Loading...
HomeMy WebLinkAboutProject InformationINCLUDES: • True Powel Electrical Technology Mode • Two Line LCD Multilingual Digital Evolution'" Controller (English/Spanish/ Model French/Portuguese) Model • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* FEATURES C INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. 0 TRUE PDWEl ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. 0 TEST CRITERIA: r PROTOTYPE TESTED . NEMA Ill EVALUATION • SYSTEM TORSIONAL TESTED . MOTOR STARTING ABILITY GENERAC° GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating s G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz s G00703&q G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz s GOO/ 043-Q G007042-0 (Aluminurn - Bisque) - 22 kW 60 Hz r/ - GENERAC' wrairsedge c &s QUIET-fES-T LISTED Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart SWltch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless other- wise directed by local codes. 0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This sate - Df -the -art power maximizing regulation system is standard on all General models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%, 0 SINGLE SOURCE SERVICE RESPONSE from General's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic. component. 0 GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line Includes its awn transfer systems and controls for total system compatibility. Lu GENERAC a1�36<,o P R 0 M I S E ®e `0' M°b'le cra � Link � MEP <flpp Bu/ry In lie USAYsmg tlomesllcanOhmlgn Darts. GENERAC® 16/20/22 kW features and benefits Engine. .. •Generac (OHVI) design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma molt' rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • Quiet Test" Greatly reduces sound output and fuel consumption during bi-weekly exercise. •"Spiny-lok" cast Iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. -Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. -Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulatestheoutput voltage to±l% prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Stvitoh a -Fully automatic Transfers your vital electrical loads to the energized source of power. -Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. • NEMA 3R Can be Installed inside or outside for maximum flexibility. Evolution— Controls -Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication In any condition. -Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. -Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. -Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. -Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. -Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds, • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting forweekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. -Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. -Electronic governor Maintains constant 60 Hz frequency. Unit -SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. -Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. -Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation Systern _.... •1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. •Direct-to-dIrt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. GENERAC® Controls 2{ine Plain Text Multilingual LCD Display Made Buttons: Auto Manual Off Ready to Run/Mampenance Messages Engine Run Hours Indication Programmable Stan delay between: 2-1500 seconds Utility Voltage Lose/Return to Utility Adjustable (Brownout Setting) Future SetCapadle Exerciser/Exercise Set Error Warning Rim/Alarm/Maintenance Logs Engine Skirt Sequence Starter Lock -out Smart Battery Charger Charger FaulVMissing AC Warning LOW Battery/Battery Pietism Protection and Battery Condition Indication Automatic Voltage Regulation with Over and Under Voltage Protection Under-Frequency/OveraaNStepper OvermfirenCProtection Safety Fused/Fuse Problem Protection Automatic Low Oil Pressure7High Oil Temperature Shutdown OvercranVOverspeed (@ 72 Hzl/rpm Sense Loss Shutdown High Engine Temperature Shutdown Internal FaulVlncorrect mining Protection Common External Fault Capability Field Upgradable Firmware Simple user Interface for sees of operation. Automatic Start on Utility failure.7 day exerciser. Starr with starter coni unit stays on, If utflirylafls, transfer to lead takes place. Stops unit. Power is removed. Control and charger still operate. Standard Standard Standard (programmable by dealer only) From 140-171 V/190-216 V Stannard 50 Events Each Cyclic cranking:16 sec on 7 rest (90 sec maximum duration). Starter cannot re-engage until 5 sec after engine has slapped. Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard -Sound levels ere men Rom Ne Mont of Ne gereat goal lerels lagan Irom other sides of the generanor may be higher Meant on Inagooks on parameters. Rating definilions-Sooner Applicabk for supplpng emergency power nor to barren oftheuriyponroutage. Nooverlood Upabiliy lsavellablelorthlsoll (All latlngsinanordancewllha$5519, IS03046and WN6271).'Veteran wattage andcurmrl sublscllo and ranged by nude Mrs askel Btuhnegajeule wheal, ambient temperature, altitude, ergine power are cwmalao, ea. 64axlmwn pncertlecreaysaboN35 percemnor eacA 1,000 Mel jl04B malars) shore sea lerel; and also will decreaseabM 1 percem for each 6 °C (10 °r� shore 16 °C (60 °F). 