Loading...
HomeMy WebLinkAboutGeotechnical Exploration Report1215 Wallace Drive • Delray Beach, Florida 33444 • (561) 347-0070 • (561) 347-0809 (fax) • www.teamgfa.com OFFICES THROUGHOUT FLORIDA GFA INTERNATIONAL FLORIDA’S LEADING ENGINEERING SOURCE Geotechnical Exploration Report Lot A-3 Residence 10751 South Ocean Drive, Jensen Beach, Florida March 16, 2020 GFA Project No. 20-8566.00 Prepared for: JWN Builders, LLC Since 1988 Florida’s Leading Engineering Source Environmental • Geotechnical • Construction Materials Testing • Threshold and Special Inspections • Plan Review & Code Compliance March 16, 2020 Mr. James Newman JWN Builders, LLC 1701 SE Carvalho Street Port St. Lucie, Florida 34983 RE: Geotechnical Exploration Report Lot A-3 Residence 10751 South Ocean Drive, Jensen Beach, Florida GFA Project No. 20-8566.00 Dear Mr. Newman: GFA International, Inc. (GFA) has completed the subsurface exploration and geotechnical engineering evaluation for the above referenced project in accordance with the geotechnical and engineering service agreement for this project. The scope of services was completed in accordance with our Geotechnical Engineering Proposal No. 20-8566.00 dated February 7, 2020, planned in conjunction with and authorized by you. EXECUTIVE SUMMARY The purpose of our subsurface exploration was to classify the nature of the subsurface soils and general geomorphic conditions at the site and evaluate their impact upon the proposed construction. This report contains the results of our subsurface exploration and our engineering interpretations of these with respect to the project characteristics described to us, including providing recommendations for foundation design and site preparation. Per our prior telephone discussions and email correspondence with you, GFA understands the project consists of a new single-story residence located at 10751 South Ocean Drive (Lot A-3) in Jensen Beach, Florida. At this time, no site or house plans are available. Specific design loads have not been provided to GFA. For the foundation recommendations presented in this report, we assumed a maximum wall loading of 3 kips per linear foot and a maximum column load of 35 kips. The recommendations provided herein are based upon the above considerations. If the stated conditions are incorrect or if the project description is revised, please inform GFA so that we may review our recommendations with respect to any modifications. Two (2) standard penetration test (SPT) borings, advanced to an approximate depth of 15 feet below the existing ground surface, were completed for this study. The subsurface soil conditions encountered at the boring locations generally consisted of alternating layers of very loose to dense fine sand (SP) containing varying amounts of shell to the boring termination depths. Lot A-3 Residence Geotechnical Exploration Report 10751 S Ocean Drive, Jensen Beach, Florida March 16, 2020 GFA Project No.: 20-8566.00 Considering the results of our field exploration program, the subsurface soil conditions at the project site are generally favorable for support of the proposed structure on shallow foundations. A maximum allowable soil bearing pressure of 2,500 psf may be used for foundation design. The subgrade soils should be improved (densified) with compaction from the stripped grade prior to constructing the building pad. Prior to placing fill to achieve final grade, the upper 2 feet of soil below stripped grade should be compacted to a minimum of 95 percent maximum dry density as determined by the modified Proctor test (ASTM D 1557). Fill (including stem wall backfill) should be placed in 12-inch thick lifts and compacted to achieve a minimum 95 percent modified Proctor maximum dry density. After completing the footing excavations, the bearing subgrade to a depth of 2 feet should be compacted to not less than 95 percent modified Proctor maximum dry density. We appreciate the opportunity to be of service to you during this phase of the project and look forward to a continued association. Please do not hesitate to contact us if you have any questions or comments, or if we may further assist you as your plans proceed. Respectfully Submitted, GFA International, Inc. Florida Certificate of Authorization No. 4930 This item has been digitally signed and sealed by John Kent, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. John Kent, P.E. Khaled Abdelli Senior Project Engineer Project Manager Florida Registration No. 63218 Distribution: Mr. James Newman – JWN Builders, LLC 1 pdf TABLE OF CONTENTS 1.0 INTRODUTION ...............................................................................................................................................1 1.1 SCOPE OF SERVICES .......................................................................................................................................1 1.2 PROJECT DESCRIPTION ...................................................................................................................................1 2.0 OBSERVATIONS ...........................................................................................................................................1 2.1 SITE DESCRIPTION ..........................................................................................................................................1 2.2 FIELD EXPLORATION ........................................................................................................................................1 2.3 VISUAL CLASSIFICATION ..................................................................................................................................2 2.4 GEOMORPHIC CONDITIONS ..............................................................................................................................2 2.5 HYDROGEOLOGICAL CONDITIONS .....................................................................................................................3 3.0 ENGINEERING EVALUATION AND PRELIMINARY RECOMMENDATIONS ............................................3 3.1 GENERAL ........................................................................................................................................................3 3.2 SITE PREPARATION .........................................................................................................................................3 3.3 VIBRATION MONITORING ..................................................................................................................................4 3.4 DESIGN OF FOOTINGS......................................................................................................................................4 3.5 SETTLEMENT ESTIMATES .................................................................................................................................5 3.6 GROUND FLOOR SLABS ...................................................................................................................................5 4.0 REPORT LIMITATIONS .................................................................................................................................6 5.0 BASIS FOR RECOMMENDATIONS .............................................................................................................6 Appendices Appendix A - Vicinity Map Appendix B - Test Location Plan Appendix C - Notes Related to Boring Records Appendix D - Log of Boring Records Appendix E - Discussion of Soil Groups Lot A-3 Residence Geotechnical Exploration Report 10751 S Ocean Boulevard, Jensen Beach, Florida March 16, 2020 GFA Project No.: 20-8566.00 Page 1 of 6 1.0 INTRODUTION 1.1 Scope of Services The objective of our geotechnical services was to collect subsurface data for the subject project, summarize the test results, and discuss any apparent site conditions that may have geotechnical significance for building construction. The following scope of services is provided within this report: 1. Prepare boring logs depicting the subsurface soil conditions encountered during our field exploration. 2. Review the soil samples obtained during our field exploration for classification and additional testing if necessary. 3. Evaluate the existing soil conditions found during our exploration with respect to foundation support for the proposed structure. 4. Provide recommendations with respect to foundation support of the structure, including foundation type, maximum allowable soil bearing capacity, and bearing elevations. 5. Provide site preparation criteria for the proposed construction. 1.2 Project Description Per our prior telephone discussions and email correspondence with you, GFA understands the project consists of a new single-story residence located at 10751 South Ocean Drive (Lot A-3) in Jensen Beach, Florida. At this time, no site or house plans are available. Specific design loads have not been provided to GFA. For the foundation recommendations presented in this report, we assumed a maximum wall loading of 3 kips per linear foot and a maximum column load of 35 kips. The recommendations provided herein are based upon the above considerations. If the stated conditions are incorrect or if the project description is revised, please inform GFA so that we may review our recommendations with respect to any modifications. 