HomeMy WebLinkAboutConstruction Plans4
IPRODUCT
FBC APPROVED PRODUCTS. LIST
SUB CATEGORY
STRUCTURAL COMPONENTS I STRUCTU .WALL
I STRUCTURAL COMPONENTS I FLOOD VENT
I EXTERIOR DOORS
EXTERIOR DOORS
` EXTERIOR DOORS
EXTERIOR DOORS
WINDOWS
EXTERIOR DOORS
EXTERIOR DOORS
EXTERIOR DOORS
4
SWINGING
SWINGING
ROLL -UP
ROLL -UP
SINGLE HUNG
ROLL -UP
ROLL -UP
ROLL -UP
MANUFACTURER
CARO-GINA:CARPORTS„INC.
6,Gauge�G'Pane
CRAWL SPACE DOOR SYSTEMS, INC.
16x8 Flood Vent
ELIXIR DOOR AND METAL COMPANY
Series 402-14
ELIXIR DOOR AND METAL COMPANY
Series 407
ASTA INDUSTRIES INC.
Model 203 (12' Max. Width)
CAROLINA CARPORTS, INC.
Steel Roll Up Sheet Door (12' Max. Width)
MI WINDOWS AND DOORS
Model 185 SH
CAROLINA CARPORTS, INC.
Steel Roll -Up Sheet Door- 8' Wide
CAROLINA CARPORTS, INC.
Steel Roll -Up Sheet Door - 10'Wide
CAROLINA CARPORTS, INC.
Steel Roll -Up Sheet Door -16' Wide
MAXIMUM ALLOWABLE
WIND SPEED
QA
APPROVAL
EXPIRATION
JENCLOSED
PARTIALLY
No.& DATE
DATE
OPEN
ENCLOSED
6 9-�':R5
04105/27
180
180
180
10/17
FL6702€1=R5'
0311027
180
180
180
0%10117
FL29622.1
09/01/20
N/A
N/A
N/A
05115/19
FL17996.3-R1
09/14/20
N/A
139
138
01/29/18
FL17996.5-R1
09/14/20
NIA
165
147
01/29118
FL8888.1-R5
12131/20
N/A
180
174
10/07/17
FL16806.1-R4
.11111/20
N/A
158
138
06/18/19
FL17499.1-R5
10/17/23
NIA
175
157
03/27/19
FL16806.2-R4
11/11/20
a N/A
180
180
06/18/19
FL16806.4-R4
11/11/20
N/A
1110
172
06/18/19
FL16806.3-R4
11111120
WA
155
133
06/18/19
1. DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS. PROVIDED THE FOLLOWING CONDITIONS ARE MET:
A PRODUCT SHALL HAVE A VALID FBC PR0 UGT APPROVAL
B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION REOURIEMENTS.
2. FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE
m ivcnn iron vvnnunr
TABLE 1
RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS
AVERAGE FASTENER SPACING
ON -CENTERS ALONG RAFTERS OR
MAXIMUM PURLINS, AND POSTS OR GIRTS
WIND ULTIMATE NOMINAL POST/RAFTER (INCHES)
RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END
CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS
11DT0150 89TO116 5:0 6 6
I C
151 TO 180 1 117 TO 139 4.0 6 6
VOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18
gauge hat channel roof pudins.
2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7' to 27° (1.5:12 to 6:12 pitch). Spacing
requirements for other roof heights and/or slopes may vary.
GROUND ANCHOR SCHEDULE
14
16
18
20
22
24
26
28
AILS 1C AND 1 DSHOWN ON SHEE
FILE CO
GENERAL NOTES:
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO
PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
2, THESE STRUCTURES ARE DESIGNEDAS NON -HABITABLE UTILITY/STORAGEBUILDINGS (RISK CATEGORY 1) CAPABLEOF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND.WIND.LOADS. IMPROVEMENTS
NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS,
INC.; WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE
APPLICATION OF ADDITIONAL LOADS.
3, ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
4, ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE FLORIDA. BUILDING CODE (FBC) AT THE
LOCATION OF THE BUILDING WITHIN THE STATE OF FLORIDA.
5, ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4' SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
6• CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-Wt AXW1 .4
WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6' OF EVERY POST LOCATION,. AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING
AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS.
8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LDT 1/2' x 5' OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS.
10. SLAB FOUNDATION SUBGRADE SOILSSHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC SIXTH
EDITION (2017) -BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED.
11. 14 GA FRAMING: 2-1/2' x 2-1/2' TUBE STEEL (TS) WITH 2-1/4' x 2-1/4' TS NIPPLES. _
12 GA FRAMING: 2-1/4' x 2-1/4' TS WITH 2' x 2' TS NIPPLES.
12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF
OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER
EVERY 305 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6.
Ih) _ METAL CARPORT INSTALLATION PLANS
170 180 AND DETAILS AND FRAMING AND
FASTENER SPECIFICATIONS
FOR CONSTRUCTION IN THE STATE OF FLORIDA
PREPARED FOR:
CAROLINA CARPORTS, INC.
P.O: BOX 1263
DOBSON, NORTH CAROLINA 27017
PREPARED BY.'.
BECHTOL ENGINEERING AND TESTING, INC.
60'Ancha 605 WEST NEW YORK AVENUE
Deta19C. DELAND; FLORIDA 32720
Certificate of Authorization No. 60005492
r 4'OF 6 �
PY REVIEW ORg
CODE COMPLIANCE
ST. LWCC�II/E 0^0�1�
THIS IS TO CERTIFY THAYI�f16GA�l1�T10NS AND
SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE
ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF
THE FLORIDA BUILDING CODE, SIXTH EDITION E (20M. THE PLANS
CARE ODE.
�D UNTILTHE NEXT REVISION OFT\\fFQsID*. PV RAG
.�` NSR . H
off.-.... . •.
1-
ICENO
,�`Z`; •' SF •, 'Sj, �_
BECHTOL ENGINEERI6IC> ' TESft-%M$ ':0
60S WEST NEW YORKAVENCE _
DEUWD. FLORIDA 32r20 CA III I ofAutliadzilimNa6/ I *`
// R �47E nxr ,427
MNLI®�ie � /ls •''.,ORIDA„•• \vim`
�'/jIIIIIr11j1`��\
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
XVBECHTOL ENGINEERING mkb NTSV
AND TIEUM 1e
Xvdo enuu.�.�now>euvi>me,,.arv: - tb '�"6' G2B001
� TB SHEET 10
I
BOW FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF BOW FRAME RAFTER UTILITY BUILDING - HORIZONTAL ROOF
FLOOD VENT (As applicable)-,ROLL-UPDOOR SWINGINGDOOR ROLL -UP DOOR SWINGING DOOR
(As applicable) (As applicable) (As applicable) (As applicable)
IIIIIiIII
s
_ _— __ ENCLOSED LENGTH VARIES
•s
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOT TO SCALE NOT TO SCALE NOT TO SCALE - NOT TO SCALE NOT TO SCALE NOT TO SCALE
BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF
.FLOOD VENT,(As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR
(As applicable) (As applicable) (As applicable) (As applicable)
a
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION. - TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE
NOT TO SCALE NOT TO SCALE
BOX EAVE FRAM_ E RAFTER OPEN CARPORT - VERTICAL ROOF
BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL ROOF
BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF
'
FLOOD VENT (Asa licable) ROLL -UP DOOR SWINGING DOOR
ROLL -UP DOOR SWINGINGDOOR
111111
NOR
As applicable) (As applicable)
(As applicable) (As applicable)
YPICAL,SIDE�ELEVATION
TYPICAL END ELEVATION
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
�FCAGSI . ATIO TYPICAL END ELEVATION
N�CALE - NOT TO SCALE
N� E NOT TO SCALE
NOT TO SCALE NOT TO SCALE
\YY
EVIEWED FOR �yYPs.R H
,.,
ST. LUCIE COUNTY
MWESTNEWYORlcRdR1q 0--- 8581NC:.
