HomeMy WebLinkAboutFlorida Energy Efficiency code FORM R405-2017
FLORIDA ENERGY EFFI0JE*PV,,tODE FOR BUILDING CONSTRUCTION
Florida Department of Business ind F ofe;--,s,!�ional Regulation - Residential Performance Method
Project Name: AQUAVISTA LOT#7 Builder Name: SION HOMES CONSTRUCTION
Street: LOT#7 Permit Office: ST.LUCIE COUNTY
City,State,Zip: FT.PIERCE,FL, Permit Number:
Owner: VENETIAN ADMINISTRATION LLC Jurisdiction:
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2
I New construction or existing New(From Plans) 9. Wall Types(5375.5 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=4.1 5141.50 ftz
b.Frame-Wood,Adjacent R=11.0 234.00 ftz
3. Number of units,If multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
10.Ceiling Types (2454.0 scift.) Insulation Area
5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 2454.00 ftz
6. Conditioned floor area above grade(ftz) 5033 b.N/A R= ftz
c.N/A R= ftz
Conditioned floor area below grade(ftz) 0
11.Ducts R ftz
7. Windows(1294.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:MECH 1 6 145
a. U-Factor: Sgi,U=0.85 1294.70 ftz b.Sup: Attic,Ret:Attic,AH:MECH 1 6 275
SHGC: SHGC=0,.35 c.Sup:Attic,Ret:Attic,AH:MECH 2 6 120
b. U-Factor: N/A ftz 12.Cooling systems kBtu/hr Efficiency
a.Central Unit 18.0 SEER:16.00
SHGC: b.Central Unit 45.5 SEER:16.00
c. U-Factor: N/A ftz
c.Central Unit 24.0 SEER:16.00
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Strip Heat 17.0 COP:1.00
SHGC: b.Electric Strip Heat 34.0 COP:1.00
Area Weighted Average Overhang Depth: 7.160 ft. c.Electric Strip Heat 17.0 COP:1.00
Area Weighted Average SHGC: 0.350 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (5033.0 scift.) Insulation Area EF:2.000
a.Floor Over Other Space R=0.0 2324.00 ftz b. Conservation features
b.Slab-On-Grade Edge Insulation R=0.0 1472.00 ft' None
c.other(see details) R= 1237.00 ftz 15.Credits CF,Pstat
Glass/Floor Area: 0.257 Total Proposed Modified Loads: 157.71 PASS
Total Baseline Loads: 158.83
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE:
6-4-20201 this building will be inspected for
compliance with Section 553.908
I hereby certify,that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE. 00- eo- 09" DATE: ii
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in 'accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(11402.4.11.2).
Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
6/4/2020 8:28 AM En ergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 8
i
FORM R405-2017 I INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: AQUAVISTA LOT#7 Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 5033 Lot#
Owner Name: VENETIAN ADMINISTRATIO Total Stories: 3 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: SION HOMES CONSTRUCTI Rotate Angle: 0 Street: LOT#7
Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE',
