1:2 ft'
Structodek® High Density Fiber Board
Minimum 1 thick 1, 2, 4, 5 1:2 ft'
Note: Base layers of insulation shall be mechanically attached using the fastener density listed.
The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners
shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm
compliance with the wind load requirements. Please refer to Roofing Application Standard RAS
117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavene Perforated
Venting Base Sheet laid dry or a layer of EnergyGuard— Perlite Roof Insulation or wood fiber
overlay board on all polyisocyanurate applications.
Top Insulation Layer
Insulation Fasteners
Fastener
(Table 3)
Density/ft'
Any of the insulation listed for Base Layer, above.
Minimum thickness same as above
N/A
N/A
Structodek® High Density Fiber Board, EnergyGuard'
Perlite Recover Board
Minimum''/2" thick
N/A
N/A
NOA No.: 18-0919.12
niani•owoe COUNTY
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 39 of 67
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT
range and at a rate of 20-40 lbs./100 ftz. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation boards used as a top layer shall be installed with the
polyisocyanurate face down.
Base Sheet:
(Optional) Install one ply of GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base
Sheet, GAFGLAS® #80 Ultimate° Base Sheet, GAFGLAS® Ply 4; Tri-Ply® Ply 4
Ply Sheet, GAFGLAS® F1exPly' 6, Ruberoid' Mop Smooth, Ruberoid' Mop
Smooth 1.5, Ruberoid' Mop Plus Smooth or Ruberoid' 20 Smooth directly over
the top layer of insulation. Adhere with any approved mopping asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.; (See General Limitation
#4).
OR
GAFGLAS' Stratavent' Perforated Venting Base Sheet loose laid dry (not for use
with wood fiber board or perlite top layer insulation).
Ply Sheet:
(Optional) One or more plies GAFGLAS' Ply 4, Tri-Ply' Ply 4 Ply Sheet,
GAFGLAS' FlexPly" 6 sheet or GAFGLAS' #80 Ultima' Base Sheet adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of
20-40 lbs./sq.
Membrane:
One or more plies of Ruberoid' 20 Smooth, Ruberoid' 30 Granule, Ruberoid'
EnergyCap' 30 Granule FR, Ruberoid' 30 Granule FR, Ruberoid' 30 Plus
Granule FR, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid'
Mop Plus Smooth, Ruberoid' Mop Granule FR, Ruberoid' Mop Granule, Tri-Ply'
SBS Granule Cap Sheet, Intec Flex PRF, , Ruberoid' Mop Plus Granule,
Ruberoid' Mop Plus Granule FR or Ruberoid' EnergyCap' Mop Plus Granule FR
fully adhered in a full mopping of approved asphalt applied within the EVT range
and at a rate of 20-40 lbs./sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2.
GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet
or GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3.
TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings'' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4.
Fiber Aluminum Roof Coating.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 40 of 67
Membrane Type: APP/SBS Heat Weld
Deck Type 1I: Wood, Insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type B(2): Base layer of insulation is mechanically attached to roof deck.
Any subsequent
layers are then adhered to base layer of insulation. Membrane is subsequently
fully or partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier: FireOut' Fire Barrier Coating, VersaShield®Fire-Resistant Roof Deck Protection
(optional) or Securock® Gypsum -Fiber Roof Board.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners
Fastener
(Table 3)
Density/ftz
EnergyGuard' RA Polyiso Insulation
Minimum 2.0" thick 1, 2, 4, 5
1:3.2 ft2
EnergyGuard' RN Polyiso Insulation
Minimum 1.4" thick 1, 2, 4, 5
1:3 ft2
EnergyGuard'' Polyiso Insulation
Minimum 1.5" thick 1, 2, 4, 5
1:2 W
EnergyGuard' RA Composite Polyiso Insulation
Minimum 1.5" thick 1, 2, 4, 5
1:3 ft2
EnergyGuard" Perlite Roof Insulation
Minimum %" thick 1, 2, 4, 5
1:2 W
Structodek® High Density Fiber Board
Minimum 1" thick 1, 2, 4, 5
1:2 ft2
Note: Base layers of insulation shall be mechanically attached using the fastener density listed.
The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners
shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm
compliance with the wind load requirements. Please refer to Roofing Application Standard RAS
117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent® Perforated
Venting Base Sheet laid dry or a layer of EnergyGuard7 Perlite Roof Insulation or wood fiber
overlay board on all polyisocyanurate applications.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
Any of the insulation listed for Base Layer, above.