DET= LAND. FLORIDA 32PT
"
®q
BC
c
Certlflmfe of /7
7� __
Florldm License IasasseyJ/rs
\�
CAROLINA CARPdWfW, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
TYPICAL BOW RAFTER GABLE END ELEVATION
TYPICAL BOX EAVE RAFTER GABLE END.ELEVATION
P L P,IOAL BOXaEAVE�RAFTERxGABLEENDELEVA710
. otrzorzo
NOT TO SCALE
,NOT TO SCALE
NO7 TO SCALE
°
BE ENG/NEER/NG
r'r' mkb
-
NTS
I
'® W
'o'r'' G20DOI
mdm®no-rxamo-eei.Nor�wvmim ®-
T3
SHEET 20F8
4
a
26 GA GALVANIZED METAL ROOF PANELS
FASTENED TO RAFTERS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
12
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12.14 x 3/4' SDFs AT
EACH END (4 PER BRACE)
24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER
124' TO 3O RAFTER SPAN REQUIRES A TRUSSED RAF
TYPICAL
INTERIOR RAFTER/POST FRAME SECTION - BOW FRAME
NOT TO SCALE
M 4 0
OPTIONAL 24'-l" TO 30' TRUSSED RAFTER - BOW
LD
S
26 GA GALVANIZED METAL ROOF PANELS
FASTENED TO RAFTERS PER MANUFACTURERS
INSTALLATION INSTRUCTIONS
\ 12
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4' SDF's AT
EACH END (4 PER BRACE)
24' MA
>24'TO 30'
TYPICAL INTERIOR RAFTER/POST
FRAME SECTION - BOX EAVE - HORIZONTAL ROOF
NOT TO SCALE
TYPICAL RAFTER/POST FRAMING PLAN - BOX EAVE
NOT TO SCALE
SEE
TABLE 1
SHEET
6'—
26 GA GALVANIZED METAL ROOF PANELS
FASTENED TO PURLINS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
c-1-M' 18 GAUGE FURRING
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4' SDFs AT
EACH END (4 PER BRACE)
24' MAXIMUM
s24' TO W RAFTE
TYPICAL INTERIOR
RAFTERIPOST FRAME SECTION - VERTICAL ROOF
NOT TO SCALE
�1-1/2' 18 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) #12-14 x aW SELF -DRILLING
FASTENER SPACED NOT MORE THAN 48' O.C.
I
]
4
SEE
TABLE 1
SHEET
IOF6
LENG VARIES DEPENDING ON NUMBER
AND SPACING OF RAFTERS
TYPICAL
POSTIRAFTER FRAMING PLAN - VERTICAL ROOF
NOT TO SCALE
OPTIONAL 24'-l" TO 30' TRUSSED RAFTER - BOX EAVE
NOT TO SCALE
ROOF EXTENSION OPTION
TYPICAL LEAN-TO OI
NOT TO SCALE (BOX
24' 16 GA U-CHANNEL BRACE (S TO T POST)
46' 16 GA U-CHANNEL BRACE (8' TO 14' POST)
BRACE ANGLE SHALL BE MIN. 30'
1
1.
IN
-6'
TYPICAL BOW RAFTER GABLE END FRAMING PLAN
NOT TO SCALE
TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN
CODE COMPLIANCE
,ST. LUCIE COUNTY
LEAN-TO FRAMING PLAN
24. 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4' SELF -DRILLING
SCREWS AT EACH END
(4 PER BRACE)
MAIN STRUCTURE ST
3 PLAN (BOTH OPTIONS
LY STANDARD LEAN-TO IS APPLICASL(i
BECHTOL
608 WESTNE
CAROLINA CARPORTS' INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
SECNTOL ENGINEERING mkb NTS `V
Allen 7E6AN4 bm
mmxm�m.r�.ur.w.aramwrew.rt+noevmm '® It, '4 G20001
TB SHEET30F6
It-' x MINIMUM 5' TAPCON REDHEAD LOT
OR 1/2' x MINIMUM 5-7? EXPANSION ANCHOR
'H BASE RAIL WITHIN W OF EACH
POSTS ALONG SIDES AND EVERY END
IST ALONG END WALL SECTIONS
MINIMUM
2-1/2' EMBEDMENT
CONC. FOOTING(2500 PSI MIN.)