2.0 OBSERVATIONS 2.1 Site Description At the time of our field exploration, the site was generally flat. The elevation was approximately the same as the adjacent roadway and adjacent properties. 2.2 Field Exploration Two (2) standard penetration test (SPT) borings, advanced to an approximate depth of 15 feet below the existing ground surface, were completed for this study. The boring depths were established based upon our knowledge of vicinity soils and confined to the zone of soil likely to be influenced by the planned construction. The locations of the borings are illustrated in Appendix B - Test Location Plan. Lot A-3 Residence Geotechnical Exploration Report 10751 S Ocean Boulevard, Jensen Beach, Florida March 16, 2020 GFA Project No.: 20-8566.00 Page 2 of 6 The Standard Penetration Tests (SPT) were performed in general accordance with ASTM D 1586, “Penetration Test and Split-Barrel Sampling of Soils.” The SPT test procedure consists of driving a 1.4-inch I.D. split-barrel sampler into the soil profile using a 140-pound hammer falling 30 inches. The number of blows per foot, for the second and third 6-inch increment, is referred to as the N-value. The N-value has been empirically correlated with various soil properties and provides an indication of soil strength. The upper 4 feet of the borings were advanced by hand augering due to potential buried utility line conflicts. The augered portion of the SPT borings were performed in general accordance with ASTM D 1452, “Practice for Soil Investigation and Sampling by Auger Borings.” Hand Cone Penetrometer (HCP) tests were conducted at one-foot depth intervals in the auger borings. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Site specific survey staking of the borings was not provided for our field exploration. The indicated depth and location of each boring was approximated based upon existing grade at the time of drilling and estimated distances and relationships to the adjacent roadway and properties. 2.3 Visual Classification Soil samples recovered from our field exploration were returned to our laboratory where they were visually classified by a geotechnical engineer in general accordance with the Unified Soil Classification System (ASTM D 2487). The samples will be retained in our laboratory for 30 days from the date of this report and then discarded, unless we are notified otherwise in writing. The recovered samples were not evaluated, either visually or analytically, for chemical composition or environmental hazards. GFA will be pleased to perform these services for an additional fee, if required. 2.4 Geomorphic Conditions The geology of the site as mapped on the USDA Soil Survey website consists of Arents, 0 to 5 percent slopes (4). These are sandy soils and organic soils are not indicated. However, since Arents are areas where the soils have been generally altered by grading, shaping, and covered with fill, the soils can be variable. Note that the Soil Survey generally extends to a maximum depth of 80 inches below ground surface and is not indicative of deeper soil conditions. Boring logs resulting from our field exploration are presented in Appendix D - Log of Boring Records. The boring logs contain the soil descriptions, the standard penetration test (SPT) N-values, and the hand cone penetrometer (HCP) values logged during the drilling and sampling activities. Note that the soil boring data reflect information from a specific test location only and the soil conditions may vary between the strata interfaces indicated on the logs. The soil classifications and descriptions shown on the logs are generally based upon visual characterizations of the recovered samples using the Unified Soil Classification System. See Appendix E - Discussion of Soil Groups, for a detailed description of various soil groups. The subsurface soil conditions encountered at the boring locations generally consisted of alternating layers of very loose to dense fine sand (SP) containing varying amounts of shell to the boring termination depths. Lot A-3 Residence Geotechnical Exploration Report 10751 S Ocean Boulevard, Jensen Beach, Florida March 16, 2020 GFA Project No.: 20-8566.00 Page 3 of 6 2.5 Hydrogeological