Minimum thickness same as above N/A N/A
Structodek® High Density Fiber Board, EnergyGuard'" Perlite Recover Board
Minimum''/i" thick N/A N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT
range and at a rate of 20-40 lbs./100 It'. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation boards used as a top layer shall be installed with the
polyisocyanurate face down.
NOA No.: 18-0919.12
Muni-DAne COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 41 of 67
Base Sheet:
Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet,
GAFGLAS® 480 Ultima' Base Sheet, GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply
Sheet, GAFGLAS® FlexPly' 6, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth
1.5, Ruberoid Mop Plus Smooth, Ruberoid® 20 Smooth, Ruberoid® HW Smooth
or Ruberoid® HW 25 Smooth directly over the top layer of insulation. Adhere
with any approved mopping asphalt applied within the EVT range and at a rate of
20-40 lbs./sq.;
(See General Limitation 44).
OR
GAFGLAS® Stratavent® Perforated Venting Base Sheet loose laid dry (not for use
with wood fiber board or perlite top layer insulation).
Ply Sheet:
(Optional, required when using Ruberoid® 20 Smooth) One or more plies
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® F1exPly' 6 sheet or
GAFGLAS® #80 Ultima' Base Sheet adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane:
One ply of Ruberoid® Torch Smooth, Tri-Ply® APP Smooth Membrane, Ruberoid®
Torch Granule, Tri-Ply® APP Granule Cap Sheet,, Ruberoid® EnergyCap' Torch
Granule FR, Ruberoid®Torch Plus Granule or Ruberoid® Torch Plus Granule FR,
Ruberoid® EnergyCap' Torch Plus Granule FR torch applied according to
manufacturer's application instructions.
Or
One or more plies of Ruberoid® HW Plus Granule, Ruberoid® HW Plus Granule
FR, Ruberoid® HW Granule FR, Ruberoid® EnergyCap' HW Plus Granule FR,
Ruberoid® HW Granule, Ruberoid® HW Smooth and Ruberoid® HW 25 Smooth
applied according to manufacturer's application instructions.
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2.
GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet
or GAFGLAS®EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3.
TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings" Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4.
Fiber Aluminum Roof Coating.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 42 of 67
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type C(1): All layer of insulation are mechanically attached to roof deck. Membrane is
subsequently fully or partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier: FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection,
(optional) VersaShield® Solo"" Fire -Resistant Slip Sheet, DensDeck®Roof Board,
SECUROCK® Gypsum -Fiber Roof Board or SECUROCK® Glass -Mat Roof
Board.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' RA Polyiso Insulation, EnergyGuard' RN Polyiso Insulation
Minimum 1.3" thick N/A N/A
EnergyGuard' Polyiso Insulation
Minimum 1.4" thick N/A N/A
EnergyGuard' RA Composite Polyiso Insulation
Minimum 1.5" thick N/A N/A
EnergyGuard' Perlite Roof Insulation
Minimum %" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' RA Polyiso Insulation
Minimum 2.0" thick
1, 2, 4, 5
1:3.2 It'
EnergyGuard' RN Polyiso Insulation
Minimum 1.4" thick
1, 2, 4, 5
1:3 ft'
EnergyGuard' RA Polyiso Insulation, EnergyGuard'
Polyiso Insulation
Minimum 1.5" thick
1, 2, 4, 5
1:2 ft2
EnergyGuard' RA Composite Polyiso Insulation
Minimum 1.5" thick
1, 2, 4, 5
1:3 ft2
EnergyGuare Perlite Roof Insulation
Minimum'/" thick
1, 2, 4, 5
1:2 ft2,
StructodcO High Density Fiber Board
Minimum 1" thick
1, 2, 4, 5
1:2 ft'
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 43 of 67
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of
GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuarC
Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications.
Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet,
GAFGLAS® #80 Ultima'" Base Sheet GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet,
GAFGLAS® FlexPly" 6, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5,
Ruberoid® Mop Plus Smooth or Ruberoid® 20 Smooth directly over the top layer
of insulation. Adhere with any approved mopping asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. If base sheet is applied directly to
polyisocyanurate insulation only a spot or strip mopped application as detailed in
this approval the use of an overlay board is approved; (See General Limitation
#4).
OR
GAFGLAS® Stratavent® Perforated Venting Base Sheet loose laid dry (not for use
with wood fiber board or perlite top layer insulation).
