Evaluation Report M35710.12.10-R
FIEFCOPY FL14317-R10
COPY Date of issuance:12/21/2010
Revision 11:10/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida_ The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Boras Roof Underlayments
LABEuNs: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CcNnNUEO COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERnsEMENi: The Evaluation Report number preceded by the words "NEMO Ietc- Evaluated' may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site atthe request of the Building Official.
This.Evaluation Report consists of pages 1 through S.
Prepared by:
; ,."::.... ;,-
Robert J.M. Nieminen, P.E.
�,;��.;c=;,__,•
Thehaim'Iesealaypearingvraauthmzzed6yftoLert
Florida Registration No. 59166, Florida DC4 ANE1983
,i.:.:..',.:.^•'`
"Nieminen, P.Ean m/PJutls This does nocserve as an
ele=nimOy signed dowmsM
CERrrFiCAMON OF INOEPENOENCE:
L NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product
S. This is a buildingcode evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
Product Category:
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated
compliance with the following sections of the 601 Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
ice}
-i`S.x 6-I'4'ti'�^y {. 4. ¢- y�p�F"�.�.�'rg✓'Y - ,+.....+�T h-'ac 3 "c f.-. - :Y ? t�'dz �-�.:.i'�e+.r �n+'���X't€� ✓'^�... #E
Section
Property
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1S07-1.1, T1507-Y1,
Physical Properties
ASTM D1970
2015
1507-2.9.2
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
Enti
Examination
Reference
Date
ERD IT5T 6049)
Physical Properties
M36790.07.11
09/30/2011
ERD fTST 6049)
Physical Properties
B40380.08.12
08/28/2012
ERD(TST 6049)
Tensile Adhesion/LTA
C41420.09-12-2
09/12/2012
ERD(TST 6049)
Adhesion
B41940.09.12
09/13/2012
ERD(TST 6049)
Tensile Adhesion/LTA
B47390.07.14-1
07/31/2014
ERD(TST 6049)
Tensile Adhesion/LTA
B47390.09.14
09/04/2014
OC(PDM1838)
Physical Properties
Equivalency statement
11/02/2017
FRI (TSTS878)
ASTM D1970
NEI-031-02-02_11EV
10/27/2010
PRI (TST5878)
ASTM D1970
NEI-029-02-01:REV
12/03/2010
PRI (TST5878)
Tensile Adhesion/LTA
NEI-046-02-01REV
12/17/2010
PRI(TST5878)
FRSA/TRI April 2012
NEI-076-02-01
02/14/2011
PRI (TST5878)
ASTM D1970
NEI-034-02-02
01/29/2013
PRI (TST5878)
wind Uplift
80RR-001-02-01
03/17/2015
PRI (TST5878)
Wind Uplift
BORR-005-02-01
06/24/2015
PRIOV 5878)
Tensile Adhesion/LTA
DAPF-CO -02-01
03/08/2018
PRI W5878)
ASTM D1970 (adhesion)
OCF-443-02-01
10/21/2018
UL, U.C. (QUA 9625)
Quality Assurance
Service Confirmation
Exp. 08/21/2020
4.1 Boral® TfleSeal 50rrr is a nominal 50-mil thick, polyester -surfaced, self -adhering 5B5 modified bitumen roof
underlayment; meets ASTM D1970. -
4.2 BoralO T11eSeal' is a nominal 6D-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.3 Boral0 Metalseal"' is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment meets ASTM D1970 and FRSA/TRI 04-12.
4.4 GatorSeal° is a nominal SS -mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5 Citadel° Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970.
PJCPAO c i C, LLC Evaluation Report M35710.12_to.R31
CernfioleeofAodmraarfon832455 6n'EDMON(20171Fi3Ci101?};VHZEVAWATION FL4317-R1O
Boral Roof Underiaymentg (602) 269-mas Revision 1L• 10/12/2018
Page 2 of 8
z
�l, i�
j
nt z
�mm, ? JEil o y d etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically forthat purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
�i-
krx:
.�•��. _T3etaSv YQt �- .li bN.p.
