HomeMy WebLinkAboutREG SPECS 6-8-20Bulletin LP-T R122H March 20''.i Type R122H First -Stage Regulator Introduction The Type R122H is an Underwriters Laboratories listed regulator designed for Trio -Stage LP -Gas systems. The unit is designed to reduce the tank pressure to an outlet pressure of 10 psig. The compact size makes it ideal for small domestic applications and underground tanks. The outlet pressure setting is nonadjustable and is factory set at a nominal 10 psig. Screened drip - lip vents are oriented over the outlet as standard. Features 20 Year Recommended Replacement Life - The R122H is designed using rugged time proven design concepts and constructed of corrosion resistant materials, both intemally and externally. With proper installation and periodic inspection and maintenance the R122H regulator will meet a 20 Year Recommended Replacement Life. • Dual Gauge Taps - Built-in 118 inch NPT gauge taps orificed to a number 54 drill size on both the inlet and outlet side of the regulator allow for easy testing. • Durability - A fluorocarbon valve disc is utilized to improve lockup performance in systems with contaminated gas. • Improved Regulation - A large fabric -reinforced diaphragm and stabilizer clip deliver accurate and stable regulation. • Easy Installation - The units compact size and easily accessible inlet and outlet wrench Flats make installation easy even in the tightest installations. FISHER Figure r. type R 122H Frtst-Stage Regulator Superior Overpressure Protection - The combination of a high capacity relief valve and large vent provide overpressure protection that exceeds UI_ standards When used in conjunction with a R622 or R652. the two -stage system will limit the downstream pressure from the second -stage to 2 psig even in a double failure situation. Corrosion -Resistant - Added corrosion resistance from an internal and external coating process for all castings prior to painting, stainless steel relief valve spring and retainer and a corrosion resistant relief valve seat. Positive Draining Spring Case - When installed properly with the spring case vent pointed down, the design allows moisture formed in the spring case to drain out limiting the problems with corrosion and freezing water in the spring case. EMERSON Process Management Bulletin LP-7: Toble 7. Ortleang lnf0nnelron TYPE NUMBER R122H-AAJ R122H CAPACITY MIHR PROPANEni q.000 CapapN o Ca3M m 30 P61G Rm Car) aJpl RRS51➢B arq ](roc mooP LP -Gas Equipment Emerson Process Management Regulator Teehnotegles. Ina USA - Headquarters h1rXmney. Tres 75089-1872 USA Telel`hc e 1 (80D)5585853 TelePhmle: 1 (972) 5483574 For fu",_ mtOmtaPOn -W w fisherregulat0 ,,r np CONNECTIONS INLET y OUTLET NOMINAL OUTLET SETTING lyd mm t l2 inm NPT 10 pag (0.69 earl rlgure 2. We R 122H Dimensr.ns Imm1 m.) Cimrma tl Emasm Ful= mart of Emnam Ekcm[ fA M a:rrcr mark+am ma pm{g0y ar ORa RRMaNre awrrers. FLSCar 0 a maR evakH W FRler CRNay, m[, a Reel artyarry tmn MIDg4 �mm0amap Cra DmCetlf Or aen+m 4¢wmMllaenm inea�apIDfdylM Wemxwalrta 0unt m 0myor may amVdffV aIM am MmCa mmC�pr yalrmVlmm d rarCaW salN+am oie error eb aabram, uta R mammnaara d arry Ra4ua. rnppye onmygy a yauyrAbe warm 7 fR Prryn adomm. iue and mamwiarvn yyA, Fngtim ��� °tp°�°""'9""�" Ra4WgR Te[ImplCpay, mc. fi0e. 1010. NI RNmC RavlVed E M ERSO N . Process Management Bulletin 71.1:R622 Type R622 Pressure Reducing Regulator • Compact Design • Prot( Scree June JO iO . ut,.1, n___CItY • Inlet and Outlet Pressure Gauge Taps Figure I. oN R622 Pleswe Reau� :rig Rngul.