Product Report
EXTREME METAL FABRICATORS,LLC
1.0"Nailstrip.032"Aluminum over Min.15/32"4-Ply CDX Plywood
Florida Product Approval#
Florida Building Code 2017
Per Rule 61G20-3
Method:1-D
Category: Roofing
Subcategory:Metal Roofing
Compliance Method:61G20-3.005(1)(d)
WITH SEALANT:HVHZ
WITHOUT SEALANT: NON-HVHZ
Product Manufacturer:
Extreme Metal Fabricators LLC
2160 5W Poma Drive t.
Palm City, FL 34990 l�
I I VIIJ V
Engineer Evaluator: �+` p. Q r*i
Locke Bowden,P.E.#49704 ��Oti~N Si •.•/�i
9450 Alysbury Place �. • �%
Montgomery,AL 36117 N0' Ag704 '
Valldator: STATE OF %�
Diane G. Marrotta,P.E.#82591
1915 NE 451h St.#107 '` '••••'
Fort Lauderdale, FL 3330$ 'frjoSS/O+NA y +++�
Contents:
Product Report
Certificate of Independence:
Locke Bowden,P.E.does not have,nor will acquire a financial interest in any company manufacturing or distributing products under
this evaluation.
Locke Bowden,P.E.is not owned,operated,or controlled by any company,manufacturer or distributing products under report.
FL#
PRODUCT REPORT
FLORIDA PRODUCT APPROVAL
FLORIDA BUILDING CODE 2017
ZZZ4S*!%4k
EXTREME METAL.
FABRICATORS
1.0 Nailstrip .032" Aluminum WITHOUT SEALANT
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017,Sections 1504.3.2, 1518.9, 1523.6.5.2.4
Product Description: 1.0" Nailstrip .032"Aluminum Roofing Panel
Panel Material/Standards: .032 Aluminum 0.028" MIN. To be in compliance with FBC 2017 Section
1507.4.3 Corrosion Resistant. Paint Finish (with approval)Optional
Panel Dimension(s): As Tested: 16" Coverage Width
Fastener: #10 x 1" panclip fastener through the nailstrip leg of the panel spaced 6"O.C.
Fastener goes through the nail strip panel and not the pre-existing nailstrip
slots.
The female leg of the panels snap-fit to the male leg of the adjacent panels.
Moisture Barrier: Boral TileSeal—Self-adhered to the plywood roof deck.
30#Asphalt saturated organic A single layer was used with a 4"overlap between adjacent sheets.
felt paper: Attachment—0.120"x 1-1/4"galvanized annular ring shank roofing nails with
32GA tin caps spaced 6"o.c. at perimeter and overlaps,w/2 intermediate rows
spaced 6"o.c.
Fire Barrier: A single layer was used with a 4"overlap between adjacent sheets.
Substrate Description: 15/32"4-Ply CDX Plywood Sheathing
Attachment—use 8d coated ring shank nails spaced 4"o.c.over supports at 24"
o.c. maximum.
Design Uplift Pressures: -168.5 PSF spaced @ 6" O.C.
FL#
PRODUCT REPORT
FLORIDA PRODUCT APPROVAL
FLORIDA BUILDING CODE 2017
ZZZ4S*!%4k
= Ne E METAL
_ - —FABRICATORS
1.0 Nailstrip .032" Aluminum WITH SEALANT
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017,Sections 1504.3.2, 1518.9, 1523.6.5.2.4
Product Description: 1.0" Nailstrip .032"Aluminum Roofing Panel
Panel Material/Standards: .032 Aluminum 0.028" MIN. To be in compliance with FBC 2017 Section
1507.4.3 Corrosion Resistant. Paint Finish (with approval)Optional
Panel Dimension(s): As Tested: 16" Coverage Width
Fastener: #10 x 1" panclip fastener through the nailstrip leg of the panel spaced 6"O.C.
Fastener goes through the nail strip panel and not the pre-existing nailstrip
slots.
The female leg of the panels snap-fit to the male leg of the adjacent panels.
Sealant: Geocel 2320 Sealant—A continuous bead was used @ the nailstrip side of the
seam.
30#Asphalt saturated organic A single layer was used with a 4"overlap between adjacent sheets.
felt paper: Attachment—0.120"x 1-1/4"galvanized annular ring shank roofing nails with
32GA tin caps spaced 6"o.c. at perimeter and overlaps,w/2 intermediate rows
spaced 6"o.c.
Fire Barrier: A single layer was used with a 4"overlap between adjacent sheets.
Substrate Description: 15/32"4-Ply CDX Plywood Sheathing
Attachment—use 8d coated ring shank nails spaced 4"o.c.over supports at 24"
o.c. maximum.
Design Uplift Pressures: -175 PSF spaced @ 6"o.c.
FL#
PRODUCT REPORT
FLORIDA PRODUCT APPROVAL
FLORIDA BUILDING CODE 2017
ZZZ4S*!%4k
= `r1W E METAL
�FABRIGATORB
Code Compliance: The product herein has demonstrated compliance with the Florida Building
Code 2017,Sections 1504.3.2, 1518.9, 1523.6.5.2.4
Product Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017,as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
Reference Data: Testing: UL 580-06 Tests for Uplift Resistance of Roof Assemblies
Test Lab: Intertek-ATI Report#: G1195.09-450-44 Dated: 08/12/16
Testing: TAS125-03 Standard Requirements for Metal Roofing
Test Lab: Intertek-ATI Report#: G3443.36-450-44 Dated:08/12/16
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005(3)for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section
1515.2 and in accordance with manufacturer's recommendations.
Installation: Install per manufacturer's recommended details.
Underlayment: Shall comply with Florida Building Code 2017 Section 1507,Table 1507.1.1
Roof Panel Fire Classification: Any approved fire barrier having a current NOA. Fire classification is not part of
this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
Design Procedure: For roofs within the parameters listed on the load table,fastening pattern must
at a minimum meet those listed for the applicable wind zone. For all roofs
outside the parameters listed on the load table,design wind loads shall be
determined for each project in accordance with FBC 2017 Section 1609 or ASCE
7-10 using allowable stress design. The maximum fastener spacing listed herein
shall not be exceeded.
ZONE HIP ROOF ZONE3 Note: Dimension [a] is defined as 10%of the minimum width of the
a
building or as 40%of the mean height of the roof,whichever is
RIDGE
smaller.
` ZONE 7 Note: [a] cannot be less than either 4%of the minimum width of
the building or three [3] feet.
EAVE
ZONE Z GABLE ROOF `
RIDGE
ZONE 7
ZONE 3 ' EAVE
FL#
PRODUCT REPORT
Extreme Metal Fabricators— Min. .032" Aluminum 1.0 Nail Strip Panel
16" Wide Panel WITH SEALANT
Installation Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code(FBC)2017 6T"ed..see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed.,and per with Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6.Support framing in compliance w/FBC 2017 6"ed.,Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
PROFILE
I
1-1/2"
I
FASTENER PATTERN ALONG VERTICAL SEAM:
FASTENED @ 6" O.C.
16" O.C.
Continuous
bead of Geocel
2320 sealant
Extreme Metal Fabricators — Min. .032" Aluminum 1.0 Nail Strip Panel
16" Wide Panel WITHOUT SEALANT
Installation Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6T"ed.. see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed.,and per with Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed.,Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7.This report does not imply warranty, installation, recommended product use outside of this report.
PROFILE
16" ►
2"
FASTENER PATTERN ALONG VERTICAL SEAM:
FASTENED a@ 6" O.C.
• 16" O.C. ►