+ "ri 1
.>� � 4"/
'Tt�i._T'f_Y�Y..+i�nT..��. ",2''��i '.�✓Se:.:r'
Under) ayment
Asphalt
Na--On Tile
Adhesive -set
Metal
Wood Shakes
Slate
Shingles
rile
&Shingles
Boral Til al 50ei
Yes
No
No
Yes
. Yes
Yes
- Boral TileSeal".�a
Yes
Yes
yes
Yes
Yes
Yes
-=-- `- .
(See 5.5.1)
Boral MetalSealef
Yes
Yes
yes
Yes
Yes
Yes
(See 55.1)
GatorSeal
Yes
No
No
No
Yes
Yes
5.5.1 "Adhesive -set Tile' is limited to use of following Approved tile adhesives / underlayment combinations.
-.L �. ��S.I�'�
.i! t:�'��•'i.-W'K
'S���y?A^.Y'G g�'..�v.�s 1-':.
Adhesive
Florida Product
Underlayments
Approval
DAP Foam Touch'n Seal StormBond Roof Tile Adhesive
FU4506
Boral TileSeaff or Boral MetalSealw
DAP Foam Touch'n Seal StormBond 2Two-Component
Polyurethane Roof Tile Adhesive
FL21374
Boral Tile5eal"r or Boral MetalSeal'tr
Dow TILE BONDTM Roof Tile Adhesive
FL22525
Boral TileSealnror Boral MetalSealM
ICP Adhesives Polysetn AH-160
FL5332
Boral TileSeainr or Boral MetalSealur
ICP Adhesives Polyset0 RTA-1
FL6276
Boral nleSeaff or Banal MetaLSeale
1 Refer to Tde Manufacturer's orAdhesive Manufacturer's Florida ProductApproval far Overturning Moment Resistance Performance.
NEN10 CIC, LLC Er Iwrtfon Report M35710.12.10-R11
QUoiliorteofAuthorhadon#32455 o°' EDIT10N (2017) FBC'!0N--VHZ EVALUAT1011 F1.14317-1370
Boraf Roof Underlayments; (602) 269-2288 Revision IL 10/12/2018
Page 5 of 8
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 5011r, Boral TileSeal" ; Boral MetalSealar or GatorSeal:
D Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSeal"r or Boral MetalSeal"r:
9 OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the
overlying roof cover is adhesive -set tile roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus, Boral TileSeal 50"; Boral T!IeSeal"r, Boral MetalSeal"r or GatorSeal:
B ASTM D226, Type 11 felt Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive-settile systems, base layershall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 50"r, Boral TileSeal" ; Boral MetalSeal"r or GatorSeal:
> ASTM D41 primed metal (e.g., flashing metal, valley metal, etc).
Boral TileSeal"r:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure = -120.0 post:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
lurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
CapSheec Boral TileSeal"rorBoral MetalSeai";self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga,1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure =-14Z5 psf:
Deck: Min- 15/324nch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet Boral TileSeal"r or Boral MetalSeal"r, self -adhered and hack -nailed within the selvedge -edge side laps
using 12 ga. x lY" ring shank nails through 32 ga,1-5/8" diametertin caps spaced 124nch o.c.
MEMO ETC, LLC evaluation Report M35710.12.10-R71
Ci frmteofAuthor&otien A3Z455 6'9Eon JWJ(2017) F8C M0i4-AVHZ e'1/ALUXHOi•! %i4317-F.10
-- -- - ---- -Boral Roof Underlaymentr (602) 269-2288— ------- --- Revision 11. 10/12/2018
Page 4 of 8
43 Maximum Design Pressure=-202.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer. Tropical Roofing Products #410 Quick Dry Primer or otherASfM D41 primer to the plywood deck
Base Ply: None
Cap Sheet Boral TileSeal"ror Boral MetalSeal"; self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x IY" ring shank nails through 32 ga, 1-5/8" diameter tin caps spaced 12-inch o.c.
94 Maximum Design Pressure=-210.0 cast
Deck: Min- 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK#89 Sta Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSealHrorBoral MetalSeal"r,self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diametertin caps spaced 12-inch o-c.