Ply Sheet: (Optional) One or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet,
GAFGLAS® F1exPly' 6 or GAFGLAS® #80 Ultima" Base Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
Membrane: One or more plies of Ruberoid® 20 Smooth, Ruberoid® 30 Granule, Ruberoid®
EnergyCap' 30 Granule FR, Ruberoid® 30 Granule FR, Ruberoid® 30 Plus
Granule FR, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid®
Mop Plus Smooth, Ruberoid® Mop Granule FR, Ruberoid® Mop Granule,,
Ruberoid® Mop Plus Granule, Ruberoid® Mop Plus Granule FR fully adhered in
an approved asphalt at an application rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet
or GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3. TOPCOAr Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings'"' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 44 of 67
Membrane Type: APP/SBS Heat Weld
Deck Type II: Wood, Insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type C(2): All layer of insulation are mechanically attached to roof deck. Membrane is
subsequently fully or partially adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier: FireOut" Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection,
(optional) VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck®Roof Board, or
SECUROCK® Gypsum -Fiber Roof Board, or SECUROCK® Glass -Mat Roof Board.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard' RA Polyiso Insulation,
EnergyGuard' RN Polyiso Insulation
Minimum LY thick N/A N/A
EnergyGuard' Polyiso Insulation
Minimum 1.4" thick N/A N/A
EnergyGuard'' RA Composite Polyiso Insulation
Minimum 1.5" thick N/A N/A
EnergyGuard' Perlite Roof Insulation, EnergyGuard' Perlite Recover Board
Minimum'/<" thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer
EnergyGuard'" RA Polyiso Insulation
Minimum 2.0" thick
EnergyGuard' RN Polyiso Insulation
Minimum 1.4" thick
EnergyGuard'" Polyiso Insulation
Minimum 1.5" thick
EnergyGuard" RA Composite Polyiso Insulation
Minimum 1.5" thick
EnergyGuard' Perlite Roof Insulation
Minimum'/." thick
Structodek® High Density Fiber
Minimum 1" thick
Insulation Fasteners Fastener
(Table 3) Density/ft'
1, 2, 4, 5 1:3.2 ft2
1,2,4,5 1:3W
1, 2, 4, 5 1:2 IF
1,2,4,5 1:3W
1, 2, 4, 5 1:2 ft'
1, 2, 4, 5 1:2 ft'
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 45 of 67
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS'
Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuard" Perlite Roof
Insulation or wood fiber overlay board on all polyisocyanurate applications.
Base Sheet: Install one ply of GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS®
480 Ultima' Base Sheet, GAFGLAS' Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS®
F1exPly" 6, Ruberoid' Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop
Plus Smooth or Ruberoid® 20 Smooth directly over the top layer of insulation.
Adhere with any approved mopping asphalt applied within the EVT range and at a
rate of 20-40 lbs./sq. If base sheet is applied directly to polyisocyanurate insulation
only a spot or strip mopped application as detailed in this approval the use of an
overlay board is approved; (See General Limitation #4).
OR
GAFGLAS® Stratavent® Perforated Venting Base Sheet loose laid dry (not for use
with wood fiber board or perlite top layer insulation).
Ply Sheet: (Optional, required when using Ruberoid® 20 Smooth) One or more plies
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® F1exPly, 6 or GAFGLAS®
#80 Ultima' Base Sheet adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq.
Membrane: One ply of Ruberoid® Torch Smooth, Tri-Ply® APP Smooth Membrane, Ruberoid®
Torch Granule, Tri-Ply® APP Granule Cap Sheet, , Ruberoid' EnergyCap' Torch
Granule FR, Ruberoid' EnergyCap' Torch Plus Granule FR or Ruberoid® Torch
Plus Granule FR torch applied according to manufacturer's application instructions.
Or
One or more plies of Ruberoid' HW Plus Granule, Ruberoid® HW Plus Granule FR,
Ruberoid' HW Granule FR, Ruberoid' EnergyCar HW Plus Granule FR,
Ruberoid' HW Granule, Ruberoid' HW Smooth and Ruberoid' HW 25 Smooth
applied according to manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet
or GAFGLAS'EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings'*' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 18-0919.12
MIAMI-DADE COUNTY Expiration Date:.11/06/23
Approval Date: 11/01/18
Page 46 of 67
Membrane Type: SBS/SBS Cold Applied
Deck Type 1I: Wood, Insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type D(1): All insulation is loose laid with preliminary attachment to roof deck. Anchor
sheet is subsequently mechanically fastened through insulation to the roof deck.
All General and System Limitations shall apply.