16/20/22 kW specifications Generator Model 6007035-0, G007036-0, G007038-0, G007039-0 G007042-0, G007043-0 G007037-0 (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (LP) 16,000 Watts' 20,000 Watts' 22,000 Watts' Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,500 Walls" 19,500 Watts' Rated Voltage 240 240 240 Rated Maximum Continuous toad Current— 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less thera5% Less than 5% Less than 5% Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60 Piz Power Factor 1.0 1.0 1.0 Battery. Requirement (not included) 12 Volta, Group 268 540 CCA Minimum or Group 35AGM650 GCA Minimum Unit Weight(lb/kg) 409/186 448/203 466/211 Dimensions (L.x-W x:H) Nmm 48 x 25 x 29/1218 x 638x 732 Sound output in dB(A) at 23 0 (7 m) with generator operating at normal load'" 66 66 67 Sound output in di at 23 IT (7 m) with generator in Quiet Test" low -speed exercise mode"" 58 58 58 Exercise duration 5 min 5 min 5 min Engine -" Type of Engine. GENERAC OHVI V -TWIN GENERAC OR V -TWIN GENERAC OHVI V -TWIN Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.51 9.5:1 Starter 12 Vote 12Vde 12 Vote Of Capacity Including Filter Approx. 1.9 q /1.8 L Approx. 1.9 gV1.8 L Approx. 1.9 cl L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas fle/hr (all 1/2 toad 193 (5.47) 205 (5.8) 184 (5.21) Full toad Liquid Propane 03/hr (gal/hr) [Vhr] 312 (8.83) 308 (8.72) 281 (7.96) 1/2 Load 69 (1.9) [7.2] 81 (2.23) [8.45] 70 (2.16) [8.16] Full Load 116 (3,19) [12.07] 140 (3.85) [14,57] 134 (3.68) [13 941 Note: Fuelpipe most be sized for full load. Required fuel pressure to generator fuel Inlet at all lead ranges - 3.5 -7 -water column. (7-13 mm mercury) for natural W. 10-12" water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft3mr x2500 (LP) or 83/m x 1000 (ND. For Megaloule content, multiply,mamr x 93.15 EP) or ri x 37.26 NG) Controls 2{ine Plain Text Multilingual LCD Display Made Buttons: Auto Manual Off Ready to Run/Mampenance Messages Engine Run Hours Indication Programmable Stan delay between: 2-1500 seconds Utility Voltage Lose/Return to Utility Adjustable (Brownout Setting) Future SetCapadle Exerciser/Exercise Set Error Warning Rim/Alarm/Maintenance Logs Engine Skirt Sequence Starter Lock -out Smart Battery Charger Charger FaulVMissing AC Warning LOW Battery/Battery Pietism Protection and Battery Condition Indication Automatic Voltage Regulation with Over and Under Voltage Protection Under-Frequency/OveraaNStepper OvermfirenCProtection Safety Fused/Fuse Problem Protection Automatic Low Oil Pressure7High Oil Temperature Shutdown OvercranVOverspeed (@ 72 Hzl/rpm Sense Loss Shutdown High Engine Temperature Shutdown Internal FaulVlncorrect mining Protection Common External Fault Capability Field Upgradable Firmware Simple user Interface for sees of operation. Automatic Start on Utility failure.7 day exerciser. Starr with starter coni unit stays on, If utflirylafls, transfer to lead takes place. Stops unit. Power is removed. Control and charger still operate. Standard Standard Standard (programmable by dealer only) From 140-171 V/190-216 V Stannard 50 Events Each Cyclic cranking:16 sec on 7 rest (90 sec maximum duration). Starter cannot re-engage until 5 sec after engine has slapped. Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard -Sound levels ere men Rom Ne Mont of Ne gereat goal lerels lagan Irom other sides of the generanor may be higher Meant on Inagooks on parameters. Rating definilions-Sooner Applicabk for supplpng emergency power nor to barren oftheuriyponroutage. Nooverlood Upabiliy lsavellablelorthlsoll (All latlngsinanordancewllha$5519, IS03046and WN6271).'Veteran wattage andcurmrl sublscllo and ranged by nude Mrs askel Btuhnegajeule wheal, ambient temperature, altitude, ergine power are cwmalao, ea. 64axlmwn pncertlecreaysaboN35 percemnor eacA 1,000 Mel jl04B malars) shore sea lerel; and also will decreaseabM 1 percem for each 6 °C (10 °r� shore 16 °C (60 °F). GENERAC' 16/20/22 kW switch options Limited ulrcuit Svji ch Model G007036-0 (16 kW) • 16 circuits. No. of Poles 2 • Electrically operated, mechanically -held contacts for fast, positive connections. Current Rating (Amps) Voltage Rating (VAC) 100 120/240,10 • Rated for all classes of load, 100% equipment rated, both inductive and resistive. Utility voltage Monitor (Fixed)' -Dropout connections. Return to utility' • Rated for all classes of load, 100% equipment rated, both inductive and • 2 pole, 250 VAC contactors. -Drop ut 65% • 30 millisecond transfer time. Return to utility' approx. 