#5 Maximum Design Pressure = -220.0 osf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41tothe concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TileSealar or Boral MetalSealn self -adhered
5.6.4.1 Note: For adhesive -set file systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longerthan 30-days after installation, priorto placement of final roof cover.
Boral Trle5eal 50a ; Boral TileSealHr or Boral MetalSealH shall not be left exposed for longer than ISO -days after
installation, prior to placement of final roof cover.
Citadel Pius, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
ISO -days after installation, priorto placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations fFRSA/TRI April 2012 (04-1211:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum root slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
I Underlayment I Tile Profile I Staging Method I Maximum Slope I
Boral TrleSeal` or Flat Max 1D-tile stark 6:12
Boral MetalSeal'ir i Lugged Max lD-tile stack 6:12
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40`F and rising.
MEMO <=iC, LL C Evaluation Report M357LL3210-R31
0,rdfimW ofauthoriradon A32455 Fro EDA1011 (20i71 FaC id012-HV64 01AWATION i U43E7-RID
Boral Roof Underlaymentr, (602) 269-2288 Revision 11: 10/12/2018
Page 5 of a
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal mi"
Boral TileSeaIH1 or GatorSeal.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck-
Cut the membrane into manageable lengths, typically 10 to 12 fL Align the membrane parallel to the roof edge,
extending over by Y mch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch
diameter plastic orsteel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entirewidth of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct to -deck' instructions for Boral TileSeal 50" ; Boral
l ile5eal"r, Boral MetalSeaF or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Sara[ Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50"r, Boral
TileSeal"r or GatorSeal.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 Boral TileSeal 50" -
6.5.1 Shall be installed in compliance with the requirements for ASfM D1970 underlayment in FBC Table 1507.L1 for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"r on roof pitches less than 2:12.
6.53 Non -Tile Aoolications. Direct to Deck,
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by''/< -inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or I -inch diameter
plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
C emf 0LLC
Evaluation Report M35710.1L10-R11
@rtifiame ofN?Mrirptfoog32455 Sr"MMO (2017)FBI M0H-HNH2 EJAW.4YIOrQ M-4317-1116
Boral Roof Underlayments, (602) 269-2298 Revision M 10/12/7018
Page 6 of a
}
1
65.4 Non -Tile Applications. to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boras Roofing published installation instructions and Section 6.4.
Install 13oral TileSeal 50"r in accordance over ASTM D226, Type I I felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall he installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications. Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Y-inch. Fold the membrane away from the edge onto itself- Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the black -selvedge area, minimum 34nch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted SheetSeam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Baral Roofing published installation instructions and Section 6.4.
Install GatorSeal overASTM D226, Type 11 felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.7 BoralTileSeal"rorBoral MetalSeal"r:
6.7.1 Shall he installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral THeSeal n or Boral MetalSeal"r on roof pitches less than 2:12.
6.7.3 Non -Tile Applications. Direct to Deck:
For 05B substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by'Y inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch o.c Overlap successive courses the entire width of the black -selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEN40 FIC, ttC
Cero'fcaw ofAuthonzatm d32455 8nENTION 12917)FEC WON-HVHZ EVALUM1019
Boral Roof Underlayments (602) 269-2288
Evaluation Report M3SM-12.104131
F L43:7-RSC
ReuWon IL-10112/2018
Page7 of e
,�
6.7.4 Non Tile Aoplications to Base Sheet
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal" or Boral MetalSeal'n over ASTM D226, Type II felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.75 _Tile Aoolications-
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April2012 (04-12), Table L
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
Refer to Section 5.9 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal'ir
or Boral MetalSealar with roof pitches of 27/: to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
As required by the
this product
Brentwood, NH
UL, LLC.—QUA9625;
iaCiwo FrC, LLC
CcrdfJ=te ofAUUmnzo ym A3Z455
Official or Authority Having Jurisdiction in order to properly
546-2458; ':'anchi.A�rawela-Ce—
uLcom
- END OF EVALUATION REPORT -