Family Type: Single-family FL I
New/Existing: New(From Plans)
Comment:
I I
CLIMATE
/ Design Temp Int Design Temp Heating Design�j Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
.I
Number Name Area Volume
1 UNIT#2 2615 28765
2 UNIT#1 1157 10413
3 UNIT#3 1261 11349
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 LOBBY 252 2268 No 0 1 Yes Yes Yes
2 MECH 1 180 1620 No 0 1 Yes Yes Yes
3 BONUS ROOM 604 5436 No 4 1 Yes Yes Yes
4 CABANA 121 1089 No 0 1 Yes Yes Yes
5 OPEN TO BELOW 225 2475 No 0 1 Yes Yes Yes
6 POWDER 55 605 No 0 1 Yes Yes Yes
7 MASTER BATH 160 1760 No 0 1 Yes Yes Yes
8 TOILET 30 330 No 0 1 Yes Yes Yes
u
9 WIC 160 1760 No 0 1 Yes Yes Yes
I
10 MASTER BEDROO 339 3729 No 0 1 1 Yes YeI Yes
11 GREAT ROOM 767 8437 No 0 1 Yes Yes Yes
it
12 LIBRARY 294 3234 No 0 1 Yes Yes Yes
13 BATH 6 90 990 No 0 1 Yes Yes Yes
�I
14 UTILITY 90 990 No 0 1 Yes Yes Yes
15 KITCHEN 405 4455 Yes 0 1 Yes Yes Yes
y
16 BEDROOM 4 224 2016 No 1 1 1 Yes Yes Yes
I
17 BATH 3 104 936 No 0 1 Yes YeI s Yes
18 BATH 4 82 738 No 0 1 Yes Yes Yes
19 BEDROOM 3 184 1656 No 1 1 1 Yes Yes Yes
20 BATH 2 95 855 No 0 1 Yes Yes Yes
I I
6/4/2020 8:28 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software i Page 2 of 8
I !I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
21 BEDROOM 2 271 2439 No 1 1 1 Yes Yes I Yes
22 LOFT 235 2115 No 2 1 Yes Yes l Yes
23 MECH 2 66 594 No 0 1 Yes Yes it Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio LOBBY 19 ft 0 252 ft2 ____ 0 1 0
2 Slab-On-Grade Edge Insulatio MECH 1 9 ft 0 180 ft2 ____ 0 1 0
3 Slab-On-Grade Edge Insulatio BONUS ROOM 55 ft 0 604 ft2 ____ 0 11 0
4 Slab-On-Grade Edge Insulatio CABANA 33 ft 0 121 ft2 ___- 0 1 0
5 Floor Over Other Space OPEN TO BELO ____ ____ 225 ft2 0 0 1 0
i
6 Floor Over Other Space POWDER ____ ____ 55 ft2 0 0 1 0
7 Floor Over Other Space MASTER BATH __-_ _-__ 160 ft2 0 0 1 0
8 Floor Over Other Space TOILET ____ ____ 30 ft2 0 0 1 0
9 Floor Over Other Space WIC ____ ____ 160 ft2 0 0 1 0
I
10SIab-On-Grade Edge Insulatio MASTER BEDRO 5.7 ft 0 44 ft2 ____ 0 1 0
i
11Floor Over Other Space MASTER BEDRO -___ ____ 121 ft2 0 0 1 0
12FIoor Over Other Space MASTER BEDRO ____ --__ 174 ft2 0 0 1 0
13Crawlspace GREAT ROOM 28 ft 0 537 ft2 19 0 0 1
II
14FIoor Over Other Space GREAT ROOM ____ ____ 25 ft2 0 0 1 0
1517Ioor Over Other Space GREAT ROOM ____ ____ 180 ft2 0 0 11 0
i
16Floor Over Other Space GREAT ROOM ____ ____ 25 ft2 0 0 i 1 0
17Crawlspace LIBRARY 15.2 ft 0 224 ft2 19 0 10 1
I
18Slab-On-Grade Edge Insulatio LIBRARY 4.8 ft 0 70 ft2 ____ 0 1 0
19Crawlspace BATH 6 3.3 ft 0 14 ft2 19 0 10 1
I
20Slab-On-Grade Edge Insulatio BATH 6 17.7 ft 0 76 ft2 _-__ 0 i 1 0
21Crawlspace UTILITY 8.9 ft 0 80 ft2 19 0 j 0 1
22Slab-On-Grade Edge Insulatio UTILITY 1.1 ft 0 10 ft2 ____ 0 j 1 0
23Crawlspace 1 KITCHEN 35.8 ft 0 382 ft2 19 0 0 1
24SIab-On-Grade Edge Insulatio KITCHEN 2.2 ft 0 23 ft2 ____ 0 1 0