Fire Barrier: FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck
(optional) Protection, VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck®Roof
Board, SECUROCK® Gypsum -Fiber Roof Board or SECUROCK® Glass -Mat
Roof Board.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard' Polyiso Insulation, EnergyGuard' RA Polyiso Insulation,
Structodek® High Density Fiber Board
Minimum 1" thick N/A N/A
Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet,
GAFGLAS® 480 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting
Base Sheet or Ruberoid® 20 Smooth applied over the loose laid insulation with 2"
side laps mechanically fastened to deck as described below;
Fastening
Drill-Tec"' #12 Fastener or Drill -Tee' #14 Fastener and Drill-Tec' 3" Steel
Option #1:
Plate, Drill -Tee' AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate
installed through the base sheet and insulation in 3 rows 12" o.c. One row is in
the 2" side lap. The other rows are equally spaced approximately 12.5" o.c. in
the field of the sheet.
Fastening
Drill-Tec"' #12 Fastener or Drill-Tec'' #14 Fastener and Drill-Tec' 3" Steel
Option #2:
Plates in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are
equally spaced approximately 9" o.c. in the field of the sheet.
Fastening
Drill -Tee' #12 Fastener or Drill-Tec' 414 Fastener and Drill-Tec' 3" Steel
Option #3:
Plate, Drill-Tec' AccuTraO Flat Plate or Drill -Tee' AccuTrac® Recessed Plate
installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the
2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the
field of the sheet.
Ply Sheet:
(Optional) One or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet,
GAFGLAS® FlexPly'" 6, GAFGLAS® #80 Ultima"" Base Sheet, Ruberoid® Mop
Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth or Ruberoid®
20 Smooth adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq.
NOA No.: 18-0919.12
Mani-DADE courrrr Expiration Date: 11/06/23
�� Approval Date: 11/01/18
Page 47 of 67
Membrane: One or more plies of Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5,
Ruberoid® Mop Plus Smooth Ruberoid® Mop Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, , Ruberoid® Mop Plus
Granule, Ruberoid® 20 Smooth, Ruberoid® 30 Granule, Ruberoid® EnergyCap'
30 Granule FR, Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR or
Ruberoid® Mop Plus Granule FR in adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Or
One or more plies of Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5,
Ruberoid® Mop Plus Smooth Ruberoid® Mop Granule, Tri-Ply® SBS Granule
Cap Sheet, Intec Flex PRF„ Ruberoid® Mop Granule FR, Ruberoid® Mop Plus
Granule, Ruberoid® 20 Smooth, Ruberoid® 30 Granule, Ruberoid® EnergyCap'
30 Granule FR, Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR or
Ruberoid® Mop Plus Granule FR adhered in MatrixTM 102 SBS Membrane
Adhesive at an application rate of 1-2 gal./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within a
current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet
or GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings'' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: —45 psf. (See General Limitation #9)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 48 of 67
Membrane Type: APP/SBS Heat Weld
Deck Type 1I:
Wood, Insulated
Deck Description:
Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type D(2):
All insulation is loose laid with preliminary attachment to roof deck. Anchor
sheet is subsequently mechanically fastened through insulation to the roof deck.
All General and System Limitations shall apply.
Fire Barrier:
FireOuf' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck
(optional)
Protection, VersaShield® Solo'' Fire -Resistant Slip Sheet, DensDeck®Roof
Board, SECUROCK® Gypsum -Fiber Roof Board or SECUROCK® Glass -Mat
Roof Board.
One or more layers of
any of the following insulations.
Insulation Layer
Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard' Polyiso Insulation, EnergyGuard' RA Polyiso Insulation
Minimum 1.3" thick
N/A N/A
StructodeV High Density Fiber Board
Minimum 1" thick N/A N/A
Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet,
GAFGLAS® #80 Ultima' Base Sheet; GAFGLAS® Stratavent® Nailable Venting
Base Sheet or Ruberoid® 20 Smooth base sheet applied over the loose laid
insulation with 2" side laps mechanically fastened to deck as described below;
Fastening Drill-Tec' #12 Fastener or Drill-Tec' #14 Fastener or and Drill-Tec' 3" Steel
Option #1: Plate, Drill-Tec'' AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate
installed through the base sheet and insulation in 3 rows 12" o.c. One row is in
then" side lap. The other rows are equally spaced approximately 12.5" o.c. in
the field of the sheet.
Fastening Drill-Tec' #12 Fastener or Drill -Tee' #14 Fastener or and Drill-Tec'" 3" Steel
Option #2: Plate, Drill-Tec'°' AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate
installed in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are
equally spaced approximately 9" o.c. in the field of the sheet.
Fastening Drill-Tec' #12 Fastener or Drill-Tec' # 14 Fastener or and Drill-Tec' 3" Steel
Option #3: Plate installed through the base sheet and insulation in 4 rows 8" o.c. One row is
in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in
the field of the sheet.