Conditions On the date of our field exploration (March 2, 2020), groundwater was encountered at an average depth of approximately 4.1 feet below the ground surface at the boring locations. Note that the groundwater table will fluctuate seasonally depending upon local rainfall and other site specific and/or local factors, including tidal influences from the adjacent Jensen Beach to Jupiter Inlet Aquatic Preserve. Brief ponding of stormwater may occur across the site after heavy or extended rainfall events. No additional evaluation was included in our scope of work in relation to the wet seasonal high groundwater table or any existing well fields in the vicinity. Well fields may influence water table levels and cause significant fluctuations. If a more comprehensive water table analysis is necessary, please contact our office for additional guidance. 3.0 ENGINEERING EVALUATION AND PRELIMINARY RECOMMENDATIONS 3.1 General Our geotechnical engineering evaluation of the site and subsurface conditions at the property, with respect to the planned construction, and our recommendations for site preparation and foundation support, are based upon (1) our site observations, (2) the field data obtained, and (3) our understanding of the project information and structural conditions as presented in this report. If the stated conditions are incorrect, or if the project description is revised, please inform GFA so that we may review our recommendations with respect to any modifications. We note that the applicability of geotechnical recommendations is very dependent upon project characteristics, specifically (1) improvement locations, (2) grade alterations, (3) and actual applied structural loads. For that reason, GFA must be provided with and review the preliminary and final site and grading plans, and structural design loads to validate all recommendations provided in this report. Without performing this review, our recommendations should not be relied upon for final design or construction of any site improvements. 3.2 Site Preparation GFA recommends the following compaction requirements for this project:  Proof Roll ............................................................... 95 percent of modified Proctor  Building Pad Fill ..................................................... 95 percent of modified Proctor  Footings ................................................................. 95 percent of modified Proctor The compaction percentages presented above are based upon the maximum dry density as determined by the modified Proctor test (ASTM D 1557). All density tests should be performed to a depth of 2 feet below stripped surface and bottom of footings. Density testing should be performed using either the nuclear method (ASTM D 6938) or the sand cone method (ASTM D 1556). Hand Cone Penetrometer (HCP) tests can also be performed to evaluate compaction. Our recommendations for preparation of the site for use of shallow foundation systems are presented below. This approach to improving and maintaining site soils has been found to be successful on projects having similar soil conditions. Lot A-3 Residence Geotechnical Exploration Report 10751 S Ocean Boulevard, Jensen Beach, Florida March 16, 2020 GFA Project No.: 20-8566.00 Page 4 of 6 1. Initial site preparation should consist of removing surface vegetation, topsoil, near surface roots, and other miscellaneous debris within and to a distance of 5 feet beyond of the planned construction limits. Foundations and the below grade remain of former structures within the footprint of the new construction should also be removed. Similarly, utility lines within the limits of the proposed construction should be removed or properly abandoned so that they will not adversely impact overlying structures. 2. Following site stripping and prior to the placement of fill, areas of surficial sand should be compacted (proof rolled) and tested. We recommend using a steel drum vibratory roller with sufficient static weight and vibratory impact energy to achieve the required compaction. Density tests should be performed on the proof rolled surface at a frequency of not less than one test per 2,500 square feet, or a minimum of three (3) tests, whichever is greater. 