Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
-F wrightsoft° Load Short Form Entire House For: WATERSTONE LOT-56 TBD, FT. PIERCE, FL 34951 Job: Date: May 4, 2020 By: Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TD (°F) 27 16 Fireplaces 0 Daily range - L Inside humidity (%) 30 49 Moisture difference (gr/lb) 0 60 HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A' Cond GSZ140301A' AHRI ref 4888616 Coil AR'F193116C' AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling 20160 Btuh Heating output 28000 Btuh @ 47°F Latent cooling 8640 Btuh Temperature rise 27 °F Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 ROOM NAME Area (ftz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) OWNERS SUITE 180 2936 4209 165 188 DINING AREA 123 1189 1160 67 52 GREAT ROOM 287 4486 6932 252 310 BED 2 150 3308 2708 186 121 KITCHEN 184 184 1786 10 80 OS BATH 86 861 438 48 20 OS WIC 51 507 257 28 12 FOYER 74 738 541 41 24 MECH 13 13 380 1 17 HALL BATH 57 802 369 45 16 LAUNDRY 65 250 821 14 37 BEDROOM 3 141 1777 1642 100 73 HALL 29 29 57 2 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsOft' Right -Suite® Universal 2012 12.1.05 RSU02818 l .k C:1Users'Jason\DocumentsWdrightsoft HVACtwATERSTONE LOT-56.rup onto =MJ8 Front Door faces: E 2020-May-07 14:43:42 Page 1 Entire House 1470 17107 21478 960 960 Other equip loads 0 0 Equip. @ 0.95 RSM 20512 Latent cooling 9643 V Il1LV IY/U If IVI VU IVJ OVU VUV Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-May-07 14:43:42 wrightsoft• Rig htSu ite® U niv ersa1201212.1.05 RSU02818 Page A+K C:XUsemXJason\Documerits\Wrightsofl HVAC\WATERSTONELOT-56.rnp Calc=MJ8 Front Doorfaces: E wrightsil Project Summary Enure House Project Information For: WATERSTONE LOT-56 TBD, FT. PIERCE, FL34951 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Job: Date: May 4, 2020 By: Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 49 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14771 Btuh Structure 17541 Btuh Ducts 2337 Btuh Ducts 3937 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17107 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 20512 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 8590 Btuh Ducts 1053 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft2) 1470 1470 Equipment latent load 9643 Btuh Volume (ft') 12788 12788 Air changes/hour 0.31 0.16 Equipment total load 30155 Btuh Equiv. AVF (cfm) 66 34 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ140301A* Cond GSZ140301A* AHRI ref 4888616 Coil AR*F193116C* AHRI ref 4888616 Efficiency 8.6 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling 20160 Btuh Heating output 28000 Btuh@470F Latent cooling 8640 Btuh Temperature rise 27 OF Total cooling 28800 Btuh Actual air flow 960 cfm Actual air flow 960 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .t Wr1 111tsOft* 2020-May-0714:43:42 9 Rlght-Su ita® U niversa1201212. 1.05 RSU02818 Page 1 ��C:\UsersVascn\Documenls\Wrightsoft HVAC\WATERSTONE LOT-56.rup Cola =MJ8 Front Door faces: E