HomeMy WebLinkAboutspeaker box Popeys►i -INK7 i'i i! ►00000000 I►i'i'i'i'i'i'i'i' NOTES: CABINET AND CONNECTION DESIGN BY OTHERS. ELECTRICAL DESIGN BY OTHERS. SPEAKERBOX 3/8"DIA.x12" LONG ANCHOR BOLT GRADE e V (4) #4 BARS ON A 11" PATTERN WITH (5) #3 STIRRUPS ON 5" CENTERS DO NOT WELD REBAR. OVER TURN [-8 3/16"— ° ° PLACE ORDER HERE 4. d. as Id e 1'-6" DIA.- •16 CU. YDS. OF 1'-6" DIA.� CONCRETE REQ'D ELEVATION SIDE VIEW TUROVER N ANCHOR BOLT PROJECTION DETAIL Q b �• �•• Z e d ° A. LLI d' 2.• a n • ' OH • •ic• is a = . SECTION @ CAISSON r3/8"DIA.x12" LONG ANCHOR BOLT 1 1/2"x1 1/2"x3/16" ALUMINUM ANGLE, TYP. HIGH -STRENGTH, NON -SHRINK GROUT I I STIRRUP HOOK, TYP. L'11 3/8" HEAVY HEX NUT C L - 3/8"DIA.x12" LONG ANCHOR BOLT 3/8" HEAVY r_[��HEX NUT TACK TYP. ANCHOR BOLT DETAIL � or ,ia. rer °npvp� alMr 9,m n,. horded did w , +.read Me erWm m..d iaoc Engines by owe... ar POP EYE S a da ft of `° "d°"°° 4946 SOUTH 25TH ST. ]MAD N. KASHIF, P.E. FORT PIERCE, FL 34981 FLORIDA STATE LICENSE NO.: 41374 CLIENT: 14902 SOMMERMEYER ST l4 [��O SUITE 120 pa 000p0 () Gn hic oo� Pe°°�� C E NSF°°°°y°00 5°'°i°^� HOUSTON, TX 77041 o o ° a No. 41374 0 o LINK Engineering, L.L.C. 0 0 o° o L 135 South David Lane • Knoxville, Tennessee 37922 o � STATE OF ° o 77 fT Phone: (865) 539-4001 • Fax: (865) 539-0851 o o go Online: www.linkengr.Com � p�o F Q, °° �p Florida State Cartificate of Authorization No.: 27148 0 0p OR > 0 ; ��DO SHT. BY: Project Number. S °°°°°°aa°°°�C� 000� 1 GHK 20-0305 pO00pApOppO \ OF DATE: Drawing Number. 2 5/11/20 B189O57 Z W lY O P O I — PROJECT# 20-0305 OWNER POPEYES May 11, 2020 4946 SOUTH 25TH ST. DRAWING # B189057 FORT PIERCE FL 34981 1/2"x3/16" VNNDLOAD 40.15 PSF ANGLE, TYP. WIND SPEED 160 MPH ' CLIENT LSIGRAPHIC SOLUTIONS PLUS # COLUMNS 1 Florida Budding Code 14902 SONIdERMEYER ST, STE #120 HOLE, DESIGNER GHK 6th Ed. (2017) HOUSTON, TX SHAPE ' CENTROID TOTAL ITEM ' HEIGHT ' VNDTH ' FACTOR HEIGHT AREA ' FORCE MOMENT SPEAKER 3 917 0 682 1 000 2.15 2.672 0.107 0231 OAH 3.917 BOLT CALCULATIONS BOLT BOLTS/ TENSION/ BOLT ALLOW. ALLOWABLE ITEM MOMENT SPACING PLATE BOLT DIAM1 STRESS TENSION BASE PL. 0.231 6 000 6 000 0.154 0.375 19.100 2.110 TYP. ANCHOR BOLT LOCATION DETAIL General Notes: 1, Design is based on a 160 mph, 3 second gust wind design per Florida Building Code 6th. Ed. (2017). Category 11, Exposure C. 2. Caisson foundation is based on a presumptive safe lateral soil bearing pressure minimum of 150 psf per foot of depth. Isolated lateral bearing footings subject to short—term lateral loads and not adversely affected by a 1/2" motion at grade are permitted to be designed using twice the tabulated value of the corresponding soil class. 3. A soil report was not provided. Foundation analysis assumes Soil Classification 4. Allowable bearing pressure should be verified prior to placement of concrete. In the event that the stated requirements are not met and conditions appear deleterious, cease and secure excavation and immediately contact LSI GRAPHIC SOLUTIONS. 4. Foundation shall not be placed at the top of, or on the side of a slope exceeding 3:1, or adjacent to a fill slope unless re—evaluated by a competent Professional Engineer. Do not place foundation in fill. 5. Concrete shall be mixed to attain a minimum 28 day compressive strength of 2500 psi. 6. Steel reinforcing bars shall conform to ASTM A615, Grade 60 with deformations in accordance with ASTM A305. Welding of reinforcing bars is prohibited. 