3. Fill material may then be placed for the building pad and general site grading, as required. The fill should be inorganic (i.e., contain less than 5 percent by weight organic material) and classified as SP, SW, GP, GW, SP-SM, SW-SM, GW-GP, or GP-GM. GFA does not recommend using fill materials having silt/clay-size soil fines contents exceeding 12 percent. Fill should be placed in lifts having a maximum thickness of 12-inches. Each lift should be compacted and tested prior to the placement of the next lift. Density tests should be performed within the fill at a frequency of not less than one test per 2,500 square feet per lift in building areas, or a minimum of three (3) tests per lift, whichever is greater. 4. For foundations placed on structural fill or compacted native granular soils, the bearing subgrade should be tested for compaction and observed by an engineer or geologist or his/her representative to determine if the soil is free of organic and/or deleterious material. Density tests should be performed at a frequency of not less than one (1) density test per each isolated column footing and one (1) test per each seventy-five (75) lineal feet of wall footing. 5. The contractor should consider the final grading contours contained in the project plans when executing backfilling and compaction operations. 3.3 Vibration Monitoring Using vibratory compaction equipment at this site may disturb nearby structures. Therefore, we recommend that these structures be monitored by GFA both before and during compaction operations. A proposal for providing vibration monitoring services during earthwork construction will be provided upon request. 3.4 Design of Footings A foundation system for any structure must be designed to resist bearing capacity failures, have settlements that are tolerable, and resist the environmental forces that the foundation may be subjected to over the life of the structure. The soil bearing capacity is the soil’s ability to support loads without plunging into the soil profile. Bearing capacity failures are analogous to shear failures in structural design and are usually sudden and catastrophic. Lot A-3 Residence Geotechnical Exploration Report 10751 S Ocean Boulevard, Jensen Beach, Florida March 16, 2020 GFA Project No.: 20-8566.00 Page 5 of 6 Based on the results of the soil borings performed at the site, GFA recommends the structure foundations be designed using a maximum allowable soil bearing pressure of 2,500 psf. Shallow foundations should be embedded a minimum of 12 inches below final grade measured from the lowest adjacent grade. Isolated column footings should be at least 24 inches in width. Continuous strip footings should have a width of at least 16 inches regardless of contact pressure. Once site preparation has been performed in accordance with the recommendations presented in this report, the soils should readily support the proposed structure bearing upon a properly designed and constructed shallow foundation system. Footings and columns should be structurally separated from the ground floor slab, as they will be loaded differently and at different times, unless a monolithic slab foundation is designed. 3.5 Settlement Estimates Post construction settlements of the structure will be influenced by several interrelated factors, including (1) subsurface soil stratification and the strength/compressibility characteristics, (2) footing size, bearing level, applied loads, and resulting bearing pressure beneath the footings, and (3) the site preparation and earthwork construction techniques used by the contractor. Our settlement estimates for the proposed construction are based on the use of the site preparation and earthwork construction methods as recommended in this report. Any deviation from these recommendations could result in an increase in the estimated post-construction settlements of the proposed construction. We expect the majority of settlement to occur in an elastic manner and fairly rapidly during construction. Using the recommended maximum bearing pressure, the assumed maximum structural loads, and the field test data that we have correlated geotechnical strength and compressibility characteristics of the subsurface soils, we estimate that total settlements of the structure could be on the order of one (1) inch or less. Differential settlements result from differences in applied bearing pressures and variations in the compressibility characteristics of the subsurface soils. Because of the general uniformity of the subsurface conditions and the recommended site preparation and earthwork construction methods presented in this report, we anticipate that differential settlements of the structure should be within tolerable magnitudes (0.5 inch or less). 