25FIoor Over Other Space BEDROOM 4 _-__ ____ 208 ft2 0 0 1 0
I
I
i
I �
Page 3 of 8
Pa9
6/4/2020 8:28 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software I
'I
__ li
FORM 8405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
26Floor Over Other Space BEDROOM 4 ---- ---- 16 ft2 0 0 1I1 0
27SIab-On-Grade Edge Insulatio BATH 3 19.7 ft 0 64 ft2 ---- 0 111 0
I II
28Floor Over Other Space) BATH 3 ---- ---- 40 ft2 0 0 1l 0
I
29FIoor Over Other Space BATH 4 ---- ---- 82 ft2 0 0 11 0
30Slab-On-Grade Edge Insulatio BEDROOM 3 1 ft 0 9 ft2 ---- 0 1I 0
31FIoor Over Other Space BEDROOM 3 ---- ---- 175 ft2 0 0 1� 0
32SIab-On-Grade Edge Insulatio BATH 2 5.8 ft 0 19 ft2 ---- 0 11 0
33Floor Over Other Space BATH 2 ---- ---- 12 ft2 0 0 1 0
34FIoor Over Other Space BATH 2 ---- ---- 64 ftz 0 0 1 0
35FIoor Over Other Space BEDROOM 2 __-- ---- 65 ft2 0 0 1 0
I
36FIoor Over Other Space BEDROOM 2 ---- ---- 102 ft2 0 0 1 0
37Floor Over Other Space BEDROOM 2 __-- ---- 96 ft2 0 0 1 0
I
38Floor Over Other Space BEDROOM 2 ---- ---- 8 ft2 0 0 1 0
39FIoor Over Other Space LOFT ---- ---- 235 ft2 0 0 1 0
40Floor Over Other Space MECH 2 ---- ---- 10 ft2 0 0 1 0
41Floor Over Other Space MECH 2 ---- ---- 11 ft2 0 0 1 0
42Floor Over Other Space MECH 2 ---- ---- 45 ft2 0 0 1 0
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emittil Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested) Insul. (deg)
1 Hip Metal 2584 ft2 0 ft2 Light N 0.6 No 0.9 No it 20 18.4
ATTIC
/ u
# Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 2452 ft2 N N
i�
I
I
I I�
6/4/2020 8:28 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 8
I �
FORM R405-2017 I INPUT SUMMARY CHECKLIST REPORT
CEILING II
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) POWDER 19 Blown 12 ft2 0.1 Wood
2 Under Attic(Unvented) MASTER BATH 19 Blown 141 ft2 0.1 Wood
3 Under Attic(Unvenited) TOILET 19 Blown 30 ft2 0.1 Wood
4 Under Attic(Unvehted) MASTER BEDRO 19 Blown 225 ft0.1 Wood
5 Under Attic(Unvented) GREAT ROOM 19 Blown 114 ft2 0.1 Wood
6 Under Attic(Unvented) LIBRARY 19 Blown 86 ft2 0.1 Wood
7 Under Attic(Unvented) BATH 6 19 Blown 90 ft2 0.1 Wood
8 Under Attic(Unvented) UTILITY 19 Blown 90 ft2 0.1Wood
9 Under Attic(Unvented) KITCHEN 19 Blown 405 ft2 0.1 Wood
10 Under Attic(Unvented) BEDROOM 4 19 Blown 224 ft2 0.1 Wood
11 Under Attic(Unvented) BATH 3 19 Blown 104 ft2 0.1 Wood
i
12 Under Attic(Unvented) BATH 4 19 Blown 82 ft2 0.1 Wood
13 Under Attic(Unvented) BEDROOM 3 19 Blown 184 ft2 0.1 Wood
14 Under Attic(Unvented) BATH 2 19 Blown 95 ft2 0.1 Wood
15 Under Attic(Unvented) BEDROOM 2 19 Blown 271 ft2 0.1 Wood
1616 Under Attic(Unvented) LOFT 19 Blown 235 ft2 0.1 Wood
it
17 Under Attic(Unvented) MECH 2 19 Blown 66 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w
1 SE Exterior Concrete Block-Ext Insul LOBBY 4.1 4 0 9 0 36.0 ft2 0 0 0.3 0