WITH 2 #SS CONTINUOUS
�1 CONCRETE BASE RAIL ANCHORAGE
In Not To Scale
DRILL 6/8' HOLE THROUGH THE.
BASE RAIL AND SECURE TO
ANCHOR EYE WITH 12' DIAMETER
IT I
L. - .y..'... -..
TS CONTINUOUS
BASE RAIL
(SEE GROUND ANCHOR
SCHEDULE; SHEET 1 OF S.
FOR REOUIRED ANCHOR)
G— CONTINUOUS 4'
CONCRETE PAVEMENT
EYE ANCHOR
�1 CONCRETE BASE RAIL ANCHORAGE
I G Not To Scale (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT
MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL 113)
TS TRUSSED RAFTER CHORD,
OR NON-STRUCTURAL HEADER
TS END POST OR DOOW /
WINDOW FRAME POST
TS BASEAVINDOW RAIL OR
NON-STRUCTURAL HEADER
GA IF ROLL -UP DOOR FRAME)
2'x2'x2' 16 GA ANGLE CUP
SECURE TO POST (EACH SIDE)
AND RAFTER CHORD/RAIL WITH
(4) #12-14 x 3/4' SDFs, (2) ON
TOP OR BOTTOM, (2) ON SIDE
NOTE: AT ROLL -UP DOOR
OPENINGS, POST SHOULD
BE FLUSH WITH RAIL END.
CLIP POST TO RAIL ONLY ON
SIDE OPPOSITE THE OPENING.
POST TO RAIL, TRUSS CHORD, OR
NON-STRUCTURAL HEADER CONN. DETAIL
Not To Scale
INSTALL 1/2' x MINIMUM S' TAPCON REDHEAD LOT
ANCHOR OR 1/2 x MINIMUM 5-12' EXPANSION ANCHOR DRILL 5/8' HOLE THROUGH THE 2' WASHERS
THROUGH BASE RAIL WITHIN 6' OF EACH BASE RAIL AND SECURE TO
RAFTER POSTS ALONG SIDES AND EVERY END ANCHOR EYE WITH 10 DIAMETER TS CONTINUOUS
WALL POST ALONG END WALL SECTIONS THROUGH -BOLT BASE RAIL
MIN. 8' TOP OF ASPHALT PAVEMENT
OR STABLE GROUND SURFACE
MINIMUM 2-1/2' EMBEDMENT
CONTINUOUS 4' CONCRETE PAVEMENT
R CONCRETE BASE RAIL ANCHORAGE
�� Not To Scale (OPTIONAL- OPEN CARPORTS ONLY)
�„ Not To Scale
TS RAFTER POST
1-1/2' x 1-1/2' a 2. 16 GA CLIP
ANGLESECURETO
POST AND BASE RAIL
WITH (4) #12-14 x 3/4' SDFs,
(2) ON TOP, (2) ON SIDE
CONTINUOUS BASE RAIL
END POST/BASE RAIL CONN.
RAIL CONN.