3.6 Ground Floor Slabs Ground floor slabs may be constructed upon either existing grade or granular fill following completion of the foundation site preparation and fill placement procedures outlined in this report. We recommend that a modulus of subgrade reaction (k) of 150 pounds per cubic inch (pci) be considered during design. The floor slabs should be structurally separated from walls and columns to allow for differential vertical movement, unless monolithic slab foundations are designed. Excessive moisture vapor transmission through foundation slabs can result in damage to floor coverings as well as cause other deleterious affects. An appropriate moisture vapor barrier should be placed beneath the slab to reduce moisture vapor from entering the structure through the slab. The barrier should be installed in general accordance with applicable ASTM procedures including sealing around pipe penetrations and at the foundation edges. Lot A-3 Residence Geotechnical Exploration Report 10751 S Ocean Boulevard, Jensen Beach, Florida March 16, 2020 GFA Project No.: 20-8566.00 Page 6 of 6 4.0 REPORT LIMITATIONS This consulting report has been prepared for the exclusive use of JWN Builders, LLC and the project design team for the proposed residence located at 10751 S Ocean Drive (Lot A-3) in Jensen Beach, Florida. This report has been prepared in accordance with generally accepted local geotechnical engineering practices; no other warranty is expressed or implied. The evaluation submitted in this report is based in part upon the data collected during a field exploration. However, the nature and extent of variations throughout the subsurface profile may not become evident until construction. If variations then appear evident, it may be necessary to reevaluate information and professional opinions provided in this report. In the event changes are made in the nature, design, or location of the proposed structure, the evaluation and opinions contained in this report should not be considered valid unless the changes are reviewed, and conclusions modified or verified in writing by GFA. GFA should be provided the opportunity to review the final foundation plans and specifications to determine if GFA’s recommendations have been properly interpreted, communicated, and implemented. If GFA is not afforded the opportunity to participate in construction related aspects of foundation installation recommended in this report or any report addendum, GFA cannot accept responsibility for the interpretation of our recommendations made in this report or in a report addendum for foundation performance. 5.0 BASIS FOR RECOMMENDATIONS The analysis and recommendations submitted in this report are based on the data obtained from the tests performed at the locations indicated on the Test Location Plan in Appendix B. This report does not reflect any variations which may occur between borings. While the borings are representative of the subsurface conditions at their respective locations and for their vertical reaches, local variations characteristic of the subsurface soils of the region are anticipated and may be encountered. The delineation between soil types shown on the boring logs is approximate and the descriptions represent our interpretation of the subsurface conditions at the designated boring locations on the specific date drilled. Any third-party reliance of our geotechnical report or parts thereof is strictly prohibited without the expressed written consent of GFA International, Inc. The applicable SPT methodology (ASTM D 1586) and auger boring methodology (ASTM D 1452) used in performing our borings, and for determining penetration resistance, is specific to the sampling tools utilized and does not reflect the ease or difficulty to advance other tools or materials. Appendix A - Vicinity Map Site Vicinity Map Lot A-3 Residence 10751 S Ocean Drive, Jensen Beach, Florida PROJECT NO: 20-8566.00 DRAFTED BY: JR REVIEWED BY: JK DATE: 3/12/2020 N Site Location Appendix B - Test Location Plan Test Location Plan Lot A-3 Residence 10751 S Ocean Drive, Jensen Beach, Florida PROJECT NO: 20-8566.00 DRAFTED BY: JR REVIEWED BY: JK DATE: 3/12/2020 N B-1 B-2 Legend Approximate 15’ Standard Penetration Test Boring Locations Appendix C - Notes Related to Borings NOTES RELATED TO BORING RECORDS AND GENERALIZED SUBSURFACE PROFILES 1. Groundwater levels (if encountered) were recorded either during or following the boring completion on the date indicated. Fluctuations in groundwater levels are common - see the report text for a discussion. 