2 SW Exterior Concrete Block-Ext Insul LOBBY 4.1 13 6 10 0 135.0 ft2 0 0 0.3 0
3 NE Exterior Concrete Block-Ext InsulMECH 1 4.1 8 1 10 0 80.8 ft2 0 0 0.3 0
4 SE Exterior Concrete Block-Ext InfiIDNUS ROO 4.1 36 0 9 0 324.0 ft2 0 0 0.3 0
5 SW Exterior Concrete Block-Ext InAMNUS ROO 4.1 17 1 10 0 170.8 ft2 0 0 0.3 0
6 NE Exterior Concrete Block-Ext InsuICABANA 4.1 13 6 10 0 135.0 ft2 0 0 0.3 0
7 SE Exterior Concrete Block-Ext InsuICABANA 4.1 9 0 9 0 81.0 ft2 0 0 0.3 0
8 NW Exterior Concrete Block-Ext InsuICABANA 4.1 8 1 10 0 80.8 ft2 0 0 110.3 0
9 SE Exterior Concrete Block-Ext InQVEN TO BE 4.1 4 0 11 0 44.0 ft2 0 0 10.3 0
10 SW Exterior Concrete Block-Ext InQVEN TO BE 4.1 15 0 11 0 165.0 ft2 0 0 0.3 0
11 SW Exterior Concrete Block-Ext InsuPOWDER 4.1 5 0 11 0 55.0 ft2 0 0 110.3 0
12 SE Exterior Concrete Block-Ext IndMASTER BA 4.1 7 0 11 0 77.0 ft2 0 0 110.3 0
13 SW Exterior Concrete Block-Ext InsMASTER BA 4.1 14 0 11 0 154.0 ft2 0 0 110.3 0
14 SE Exterior Concrete Block-Ext Insul TOILET 4.1 6 0 11 0 66.0 ft2 0 0 10.3 0
15 SE Exterior Concrete Block-Ext Insul WIC 4.1 16 0 11 0 176.0 ft2 0 0 110.3 0
16 NE Exterior Concrete Block-Ext InsMASTER BE 4.1 15 0 11 0 165.0 ft2 0 0 110.3 0
17 SE Exterior Concrete Block-Ext InsMASTER BE 4.1 18 0 11 0 198.0 ft2 0 0 10.3 0
18 NW Exterior Concrete Block-Ext InEMASTER BE 4.1 11 0 11 0 121.0 ft2 . 0 0 J 0.3 0
19 NE Exterior Concrete Block-Ext InGREAT ROO 4.1 33 0 11 0 363.0 ft2 0 0 11 0.3 0
20 NW Exterior Concrete Block-Ext InGREAT ROO 4.1 7 0 11 0 77.0 ft2 0 0 0.3 0
_21 SE Exterior Concrete Block-Ext InsuLIBRARY 4.1 6 0 11 0 66.0 ft2 0 0 1 0.3 0
_22 SW Exterior Concrete Block-Ext Insul-IBRARY 4.1 14 0 11 0 154.0 ft2 0 0 0.3 0
_23 SW Exterior Concrete Block-Ext Insul BATH 6 4.1 15 0 11 0 165.0 ft2 0 0 ! 0.3 0
I
�I
it
6/4/2020 8:28 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 8
i
I
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
P _ o
24 NW Exterior Concrete Block-Ext Insul BATH 6 4.1 6 0 11 0 66.0 ft2 0 0 0.3 0
_25 NW Exterior Concrete Block-Ext InsuIUTILITY 4.1 10 0 11 0 110.0 ft2 0 0 0.3 0
26 NE Exterior Concrete Block-Ext InsuKITCHEN 4.1 15 0 11 0 165.0 ft2 0 0 0.3 0
I
27 NW Exterior Concrete Block-Ext InsuKITCHEN 4.1 23 0 11 0 253.0 ft2 0 0 0.3 0
28 SW Exterior Concrete Block-Ext InREDROOM 4 4.1 11 8 10 0 116.7 ft2 0 0 0.3 0
29 NW Exterior Concrete Block-Ext InfiEDROOM 4 4.1 14 5 10 0 144.2 ft2 0 0 0.3 0
30 NE Exterior Concrete Block-Ext Insul BATH 3 4.1 6 4 10 0 63.3 ft2 0 0 0.3 0
31 SE Exterior Concrete Block-Ext Insul BATH 3 4.1 7 0 9 0 63.0 ft2 0 0 i0.3 0
32 NW Exterior Concrete Block-Ext Insul BATH 3 4.1 16 2 10 0 161.7 ft2 0 0 0.3 0
33 NW Exterior Concrete Block-Ext Insul BATH 4 4.1 9 0 10 0 90.0 ft2 0 0 0.3 0
_34 NE Exterior Concrete Block-Ext InEBffDROOM 3 4.1 10 10 10 0 108.3 ft2 0 0 10.3 0
35 NE Exterior Concrete Block-Ext Insul BATH 2 4.1 4 6 10 0 45.0 ft2 0 0 0.3 0