�fo. Relief Neight Introduction Type R622 direct -operated. spring -loaded regulators applications. These regulators can be used :,Ah provide economical pressure reducing control in natural. manufactured. or propane gases and have the a variety of residential. commercial. and industrial same inlet and outlet pressure capabilities. FISHER EMERSON. Bulletin 71.1: R622 if cations Body Size and End Connection Style() 1 /2 NPT inlet and outlet Maximum Allowable Inlet Pressure0) Operating: 125 psig (8,6 bar) Emergency: 125 psig (8,6 bar) Except 1.8 to 2.2-inches w.c. (4 to 5 mbar) spring range which has operating and emergency pressures of 60 psig (4,1 bar) Maximum Allowable Outlet (Casing) Pressure0) Operating to Avoid internal Part Damage: 3 psid (0.21 bar d) above outlet pressure setting Emergency: 20 psi (1.4 bar) Outlet Pressure Ranges See Table 1 Orifice Size 1/8-inch (3,2 mm) orifice Flow Coefficients Wide -Open C. for Relief Sizing: 12.5 Wide -Open C. for Relief Sizing: 0.36 Cl: 35 iEC Sizing Coefficients XT 0.78 Fp: 0.82 FL: 0.89 Flow Capacities See Table 2 Pressure Registration Internal Relief Performance See Figure 4 Internal Relief Performance Start -to -Discharge is 8 to 22-inches w.c. (20 to 55 mbar) for setpoints from 1.8 to 20-inches w.c. (4 to 50 mbar) Start -to -Discharge is 140 to 200% over setpoint from 20-inches w.c. to 2.2 psig (50 to 152 mbar) Spring Case Vent Connections 3/4 NPT with removable screen Temperature Capabilities() -200 to 160°F (-29° to 71 °C) Approximate Weight 2.35 pounds (1 kg) Construction Materials Body, Spring Case, Diaphragm Plate, and Orifice: Aluminum Diaphragm, Disk, and O-ring: Nitrile (NBR) Adjusting Screw and Pushpost: DelrinO Closing Cap: ASATherrnoplastic (UV -Ray Resistant) Control Spring: Zinc -plated steel Machine Screw, Spring Seat, and Lever: Zinc -plated steel Valve Stem: Zinc Relief Valve Spring, Relief Spring Retainer, Lever Pin, and Vent Screen: Stainless steel 1 Thag al UJAWN I U WAS in aft et em or any rye struaro won Iowa nw be exceeded. Oenaa to a =1 awned by E I. du Pan ee Nt'Mma Ind Co. In addition, Type R622 regulators have internal relief across the diaphragm to help minimize overpressure. Any outlet pressure above the start -to -discharge point of the non-adjustable relief valve spring moves the diaphragm off of the relief valve seat, allowing excess pressure to bleed out through the screened spring case vent. Table 1. Outlet Pressure Ranges Specifications The Speciftcabons section lists specifications for Type R622 Pressure Reducing Regulators. As it originally comes from the factory, specificcations for a given regulator are stamped on the spring case nameplate. OVTLEr PRESSURE RANGE CONTROL SPRING PART CONTROL SPRING SPRING WIRE DIAMETER. SPRING FREE LENGTH. NUMBER COLOR CODE INCHES (rem) INCHES (ntm) 18 to 2.24wMes w.c. (4 to 5 n bar) 5 tO 7-utChm we. (12 to 17 mbar) T 14453T0012 T 14398MO 12 Purple 00510.30) 3.40 (K4) 6.5 b 9�tndtes w.c (16 to 22 nnebar) T 14399TOO12 Orange Yie m 0.062 (1.58) 0.067 (1.70) 3.40 (86.4) 910134ndt es w.c. (22 to 32 ntbar) T 14400TOO t 2 Sam 0.072 (1.83) 3.61 (91.7) 13 to 204nsdtes w.c. (32 to 50 mbar) 16 to 35-Mc tes w.c. (40 to 87 mbar) T14401T0012 T 14402T0012 Gray 0.060 (2.03) 4.10 (104) 3.60 (91.4) 1 to 2.2 psig (69 to 152 mbar) T14403T0012 Pmk lkjP Blue 0 093 (2.36) 0 tOS (2.67) 3.52 (89.4) 3.66 (93.0)