HomeMy WebLinkAboutEnergy Codet( FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WATERSTONE LOT-57 Builder Name: K. HOVNANIAN Street: 00 517-1 APfWr4L?I91, Permit Office: ST. LUCIE� City, State, Zip: FT. PIERCE, FL, 34951 ,C,.O�,Ur`NTY Permit Number: ;Ivv4 - 05-A Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1716.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1450.20 ft2 b. Frame - Wood, Adjacent R=11.0 265.78 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 10. Ceiling Types (1616.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1616.00 ft2 6. Conditioned floor area above grade (ft2) 1616 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(163.6 sqft.) Description Area a. Sup: Attic, Rel: Attic, AH: Main 6 448 a. U-Factor. Dbl, U=0.32 106.11 ft2 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.55 41.00 ft2 12. Cooling systems kBtuthr Efficiency SHGC: SHGC=0.34 a. Central Unit 28.8 SEER:14.00 c. U-Factor: Dbl, U=0.32 16.44 R2 SHGC: SHGC=0.27 13. Heating systems kBtuthr Efficiency d. U-Factor. N/A ft2 a. Electric Heat Pump 28.8 HSPF:8.60 SHGC: Area Weighted Average Overhang Depth: 4.626 ft. Area Weighted Average SHGC: 0.307 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1616.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1616.00 R2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.101 Total Proposed Modified Loads: 53.60 PASS Total Baseline Loads: 57.63 1 hereby certify that the plans and specifications covered by Review of the plans and OF-flliE SpglF this calculation are in comDliance with the Florida Energy specifications covered by this indicates IV Code. ^ A calculation compliance with the Florida Energy Code. 1, non+�`.� •..;r..•?;�„`°�„ � PREPARED BY: Before construction is completed a 161 O DATE: 5/8/2020 this building will be inspected for compliance with Section 553.908 _ A . s 1 ¢ I hereby certify that this building s^designed, is in compliance Florida Statutes. with the Florida Energy-Ge COD {yFi'C�J OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). Me G°VY 5/7/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 1 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: WATERSTONE LOT-57 Bedrooms: 4 User Conditioned Area: 1616 Total Stories: 1 1 Worst Case: No K HOVNANIAN Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 5T- Block/Subdivision: PlatBook: Street: TBD County: St. Lucie City, State, Zip: FT. PIERCE, FL. 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1616 14059.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1616 14059.2 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpel 1 Slab -On -Grade Edge Insulatio Main 167.2 ft 1616 ft' -- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1750 ft' 0 ft' Medium N 0.4 N 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1616 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frec Truss Type 1 Under Attic (Vented) Main 30 Blown 1616 ft2 0.1 Wood 5/7/2020 4:18 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w _ 1 -2 _ 3 -4 5 S E N W - Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block - Ext Insul Main Exterior Concrete Block- Ext Insul Main Garage Frame - Wood Main 4.1 52 0 8 4.1 16 4 8 4A 64 0 8 4.1 35 0 8 11 30 8 8 8 450.7 it- 8 141.6 ft2 8 554.7 ft2 8 303.3 ft2 8 265.8 f12 0 0 0.3 0 0 0.3 0 0 0.3 0 0 0.3 0 0.25 0.3 0 0 0 0 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 E Wood Main None .39 3 7 21 112 WINDOWS Orientation shown Is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 S 1 Vinyl Double (Clear) Yes E 2 Vinyl Double (Clear) Yes N 3 Vinyl Double (Clear) Yes N 3 Vinyl Double (Clear) Yes W 4 Vinyl Double (Clear) Yes W 4 Vinyl Double (Clear) Yes 0.32 0.3 N 0.32 0.27 N 0.32 0.3 N 0.55 0.34 N 0.32 0.3 N 0.32 0.3 N 15.0 ft2 1 ft 0 in 16.4 ft2 1 ft 0 in 16.4 ft2 1 ft 0 in 41.0 ft2 10 It 0 in 49.8 112 1 it 0 In 24.9 ft2 10 ft 0 in 1 ft 0 in None 1 ft 0 in None 1 It 0 in None 1 ft 0 in None 1 ft 0 in None 1 ft 0 in None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 380 ft2 380 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000387 1640.2 90.05 169.35 .1387 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pumpl Split HSPF:8.6 28.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14 28.8 kBtu/hr cfm 0.7 1 sys#1 5/7/2020 4:18 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / —Supply— —Return Air CFM25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heal Cool 1 Attic 6 448 it' Attic 212 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabl[e CFans: ]Thermostart:'JY Heating tX1 Jan Feb jj jj IX] Mar Apreiling Apr MayjX] May Jun ) Jul [X] [ ] Aug j j Sep Oct N Oct Nov Dec Venting II 11 Jan [ 1 Feb l l II�R1l Mar [ Lxl Jun 1 Jul E [ 1 Aug EX] 1 Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 it 0.3 Main 5/7/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 28.8 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER .1 c) Groundwater source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1616 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.378 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.307 14. Heating system: Capacity 28.8 c) Area 7c. 163.6 a) Split system heat pump HSPF 8.6 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 1081. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based oryigstalled code compliant features. Builder Signature: Date: 5-t2--s0 Address of New Home: AW SDI Aywru- f We' City/FL Zip: FT. PIERCE, FL 34951 5/7/2020 4:19:06 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Ml Aywhiro, qlt� Permit Number: pg$fi' FT. PIERCE, FL, 34951 MANDATORY REQUIREMENTS See individual code sections for full details. FA SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveldl6�_ building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. ❑ R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the Intended weatherstripping or other infiltration control measures. 