Ply Sheet: (Optional) One or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet,
GAFGLAS® FlexPly"' 6 sheet or GAFGLAS® 480 Ultima Base Sheet adhered in
a full mopping of approved asphalt applied within the EVT range and at a rate of
20-40 lbs./sq.
NOA No.: I8-0919.12
MAMIAADE COUNTY Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 49 of 67
Membrane: One ply of Ruberoid®Torch Smooth, Tri-Ply® APP Smooth, Ruberoid®Torch
Granule, Tri-Ply® APP Granule, Ruberoid® EnergyCar Torch Granule FR,
Ruberoid® EnergyCap' Torch Plus Granule FR or Ruberoid® Torch Plus Granule
FR torch applied according to manufacturer's application instructions.
Or
One or more plies of Ruberoid® HW Plus Granule, Ruberoid® HW Plus Granule
FR, Ruberoid® HW Granule FR, Ruberoid® EnergyCap' HW Plus Granule FR,
Ruberoid® HW Granule, Ruberoid® HW Smooth and Ruberoid® HW 25 Smooth
applied according to manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet
or GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3. TOPCOAT® Surface Seal SB or United Coatings"" Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings"" Roof Mate MB, Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings'' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 50 of 67
Membrane Type: SBS/SBS Cold Applied
Deck Type 1: Wood, Non -insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(1):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection,
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck® Roof Board,
SECUROCK® Gypsum -Fiber Roof Board, or SECUROCK Glass -Mat Roof Board.
Base sheet:
GAFGLAS® #80 Ultima ' Base Sheet, GAFGLAS® Stratavent® Nailable Venting
Base Sheet, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25
Smooth base sheet mechanically fastened to deck as described below:
Fastening
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® F1exPly'" 6, GAFGLAS®
Option #1:
#75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base sheets attached to
deck with approved annular ring shank nails and tin caps at a fastener spacing of 9"
o.c. at the lap staggered and in two rows 18" o.c. in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® F1exPly" 6, GAFGLAS®
Option #2:
#75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base sheets attached to
deck with Drill-Tec' #12 Fastener or Drill -Tee' #14 Fastener and Drill -Tee' 3"
Steel Plate, Drill-Tec° AccuTrac® Flat Plate or Drill-Tec" AccuTrac® Recessed
Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are
equally spaced approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening
GAFGLAS® F1exPly' 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or
Option #3:
any of above base sheets attached to deck with approved annular ring shank nails
and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows
9" o.c. in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure —52.5 psf. See General Limitation #7)
Fastening
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base sheets
Option #4:
attached to deck with Drill-Tec' #12 Fastener or Drill -Tee' #14 Fastener and Drill -
Teo"' 3" Steel Plate, Drill -Tee' AccuTrac® Flat Plate or Drill -Tee' AccuTrac®
Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other
rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
Fastening
GAFGLAS® #80 Ultima' Base Sheet, Ruberoid® 20 Smooth, Ruberoid®Mop
Option #5:
Smooth base sheet attached to deck approved annular ring shank nails and 3"
inverted Drill-Tec' 3" Steel Plate at a fastener spacing of 9" o.c. at the 4" lap
staggered in two rows 9" in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure —60 psf. See General Limitation #7)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 51 of 67
Fastening GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base sheets
Option #6: attached to deck with Drill -Tee' # 12 Fastener or Drill-Tec' # 14 Fastener and Drill-
Tec7 3" Steel Plate, Drill -Tee' AccuTrace Flat Plate or Drill-Tec' AccuTrac'
Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other
rows are equally spaced approximately 9" o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf. See General Limitation #7)
Ply Sheet: (Optional) One or more plies GAFGLAS' Ply 4, Tri-Ply' Ply 4 Ply Sheet,
GAFGLAS' FlexPly" 6, GAFGLAS' #80 Ultima Base Sheet, Ruberoid' Mop
Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus Smooth or Ruberoid' 20
Smooth sheet adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq.
Membrane: One or more plies of Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5,
Ruberoid' Mop Plus Smooth, Ruberoid' Mop Granule FR, Ruberoid' Mop Granule,
Tri-Ply' SBS Granule Cap Sheet, Intec Flex PRF, , Ruberoid' Mop Plus Granule,
Ruberoid' 20 Smooth, Ruberoid' 30 Granule, Ruberoid' EnergyCar 30 Granule
FR, Ruberoid' 30 Granule FR, Ruberoid' 30 Plus Granule FR, or Ruberoid' Mop
Plus Granule FR in adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq.