2. The boring locations were identified in the field by estimated distances and offsets from existing reference marks and/or other site landmarks. 3. The completed boreholes were backfilled to adjacent site grade using drilling spoils and patched with asphalt cold mix in pavement areas. 4. The Log of Boring records represent our interpretation of soil conditions based on visual classification of the soil samples recovered from the borings. 5. The Log of Boring records are subject to the limitations, conclusions, and recommendations presented in the report text. 6. The Standard Penetration Test (SPT) N-values contained on the Log of Boring records refer to the total blow counts of a 140-pound drop hammer falling 30 inches required to drive a split-barrel sampler a total distance of 12 inches into soil strata at specific depth intervals. 7. The Hand Cone Penetrometer (HCP) values contained on Log of Boring records and the Cone Penetration Test (CPT) values contained on the Cone Penetration Sounding logs refer to the cone tip resistance recorded when pushing the cone tip into the soil strata at specific depth intervals. 8. The soil and/or rock strata interfaces shown on the Log of Boring records are approximate and may vary from those shown on the logs. The soil and/or rock descriptions shown on the Log of Boring records refer to conditions at the specific location tested. Soil/rock conditions may vary between test locations. 9. Relative density for coarse-grained soils (sands/gravels) and consistency for fine-grained soils (silts/clays) are described as follows: Coarse Grained Soils (Sands and Gravels) Fine Grained Soils (Silts and Clays) SPT N-Value HCP Value (kg/cm2) CPT Value (tsf) Relative Density SPT N-Value HCP Value (kg/cm2) CPT Value (tsf) Consistency 0-4 0-16 0-20 Very Loose 0-2 0-20 0-3 Very Soft 5-10 17-36 21-40 Loose 3-4 21-35 4-6 Soft 11-30 37-116 41-120 Med. Dense 5-8 >35 7-12 Firm 31-50 117-196 121-200 Dense 9-15 13-25 Stiff >50 > 196 >200 Very Dense 16-30 26-50 Very Stiff >30 >50 Hard 10. Grain size descriptions are as follows: Description Particle Size Limits Boulder Greater than 12 inches Cobble 3 to 12 inches Coarse Gravel 3/4 to 3 inches Fine Gravel No. 4 sieve to 3/4 inch Coarse Sand No. 10 to No. 4 sieve Medium Sand No. 40 to No. 10 sieve Fine Sand No. 200 to No. 40 sieve Fines (Silt/Clay) Smaller than No. 200 sieve 11. Definitions for modifiers used in soil/rock descriptions: Proportion Modifier Approximate Root Diameter Modifier <5% Trace Less than 1/32" Fine roots 5% to 12% Little 1/32" to 1/4” Small roots 12% to 30% Some 1/4” to 1" Medium roots 30% to 50% And Greater than 1" Large roots Organic Soils: Soils containing vegetative tissue in various stages of decomposition having a fibrous to amorphous texture. Usually having a dark brown to black color and an organic odor. Organic Content Modifiers: <25%: Slightly to Highly Organic; 25% to 75%: Muck; >75%: Peat Appendix D - Log of Boring Records 20 40 80 80 3 2 2 1 1 2 4 4 4 7 10 13 7 7 4 Brown fine sand, trace roots (SP) Gray fine sand (SP) Brown fine sand, trace silt (SP) Gray fine sand, trace shell fragments (SP) Light brown fine sand, some shell (SP) Bottom of borehole at 15.0 feet. 2.0 5.0 6.0 13.5 15.0 1 2 3 4 5 6 4 6 17 11 HAMMER TYPE HOLE DIAMETER 3 in DRILLER PM/JB DRILL RIG GeoProbe METHOD SPT HOLE DEPTH 15 ft DATE STARTED 3/2/20 COMPLETED 3/2/20 AT TIME OF DRILLING 4.10 ft NOTE: GROUND WATER LEVEL: DRILLING CONTRACTOR GFA International Inc. LATITUDE LONGITUDE SA M P L E GR A P H I C LO G BL O W CO U N T S MATERIAL DESCRIPTION SA M P L E NU M B E R N V A L U E PROJECT NUMBER 20-8566.00 PROJECT NAME Lot A-3 Residence PROJECT LOCATION 10751 S Ocean Drive, Jensen Beach, Florida LOG OF BORING B-1 PAGE 1 OF 1 CLIENT JWN Builders, LLC DE P T H (f t ) 2.5 5.0 7.5 10.0 12.5 15.0 MO I S T U R E CO N T E N T ( % ) FI N E S CO N T E N T ( % ) OR G A N I C CO N T E N T ( % ) SP T L O G S - G F A D A T A T E M P L A T E . G D T - 3 / 1 2 / 2 0 1 4 : 5 7 - P : \ P R O J E C T S \ 2 0 2 0 \ 2 0 - 8 5 6 6 . 