Loading...
HomeMy WebLinkAboutSITE SPECIFIC, Design pressure letter -6_09_20DWIGHT DAVIS ARCHITECT, P.A. Florida license #AR0016908 1045 S.E. Riverside Drive Stuart, Florida 34996 (772) 781-6695 June 9, 2020 St. Lucie County Building Department Fort Pierce, Florida RE: Vandling Residence 11000 South Ocean Drive Unit #3C Jensen Beach, Florida To whom it may concern: The design pressures (PSF) for the above location to replace (3) windows and (2) sliding glass doors below 30’ component height are as follows: ZONE 4 - +48.1, -52.3 ZONE 5 - +48.1 –64.6 Zone 5 is defined as 5’ of building wall from building corners. Zone 4 is defined as all other wall space. Design pressures calculated with 163mph ultimate design wind speed and 127 nominal wind speed, importance factor 1.0, exposure D, surface exposure D, category II, internal pressure coefficient +.18, -18. Sincerely, Dwight Davis AIA