2. Dampers Including exhaust, intake, makeup air, backdra0 and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if Installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have fight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakagdNindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 5/7/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 • MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel-buming appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filler boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNETACC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes, to be 'substantially leak free' in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturers designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in lest: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturers air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstmction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturers air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying Fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R-3. ElR403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The contmis shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ElR403.5.1.2 Heat trace systems. Electric heal trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 5/7/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps (Mandatory). Storage water healers not equipped with integral heat traps and having vertical pipe risers shall have heal traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 % inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100'F to 140°F (38'C to 60'C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. FJ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ri R403.6.1 Whole -house mechanical ventilation system fan efficacy.When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). FJ R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement healing and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cm/waft <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cm = 28.3 L/min. a. When tested in accordance with HVI Standard 916 5/7/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that Its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ElR403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. El integral Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool healing systems. 3. Where pumps are powered exclusively from on -site renewable generation. El the Covers. Outdoor healed swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 5/7/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (Mandato fte energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 5/7/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WATERRSTOLN,E'L'OT-57 Builder Name: K. HOVNANIAN Street: j{o al r•f m•Ylp-��Q Permit Office: ST. LUCIE C UNTY City, Stale, Zip: FT. PIERCE, FL, 34951 Permit Number: 11,003-05��' U Owner: Jurisdiction: W x Design Location: FL, Fort Pierce � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the lop of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the lop of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided Instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air fight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pining an wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover nlates and wails or milinas. a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400. 5/7/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: ollicv3-p5lq Job Information Builder: K. HOVNANIAN Community: Lot: Address: M 5= AiYronw tj&M City: FT. PIERCE State: FL Zip: 34951 Air L'eakageTestR'esults Passing results must meet eitherthePerformance, Prescriptive, orERI Method O' PRESCRIPTIVE METHOD' -The building ordwelling unit shall be tested and verified as having an air leakage rate of not exceeding air changes per hour at a pressure of 0:2 inch w.g. (501Pascals) in Climate Zdnesl and 2_ PERFORMANCE or ERI METHOD;Thel.buildmg or dwelling unit shall be tested and verified as.tiaving art air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405 2017 (Performance).. orR406 2017,(ERI), section labeled as infiltration, sub -section ACH50. ACH(50). specified on Form R405-2017-Energy Calc,(Performance) or R406-2017(ERI): Z000 x 60 14059 — Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans 1-1 PASS Code • software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at anytime after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 5/7/2020 4:19:39 PM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FSC 6th Edition (2017) Compliant Software Page 1 of 1 LoaJob: d Short Form -P�1- wrightsoft* Date: May 4, zozo Entire House ey: For: WATERSTONE LOT-57 TBD, FT. PIERCE, FL 34951 Htg CIg Outside db (°F) 43 91 Inside db(°F) 70 75 Design TO (°F) 27 16 Daily range - L Inside humidity (%) 40 50 Moisture difference (gr/lb) 11 59 Method Construction quality Fireplaces Infiltration Simplified Semi -fight 0 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A* Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling 20160 Btuh Heating output 28000 Btuh @ 47°F Latent cooling 8640 Btuh Temperature rise 27 OF Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.68 ROOM NAME Area (ft) Htg load (Btuh) CIg load (Btuh) Htg AVF (cfm) CIg AVF (cfm) OWNERS SUITE 178 2811 3700 141 161 DININGAREA 147 2751 3455 138 150 GREAT ROOM 219 2849 3242 143 141 BEDROOM 4 150 1546 1629 78 71 KITCHEN 145 143 1709 7 74 OS BATH 60 60 239 3 10 OS WIC 64 1048 651 53 28 FOYER 151 978 813 49 35 MECH 17 17 389 1 17 HALL BATH 79 1034 493 52 21 BEDROOM 3 168 3852 3097 193 134 LAUNDRY 51 50 812 3 35 BEDROOM 2 147 1764 1720 89 75 „—f„w, i nn ne9 A.I *4 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t + WrightSOft* Right -Suite® Universal 201212.1.05 RSU02818 ACChC:\Users\Jason\Documents\WrightsoftHVAC\WATERSTONELOT-57.rup Calc=MJ8 Front Door faces: E 2020-May-07 14:45:37 Page 1 Entire House 1607 19119 22112 960 960 Other equip loads 0 0 Equip. @ 0.95 RSM 21117 Latent cooling 10239 I 1 1 1 1 OTALS luut 19199 31000 960 960 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-071 ' 37 wrightWf ' Right -Suite® U niversal 201212.1.05 RSU02818 P ge 2 leak C:\UsemUason\Dcwmenls\Wrightsoft WAC\WATERSTONE LOT-57.mp Cale =MJS Front Door faces: E Project Summary Date: May 4, 2020 P�- wrightsoft° Entire House By: For: WATERSTONE LOT-57 TBD, FT. PIERCE, FL 34951 Notes: Weather: Vero Beach Municipal AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TO 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16698 Btuh Structure 18029 Btuh Ducts 2421 Btuh Ducts 4083 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19119 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 21117 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 9151 Btuh Ducts 1088 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft� 1607 1607 Equipment latent load 10239 Btuh Volume (f 3) 13984 13984 Air changes/hour 0.26 0.14 Equipment total load 31356 Btuh Equiv. AVF (cfm) 61 33 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A' Cord GSZ140301A' AHRI ref 4888616 Coil AR*F193116C' AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling 20160 Btuh Heating output 28000 Btuh @ 470F Latent cooling 8640 Btuh Temperature rise 27 OF Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.68 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. witi hisoft- 2020-May-07 14:45:e .t 9 Righl-Suile®Univ ersa1201212.1.05 RSU02810 ��` Pagel I C:\Usenwason\Documents\Wrightsoft HVAC\WATERSTONE LOT-57.rup Cale=MJS Front Door faces: E