0 0 - A - 3 R E N O V A T I O N S - G E O \ G E O \ A P P E N D I C E S N O R M A L \ S P T L O G S . G P J GFA International, Inc. 607 NW Commodity Cove Port Saint Lucie, Florida 34986 (772) 924-3575 20 80 80 80 3 2 2 4 3 6 8 10 5 11 32 48 7 11 12 Brown fine sand, trace shell fragments, trace roots (SP) Dark gray fine sand, trace shell fragments (SP) Gray fine sand, trace rocks, trace organics (SP) Brown-gray fine to medium sand, trace shell fragments (SP) Gray fine to medium sand, trace shell fragments (SP) Bottom of borehole at 15.0 feet. 3.5 5.0 6.0 13.5 15.0 1 2 3 4 5 6 4 14 43 23 HAMMER TYPE HOLE DIAMETER 3 in DRILLER PM/JB DRILL RIG GeoProbe METHOD SPT HOLE DEPTH 15 ft DATE STARTED 3/2/20 COMPLETED 3/2/20 AT TIME OF DRILLING 4.10 ft NOTE: GROUND WATER LEVEL: DRILLING CONTRACTOR GFA International Inc. LATITUDE LONGITUDE SA M P L E GR A P H I C LO G BL O W CO U N T S MATERIAL DESCRIPTION SA M P L E NU M B E R N V A L U E PROJECT NUMBER 20-8566.00 PROJECT NAME Lot A-3 Residence PROJECT LOCATION 10751 S Ocean Drive, Jensen Beach, Florida LOG OF BORING B-2 PAGE 1 OF 1 CLIENT JWN Builders, LLC DE P T H (f t ) 2.5 5.0 7.5 10.0 12.5 15.0 MO I S T U R E CO N T E N T ( % ) FI N E S CO N T E N T ( % ) OR G A N I C CO N T E N T ( % ) SP T L O G S - G F A D A T A T E M P L A T E . G D T - 3 / 1 2 / 2 0 1 4 : 5 7 - P : \ P R O J E C T S \ 2 0 2 0 \ 2 0 - 8 5 6 6 . 0 0 - A - 3 R E N O V A T I O N S - G E O \ G E O \ A P P E N D I C E S N O R M A L \ S P T L O G S . G P J GFA International, Inc. 607 NW Commodity Cove Port Saint Lucie, Florida 34986 (772) 924-3575 Appendix E - Discussion of Soil Groups DISCUSSION OF SOIL GROUPS COARSE GRAINED SOILS General. A soil is classified as coarse-grained if more than 50 percent of a representative sample of the material is retained on the No. 200 sieve. GW and SW Groups. These groups comprise well-graded gravelly and sandy soils containing little or no plastic fines (less than 5 percent passing the No. 200 sieve). The low fines content does not noticeably change the shear strength characteristics of these soils and does not interfere with their free-draining characteristics. GP and SP Groups. Poorly graded gravels and sands containing little or no plastic fines (less than 5 percent passing the No. 200 sieve) are in the GP and SP groups. The materials can be called uniform gravels, uniform sands, or non-uniform mixtures of very coarse materials and very fine sand, with intermediate sizes lacking (sometimes called skip-graded, gap-graded, or step-graded). This last group often results from borrow pit excavation in which gravel and sand layers are mixed. GM and SM Groups. In general, the GM and SM groups comprise gravels or sands with fines (more than 12 percent passing the No. 200 sieve) having little or no plasticity. The plasticity index and liquid limit of soils in these groups plot below the “A” line on the plasticity chart. The gradation of the material is not considered significant and both well and poorly graded materials are included. GC and SC Groups. In general, the GC and SC groups comprise gravelly or sandy soils containing fines (more than 12 percent passing the No, 200 sieve) having plasticity characteristics. The plasticity index and liquid limit of soils in these groups plot above the “A” line on the plasticity chart. FINE GRAINED SOILS General. A soil is classified as fine-grained if more than 50 percent of a representative sample of the material passes the No. 200 sieve. ML and MH Groups. These groups comprise inorganic silts (ML) and elastic silts (MH) having either low (L) or high (H) liquid limits, respectively. ML soils have a liquid limit of less than 50 while MH soils have a liquid limit of 50 and greater. Silts and elastic silts can also contain varying amounts of sand and gravel. Also included in this group are loess sediments and rock flours. CL and CH Groups. These groups comprise low plasticity (lean) clays (CL) and medium to high plasticity (fat) clays (CH) having either low (L) or high (H) liquid limits, respectively. CL soils have a liquid limit of less than 50 while CH soils have a liquid limit of 50 and greater. The low plasticity clays can also be sandy clays or silty clays. The moderate to high plasticity clays can also be sandy clays and include some volcanic clays. OL and OH Groups. These groups comprise organic silts and clays. The soils are characterized by the presence of organic odor and/or dark color. The OL and OH soils are differentiated by determining and comparing their liquid limit values before and after oven drying representative soil samples. HIGHLY ORGANIC SOILS The highly organic soils are usually very soft and compressible and have undesirable construction characteristics. Particles of leaves, grasses, branches, or other fibrous vegetative matter are common components of these soils. They are not subdivided and are classified into one group with the symbol PT. Peat humus and swamp soils with a highly organic texture are typical soils of the group.