Or
One or more plies of Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5,
Ruberoid' Mop Plus Smooth, Ruberoid' Mop Granule, Tri-Ply' SBS Granule Cap
Sheet, Intec Flex PRF, , Ruberoid' Mop Granule FR, Ruberoid' Mop Plus
Granule, Ruberoid' 20 Smooth, Ruberoid' 30 Granule, Ruberoid' EnergyCap, 30
Granule FR, Ruberoid' 30 Granule FR, Ruberoid' 30 Plus Granule FR, or
Ruberoid' Mop Plus Granule FR adhered in MatrixTm 102 SBS Membrane Adhesive
at an application rate of 1-2 gal./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
Approved asphalt at 60 lbs./sq.
2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet
or GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 52 of 67
Membrane Type: APP/SBS Heat Weld
Deck Type 1: Wood, Non -insulated
Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type E(2):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System
Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck
(optional)
Protection, VersaShield® Solo'' Fire -Resistant Slip Sheet, DensDeck® Roof
Board, SECUROCK® Gypsum -Fiber Roof Board or SECUROCK® Glass -Mat
Roof Board.
Base sheet:
GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Stratavent® Nailable Venting
Base Sheet, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid®
Mop Plus Smooth, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid®
HW 25 Smooth mechanically fastened to deck as described below;
Fastening
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS® FlexPly' 6,
Option #1:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the lap staggered and in two rows 18" o.c. in the
field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure - 45 psf. See General Limitation #9)
Fastening
GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet, GAFGLAS F1exPly"" 6,
Option #2:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base
sheets attached to deck with Drill-Tec' # 12 Fastener or Drill-Tec'' # 14 Fastener
and Drill-Tec' 3" Steel Plate, Drill-Tec' AccuTrac® Flat Plate or Drill -Tee'
AccuTrac® Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 12.5" o.c. in the field of
the sheet.
(Maximum Design Pressure - 45 psf. See General Limitation #9)
Fastening
GAFGLAS® FlexPly'°' 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet
Option #3:
or any of above base sheets attached to deck with approved annular ring shank
nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in
two rows 9" o.c. in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure —52.5 psf. See General Limitation 97)
Fastening
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base
Option #4:
sheets attached to deck with Drill-Tec"" #12 Fastener or Drill-Tec' #14 Fastener
and Drill -Tee' 3" Steel Plate, Drill-Tec" ° AccuTrac® Flat Plate or Drill-Tec'
AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 53 of 67
Fastening GAFGLAS' #80 Ultima' Base Sheet, Ruberoid® 20 Smooth, Ruberoid' Mop
Option #5: Smooth base sheet attached to deck approved annular ring shank nails and 3"
inverted Drill-Tec' 3" Steel Plate at a fastener spacing of 9" o.c. at the 4" lap
staggered in two rows 9" in the field.
Not for use with DensDeck or SECUROCK Fire Barrier
(Maximum Design Pressure —60 psf. See General Limitation #7)
Fastening
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of above base
Option #6:
sheets attached to deck with Drill -Tee' # 12 Fastener, Drill-Tec' # 14 Fastener or
Drill-Tec'°' XHD Fastener and Drill -Tee' 3" Steel Plate, Drill -Tee' AccuTrac'
Flat Plate or Drill -Tee' AccuTrac' Recessed Plate installed 8" o.c. in 4 rows.
One row is in the 2" side lap. The other rows are equally spaced approximately
9" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #9)
Ply Sheet:
(Optional except over Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5,
Ruberoid® Mop Plus Smooth, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or
Ruberoid® HW 25 Smooth) One or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4,
or GAFGLAS® F1exPly' 6 sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq. or Ruberoid® Torch
Smooth torch applied according to manufacturer's application instructions.
Membrane:
One ply of Ruberoid® Torch Smooth, Tri-Ply® APP Smooth Membrane,
Ruberoid® Torch Granule, Tri-Ply® APP Granule Cap Sheet,, Ruberoid'
EnergyCap' Torch Granule FR, Ruberoid' EnergyCap' Torch Plus Granule FR,
or Ruberoid' Torch Plus Granule FR torch applied according to manufacturer's
application instructions.
Or
One or more plies of Ruberoid' HW Plus Granule, Ruberoid' HW Plus Granule
FR, Ruberoid' HW Granule FR, Ruberoid' EnergyCap' HW Plus Granule FR,
Ruberoid' HW Granule, Ruberoid' HW Smooth and Ruberoid' HW 25 Smooth
applied according to manufacturer's application instructions.
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2.
GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet
or GAFGLAS'EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
3.
TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4.
Fiber Aluminum Roof Coating.