36 SE Exterior Concrete Block-Ext Insul BATH 2 4.1 19 0 9 0 171.0 ft2 0 0 0.3 0
37 SW Exterior Concrete Block-Ext Insul BATH 2 4.1 4 6 10 0 45.0 ft2 0 0 i .3 0
_38 NE Exterior Concrete Block-Ext In0EDROOM 2 4.1 12 7 10 0 125.8 ft2 0 0 j0.3 0
_39 SW Exterior Concrete Block-Ext InfiffDROOM 2 4.1 8 1 10 0 80.8 ft2 0 0 0.3 0
40 NE Exterior Concrete Block-Ext Insul LOFT 4.1 9 0 10 0 90.0 ft2 0 0 0.3 0
_41 SE Exterior Concrete Block-Ext InsuIMECH 2 4.1 11 0 9 0 99.0 ft2 0 0 0.3 0
42 SW Exterior Concrete Block-Ext InsuIMECH 2 4.1 5 5 10 0 54.2 ft2 0 0 0.3 0
_43 N Garage Frame-Wood LOBBY 11 26 9 234.0 ft2 0 0.23 :0.3 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Wood LOBBY None .2 .1 .1 .1 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade' Screening
1 SW 2 Metal Low-E Single Yes 0.85 0.35 N 24.0 ft2 8 ft 0 in 1 ft 4 in None �I None
2 SW 2 Metal Low-E Single Yes 0.85 0.35 N 46.7 ft2 8 ft 0 in 1 ft 4 in None II None
3 SE 4 Metal Low-E Single Yes 0.85 0.35 N 28.0 ft2 2 ft 0 in 1 ft 4 in None II None
4 SW 5 Metal Low-E Single Yes 0.85 0.35 N 67.2 ft2 2 ft 0 in 1 ft 4 in None None
5 SE 7 Metal Low-E Single Yes 0.85 0.35 N 20.7 ft2 2 ft 0 in 1 ft 4 in None I None
6 SW 10 Metal Low-E Single Yes 0.85 0.35 N 90.0 ft2 4 ft 0 in 1 ft 4 in None I None
7 SW 11 Metal Low-E Single Yes 0.85 0.35 N 12.0 ft2 2 ft 0 in 1 ft 4 in None it None
8 SW 13 Metal Low-E Single Yes 0.85 0.35 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None
9 SE 14 Metal Low-E Single Yes 0.85 0.35 N 14.5 ft2 2 ft 0 in 1 ft 4 in None None
I
10 SE 15 Metal Low-E Single Yes 0.85 0.35 N 14.5 ft2 2 ft 0 in 1 ft 4 in None None
11 NE 16 Metal Low-E Single Yes 0.85 0.35 N 120.0 ft2 15 ft 0 in 1 ft 4 in None None
12 SE 17 Metal Low-E Single Yes 0.85 0.35 N 12.9 ft2 2 ft 0 in 1 ft 4 in None None
13 NW 18 Metal I Low-E Single Yes 0.85 0.35 N 12.9 ft2 2 ft 0 in 1 ft 4 in None None
14 NE 19 Metal ! Low-E Single Yes 0.85 0.35 N 200.0 ft2 8 ft 0 in 1 ft 4 in None'' None
'I
6/4/2020 8:28 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 6 of 8
I !i
i
FORM 8405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade II Screening
15 NW 20 Metal Low-E Single Yes 0.85 0.35 N 60.0 ft2 15 ft 0 in 1 ft 4 in None I None
16 SW 22 Metal Low-E Single Yes 0.85 0.35 N 54.0 ft2 2 ft 0 in 1 ft 4 in None I None
17 SW 23 Metal Low-E Single Yes 0.85 0.35 N 54.0 ft2 2 ft 0 in 1 ft 4 in None I None
18 NW 25 Metal Low-E Single Yes 0.85 0.35 N 12.9 ft2 2 ft 0 in 1 ft 4 in None I None
I
19 NE 26 Metal Lo'w-E Single Yes 0.85 0.35 N 150.0 ft2 15 ft 0 in 1 ft 4 in None None
20 NW 27 Metal Low-E Single Yes 0.85 0.35 N 12.8 ft' 2 ft 0 in 1 ft 4 in None None
21 SW 28 Metal Low-E Single Yes 0.85 0.35 N 38.8 ft2 2 ft 0 in 1 ft 4 in None None
22 NE 30 Metal Low-E Single Yes 0.85 0.35 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None
23 NW 33 Metal Low-E Single Yes 0.85 0.35 N 9.0 ft2 2 ft 0 in 1 ft 4 in None I None
24 NE 34 Metal Low-E Single Yes 0.85 0.35 N 64.0 ft2 6 ft 7 in 1 ft 4 in None None
25 NE 35 Metal Low-E Single Yes 0.85 0.35 N 12.9 ft2 2 ft 0 in 1 ft 4 in None None
26 SE 36 Metal Low-E Single Yes 0.85 0.35 N 10.0 ft2 2 ft 0 in 1 ft 4 in None None
27 NE 38 Metal Low-E Single Yes 0.85 0.35 N 25.0 ft2 2 ft 0 in 1 ft 4 in None None
28 SW 39 Metal Low-E Single Yes 0.85 0.35 N 25.0 ft2 2 ft 0 in 1 ft 4 in None I None
29 NE 40 Metal Low-E Single Yes 0.85 0.35 N 64.0 ft2 6 ft 7 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 1232 ft2 1232 ft2 25 ft 9 ft 11
it
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
li 1 Wholehouse Proposed ACH(50) .000447 5894.8 323.62 608.61 .2629 7
I
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 17 kBtu/hr 2 sys#1
2 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#2
3 Electric Strip Heat% None COP:1 17 kBtu/hr 3 sys#3
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER: 16 18 kBtu/hr cfm 0.8 21 sys#1
2 Central Unit/ Split Singl SEER:16 45.5 kBtu/hr cfm 0.8 1 i sys#2
3 Central Unit/ Split Sing] SEER: 16 24 kBtu/hr cfm 0.8 311 sys#3
I I
i
I
6/4/2020 8:28 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 7 of 8
i
11
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric Heat Pump MECH 1 2 50 gal 60.9 gal 120 deg None
i
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2 II
DUCTS
/ --Supply---- ----Return--- Air CFM 25 CFM25 it HVAC#
�/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT UN RLF Heat Cool
1 Attic 6 145 ft2 Attic 55 ft2 Prop.Leak Free MECH 1 --cfm 34.7 cfm 0.03 0.50 1 1
2 Attic 6 275 ft2 Attic 85 ft2 Prop.Leak Free MECH 1 --cfm 78.4 cfm 0.03 0.50 2 2
3 Attic 6 120 ft2 Attic 55 ft2 Prop.Leak Free MECH 2 --cfm 37.8 cfm 0.03 0.50 3 3
TEMPERATURES
I
Programable Thermostat:Y Ceiling Fans: �I
i
CoolingJan Feb Mar Apr May Jun Jul Auge Oct Nov Dec
HeatinJan Feb Mar f Apr f May 4 Jun Jul 4 Aug Sep f Oct Nov f X�Dec
VentingJan Feb Mar [X]Apr [ May [ Jun Jul [ Au Se [X]Oct Nov [ ]Dec
Thermostat Schedule: HERS 2006'Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 111 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
II
Mass Type Area Thickness Furniture Fraction Space �I
Default(8 lbs/sq.ft. 0 ft2 Oft 0.3 DINING II
Default(8 lbs/sq.ft. ft2 ft 0.3 LIVNG ROOM
Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN
Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY
Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 �I
Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 1
Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 1
I I
Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Ij
Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2
i
Default(8 lbs/s .ft. j ft2 ft 0.3 A/C j
II
it
li
I
i
I
i I
I
6/4/2020 8:28 AM EnergyGaugeO USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 8 of 8
I
I
' .