7. All voids between column base plate and foundation surface shall be completely filled with high —strength, non —shrink grout. 8. Anchor bolts shall meet ASTM F1554 Grade 36. Exposed surfaces shall be galvanized or coated to prevent corrosion. 9. All support members shall be free from defects. Aluminum extrusions shall be 6063—T6 alloy. Aluminum plates shall be 5052—H34 alloy. Aluminum sheet shall be 3003—H14 alloy. 10. Aluminum welds shall be made with 5356 filler by persons qualified in accordance with AWS standards within the past two years. 11. All structural bolts shall conform to ASTM A307, and be zinc coated unless noted otherwise. When used with structural bolts, heavy hex nuts shall conform to ASTM A563, and washers shall conform to ASTM F436. Pretension all high strength bolts using the Turn —of —Nut method unless noted otherwise. 12. The scope of this engineer does not include onsite observations. 13. LINK Engineering will not be responsible for the safety on this job site before, during or after installation of this structure. It is the responsibility of the owners, contractors and installers to ensure that the installation and erection of this structure is performed using methods that are in full compliance with OSHA regulations. 14. Any deviation from this design or from any part of this drawing, including the General Notes, without prior written consent from LINK Engineering voids this drawing in its entirety. 15. The structure designed on this drawing is intended to be installed at the address shown and should not be used at any other location. PLATE CALCULATIONS ITEM TENSION MOM94T MOMENT PLATE PLATE PLATE MINIMUM BOLT ARM PLATE WIDTH DEPTH THICK. THICK BASE PL. 0 154 0.688 0.106 2 313 1 000 0.125 0.101 ANCHOR BOLT PROJECTION ANCHOR EMBEDMENT ANCHOR BOLT MIN LENGTH 2.000 0,817 3.000 CAISSON MOMENT 0.231 FT -KIP FORCE 0.107 KIP REFERENCE BC 1807.32 & TABLE 1806.2 ASSUME SOL CLASS #4 SW, SP, SM, SC, GM & GC LATERAL BEARING PRESSURE- PSFIFT OF DEPTH 150.0 PSFIFT S1 250.0 DEPTH 2 500 FT. DIAMETER 1500 FT. 2.154 FT. 0.670 FT. CA LCULATED DEPTH 1.633 FT. MINIMUM THICKNESS WITHOUT REINFORCEMENT 8.345 IN. ACTUAL DIAMETER 18.000 IN. CONCRETE 0.164 CU. YD. m INSTALLATION ADDRESS: LNC Fiig6ai4 LL0. onabed y fcr 1ba protect. UN of tM dMi" w pkr- for my oQW aloe un &A ba , prdmitai tfdwek tm a eonemt of uw DO—V4 LLG Dyyo�a of POPEYE S my of 1* hbaama as �` � d a� `o 4946 SOUTH 25TH ST. of ud properly °ed Yid not be U af.a IMAD N. KASHIr, P.E. FORT PIERCE, FL 34981 FLORIDA STATE LICENSE NO.: 41374 o��Po ��CENSF °°� I O \ o e p = o o° No. 41374 °°o o o a o 0 o °°o STATE OF o°° o O 0'� °° F� 0 R 0 P oo°OO00000°°° P ° 000000000 uo oa9aua 0 %%" S� 14902 SOMMERMEYER ST SUITE 12D Graphic HOUSTON, TX 77041 Soluteoa. LINK Engineering, L.L.C. L l 135 South David Lane • Knoxville, Tennessee 37922 Phone: (865) 539-4001 • Fax: (865) 539-0851 Online: www.linkengr.com Florida State Certificate of Authorization No.: 2714E HT. BY: Project Number. 2 GHK 20-0305 2 1 DATE: Drawing Number.. 5/11/20 1 B189057