HomeMy WebLinkAboutLetter0
lswavnan-UM
Cort pa It's
St. Lucie County Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, Florida 34982
June 3, 2020
Community Name:
Location:
Plan Name:
Subject:
Dear Mr. Halter:
Waterstone
Fort Pierce, Florida
Ashmere - Lot 56
RE: Permit No. 2003-0637
In response to your review of the above noted permit application and community, please note the following
responses related to the architectural plans in black, italic font.
Issue - Building Review:
Please provide flame and smoke indices, per R302.9.1, R302.9.2, R302.10.1 and R302.102 of the Florida
Building Code 6' Edition, 2017.
Response: Per code sectionsR302.9.1, R302.9.2, R302.10.1 and R302.10.2 ofthe FBC2017, the plan
set has been updated to include flame and smoke indices. Please refer to sheet CS2 for updated
information.
Issue - Building Review:
Please correct "clothes dryer exhaust duct shall not exceed 25 feet' under exhaust fans and venting notes #3 on
sheet CS2 of plan set, per MI602.4.5.1 of the Florida Residential Building Code 6`s Edition 2017.
Response: Per code section M1602.4.5.1 of the FBC 2017, the clothes dryer exhaust duct note has
been updated to 35 feet in lieu of 25feet Please refer to sheet CS2 for updated information.
Issue - Building Review:
Please label egress door; per R311.2 of the Florida Residential Building Code 6' Edition, 2017.
Response: Per code section R3I1.2 of the FBC 2017, the front door has been labeled as an egress
door. Please refer to sheet Al.I for updated information.
90 MATAWAN ROAD, 5T FLOOR, MATAWAN, NJ 07747
TEL: (732)383-2200 KHOV.COM
Issue - Building Review:
Please provide column anchor detail from Typ. CW Column at Lanai/Porch on sheet A5.2 of plan set, per
R407.3 of the Florida Residential Building Code 6t° Edition, 2017.
Response: The details located on sheet A5.2 reflect architectural specifications and finishes only.
Please refer to detail 7 on sheet SD-1 of the structural documents for detailed anchoring and
connection related information.
N 5 KiR, f4CHFT6. r
A"1ID EFIf! LAPN
r0.9LAi4'11 RNFI Not
'A'rRP.li 4tLL %l0
kw+
UE RAM rM IS 1A
rnt a es
5iAMIAFp LBfC�ICY ��'�' N' f]) •s LONr,.pd
NRl GW:9
H21rt XOdl(RYUI
Le.Gfi9 gKLAY /E0.4 tH
YM11Y1L 3uNftl.
tt N•14k NtL9M25
//i EXTERIOR WALL @ FORGH/FATIO/LANAI DETAIL
� eut rs
Feel free to contact me should you have any questions or require additional information.
Regards,
Dawn Boggio-Korbelak, RA
Director, Product Development
Florida Architectural License Number: 94880
OF Fly
. AR94880
ED
pR ,
J
90 MATAWAN ROAD, 5" FLOOR, MATAWAN, NJ 07747