2017 EPL DISPLAY CARD
������ ������������� U ���K ����U � ��U��U �� �����
ENERGY PERFORMANCE"" ~~�""�"=""�~~=� =~~�� =�"� (EPL) DISPLAY. ~~. .. ~~~ �
ESTIMATED ENERGY PERFORMANCE INDEX*= 99
. �
The lower the Energy Performance Index,the more efficient the home. ./
'|
1. New home or,addition 1' New(Fro Plans) 12. Ducts, location&insulation level
a) Supply ducts
2. Single-family ormultiple-family 2. Single-bami y b) Return ducts
.11
c)AHUlocation varies
3. No.ofunits(if multip{n-fami|y) 3. �__ �1
U
4. Number ofbedrooms 4. L12Cooling system: Cnp
a) Split system SEER 16.0
5. |athis oworst case?(yaeho) 5. No b) Single package SEER____�_
o)Ground/water source SEER/COP
___--__
8.Conditioned floor area (eq.h.) 6. 5C33d) Room unU/PTAC EE
e) Other
� 7.Windows,type and area
/ a) U-fuctoc(weightedaverage) 7a. 0.850
b)Solar Heat Gain Coeffioiord(SH8C) 7b` 0.350L_ 14. Heating system:
c)Area 7c. 1294.7 a) Split system heat pump HSP
b) Single package heat pump H8P
8. Skylights o) Electric resistance CO
e) U-factoc(woightedaverage) 8a. NA d) Gas furnace, natural gas AFU
b) Solar Heat Gain Coofficien!(SHGC) 8b. NA o) Gas furnace, LPG AFUE�___�__
f) Other
3. Floor type, insulation level:
a) S|ob'on'gnado(R'vsdue) 0u. 0.0_
b)Wood, raised (R'va(un) 9b. 19.0 1G. Water heating system
n) Concrete, raised(R-vo|um) 9o` u) Electric resistance EF�__2_.00
b) Gas fired, natural gas EE_
1D.Wall type and insulation: o) Gas fired, LPG EF--_-__
A. Exterior: d) Solar system with tank EF_______
1. Wood frame (Insulation R-va\ue) 1QA1` a) Dedicated heat pump with tank EF_
2. Masonry(insulation R'voJue) 1OA2` 4.1f) Heat recovery unit HastRaoO/o__-__-
B. AcUouent: g) Other
1. Wood frame(insulation R-va|ue) 10131._ 11.0 /
2. Masonry(Insulation R'voua) 1OB2` |
1G. HVAC credits claimed(Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 19.0_ b) Cross ventilation No
b) Single assembly 11b. c)Whole house fan ''
No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e)Multizone heating credit
f) Programmable thermostat iYes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. /|
. ./
|certify that this home has complied with the Florida BuildiCode, Energy Conservation,through thabove energy
saving features whiohbainato||ed (orexoeeded) inthinhomabefurofino| inapoct)on. Othenmiao. an�wEPL �|
disp)ayuardvvi||bono ''''p|cgedbouadoninstoUedcodonomp|iartfeagueo. �
'|
Builder Signature: Date:
/
/
Address of New Home: LOT#7 Qty/FL Zip: FT. PIERCE, FL
'
6/4/20208:28:52AN EnergyGauge@ USA 6.0.04(Rev.1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software'/Page I of 1
!
2017 -AIR BARK1t:K ANU INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: AQUAVIST A LOT#7 Builder Name: SION HOMES CONSTRUCTION
Street: LOT#7 1 Permit Office: ST.LUCIE COUNTY y
City,State,Zip: FT.PIERCE,FL, Permit Number:
W
Owner: VENETIAN ADMINISTRATION LLC Jurisdiction:
Design Location: FL,Fort Pierce
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION C RITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the I cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum. 1�
Exterior thermal envelope insulation for fr"amed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.,
Windows,skylights The space between window/door jambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.—
Batts in narrow cavities shall be cut to fit,or narrow
cavities shall be filled by insulation thatl'on
Narrow cavities installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac 3s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the�uilding
shall be sealed to the drywall. thermal envelope shall be air tight and�iC rated.
I
Plumbing and wiring Batt insulation shall be cut neatly to fit''around wiring
and plumbing in exterior walls,or insula"tion that on
installation readily conforms to available space shall
egend behind gil2ing and wirinn-
Shower/tub The air' barrier installed at exterior walls adjacent to showers and Exterior walls adjacent:to showers and�tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The ailr barrier shall be installed behind electrical or communication
I
exterior walls boxeslor air-sealed boxes shall be installed,
HVAC register boots HVAd'register boots that penetrate building thermal envelope shall
be sealed to the sub-floor or drywall.
Concealed Wheni required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire - fates and walls o
25'0"'���5 Y� '\9�Tol?ICC-4
In—addition,inspection of log walls shall be lance with the prov 00.
6/4/2020 8:29 AM Ene I rgyGauge@ USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of I