HomeMy WebLinkAboutLetter0 lswavnan-UM Cort pa It's St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, Florida 34982 June 3, 2020 Community Name: Location: Plan Name: Subject: Dear Mr. Halter: Waterstone Fort Pierce, Florida Ashmere - Lot 56 RE: Permit No. 2003-0637 In response to your review of the above noted permit application and community, please note the following responses related to the architectural plans in black, italic font. Issue - Building Review: Please provide flame and smoke indices, per R302.9.1, R302.9.2, R302.10.1 and R302.102 of the Florida Building Code 6' Edition, 2017. Response: Per code sectionsR302.9.1, R302.9.2, R302.10.1 and R302.10.2 ofthe FBC2017, the plan set has been updated to include flame and smoke indices. Please refer to sheet CS2 for updated information. Issue - Building Review: Please correct "clothes dryer exhaust duct shall not exceed 25 feet' under exhaust fans and venting notes #3 on sheet CS2 of plan set, per MI602.4.5.1 of the Florida Residential Building Code 6`s Edition 2017. Response: Per code section M1602.4.5.1 of the FBC 2017, the clothes dryer exhaust duct note has been updated to 35 feet in lieu of 25feet Please refer to sheet CS2 for updated information. Issue - Building Review: Please label egress door; per R311.2 of the Florida Residential Building Code 6' Edition, 2017. Response: Per code section R3I1.2 of the FBC 2017, the front door has been labeled as an egress door. Please refer to sheet Al.I for updated information. 90 MATAWAN ROAD, 5T FLOOR, MATAWAN, NJ 07747 TEL: (732)383-2200 KHOV.COM Issue - Building Review: Please provide column anchor detail from Typ. CW Column at Lanai/Porch on sheet A5.2 of plan set, per R407.3 of the Florida Residential Building Code 6t° Edition, 2017. Response: The details located on sheet A5.2 reflect architectural specifications and finishes only. Please refer to detail 7 on sheet SD-1 of the structural documents for detailed anchoring and connection related information. N 5 KiR, f4CHFT6. r A"1ID EFIf! LAPN r0.9LAi4'11 RNFI Not 'A'rRP.li 4tLL %l0 kw+ UE RAM rM IS 1A rnt a es 5iAMIAFp LBfC�ICY ��'�' N' f]) •s LONr,.pd NRl GW:9 H21rt XOdl(RYUI Le.Gfi9 gKLAY /E0.4 tH YM11Y1L 3uNftl. tt N•14k NtL9M25 //i EXTERIOR WALL @ FORGH/FATIO/LANAI DETAIL � eut rs Feel free to contact me should you have any questions or require additional information. Regards, Dawn Boggio-Korbelak, RA Director, Product Development Florida Architectural License Number: 94880 OF Fly . AR94880 ED pR , J 90 MATAWAN ROAD, 5" FLOOR, MATAWAN, NJ 07747 TEL: (732) 383-2200 KAOV.COM