Not To Scale
EYE ANCHOR
5/8' ROD 48' LONG
WITH 6' HELIX
OR
5/8'ROD 60'LONG (SEE GROUND ANCHOR
WITH p HELIXSCHEDULE, SHEET 1 OF 6,
AS APPLICABLE FOR APPLICABILITY)
LANb�U.6F♦;TT
�ASE$AIL7+ND'$ECOREIGUF1.T �j'
TANCHOREYEWITH�1
EYE ANCHOR U (SEE GROUND ANCHOR
51W ROD 30' LONG SCHEDULE, SHEET 1 OF 6,
WITH DBL 4'HELIX .. - FOR APPLIDABIUTq
d-
�„1 BASE RAIL DEEP ANCHORAGE & BASE RAIL ANCHORAGE
Not To Scale Not To Scale
REVIEWED FOR
TS BOW RAFTER CODES COMPLIANCE 6'LONG TS NIPPLE
SECURE P. STe LUCIE COUNTWITH(4) 012-14 x3/4'P
ST TO N
NO SCREWS SDF's
�� ^ //11//�� REQUIRED C%OCC IN BOW BENDS r—F6'
4' 18 GA U-CHANNEL BRACE (5 TO T POST)
48' 18 GA U+CHANNEL BRACE (S TO 14' POST) TS RAFTER POST
BRACE ANGLE SHALL BE MIN. 45'
TO MAX. 60' FROM HORIZONTAL NIPPLETO 3/16'
BASE RAIL
TS CONTINUOUS BASE RAIL
r
6' LONG TS NIPPLE
—T SECURE RAFTER AND POST TO
fS ) NIPPLE WITH (4) #12-14 x 3/4-
RAFTER POST
SELF -DRILLING FASTENERS
R BOW RAFTER/POST DETAIL
NM To Scale
2' x 2' x 2' 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
HEADER, OR BOTTOM OF WINDOW
RAIUGIRT WITH (4) 012-14 x 3f4' SDPS
(2) ON TOP OR BOTTOM, (2) ON SIDE
TS WINDOW RAIL OR GIRT
FOR VERTICAL SIDING OPTION
NON-STRUCTURAL HEADER, WINDOW
RAIL, OR GIRT TO POST CONN. DETAIL
� Not To Scale
POST/BASE RAIL CONN. DETAIL
� NM TO Bale
I IIt//////
6BEE�0L ENGI • N AND TING; UiAt'__
DEUWD. FLORID`► 0•'' _
AAAuuu���t 3 _
�rtlfl� —_
Fimide nse'P.E/' O.� FLOFi�O.•'!��
111j)I 11W\ �
2'x2'x2' 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4) #12-14 x 314'
SDF's, (2) ON BOTTOM.
(2) ON SIDE
OR
2'x4. 16 GA PLATE
SECURE TO EACH SIDE OF
TS END POST POSTIRAFTER CONNECTION
WITH (4) #12.14 x 3W SDFs,
(2) ON POST, (2) ON RAFTER
� END POST/RAFTER CONN. DETAIL
Not To Spfe
1-11T x 1-1/2' x 2' 16 GA
CLIP ANGLE SECURE TO
RAFTER POST AND GABLE
RAIL WITH (4) #12-14 x 3/4' SDFs
(2) ON TOP, (2) ON SIDE
RAFTER POST
1-112' x 1-1/2' x 2' 16 GA CLIP
ANGLE SECURE TO RAFTER
AND GABLE RAIL WITH (4)
#12-14 x 3/4' SDFs, (2) ON TOP.
(2) ON BOTTOM
RAIL
GABLE RAIL TO RAFTER POST
�1 CONNECTION DETAIL
Naroswle
NIPPLE TC
DBL. HDR.
6' LONG TS NIPPLE
SECURE EACH WITH
(4) #12-14 x 3/4'
SELF -DRILLING FASTENERS
GA TS POST
tl�1 RAFTER POST/DBL. HEADER DETAIL
Not To Scale
1-1YC x 1-112' x 2 16 GA CLIP ANGLE
SECURE TO RAFTER POST AND
GABLE RAIL WITH (4) 012-14 x 3/4' ST
TOP AND BOTTOM i
1-1/2' x 1-1/2' x 2' 16 GA CLIP ANGLE
SECURE TO RAFTER AND GABLE
RAIL WITH (4) #12-14 x 314' SDFs,
(2) ON TOP, (2) ON BOTTOM
6' LONG TS NIPPLE
SECURE RAFTER AND POST
TO NIPPLE WITH (4) #12-14 x 314'
8' LONG TS NIPPLE
SECURE WITH (4) #12-14 x 3W
SELF -DRILLING FASTENERS
GA DOUBLE TS HEADER
NIPPLE TO
DBL. HDR.