Maximum Design
Pressure:
See Fastening Options
NOA No.: 18-0919.12
MIAMI-DADE COUNTY
Fn — *1 I
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 54 of 67
Membrane Type: SBS
Deck Type II:
Wood, Non -Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(3):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier:
FireOuf' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. I -
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill -Tee,
Option #3:
AccuTrac® Flat Plates or Drill-Tecn' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #4:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Fastening
Drill-Tec'' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —97.5 psf, See General Limitation #7)
Membrane:
Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid® Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap' Mop
Plus Granule FR or Ruberoid® EnergyCap' 30 Granule FR adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 55 of 67
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply®BUR Granule Cap Sheet or
GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
3. TOPCOAT'® Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT'® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 56 of 67
Membrane Type: SBS
Deck Type 1I: Wood, Non -Insulated
Deck Description: Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(4):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® 975 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8
Option #1:
in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side
laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8
Option #2:
in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side
laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill -Tee'
Option #3:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the
field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' 414 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #4:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the
field of the sheet in two staggered rows.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec'"3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —97.5 psf, See General Limitation #7)
Base Sheet:
Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 Ply Sheet or GAFGLAS®
FlexPly' 6 adhered with any approved mopping asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq. (See GeneralLimitation #4).
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 57 of 67
Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoid® Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap' Mop Plus
Granule FR, Ruberoid® EnergyCap' 30 Granule FR, GAFGLAS® Mineral -
Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet.or GAFGLAS®
EnergyCap' Mineral -Surfaced Cap Sheet fully adhered in an approved asphalt at
an application rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. TOPCOAT® Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings" Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOATr" Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum
Design Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 58 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Non -Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(5):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier:
FireOutn' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo"" Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS®Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. I -
Option 91:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' 414 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #4:
AccuTrae® Flat Plates or Drill -Tee' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #5:
AccuTrac® Flat Plates or Drill-Tec'°' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —97.5 psf, See General Limitation #7)
Base Sheet:
Install one or more plies of Ruberoid® 20 Smooth adhered with any approved
mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
(See General Limitation #4).
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 59 of 67
Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, Ruberoid® Mop
Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Ruberoide Mop
Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EnergyCap' Mop
Plus Granule FR or Ruberoid® EnergyCap' 30 Granule FR fully adhered with
any approved mopping asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
Or
GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet
or GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. TOPCOAT® Surface Seal SB or United Coatings" Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 60 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Non -Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(6):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill -Ted'
Option #4:
AccuTrae® Flat Plates or Drill -Tee'' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill -Tee'
Option #5:
AccuTrac® Flat Plates or Drill-Tec"° 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —97.5 psf, See General Limitation #7)
Base Sheet:
Install one or more plies of Ruberoid® Mop Smooth or Ruberoid® Mop Smooth
1.5 adhered with any approved mopping asphalt applied within the EVT range
and at a rate of 20-40 lbs./sq. (See General Limitation #4).
Membrane:
Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,
Ruberoid® Mop Granule FR, Ruberoid® Mop Plus Granule FR or Ruberoid®
EnergyCap' Mop Plus Granule FR adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 61 of 67
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2.
GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
3.
TOPCOATS' Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT'® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT'® Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4.
Fiber Aluminum Roof Coating.
Maximum Design
Pressure:
See Fastening Options
NOA No.: 18-0919.12
nianuonnecounrrr Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 62 of 67
Membrane Type: SBS
Deck Type 1I:
Wood, Non -Insulated
Deck Description:
Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(7):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLAS® 975 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratavent® Nailable Venting Base Sheet is secured as described
below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #1:
5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet
side laps and 8 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —45 psf, See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-
Option #2:
5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet
side laps and 6 in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill -Tee'
Option #3:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
Fastening
Drill -Tee' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec''
Option #4:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in
the field of the sheet in two staggered rows.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Fastening
Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'
Option #5:
AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are
spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the
field of the sheet in three staggered rows.
(Maximum Design Pressure —97.5 psf, See General Limitation #7)
Base Sheet:
Install one ply of Ruberoid® 20 Smooth adhered with any approved mopping
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See
General Limitation #4).
Ply Sheet:
Ruberoid® Mop Smooth or Ruberoid® Mop Smooth 1.5 adhered with any
approved mopping asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 63 of 67
Membrane: Ruberoid® Mop Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF,
Ruberoid® Mop Granule FR, Ruberoid® Mop Plus Granule FR or Ruberoid®
EnergyCap' Mop Plus Granule FR adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within
a current NOA.
I. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS® EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-
40 lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof
Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 64 of 67
Membrane Type: SBS Cold Applied
Deck Type 1I: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank secured 6 in. o.c. with #8 wood screws to
supports spaced 24 in. o.c. max.
System Type E(8):
Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier:
FireOut' Fire Barrier Coating, VersaShield' Fire -Resistant Roof Deck Protection
(optional)
or VersaShield' Solo' Fire -Resistant Slip Sheet.
Base Sheet:
Install one ply of GAFGLAS' #75 Base Sheet, Tri-Ply' 975 Base Sheet,
GAFGLAS' #80 Ultime Base Sheet or GAFGLAS' Stratavent' Nailable
Venting Base Sheet attached to deck with Drill-Tec' #12 Fasteners and Drill-
Tec' 3" Steel Plate spaced 8 in. o.c. in the min. 2.0 in. wide side laps and 8 in. ox
in three equally spaced, staggered rows in the field of the sheet.
Base Ply:
GAFGLAS' FlexPlym 6 adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq. in accordance with
manufacturer's instructions.
Membrane:
One or more plies of Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus Smooth,
Ruberoid Mop Granule or Intec Flex PRF adhered in MatrixTm 102 SBS
Membrane Adhesive at an application rate of 1.5 gal./sq.
Surfacing:
Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within a
current NOA.
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2.
GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply'BUR Granule Cap Sheet or
GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3.
TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4.
Fiber Aluminum Roof Coating.
Maximum Design
Pressure:
-105 psf; (See General Limitation #7)
NOA No.: 18-0919.12
wwru•DAuecourtTY Expiration Date: 11/06/23
Approval Date: 11/O1/18
Page 65 of 67
Membrane Type: SBS
Deck Type 1I: Wood, Non -Insulated
Deck Description: Min. 19/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank
nails to supports spaced 24 in. o.c. max.
System Type E(9): Anchor sheet is mechanically attached to roof deck. (Non -insulated systems)
All General and System Limitations shall apply.
Fire Barrier: FireOut' Fire Barrier Coating, VersaShield' Fire -Resistant Roof Deck Protection
(optional) or VersaShield' Solo' Fire -Resistant Slip Sheet.
Base Sheet: Install one ply of GAFGLAS' #80 Ultima' Base Sheet attached to deck with 12
ga., 1-1/4" galvanized ring shank nails through 32 ga. 1-5/8" diameter tin tabs as
stated below:
Fastening Option #1: 8 in. o.c. in the min. 4 in. wide side laps and 8 in. o.c in three staggered rows in
the field of the sheet.
(Maximum Design Pressure -75 psf,• See General Limitation #7)
Fastening Option #2: 9 in. o.c. in the min. 4 in. wide side laps and 9 in. o.c in two staggered rows in the
field of the sheet.
(Maximum Design Pressure -45 psf,• See General Limitation #9)
Base Ply: GAFGLAS' F1exPly'" 6 adhered in a full mopping of approved asphalt applied
(Optional) within the EVT range and at a rate of 20-40 lbs./sq. in accordance with
manufacturer's instructions.
Membrane: One or more plies of Ruberoid' Mop Granule, Tri-Ply' SBS Granule Cap Sheet,
Intec Flex PRF, Ruberoid® Mop Smooth, Ruberoid' Mop 1.5, Ruberoid' Mop
Plus Smooth, Ruberoid' Mop Plus Granule, Ruberoid' Mop Plus Granule FR,
Ruberoid' EnergyCap Mop Plus Granule FR, Ruberoid' Mop Granule FR,
Ruberoid' 30 Granule FR, Ruberoid' 30 Plus Granule FR or Ruberoid'
EnergyCap" 30 Granule FR in adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth
membranes. Chosen components must be applied according to
manufacturer's application instructions. All coatings must be listed within a
current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 60 lbs./sq.
2. GAFGLAS' Mineral -Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or
GAFGLAS' EnergyCar Mineral -Surfaced Cap Sheet adhered in a full mopping
of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. TOPCOAT' Surface Seal SB or United Coatings' Surface Seal SB Roof Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
OR
TOPCOAT' MB Plus or United Coatings' Roof Mate MB Plus Coating
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by
TOPCOAT' Membrane or United Coatings' Roof Mate TCM Coating
applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat.
4. Fiber Aluminum Roof Coating.
Maximum Design
Pressure:
MAMMADECOUNW
,.... 1
See Fastening Options
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 66 of 67
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® FlexPly' 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum '/A" DensDeck® Roof Board or %" Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIMITATIONS:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 11 I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 18-0919.12
Expiration Date: 11/06/23
Approval Date: 11/01/18
Page 67 of 67