15sec. Lug Range Exercise hi -weekly for 12 minutes' Standard • Dual coil design. UL Listed Standard • Rated for both copper and aluminum conductors. Total of Pre -wired Circuits No. 15 A 126 V 16 5 • Main contacts are silver plated or silver alloy to resist welding and sticking. No. 20 A120V 5No. 20 A 246 V 1 • NEMA 39 aluminum outdoor enclosure allows for indoor or outdoor mounting No. 30 A 240 V - flexibility. No. 40A240V 1 No. 50 A 240V 1 • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from Tandem Breaker Capability 6 spaces Siemens, Murray, Eaton and Square D for the most flexible and cost effective install. circuit Breaker Protected Available RMS Symmetrical Fault Current @250 Volts 10,000 'Function of Evolution Controller Exercise can be set to weekly or monthly Dimensions 200 Amps 120/240, 1n Open Transition Service Rated Height Width Depth H1 rH2 Wt I W2 in 27.24 30.0 11.4 1 13. 1 7.09 mm 692.0 762.4 289.0 343.0 180.8 Wire flanges ' Conductor lug Neutral W Ground LugL 210-#14 2/0-#14 2/0-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). Model • Intelligently manages up to four air conditioner loads with no No. of Poles additional hardware. Current Rating (Amps) • Up to four more large (240 VAC) loads can be managed when used in Voltage Rating: (VAC) Utility voltage Monitor (Fixedl' conjunction with Smart Management Modules (SMMs). -Pick-up • Electrically operated, mechanically -held contacts for fast, clean -Dropout connections. Return to utility' • Rated for all classes of load, 100% equipment rated, both inductive and Exercise weekly for 12 minutes' resistive. UL Listed • Up to four more large (120/240 VAC) loads can be managed when used in Enclosure Type Withstand Rating (Amps) conjunction with 50 amp Power Management Modules (PMM"'). Lug Range • 2 pole, 250 VAC contactors. 'Function of Evolution Controller • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • NEMA 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Main contacts are silver plated or silver alloy to resist welding and sticking. Dimensions G007037-0 (16 kW)/13007039-0 (20 kW)/ G007043-0 (22 kW) 2 200 120/240,10 80% 65% approx. 13 sec. Standard Standard NEMA/UL 3R 22,000 250 MCM - #6 200 Amps 120/240, 1e Open Transition Service Rated He?'t WidN N1 H2 I Wt W2 Depth in 27.24 39.0 1 11.4 13.5 7.09 mm 692.9 1 762.4 1 289.9 343A 180.0 G007037-0 (16 kW)/13007039-0 (20 kW)/ G007043-0 (22 kW) 2 200 120/240,10 80% 65% approx. 13 sec. Standard Standard NEMA/UL 3R 22,000 250 MCM - #6 GENERACe dimensions & UPCs Dimensions shown are approximate. Rehr N installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. C tie.5 iN UPC 16/20/22 kW available accessories Model# Product Description G007037-0 Generac's Mobile Link allows you to check the status of your generatorfrom anywhere that you have - G006463-3 Mobile Link- access to an Internet connection from a PC or any smart device. You will even be notified via e-mail '- G007039-0 or text message when a change in the generators status occurs. Available in the U.S. only. G005819-0 26R Wet Cell Battery ' Every standby generator requires a battery to start the system. Generac offers the recommended 25R G007042-0 wet cell battery for use with all air-cooled standby product (excluding. PowerPact®). 0007101-0 ` Battery Pad Warmer The pad warmer rests under the battery. Recommended for use rf the temperature regu lady falls below 0°F. (Not necessary for use with AGM -style batteries). - G007102-0 . Oil Warmer Oil warmer slips directly overthe oil filter. Recommended for use if the temperature regularly falls below 0°F. G007103-0 Breather Warmer The breather warmer is for use In Extreme cold weather applications. For use with Evolution controllers only in climates where heavy Icing occurs. G005621-0 Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical _ Kit load you may not need. Not compatible with 50 amp pre -wired switches. 0007027-0 - Bisque Fascia Base Wrap KR The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers (Standard on 22 kW) a sleek, contoured appearance as well as offering protection from rodents and insects by covering the - lifting holes located in the base. If the generator enclosure is scratched or damaged, it is importsntto touch-up the paint to protect G005703-0 -Bisque Paint Kit from future corrosion. The paint kit Includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 -16, 20 8 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 22 kW routine maintenance on a Generac automatic standby generator. Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to 0006873-0 (50 Amps) increase its power management capabilities. It provides additional power management flexibility - not found in any other power management system. dimensions & UPCs Dimensions shown are approximate. Rehr N installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. C tie.5 iN UPC G007035-0 696471070354 6007036-0 Q oil G007037-0 696471070378 swa int FRONTNEW 9 Model UPC G007035-0 696471070354 6007036-0 696471070361 G007037-0 696471070378 6007038-0 696471070385 G007039-0 696471070392 G007040-0 696471070408 G007042-0 696471070422 G007043-0 696471070439 GENE RAC" Generale Power systems, Inc. • S45 W29290 HWY.. 59, Waukesha, WI 53189 • generac-corn 02016 Generac Power Systems, Inc. Ali rights reserved. All specurcaaons am subject N change without npdce. autle6n 10000000194-a 05/16/16