�1 RAFTER POST/HEADER DETAIL
Not TO Scale
RAFTER
RAFTER 12' LONG TS NIPPLE.
SECURE POST TO NIPPLE
WITH (4) 012-14 x SW SDFs,
24- 16 GA U-CHANNEL BRACE IS TO T POST)
48- 16 GA U-CHANNEL BRACE (8' TO 14' POST)
GABLE RAIL BRACE ANGLE SHALL BE MIN- 45'
TO MAX. 60' FROM HORIZONTAL
—1,'�TS RAFTER POST
GABLE RAIL TO RAFTER POST
jR;CONNECTION DETAIL
I I� Not To Scale '
TS LEG
1-1/2' 18 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) #12-14 x 3/4' SDF TS
SPACED NOT MORE THAN 48' O.C.
2-1/4' FOR P6MG1 L METAL ROOF TS SAS
12 GA FRAMING
2-1/2' FOR
16 GAUGE U-CHANNEL BRACE
FASTENED TO THE POST AND
RAFTER WITH (2) #12-14 x 314' SDFS
AT EACH END (4 PER BRACE)
BRACE SECTION
Na To Scale
RAFTER
ROOF PANEL ATTACHMENT
(ALTERNATE FOR VERTICAL ROOF PANELS)
Not To Smle
NIPPLE
TH (4) 012-14 x 3/4' SDFs
RAFTER POST
SIDE EXTENSION
RAFTER/POST DETAIL
/� Net To Scale
TYPICAL FLOOD
VENT FRAMING PLAN
NOT TO SCALE
e' LONG TS NIPPLE
SECURE EACH WITH (4) #12-14 x 3/4'
SELF -DRILLING FASTENERS
GA TS POST
BASE RAIL
3M6' NIPPLE TO
BASE RAIL
RAFTER POST/BASE
( BSEACONNECTION DETAIL
2'x4' 16 GA PLATE (ONE REQUIRED)
SECURE TO EITHER SIDE OF
POSTIRAFTER CONNECTION
WITH (4) #12-14 x 3/4' SDFs,
(2) ON POST. (2) ON RAFTER
/TS LEAN-TO RAFTER
!' 16 GA ANGLE CLIP
tE TO POST AND
R WITH (4) #12-14 x 3/4'
(2) ON RAFTER,
POST
POST / LEAN-TO RAFTER CONN. DETAIL
Not To scale
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COS
SEE GENERAL NOTE No. 12, SHEET 1 OF 6.
®OCC
VERTICAL SIDE OPTION
GIRT
(Typica
SEE
TYPICAL END
WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN
NOT TO SCALE
;WINGING DOOR
)CTURAL HEADER 1-1Y2' 18 GAUGE FURRING CHANNEL FASTENED TO rOPENING FOR SWINGING DOOR
EACH RAFTER WITH FURRING
x 314' SELF -DRILLING 1 WITH NON-STRUCTURAL HEADER
6- FASTENER FASTENER SPACED NOT MORE THAN 48'O.C. /
GIRTS
(Typical)
BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL SIDES
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOT TO SCALE
lid
ICI—I�
I� ICI—�I�li
I �I
I�I�I�I�I�I®I��I�IiI�I
LENGTH
TYPICAL POST/RAFTER/GIRT FRAMING PLAN
NOT TO SCALE
BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL
TYPICAL SIDE ELEVATION
NOT TO SCALE
ROLL -UP DOOR
(As appficaNe)
TYPICAL END ELEVATION
NOT TO SCALE
OPENING FOR URA. I WI1H
NONSTRANO MDOWR R
ANOWINDOW aIs)
(Also oppf[ebleb EM WeYs)
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC