HomeMy WebLinkAboutTruss•,fey
'AAA-1 ROOF
= TRUSSES
A I'LORIOA CORPORATION
RE: Job 68867
File C®PY
Lumber design values are in accordance with ANSIffPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946
Site Information:
Customer Info: DOROTHY SIMPSON Project Name: SIMPSON GARAGE
Lot/Block: Model: a= 4
Address: 5812 PINETREE DR, FORT PIERCE, FL Subdivision:
City. County: St Lucie State: FL JUL j ?
Name Address and License # of Structural Engineer of Record, If there is one, for the building. oER-111171i lG
Name: License #:
SC Lucie Count;r, FL
Address: _
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2014/TP12007 Design Program: MiTek 20/20 8.0
Wind Code: ASCE 7-10 Wind Speed: 170 MPH
Roof Load: 55.0 psf Floor Load: 0.0 psf
This package includes 10 individual, dated Truss Design Drawings and 16 Additional Drawings.
With myseal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
I Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
1
IA0029643
I A01G
6/9/17
13
STDL03
STD. DETAIL
6/9/17
25
STDL15
STD. DETAIL
6l9/17
2
IA0029650
I HC4
6/9117
14
STDL04
STD. DETAIL
6/9/17
26
STDL16
STD. DETAIL
6/9/17
3
A0029644
A02
6/9117
15
STOL05
STD. DETAIL
6/9/17
'
4
A0029645
A03
619117
16
STDLOfi
STD. DETAIL
6/9/17
5
A0029646
A04
6/9117
17
STDL07
STD. DETAIL
619117
6
A0029647
CJ1
6/9117
18
STDL08
STD. DETAIL
619117
7
A0029648
CJ3
619117
19
1 STDL09
I STD. DETAIL
6/9117
8
A0029649
CJ5
6/9/17
20
STDL10
STD. DETAIL
6/9117
9
A0029651
HJ7
619117
21
STDL11
STD. DETAIL
619/17
10
A0029652
J7
619117
22
STDL12
STD. DETAIL
619117
11
STDL01
STD. DETAIL
6/9/17
23
STDL13
STD. DETAIL
619/17
12
STDL02
I STD. DETAIL
16191V
24
STDL14
STD. DETAIL
619/17
The lmss dmwnng(s) referenced have been prepared by MI IeK mausmes, Inc. under my direct
suoervision based on the oarameters Dmvided by A-1 RoofTmsses. Ltd.
Truss Design Engineer's Name: Anthony Tombo III
My license renewal dale for the state of Florida is February28,2019.
NOTE -The seal on these drawings Indicate acceptance of professional
engineering responsibility solely for the truss components shown.
The suitability and use of components for any particular building is the responsibility of the
building designer, perANSIrrPI-1 See. 2.
The Truss Design Drawing(s)(mD[s]) referenced have been prepared based on the
construction documents (also referred to at times as 'Structural Engineering Documental
provided by the Building Designer Indicating the nature and character of the work.
The design criteria therein have been transferred to Anthony Tombo III PE by [Al Roof
Trusses or specific location]. These TDDs (also referred to at times as 'Structural O n
Engineering Documents') are specialty structural component designs and maybe
proleefs deferred or phased submittals. As a Truss Design Engineer (i.e., Special
Engineer), the seal here and on the Too represents an acceptance of professional
engineering responsibility for the design of the single Truss depicted an the TDD on yo m k
Building Designer is responsible for and shall coordinate and review the TDDs fortI I
compatibility with their written engineering requirements. Please review all TDDs h�tl ail
related notes.
is %l Page 1 of 1
Vlhl, �
T ms mm nee been biecavmca,ry sgndd and bodied dyrvmmPr, vnu.v m, r.L.,
Dead Load Dell. =12 in
7x10 =
4 a z4
4x10 = 1.5x4 11 5x10 MT2UHS W3 1.5x4 11 4x10 =
4x12 =
7-6-0 72-6-e 18-1-0 25-1-0
7-0-0 5_ 6-5.6-8 ]-n-0
Plate Offsets MY)-
t2:0-0-0.0-0$ t3:044 0-4-81
f5:0-4-0 0-4-81
16:0-0-0 0-0-61
LOADING(pst)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
PLATES
GRIP
TCLL 30.0
Plate Grip DOL 1.25
TC
0.92
Vert(LL)
-0.38
10
>796
360
MT20
244/190
TCDL 15.0
Lumber DOL 1.25
BC
0.79
Vert(TL)
-0.8710-11
>345
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr NO
WB
0.89
Horz(TL)
0.22
6
n/a
n/a
BCDL 10.0
Code FBC20141TPI2007
Matrix -MS
Wind(LL)
0.40
10
>753
240
Weight: 1181b
FT=O%
LUMBER -
TOP CHORD 2x4 SP M 31 'Except'
T2: 2x6 SP 2400F 2.0E
BOTCHORD 2x4 SP M 31
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied.
BOTCHORD
Rigid ceiling directly applied or 4-11-11 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
2 =
2845/0-M (min. 0-2-6)
6 =
2845/0-M (min. 0-2-6)
Max Horz
2 =
-77(LC 24)
Max Uplift
2 =
-1220(LC 4)
6 =
-1220(LC 5)
Max Grav
2 =
2845(LC 1)
6 =
2845(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=6883/2683,3-18=-8492/3402,
18-19=-8494/3403, 4-19=-8501/3405,
4-20=-8501/3405, 20-21=-8494/3403,
5-21=-8492/3402, 5-6=-6882/2684
BOTCHORD
2-11=-2460/6429,d 1-22=-2462/6465,
22-23=-2462/6465,10-23=-2462/6465,
9-10=-241616464,9-24=-2416/6464,
8-24=2416/6464, 6-8=-2414/6428
WEBS
3-11=34/638, 3-10=-93212338,
4-10=-1373/834, 5-10=-933/2339,
5-8=-34/638
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=S.Opsf; h=25ft;
Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; Lumber DOL=1.60
plate grip DOL=1.60
3) Provide adequate drainage to prevent water
pending.
4) All plates are MT20 plates unless otherwise
Indicated.
5) Plates checked for a plus or minus 0 degree
rotation about its center.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcunent with any other live
loads.
7)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 1220 It, uplift
at joint 2 and 1220 lb uplift at joint 6.
9) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 281
lb down and 306 lb up at 7-0-0, 173 lb down and 189
lb up at 9-0-12, 173 lb down and 189 Ile up at 11-0-12
,173 lb down and 189 lb up at 12-6-8. 173 lb down
and 189 lb up at 14-0-4, and 173 Ib down and 189 lb
up at 16-0-4, and 281 lb down and 306 lb up at
18-1-0 on top chord, and 461 It, down and 152 lb up at
7-0-0, 87Ib down at 9-0-12, 87.lb down at 11.0-12,
87Ib down at 12-6-8,87 lb down at 14-0-4, and 87 lb
down at 16-0-4, and 461 lb down and 152 lb up at
18-0-4 on bottom chord. The design/selection of such
connection device(s) is theresponsibility of others.
10) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead+, Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plo
Vert: 1-3=-90, 3-5=-90, 5-7=-90. 12-15=-20
Standard
Concentrated Loads (lb)
Vert: 3=-210(F) 5=-210(F).9=-71(F)11=-461(F)
10=-71(F)4=-173(F) 8=-461(F).18=-173(F)
19=-173(F)20=-173(F)21=-173(F)22=-71(F)
23=-71(F) 24=-71 (F)
Bmh{ daulu,ryxrmh mhiiuyf mssm((Yupn+ relll!IY([f}MLm[rdCg�l.TtljWl MfPadarErm6igbgp xm,m .1xY,xMflm kn� ma 90S)n1d atlarl w2�tGh Lmmu cev.^aiixWnn¢eniwl �
pitE AafartlhRN+MkC mpx! d4L tm CtrN(4h�m4tfWmbUpn`+ARuI Wn�4 e:u5nwtme hpdrmxAq xngxWW�gmbha 4k+mNY j� i(el ni inln+146vP i".4�rm�9u.wr,1'M '�:flnthcn"Y Ts TombUfl[, 1'-E., I
d'meAfm t�ryry4ldnbru ntx huRdACw 4f m[edenvigmm}kfxumrp�x,wztr.eeAdAttCbNxweh�klnq,d+11R{Ikajpmtl4N�4p ih�fiM,kdpf l� hLtN41m?BLZI hfxLPe dMgddk�rM{,ry'pard 4.g0083 ,..
. - ' • mdt�+"10'xxd+mGa,Ku .,x rmhalaPw¢ mdm",mrruexnuhx!ar�drq�rcxwgfudtNdrm,apo wn.dia� rn4xa'Snu�O mxq�x4Mn �@�'pdmjhisgpxr�en6b.Naglresmam:m&a .'. I
,rtiy+xrw>, qnd$rc/n4pxdyrcnrw�m�gtirmeuo�pnlnmmR�b�wm�a t{1N4danp�nd+x+vro~tla �ehdpmm,aa Inmi 445LSG ttic{e 81yd,
� (ipfiiRtl,930Rllladlrmsinrpadm 7S.TtmdHOli,$Renel mmefhPAory§enk�negbm.Grp}aM1laaSx7M1duh6enmfgpt�45r.hveAlpaaffievr,.Aiidearfjom5ai�Y,pF.' �A��N��
A
Job
Truss
Truss Type Qty
Ply
68867
AO2
HIP 2
1 I
A0029644
Jdh Reference (optional)
Al Root Trusses, Fort Plence, FL 34946, deslgngallmss.com Run: 6.UZU S Aug 31 201e Frmc a.UZU S Aug 31 2Ulb MI I6K InduSmee, IOe. Yn n UU 14:3L2a 2Ul /
nn r
4x8 =
3
4z6 =
4
Dead Load Oe0. = 5/16 in
4z4 =
1.5z4 It 3x4 = 3x4 = 4x4 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(too)
I/dell
L/d
PLATES GRIP
TCLL
30.0
Plate Grip DOL
1.25
TC 0.83
Vert(LL)
-0.15
9-12
>999
360
MT20 2441190
TCDL
15.0
Lumber DOL
1.25
BC 0.80
Vert(TL)
-0.43
9-12
>700
240
BCLL
0.0 '
Rep Stress Ina
YES
WS 0.26
Horz(rL)
0.11
5
n/a
n/a
BCDL
10.0
Code FBC2014/rP12007
Matrix -MS
Wind(LL)
0.17
7-15
>999
240
Weight:101lb FT=O%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied.
BOTCHORD
Rigid ceiling directly applied or4-7-15 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS.
(lb/size)
2 =
1564/0-M (min. 0-1-14)
5 =
1564/0-8-0 (min. 0-1-14)
Max Horz
2 =
-87(LC 9)
Max Uplift
2 =
-673(LC 8)
5 =
-673(LC 9)
Max Grav
2 =
1564(LC 1)
5 =
1564(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOPCHORD
2-3=-2704/1757, 3-4=-2453/1774,
4-5=-2705/1756
BOTCHORD
2-9=1415/2444, 8-9=1411/2452,
7-8=-1411/2452,5-7=-1422/2446
WEBS
3-9=0/302, 4-7=0/303
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft;
Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) Plates checked for a plus or minus 0 degree
rotation about its center.
5) This truss has been designed fora 10.0 psf bottom
chord live load nonconcunent with any other live
loads.
6)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearingplate capable of withstanding 673 lb uplift at
joint 2 and 673 lb uplift at joint 5.
LOAD CASE(S)
Standard
OnuPP Oryry htlM.m63(t'Jn^esi411i!Im4[WYm1;gt�tWt'INafi Jltny�ug�{nV 7eiktFappeeae Watlek uNtrrtC9Pm+3nC�l�tY�rltmp�lFrhnilbi�a SLvz�adunl Nlr0. ti
pynmxp mmrugneymm ltq mmlu lmmmgh4 gn,fgodqepe•ej,n•w mx`atgowep les mmnn nmuAw ryroav tpp6nvpmmewf�l rgad map y ml inMmurwS 'reure�cwnar Anthony,r,T.mhol[tP6-
' agrdulan4.gWuyi a� �rydag 4p.>,Iwn N+Inm nM!hSne. ewnazcmmWa6mpibwocwrrA.M1.gp mN�+mpnt.�n;umme.rmsnamtmas mamYn..dlwr�4rl.�, Awm x80053
hkuWg gmuema..l(Imnm nSpOMtimd%, irkendMMvjLgi, rallh[rcamlwMirmmmnle�mtitdt +t�aa bumnerbny kXs Icm, brio �mia^1.. °anwite vow m' - 4153St. tude Blvd.
In,rm�u4xaSlflnnm/Ohr%dh nrgMarmmrnnhti A4bf h;n4laM tr9fb}411,ypr yw b fya eiX!d(�IgMftlg inalmnNMnni�i 1rl. Tyd•AtQrCe; FL r34446
(pp'yitglr,�9916Al IaNfiusas,Y.mXpayJTamEp116P.F; PmaDumuPUhnffolpiap,moeylMa4apiphlt�ahnallXewnwpoleiHpahonAllpdrry¢e�ATholYfi X'e I(;P.j�
a
Job
Truss
Type OtyPly68867
A03
THmI
2 1
A0029645
Jah Reference o tional
nun: e.UZU s Aug 31 zuiu Print 8.U2U a AUg 31 2016 MITek Industries, Inc. Fd Jun 09 14:32:26 2017 Page 1
4x4 =
4
4x4 =
S
Dead Load Deg. = 3181n
3x6 = 3x4 = 5x6 = 3x6 =
LOADING(psf) SPACING- 2-0-0
TCLL 30.0 Plate Grip DOL 1.25
TCDL 15.0 Lumber DOL 1.25
BCLL 0.0 Rep Stress Incr YES
BCDL 10.0 Code FBC2014frPI2007
LUMBER.
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP M.30
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-9-9 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 5-4-0 oc bracing.
MTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
2 = 1564/0-M (min. 0-1-14)
7 = 1564/0-8-0 (min. 0-1-14)
Max Horz
2 = -99(LC 17)
Max Uplift
2 =-658(LC 8)
7 =-658(LC 9)
Max Grav
2 = 1564(LC 1)
7 = 1564(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-2971/2183,3-4=-2343/1697,
4-5=-2169/1673, 5-6=-2350/1701,
6-7=-2972Y2182
BOTCHORD
2-10=-1864/2737, 9-10=-125312169,
7-9=-187512738
WEBS
3-10=-700f709, 4-10=-254/420,
5-9=-256/421, 6-9=-695f705
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
CSI.
DEFL.
In
(lec)
Well
L/d
TC 0.85
Vert(LL)
-0.26
10-13
>999
360
BC 0.62
Vert(TL)
-0.66
10-13
>458
240
WE 0.34
Horz(TL)
0.10
7
n/a
r/a
Matrix -MS
Wind(LL)
0.2010-13
>999
. 240
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft;
Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water
pending.
4) Plates checked for a plus or minus 0degree
rotation about Its center.
5) This truss has been designed for a 10.0 psf bottom
chord live load noncencurrent with any other live
loads.
6) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 658 IS uplift at
joint 2 and 658 lb uplift at joint 7.
LOAD CASE(S)
Standard
2
PLATES GRIP
MT20 2441190
Weight:107lb FT=O%
Job
Truss
Truss Type Oty
Fly
A0029646
68867
A04
COMMON 4
q
Jab Reference(o tional
Al Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.020 s Aug 312016 Print: 8.020 s Aug 312016 MiTek Industries, Inc. Fit Jun 09 14:32:26 2017 Page 1
I D:mxgKTxd W IXP WXIZ?OIB671z804F-ghhEa23HNmeL8TsDwonG9AFGmpt3dCsneUn6ze?P3
-2-0 2-6$ I 19.1-13 I 25--0 I7 5-13 2-0-1-0002 -5-11-3
4xe =
Dead Load Den. =114 in
Iv
3.4 = 3x4 = 3.4 = 3> =
3x6 =
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
floc)
I/deft
Ud
TCLL
30.0
Plate Grip DOL
1.25
TC 0.62
Vart ll.L)
-0.19
8-10
>999
360
TCDL
15.0
Lumber DOL
1.25
BC 0.89
Ved(TL)
-0.41
8-10
>731
240
BCLL
0.0
Rep Stress Incr
YES
WB 0.25
Horz(TL)
0.13
6
n/a
n/a
BCDL
10.0
Code FBC2014/TPI2007
Matrix -MS
Wind(LL)
0.22
8-10
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP Ne.2
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood, sheathing directly applied or 34-15 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 4-0-4 oc bracing.
MiTek recommends that Stabilizers and rquired
cross bracing be installed dun ng truss erection, in
accordance with Stabilizer Installation ruled..
REACTIONS. (lb/size)
2 =
1564/04d-0 (min. 0-1-14)
6 =
1564/0-8-0 (min. 0-1-14)
Max Horz
2 =
-111(LC 17)
Max Uplift
2 =
-642(LC 8)
6 =
-642(LC 9)
Max Grav
2 =
1564(LC 1)
6 =
1564(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-3208/2391, 3-4=-2600/1896,
4-5=-2600/1895, "=-3208/2390
BOTCHORD
2-10=-2081/2981, 9-10=-1180/1978,
8-9=-1180/1978, 6-8=-2099/2981
WEBS
4-8=-394/657, 5-8=-7421776,
4-10=-395/657, 3-10=-7427776
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft;
Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extenor(2) zone; cantilever left and right
exposed ;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Plates checked for a plus or minus 0 degree
rotation about its center.
4)This truss has been designed for a 10.0 psf bottom
chord live load nonconcunent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 642lb uplift at
joint 2 and 642 Ib uplift atjoint 6.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 1101b FT=0
u5l rwum,y¢ rcrG•iJWu rtm u(tw^cniiiinv+smon+fcmxa�"r9Pa"jwdrmrart, tigk pn,.+„wdu awnt ine,ari,rOmjedLumaillw B,ttG�e Sm w� w beiRsm enemj
6lvtimwya r4Cuwlh¢e'nal at ri g5peppP�v('sr,wrda,,.l&vd gmrTe an mess am maaq, aartymihhiymnRsydnfu�M1t 1a3 nroCd1N iP7 nwn r�}d'ffiI na xaeay mthony TS Tomea`gF p.E.
' lmdk R4Lmhahlanicµm¢aryilnC GP.m 2NMgxpG,p•egangaa,G ,rta40. ¢G¢ea( IG4wfwPq�tM ihRlni01d�j0awu/Po'JnrdlMl+iAtRaRhMiq'n Paa,.«a.WfmgdalhGmnnll4d ig006J
nllwEhawrauewe mggM ahmlClm�rrtdur lnm`ue rind'�rt54Y vw NiR,idtmwau ammnLNim7rn'untm'es¢I+gnenm r�jd6dP)Yp�¢_kv 1, uunhia:enr9m aw/ma ?a..' . wgs$Y,a,
• ibh„A nraitq(1e4a'.!R@r.xM�Iri Mrx6�d 41Ni 0d{Nidpa�iClh4dAphary 6 Emsdjti,IXd May tavpaLleru dhh@I Fod`Ne¢ti FL;OAQ46
G¢jdCklOg011AA lod[�usn 1¢iM1pvyl.Lm.auULf kr�^�n¢ellEfdoiom"em,moefhimdrpiphElzdr iNnulMemmtipv�i-s-iodromA NaArruwr,liRPOYLlve6'oak1,FJ
Job
Tmss
Truss Type Oty Ply
68867
CJ1
CORNERJACK g 1 1
A0029647
Joh Reference o tional
At Roof Trusses, Fort Pierce, FL 34946, design@almiss.mm Run: 8.020 s Aug 312016 Print: 8.020 s Aug 31 2016 MiTek Industries, Inc. Fri Jun 09 14:32:27 2017 Page 1
ID:mxgKTxdW IXP WXiZ?OIB67lz804F-ItFmG4v83mCIdRDUVI ViNnSa lLso7M?0141JYz8?P2
-2-M 0-11-11
' 2-0-0 0 1 j 11
LOADING(psf)
SPACING-
2-0-0
CSI:
DEFL.
In
(loc)
Udell
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.56
Vert(LL)
0.00
5
>999
360
MT20 2441190
TCDL 15.0
Lumber DOL
1.25
BC 0.08
Vert(TL)
0.00
5
>999
240
BCLL 0.0
Rep Stress Ina
YES
WB 0.00
Horz(TL)
0.00
4
n/a
We
BCDL 10.0
Code FBC2014rfP12007
Matrix -MP
Wind(LL)
-0.00
5
>999
240
Weight: 6lb FT=0
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 0-11-11 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
3 =
-09/1VIechanical
2 =
433/0-8-0 (min. 0-1-8)
4 =
-104/Mechanical
Max Horz
2 =
82(LC 8)
Max Uplift
3 =
-09(LC 1)
2 =
-381(LC 8)
4 =
-104(LC 1)
Max Gmv
3 =
53(LC 8)
2 =
433(LC 1)
4 =
120(LC 8)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf, BCDL=5.Ops1; h=25ft;
Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed ;C-C for members and forces 8 MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girders) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 39 lb uplift at
joint 3, 381 lb uplift at joint 2 and 104 lb uplift at joint 4.
LOAD CASE(S)
Standard
>.�at rk„ kYirio mssfi"p ila�cniii'rraceutnAu�mmu(iotasurrermaldrb.ti,�garil yrounw w.P=mnm t�gme,ynMful'L�liumll�7f,Gaa.}saedn n%nimginmi en4.w(
NNTmPWun,1Wh}oonk as aJliclev/fx!cvh4§�We`�ba.,pwNmo�V"vm '°ra4'dk P'asoae,4. Ig.y=atpkkf�sY+ikiuNfWl Oeiarclnrve ry,einlni I4hn w,�ul�t'auacwmM : -Mthan S`Tamliritt[ifiP..
mai)mlu}ipy6ianxM;;j MOdrr aC*�'u4rPP§ettikbugPn me trpddettk& �M4d Pru7.w,wlllr,In�pmrldtmnumA;krirdMt i a4 rimrri nv.Mx�wawangda NjaPSj'ti�a Y i.
' ' ' v�dllkn! igrlwPmm U�iim nnkhtl fbx�biWo'r.�nflbmurLetavt�aaamnpOPnu?AkmmIDlxum 1�i�wndrt,;N S�r9t Ma rOlMeae.t�,e 1 d 80084
�44iN14m Hucrd7r$C�nhl•tlnryri lww m 6 xniNtsV mi ! IALP �R+ kR9+?,MrimrpnmP�e 4 4a5f Yk ludk-61`vb
Y
;. pmna S, a mk q Iw bra»eA!kpadgblap lea!#m+pso wAwy7q
a FWtNe%c9', H, ]4gdYr
(dp�IghAi'{PRFIIVNftyy4r AmM1aayi l.n6dlG if; Pepei�mpe9(Nidaiilaen,jauryl iq,�tp}pA'E'i�,ixlM1pyiifie ninf00fimfaryetnm811aAGe�se' K,IIpEprY(Gm5)0(P.).-
Job
Truss
Truss Type Oty
Ply
68867
CJ3
CORNER JACK 8
1
A0029648
Joh Reference o tienal
At Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.020 s Aug 31 2016 Print: 8.020 s Aug 31 2016 MiTek Industries, Inc. Fri Jun 09 14:32:27 2017 Page 1
1
LOADING(psf) SPACING- 2-M
TCLL 30.0 Plate Grip DOL 1.25
TCDL 1&0 Lumber DOL 1.25
BCLL 0.0 ' Rep Stress Inns YES
BCDL 10.0 Code FBC2014/TPI2007
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-11-11 oc
purins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation quids.
REACTIONS. (Ib/size)
3 = 77/1VIechanical
2 = 409/0-8-0 (min.0-1-8)
4 = 19/Mechanical
Max Horz
2 = 123(LC 8)
Max Uplift
3 = -49(LC 12)
2 =-283(LC 8)
Max Grav
3 = 77(LC 1)
2 = 409(LC 1)
4 = 44(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf, h=25ft;
Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed fora 10.0 psf bottom
chord live load nonconcument with any other live loads.
4) `This truss has been designed for a live load of
20.Opsf on the bottom chard in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
�r
CSI.
DEFL.
in
(loc)
Well
Ud
PLATES
GRIP
TC 0.56
Vert(LL)
-0.00
7
>999
360
MT20
2441190
BC 0.12
Ven( I-)
-0.00
4-7
>999
240
WB 0.00
HOrz(TL)
0.00
2
n/a
n/a
Mahix-MP
Wind(LL)
-0.01
4-7
>999
240
Weight: 121b
FT=0
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 49 Ib uplift at
joint 3 and 2831b uplift atjoint 2.
LOAD CASE(S)
Standard
r.oiy nw Xmru rx'iimanmfb(s15}n3iitwtdta..kbroulv:sam rnolarm,Y�ntt rnm�+a+.0 ��+�ien,mr I6m �Pn;'v�X3nri wq�Cfn. mwtd m >^.�:inmunetm«Ij
pil1�5vYai WIk ik,R.eineL tlN u J e gml=xPiy %60 M1.rA sgmyq exm .aim Bkr by N I$nµuktgNkks)w�kHMrRn MaJ kd0 XI! mI ban �y5x5mi9mkiusmm.R Anth6 T Tomh6lil,,P.E,.
mwd0 m b Ik'%.{Iik,ryvJl4Ak Cn kCaie enXNelpS `OeWk}dti5m`ikw Ikk BC'WR akfX3elokeflfll.IX[ry, 10Pajaa Iq R,kwvkl �4ma�aa)Ntiptl Rhk aadFwnvl}tiGmJenAlHrx YA80083„
uki6nr �p+Gai+sm. uan al eoka akp� aYv¢ �mxanuro�rc2dusaauugr�4drwi apunfkXrc6"4eelesa.mlarmei,Ar vqw{a �k1 g�,¢ww!_, oaro'tfl. ,aie mn,mnx x, 44535L woomd.
' mnklu4r+efX e�ww'hnab aVnn4 m�F+tlturswpiytivAN9mdl4M44ii frn5miwe9maaiadoymo,gacme(d t7ml. `606ke; RJ4546
� rran 9EiD791iAlr Arn,RMelb nyld.m.o0f,1�IPidoA000lMBAn,kme ym ojbw,,op pE31/3ivnEeui�pewmepRemrji£ea(�ua�IbofripswK,l�loq',i;8. 6a11¢Ah
Job
Truss
Truss Type Qty
ply
68867
CJ5
CORNER JACK 8
y
A0029649
Job Reference o tional
Al Rod nm> , run Pierce, FL 34946, oesigrugaluuss.com Run: e.u2u s Aug 31 20ib Pnnr 8.020 s Aug 31 2016 MiTek Industries, Inc. Fri Jun 09 14:32:27 2017 Page 1
ID:mxgKTxd W IXP WXIZTOIB67Iz804F-ItFcn04v83mCIdRQUVIViNnSaIIFo7M70I4IJYz87P2
-2-0-0 4-it-11
2-0-0 4-71-11
LOADING(pso
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deb
Ud
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.56
Ved(LL)
-0.02
4-7
>999
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.31
Vert(TL)
-0.07
4-7
>647
240
BCLL 0.0 '
Rep Stress Ina
YES
WB 0.00
HOrz(TL)
0.00
3
n/a
n/a
BCDL 10.0
Code FBC2014/TP12007
Matrix -MP
Wind(LL)
0.04
4-7
>999
240
Weight: 18 to FT= 0
LUMBER -
TOP CHORD 2x4 SP No.2
SOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or4-11-11 oc
pudins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
170/Mechanical
2 =
493/0-8-0 (min. 0-1-8)
4 =
62/Mechanical
Max Hom
2 =
164(LC 8)
Max Uplift
3 =
-105(LC 12)
2 =
-291(LC 8)
Max Grav
3 =
170(LC 1)
2 =
493(LC i)
4 =
88(LC 3)
FORCES. (to)
Max. Comp./Max. Ten. - All forces 250 (to) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vul1=170mph (3-second gust)
Vasd=132mph;TCDL=5.Opsf; BCDL=5.Opsf; h=25ft;
Cat. II; Exp C; End., GCpi=0.18; MWFRS (envelope)
and C-C Ecteria(2) zone; cantilever left and right
exposed ;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live loads.
4) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 105 to uplift at
joint 3 and 291'lb uplift at joint 2.
LOAD CASE(S)
Standard
m.�6tn mn.pg mrren'nmh(1cu}srtiifrwiewmvrirofrcuflAmUr.-I r4:l�pmpm rem �ux�ne Syr .Grnm,`.akmmrivapfkLa=,1�rxM ,i iwmrurtenomC.
p14u=tmdMrAax umeetm NV u7miG-w4(wa?ay,.mp6y.�7o.udumgnuamwew,rwJmyd+mkesewi ,ogw�dmmf,rydbvmrgmf mma�t�.vrt7nY Mun¢as tmrp m.vm�nmh `-pnthon T TambnliC P.6: a mae>cuskgxWrynwn 'rrydmc mq..,r a�,tem lurarmet, m&vntagMru,ormra rypuymhmm'.y to rp nrddrmnmga,Nmn1 F�;a eel r� i"n a asuard�iv tdeix"m' !* Y
anfaykvwm4mauJumomiouUs+mriirdp d. emw!ta4rFa %!hl$ ?mlraatirkID isae re r4o rxd=UuduiA�ri�m*unc6 n�uwatgv�V6sxv_mi�uom`a,wn*.rtBWde Blvd.. ,mgllAtar>tIwlmmguF.mgMLwum�«mN raprgau Wlmfiadgwnpr rub rRre;ul?wngaol§Wdmuumcmmrd. u7mti Ft'SI Ra74448
U'I Um plGdl teelimmr doe 71evE �i(E�le eru?imafR�ile` enLino hm,nehiWgdv6 Whit eMwll heml ltdeira a4.-do Iotle.g,]; rut ? E Pf 3 9 uw w v r w ov lr. FP R I i
Job
Truss
Truss Type Dry
Ply
68867
HC4
RAFTER 12
1
AO029650
Job Reference o Clonal
Al Roof Trusses, Fort Pierce, FL 34946, design@altmss.com Run: 8.020 s Aug 312016 Print: 8.020 s Aug 312016 MiTek Industries, Inc. Fd Jun 09 14:32:28 2017 Page 1
ID:YWMtaZYTmRGkHbBJyTy?Kyn003-m3o_?k5XvNu2NnOc2DplEbKgZihJXacBFygsr z8?P1
2-9-5
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL,
in
(loc)/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.35
Vert(LL)
0.02
1-2
>999
360
TCDL 15.0
Lumber DOL
1.25
BC 0,00
Vert(TL)
-0.01
1-2
>999
240
BCLL 0.0 '
Rep Stress Iner
YES
WB 0.00
Horz(TL)
-0.00
2
n/a
n/a
BCDL 10.0
Code FBC2010rrP12007
Matrix -MP
Weight: 4lb FT=O%
LUMBER -
TOP CHORD 20 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 2-9-5 oc
purlins.
BOTCHORD
Rigid ceiling directly applied.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation uida.
REACTIONS. (lb/size)
1 =
93/Mechanical
2 =
93/Mechanical
Max Horz
i =
41(LC 8)
Max Uplift
1 =
-69(LC 8)
2 =
-78(LC 8)
Max Grav
1 =
93(LC 1)
2 =
93(LC 1)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 fib) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=1160mph (3-second gust)
Vasd=124mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft;
Cat. 11; Exp D; End., GCpi=0.18; MWFRS (envelope)
and C-C Exter or(2) zone; cantilever left and right
exposed ;C-C for members and forces 8 MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2)' This truss has been designed fora live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
3) Refer to girder(s) for truss to truss connections.
4) Provide mechanical connection (by others) of truss to
bearing plate capable ofwithstanding 691b uplift at joint
1 and 78 Ib uplift at joint 2.
LOAD CASE(S)
Standard
mar rl ^�^Yh mKtw suasa(asa�Ariuimaaban4afmrW .aavimkra lnlnbr}}rm..'m r in ti r i e iygc ty�n�:iman rr t,wari La ;3n1dn ex dm�nr eaao ¢
�iK�mrk uAu {drwitopamtu 7m ewrsm�(frt !h6P�a� og2Pra m m.•s�(My,F,m6gvnia �nut3�att(ngdprynr 1y rc1N rysi lnlprr�pumpet Yssrbd+ mi9M �. pntheny 7�Tomb0iltr, P.B.
' aKAm RrNnendeni arfr/dac ['y.N;dm,drosxlxae@ra+mrea,m nddsK�@ntM1WMYdmJGII.d mmf RrgrnaddranenurR.r'jn xmrni�wgmNvs.�n�n.kmrmndtvgddx'G 1ebp... �SD667 ...;
�-i- ssm®ao yr eum f,r.a[rM,amemlmm6.r aRrlcea,ndaaosra+�r�erca@N�,ub6rmmm]nrm �ari'wnmulHjr�rjmrtN,ua;eunipa�d&fit 3'sR!r n&mbr�nwt�Ywn�- 4§S15f lode Wyll..
r . �,�liauannr.ruawkrenr.manuwa+fmaatgrr mxapmn6mrn c�uanwxu rcsnqu,'p�xnquaiw icmMrla!•t naemrcml
� Ca'idigll Albal rnurt lslEm hTrmSolltr6P dun roohUvl t o kna ioEkiedw �M1 uiKe a,m e�0ierh¢oAlfoeRM$C.1IDEoe Tto�ll l.h' T4d"P'e42, FL 34946
Mr 94 y ,+ rcrmr= cw N 4 rP. r S
Job
Truss
Truss Type Oty Ply
68867
HJ7
DIAGONAL HIP GIRDER 4 1
A0029651
Job Reference o fional
Al Hoof Tmsses, Fort Pierce, FL 34946, designgalbuss.com Run: 8.020 s Aug 312016 Print: 8.020 s Aug 31 2016 MiTek Industries, Inc. Fri Jun 09 14:32:28 2017 Page 1
ID:mxgKrxdWIXPWXi270IB671z8D4F-m3o_7k5XvNu2NnOc2DplEbKXOiV2XXheFygsr_z87P1
-2-9-15 5-10-6 9-10-1
2.9-15 5-10-6 I 3-11-11 I
Der. =114 in
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deg
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.94
Vert(LL)
-0.17
6-7
>683
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.79
Vert(TL)
-0.39
6-7
>299
240
BCLL 0.0 '
Rep Stress Ina
NO
WB 0.25
Horz(TL)
0.01
5
n/a
We
BCDL 10.0
Code FBC2014/fP12007
Matrix -MS
Wind(LL)
0.16
6-7
>718
240
Weight: 391b FT = 0
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP M 31
WEBS 2x4 SP No.3
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 5-1-12 oc
purins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
197/Mechanical
2 =
67510-10-15 (min. 0-1-8)
5 =
386/Mechanical
Max Horz
2 =
205(LC 4)
Max Uplift
4 =
-115(LC 4)
2 =
-363(LC 4)
5 =
-113(LC 8)
Max Grav
4 =
197(LC 1)
2 =
813(LC 35)
5 =
386(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
2-11=-1092/289,3-11=-1038/298
BOTCHORD
2-13=-374/1006, 7-13=-374/1006,
7-14=-374/1006, 6-14=-374/1006
WEBS
3-7=-104/728, 3-6=-1290/479
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3second gust)
Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=25ft;
Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; Lumber DOL=1.60
plate grip DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcument with any other live
loads.
4) • This truss has been designed fora live load of
20.0psf on the bottom chord In all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 1151b uplift at
joint 4, 363 Ito uplift at joint 2 and 113 lb uplift at joint 5.
7) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s)135
Ito down and 166 Ib up at 14-9, 135 lb down and 166
Ib up at 14-9, 50 Ito down and 40 Ib up at 4-2-8, 501b
down and 40 lb up at 4-2-8. and 95 lb down and 108
Ito up at 7-0-7, and 95 Ib down and 108 Ito up at 7-0-7
on top chord, and 113 Ito down and 132lb up at 1d-9,
113 Ito down and 132 Ito up at 1-4-9, 3216 down and 2
Ito up at 4-2-8, 321b down and 21b up at 4-2-8, and
371b down at7-0-7, and 37lb down at 7-0-7 on
bottom chard. The design/selection of such
connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (pit)
Vert: 14=-90, 5-8=20
Concentrated Loads (Ih)
Vert: 9=105(F=53, B=53) 10=118(F=59, B=59)
12=-86(F=43, 8=43) 13=4(F=2, B=2) 14=-67(F=-03
, B=-33)
a.a,1m ro,myh ..mr nrx.rovC.(I'slu)nr3aiuNre%nm.unii"ounerayana?nainpi. kMu,Ypp=.nw a:uemr c gm.Wpejw3a+aAwlFm.PPt£f,6, >Qetaq c6 e�.i.me mmo g
us7=alwrunx Aaroero.i me ulumvosa tw+ NePmlhimaw>a,',vmasarm,4v aaP a gm mnxk+apem@r rzrRafi 4IDowre&rlo-i latron.n n rmmvrc ma+.4 `..When li'romtioltt
' dnNa,3wa.Iwerrrof+M1wm✓h¢Lo.4r.wg.,,,,blpmgnnnntjDepr.6mgrxra(cu2emfrAr, mgdn'.wtm hmr nA6jrowwh{mnn<iw caweiatis�amac dlwyn8t"my^Ar°rr 1.9008,
1sl,aiwo- 'iNw4aigyq xa i•mio;nrMuwWMo-atmkmnacvr unmmenaPitn mMmimfronaroViro++rro a5quayMnm, la prig a�Jutu_mpr untowa!rp w➢rc wmmmval M$15k e6f
m ni0rtnnuwccAWag,b raMpwaaGxnO,mcwamnep�smiau8inwuNM AmtW na1�*00".acm mcrom!Amb
<rppl lkm 90§A=)wd2nilee AomP%1.Tam`gp11/F, Atpdmhoal>b'eEq'Y�ie 1,4aYa�n.Itp1a40ii�yaupno}I6evYmefµipfspa. homAl9adGrsu51s_BorYrinm5olA;r,E' fixh-%ear R 34846
Job
Truss
Truss Type Oty,
Ply
68867
J7
JACK -OPEN 14
1
A0029652
Jab Reference (optional)
At Roof Trusses, Fort Pierce, FL 34946, design@aluuss.com Run: 8.020 s Aug 31 2016 Print: 8.020 s Aug 312016 MiTek Industries, Inc. Fri Jun 09 14:32:29 2017 Page 1
ID:mxgKTxdWIXPWXiZ?018671Z804F-FFMMC469ghOv9wbo=K noto66tmG1slTeZPORze?PO
Load DeO. = 3116 in
7-0-0
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 30.0
Plate Grip DOL
1.25
TC 0.56
Vert(LL)
-0.11
4-7
>761
360
MT20 244/190
TCDL 15.0
Lumber DOL
1.25
BC 0.69
Vert(TL)
-0.31
4-7
>268
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Hom(TL)
0.01
3
n/a
n/a
BCDL 10.0
Code FBC2014frP12007
Matrix -MP
Wind(LL)
0.19
4-7
>440
240
Weight: 251b FT=O%
LUMBER -
TOP CHORD 2x4 SPM 30
BOT CHORD 2x4 SP No.2
BRACING-
TOPCHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOTCHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
262/Mechanical
2 =
593/0-8-0 (min.0-1-8)
4 =
92/Mechanical
Max Horz
2 =
206(LC 8)
Max Uplift
3 =
-161(LC 12)
2 =
-316(LC 8)
Max Grav
3 =
262(LC 1)
2 =
593(LC 1)
4 =
126(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust)
Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=25ft;
Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extenor(2) zone; cantilever left and right
exposed ;C-C for members and forces 8 MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) Plates checked for a plus or minus 0 degree rotation
about its center.
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 161 lb uplift at
joint 3 and 316 lb uplift at joint 2.
LOAD CASE(S)
Standard
n.,qn mma„�.e,�ruorncuafs,la}rilii i�esumm;urwmei'iotairw.rlcaurr. iviry6gr ,anw dm,,,mt ny ¢a n'a7 vd,an�tfuwdl fFnw,Mmtdv mavene.,udne ae,uj
�aylw�4m{uuµm,Wttiugnm aLUUrtnOv{,G�'+a�yywgrn ub}h,zl mtlem ngsa +rraeampN a� wlgmmevvapeN�p,t,�xi ea<lam�rot an+urctm lmMinen µ^nv={a�4 ambh..pntdcn TTombo ttf; 4.F..
a., denysa u,w{r,bny i1d3.c.�o-e�rmnmeas mMtnp, >a gnge rm;x rwsatn..o-xer�„,. Mymadl+mo+w�ur+amr nsaoniwa�Garmorl,rcs�utlr, lenrg. - r.d eoo63,.,.
mpnyo ,mrw�aw rrecexrt namtaeN rpvmav; rve�dretve,y6^r'n,.tWuw@@xnrl�iyrtl,um4 a o<r nvartm tmEsr imsH"corm{mBeiaminu_B�r..-pw`nlioaail,s "'k<uwr 44515t L6CIaBIeO.
,nd¢I j4AYl igegghiircti dnMrllw Ipi liWm MpLIb�kW6e6 OgMpn I+c1L aj_matlhllmy.lr,nvduhacueldrru� ._ FPI%PlettO. FL ;�A9C6
� (�[Yn4bt01Q@fllvr(rp7rr MtgPvyf.EohlOft.Y; Ryrd nwvlfludo�yme 4mrnyh�n@IA6ti�tdxiM1mu5 nmrepnnGu ofneAl➢aat4rsk4liiM1oarfLmSbilf,P.E- I
JANUARY 17, 2017 I TYPICAL HIP / KING JACK CONNECTION I STDTLO1
_I
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
A-1 ROOFTRUSSES
4451 ST. LUCIE SM.
PORTTPIERCE, FL 34946 Attach King Jack w/ (3) 16d Toe
nzaoalol° Nails @ TC & 24" Strap w/ (6)
10d x 1.5" ea. end @ BC
Attach End Jack's I Attach Corner Jack's
w/ (4) 16d Toe Nails @ TC w/ (2) 16d Toe Nails @ TC &
& (3) 16d Toe Nails @ BC BC (Typ)
0
ti
ich Corner Jack's
(2) 16d Toe Nails
I TC & BC (Typ)
January 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
TYPICAL HIP / KING JACK CONNECTION 1 STDTL02
MIAMI-DADE CORNERSET SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
Attach King and End Jack's
w/ (1) LSTA12 Twist Strap @ TIC w/ (10)
10d Nails Min. Per Strap and (3) 16d
Toe Nails
NOTE: IN ADDITION TO STRAPPING
TOENAIL BOTH CHORDS OF CORNER
JACKS TO CARRYING MEMBER PER T
FOLLOWING SCHEDULE:
2X4: (2) 16d Toe Nails
2X6: (3) 16d Toe Nails
LSTA12 TWIST STRAP W/ MIN. (10,
MANUFACTURER'S RECOMMENDS
JACKICORNER JACK (TYP.)
NOTE: CONNECTION DESIGNED IN
ACCORDANCE WITH FBC 2321.6-2321.7
PROVIDING METAL STRAPPING (FLORIDA
APPROVED PRODUCT) TO RESIST MIN.
700LB UPLIFT AT ALL CONNECTIONS IN
HVHZ
0
ti
Attach King and End Jack
w/ (1) HJC26 Hanger on B(
Attach Corne�Jacks
w/ (1) LSTA12 Twist Strap @
\C and BC (Typ) w/ (10) 10d
Nails Min. Per Strap
HIP OR KING JACK (TYP.)
FEBRUARY 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL NW6
772409-1010
ALTERNATE GABLE END BRACING DETAIL
ALTERNATE ❑IAGONAL BRACING TO THE BOTTOM CHORD
I'-3' MAX.
OIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCHITEI
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
HORIZONTAL BRACE
(SEE SECTION A -A)
TRUSSSES e
r 24' O.C.
STDTL03 `
2XG DIAGONAL BRACE SPACED 48'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS,-ANO ATTACHED TO
BLOCKING WITH (5) - IOd COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIND.
' PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
BRACE AND THE TWO TRUSSES ON \
\ EITHER SIDE AS NOTED. TOENAIL
\
\ BLOCKING TO TRUSSES WITH (2) -
10d NAILS AT. EACH ENO. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
END WALL
SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS.
NAILING SCHEDULE: VERTICAL
- FOR WINO SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF Uld (.131'
X 3') NAILS SPACED 6' O.C.
- FOR WINO SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALL
BRACING METHODS SHOWN ON PAGE I ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
"'-URAL,
STUD
/ AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
/ MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUOS ONLY.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR
STRUCTURAL GABLES WITH INLAYED /
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT AGGRESSED HERE.
STANDARD GABLE /
\S /
FEBRUARY 17, 2017
A4 ROOF TRUSSES
4461 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772A09.1010
STANDARD PIGGYBACK TRUSS
STDTL04
THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WINO CONDITIONS:
ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL
ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377
LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN DRAWING FOR UPLIFTS.
NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24' O.C. OR LESS.
PIGGYBACK TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL PIGGYBACK TRUSS INFORMATION.
SPACE PURLINS ACCORDING TO THE MAXIMUM
SPACING ON THE TOP CHORD OF THE BASE
TRUSS (SPACING NOT TO EXCEED 24' O.CJ
A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT.
ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 3' X
B' TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48'
O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK
TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND
NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5' X
OA99') NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM
UPLIFT CAPACITY OF 377 LEE. AT EACH 3' X S' TEE -LOCK
MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES)
ATTACH EACH PURLIN TO THE TOP
CHORD OF THE BASE TRUSS.
(PURLINS AND CONNECTION BY OTHERS)
BASE TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING
FOR ADDITIONAL BASE TRUSS INFORMATION.
FEBRUARY 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
T72A094010
SE
TRUSS
OF IOd
VALLEY TRUSS
(TYPICAL)
DETAIL A
TRUSSED VALLEY SET DETAIL - SHEATHED
GABLE ENO,
COMMON TRUSS, OR
GIRDER TRUSS
P )P
SEE DETAIL 'A'
BELOW (TYPJ
GENERAL SEPCIFICATIONS
STDTL05
1. NAIL SIZE - 3- X 0.131' = 10d
2. WOOD SCREW = 45' W545 USP OR EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24- OL. MAXIMUM) AND SECURE
TO BASE TRUSSES AS PER DETAIL 'A'.
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN CRAVINGS.
6. NAILING DONE PER NOS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C.
BASE TRUSSES
GABLE ENO,
COMMON TRUSS, OR
VALLEY TRUSS GIRDER TRUSS
(TYPICAL)
WINO DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WINO DESIGN PER ASCE 7-10: 160 MPH
.MAX MEAN -ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE
WINO DURATION OF LOAD INCREASE: LED
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24- O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
ATTACH 2X4 CONTINUOUS N2 SYP TO
THE ROOF W/ TWO USP W345 (1/4' X
4.5') WOOD SCREWS INTO EACH BASE
TRUSS.
FEBRUARY 17, 2017
A-1 ROOF TRUSSES
4451 5T. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY
TRUSS W/ ONE ROW
OF IOd NAILS 6' O.C.
TRUSSED VALLEY SET DETAIL
GABLE ENO,
COMMON TRUSS, OR
GIRDER TRUSS
DETAIL A
(NO SHEATHING) N.T.S.
P 12
SEE DETAIL 'A'
BELOW (TYPJ
STDTL06
GENERAL SPECIFICATIONS
1. NAIL SIZE =3'X 0.131'=10d
2. WOOD SCREW = 3' WS3 USP OR EQUIVALENT.
00 NOT USE DRYWALL OR DECKING TYPE SCREW.
3. INSTALL VALLEY TRUSSES (24' O.C. MAXIMUM) AND SECURE
PER DETAIL 'A'.
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING
EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY
TRUSS SPACING.
6. NAILING DONE PER NOS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C.
BASE TRUSSES
GABLE 'END,
COMMON TRUSS, OR
VALLEY TRUSS GIRDER TRUSS
(TYPICAL)
WINO DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WINO DESIGN PER ASCE 7-I0: 160 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM G/12
CATERGORY II BUILDING
EXPOSURE C
WINO DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24' D.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
ATTACH 2X4 CONTINUOUS N2 SYP TO
THE ROOF W/ TWO USP WS3 (1/4' X 3')
WOOD SCREWS INTO EACH BASE TRUSS.
F
FEBRUARY17,2017 TRUSSED
(HIGH WIND VELOCITY) AIL I STDTL07
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
ATTACH b
TRUSSES WITI-
WINO DESIGN PER ASCE 7-98, p
WINO DESIGN PER ASCE 7-10: 1
MAX MEAN ROOF HEIGHT = 30 FI
CATERGORY 11 BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCRE)
MAX TOP CHORD TOTAL LOAD =
MAX SPACING = 24' O.C. (BASE AND VALLEY)
SUPPORTING TRUSSES DIRECTLY UNDER VALLEY TRUSSES MUST
BE DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10'
ON AFFECTED TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY
TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES
LUMBER.
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE
APPLIED TO EITHER FACE.
CLIP MAY BE
APPLIED TO THIS
FACE UP TO A
MAXIMUM 6/12 PITCH
CLIP MUST BE APPLIED
TO THIS FACE WHEN
PITCH EXCEEDS 6/12
(MAXIMUM 12/12 PITCH)
FEBRUARY 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34MO
772-409-1010
STANDARD GABLE END DETAIL
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
W/IOd NAILS, G' O.C.
VER1
STUD
SECTION B-B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY:
STDTL08
VERTICAL
2X6 SP OR SPF
STUDW2X4
#2 DIAGONAL
BRACE
(4) - 16d
NAILS16d
NAILS
SPACED 6' O.C.
(27 IOd NAILS
INTO 2%62X6
SP OR
SPF #2
2X4 SP OR
SPF #2L
HORIZONTAL
NAILED TO
RTICALS
SECTION A -A
W/(4) - 10d NAILS
OIAGONAL BRACE 4' - 0' D.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12 PROVIDE 2X4 BLOCKING BETWEEN
Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
* WITH (2) - 10d NAILS AT EACH ENO.
ATTACH'DIAGONAL BRACE TO
BLOCKING WITH (5) - lOd NAILS
(4) Ed NAILS MINIMUM,
3X4= PLYWOOD SHEATHING TO
8 2X4 STO SPF BLOCK
j;
v
DIAGONAL BRACING k* L - BRACING REFER
REFER TO SECTION A -A TO SECTION B-B 24' MAX.
NOTE:
1.
MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
/
2.
CONNECTION BETWEEN BOTTOM CHORD OF GABLE ENO TRUSS AND WALL TO
12' MAX.
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3.
BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
SYSTEM.
4.
'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' OZ.
5.
DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
/
AT 4'-0' O.C.
6.
CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
WITH 15d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
THE MIOSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
7.
GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. DIAG.
BRACE
B.
THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. AT 1/3
POINTS
S.
00 NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE IF
NEEDED
TRUSSES.
I0.
10d AND 16d NAILS ARE 013l'X3A' AND 0131-X3.5- COMMON WIRE NAILS
RESPECTIVELY.
11.
SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/I POINTS
MAXIMUM STUD LENGTH
2X4 SP#31 STUD
12'O.C.
3.8.10
5-6-11
6-6-11
114-13
2X4 SP 93I STUD
16'O.C.
3-3.10
4-9-12
W1
9-10-15
2X4SP#31STUD
24'0.C.
2,M
3-11-3
54-12
B-1-2
2X4 SP #2
12'0.C.
3-19-15
m41
6-6-11
11-8.14
2X4 SP #2
i6' O.C.
LT
4-9-12
6-6-11
10-H
2X4 SP #2
24'O.C.
3-14
3-11-3
B-2-9
9-3-13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - G' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' OL., WITH 3' MINIMUM ENO DISTANCE. BRACE MUST COVER
907. OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
=30 FEET
ROOF
SHEATHING
/ (2) - 10d
NAILS
TRUSSES 0 24' O.C.
2X6 DIAGONAL BRACE
SPACED 48' D.C. ATTACHED
TO VERTICAL WITH (4) -
l6d NAILS, AND ATTACHED
TO BLOCKING WITH (5) -
l0d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
ENO WALL
STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
CONNECTION OF BRACING 13 BASED ON MWFRS.
FEBRUARY 17, 2017 1 WITH 2X BRACE ONLY I STDTL09
NOTES:
T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER SU/. OF WEB LENGTH.
�i THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO
Ali= CONTINUOUS LATERAL BRACED WEBS.
A-1 ROOF TRUSSES
4461 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X8
10d
6' O.C.
NOTE: NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON
TWO-PLY TRUSSES NAIL TO BOTH PLIES)
NAILS
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 20
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
T-BRACE / I -BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS NAILS
WEB
NAILS WEB
I -BRACE T-BRACE
SECTION DETAILS
FEBRUARY17,2017
LATERAL BRACING RECOMMENDATIONS I STDTL10
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
ALONG A FLOOR TRUSS.
=, NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
..........................:::..................� TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
A-7 ROOFTRUSSES OF THE METHODS ILLUSTRATED BELOW.
4457 57. LUCIE BLVD.
FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
772ao97010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM ENO TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (00 NOT
USE METAL FRAMING \�EB
TACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
ANCHOR TO ATTACH WITH (3) - ') C SCAB WITH ' - 10tl
TO TOP CHORD S WITH
( X 3') \NAILS WITH
( X - 1 ATTACH TO VERTICAL
WEB WITH (3) - 10d
NAILS (0131' X 3')
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
USE METAL FRAMING
ANCHOR TO ATTACH
TO BOTTOM CHORD
TRUSS
ATTACH TO VERTICAL
WEB WITH (3) - 10d
NAILS (0131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - 10d NAILS (0.131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0.131' X 3')
2X6
STRONGBACK
I
4'-0'
(TYPICAL
SPLICE)
(BY
WALL
OTHERS)
ATTACH TO CHORD
WITH (2) N12 X 3'
WOOD SCREWS
(021G' DIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (00 NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45' WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER ENO AS
SHOWN).
i 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
" '� BE SUCH AS TO AVOID .UNUSUAL SPLITTING OF THE WOOD.
A-t ROOF TRUSSES 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
4451 ST. LUCIE BLVD. Ii SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
FORT PIERCE, FL 3M1948I
A2-009-1010
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
o
J
.135
93.5
85.6
74.2
72.6
63.4
N
.162
108.8
99.6
86.4
84.5
73.8
�i
.128
74.2
67.9
58.9
57.6
50.3
U
p
J
.131
75.9
69.5
60.3
59.0
51.1
n
ri
.148
81.4
74.5
64.6
63.2
52.5
STDTL11
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
IT
NEAR SIDE
VALUES SHOWN ARE CAPACITY PER TOE -NAIL. SIDE VIEW SIDE VIEW
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. (2X4) 3 NAILS (2X3) 2 NAILS
EXAMPLE: NEAR SIDE NEAR SIDE
(3) - 16d NAILS (0162'.DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
NEAR SIDE NEAR SIDE
FOR LOAD DURATION INCREASE OF 1.15:
3 (NAILS) X 845 (LB/NAIL) X LIS (OOL) = 2915 LB MAXIMUM CAPACITY NEAR SIDE NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30' TO 60'
ANGLE MAY
VARY FROM
30' TO 60'
ANGLE MAY
VARY FROM
30' TO 60'
45.00° \ `i` __--A 1 45.00° I 45.00°
FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDR12
A4 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
LO
.131
59
46
32
30
20
J
.135
60
48
33
30
20
to
ch
.162
72
58
39
37
25
J
2
U
.128
54
42
28
27
19
F-
LO
z
Z
.131
55
43
29
28
19
W
.148
62
48
34
31
21
-1
J
CV
Q
M
Z
.120
51
39
27
26
17
C
Z
.128
49
38
26
25
17
O
.131
51
39
27
26
17
J
.148
57
44
31
28
20
I+1
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER ENO AS SHOWN.
2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND OOL OF 1.33:
3 (NAILS) X 37 U_B/NAIL) X 133 (OOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO
FOR WINO DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 IDOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
*** USE (3) TOE -NAILS ON 2X4 BEARING WALL
•** USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S:
SIDE VIEW
L
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
END VIEW
L
NAIL
NAIL
FEBRUARY 5, 2016
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
W--V:c1
TYP 2x2 NAILER ATTACHMENT 1 STDTLI3
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX- LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
April 11, 2016 TYPICAL ALTERNATE BRACING DETAIL STDTL14
FO EXTERIOR FLAT GIRDER TRUSS
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
12
VARIES
(4) 12d
MAX 30" (2'-6")
2x6 #2 SP (Both Faces)
24VI O.C.
SIMPSON H5
J
FEBRUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15
DAMAGED OR MISSING CHORD SPLICE PLATES
O,
.I
ter,,
TOTAL NUMBER MAXIMUM FORCE (LBS) 157
OF NAILS EACH
SIDE OF BREAK
X
(INCHES)
LOAD DURATION
SP
❑F
SPF
HF
FEBRUARY17,2017 1 SCAB APPLIED OVERHANGS I STDTL16
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 345
772-404W10
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 115
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2XG
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
ENO BEARING CONDITION
NOTES:
1. ATTACH 2%SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS 048' DIA. X 3') SPACED G' O.C.
2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24,
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
A-1 ROOF
TRUSSES
A FLORIDA CORPORATION
Important Notes / Please Review Prior to Truss Installation:
1) Trusses are to be handled, installed and braced in accordance to the following standards: ANSI/TIP 1-2007i
WTCA 1-1995 —'Standard Responsibilities in the Design Process Involving Metal Plate Connected Wood Trusses',
and "BCSI 1-03 Guide to Good Practice For Handling, Installing, & Bracing of Metal Plate Connected Wood
Trusses" published by WTCA and Truss Plate Institute. Any of this material can be obtained by contacting A-1 Roof
Trusses. Spanish versions are also available.
2) All temporary and permanent bracing design, connection, material, and labor by others.
3) Truss designs are for an individual component, not for a truss system. Reactions and uplifts may vary from building
designers calculated loads. The building designer is ultimately responsible for clarifying any discrepancies.
4) If provided by truss manufacturer, any engineered beams provided have been sized using information design
guides or software provided by the beam manufacturer. The building designer should verify all loads uplifts, and
bearing requirements. Truss manufacturer is not responsible for specifying beams, other than those provided by
truss manufacturer.
5) Unless specified, roof trusses are not designed for any additional attic storage loads.
6) On flat surfaces, adequate drainage must be provided to avoid ponding.
7) It is the builder's responsibility to assure there is adequate room for A/C ducts, electrical wiring and plumbing runs
to assure they,do not interfere with the truss chords. (Roof and floor.) Truss chords and webs cannot be cut. Attic
access opening should be located between trusses unless otherwise noted.
8) Unless specified, valley framing design, connection, material and labor to be supplied by the builder.
9) Attached drawings are standard details that cover most installation standards. Structural details provided by the
building designer supersede any attached details.
10) Trusses are not designed to carry the chimney, cupola, steeple, or other structures unless specified. Structure should
be framed through the trusses to be supported by the foundation. In cases where trusses are designed to carry the
structure above all loads and uplifts MUST be verified by building designer. Connection of structure to trusses must
be provided by the building designer.
1 1) The specific engineered truss drawings are subject to other terms, conditions, and details on the truss placement plan
and/or individual truss design drawings.
12) Trusses are designed to carry ONLY the specified loads on the engineered drawings. Point loads for materials,
erection personnel, equipment, whether temporary or permanent, are not allowed unless specified on sealed
engineered drawings.
Any questions or comments feel free to contact A-1 Roof Trusses at 772-409-1010.
4451 St. Lucie Blvd., Fort Pierce, FL 34946
772-409-1010 Office 772-409-1015 Fax www.Altruss.com
�SP
+ STRUCTURAL
CONNECTORS'
A MTak' Company
Hangers
Allowable Load (lbs)
'
DF-L/SP
LSL
LVL
PSL
SPF
1-10IST
"
160%
LISP
Label
Stock No.
Code Reports
100%
115%
125%
Uplift
100%
100%
100%
100%
100%
Fastener Schedule
Tl
JU524
1881,
655
750
820
510
-
-
-
-
-
(4) - 10d (Header)
FL821.39,
(2) -10d (Joist)
11-
0510.01,
RR 25779
LUS24
6ID
70
825
490
-
-
-
-
(4)-IN(Header)
(2)-IN lloi:r)
T2
JU526
1881,
850
975
1060
1115
-
--
-
-
-
(4) - 10d (Header)
FL821.42,
(2) -10d (Joist)
11-
0510.01,
RR 25779
LUS26
865
990
1020
1165
-
-
-
-
(4)-100(Header)
(2)-lOdpobli
T3
MSH422
1831,
2025
2025
2025
-
-
-
-
-
-
(22) - lOd (Face -Face Max Nailing)
FL822.36,
(6) -10d (Face - Top Max Nailing)
08-
(6) - 30d (Joist -Face Max Nailing)
0303.06,
(6) -10d (Joist -Top Max Nailing)
RR 25836
(4) - 10d (Top - Top Max Nailing)
13116-R
MA422
V45
2245
2245
-
-
-
-
-
-
(6)- Mat (Coined Member -Face Mount)
(6) - IN (Lamed Member - Top Range)
(22)-2 0(Face. Fare Moant)
(2) -160 (Face- Top Range)
(4)-16d (Top -Top Flonge)
W1422
ins
3835
1835
-
-
-
-
-
(2)-IWx 1-112 or2-INx 1-1,2(ramed Member)
(20)-IOd or(2)-100(Face)
(4)-IN(Top)
T4
THD26
1781,
2485
2855
3060
2170
-
-
-
-
-
(18) - 16d (Face)
FL13285.35,
(12) -10d x 1-1/2 (Joist)
06-
0921.05,
RR 25843
HW26
2940
3340
3600
1555
-
-
-
(11)-lndx 1-112(carried Member)
(201- IN- I-112 (Carried Member. Max Nailing)
(20)-IN. 1-112(Ca10ng Member)
(IO)-16dx1-]/I (CvrryinBMember-Mvx Noiling)
us
A RUCTU�
P Y
Hangers
Allowable Load (lbs)
DF-L/SP
lSL
LVL
PSL
SPF
I --JOIST
USP
160%
Label
Stock No.
Code Reports
NOV
115%
125%
Uplift
100%
100%
100%
100%
100%
Fastener Schedule
T9
THD48
1781,
3950
4540
4935
2595
-
-
-
-
-
(28) - 16d (Face)
FL13285.35,
(16) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHU5
4210
One
5140
2000
-
-
-
(22)46d(Fam)
(6)-16d(fo8t)
T10
THDH26-2
1881,
3915
4505
4795
2235
-
-
-
-
-
(20) - 16d (Face)
FL821.75,
(8) - 10d (Joist)
06-
0921.05,
RR 25779
13116-R
HGU526-1
4355
4875
5230
2155
-
-
-
-
(20)-16d(face)
f81-16d(lolsQ
T11
THDH26-3
1881,
3915
4505
4795
2235
-
-
-
-
-
(20) - 16d (Face)
FL821.75,
(8) -10d (Joist)
06-
0921.05,
RR 25779
HGU526,3
4355
4875
5230
2155
-
-
-
(20)-16d(FOtt)
(6)-16d nehu
T12
THDH28-2
1881,
6535
7515
8025
2665
-
-
-
-
-
(36) - 16d (Face)
FL821.77,
(30) - 16d (Joist)
RR 25779
13126-R
-
HGU528-2
7460
7460
7460
3235
-
-
-
-
(36) - 16d (Face)
(12). 16d(loet)
T13
THDH28-3
1881,
6770
7785
8025
2665
-
-
-
-
-
(36) - 16d (Face)
FL821.75,
(10) -16d (Joist)
06-
0921.05,
RR 25779
HGOS28-3
7460
7460
7460
3235
-
-
-
-
(36) - 16d (Face)
(12)-16drlola)
r'
STRUCT URAL
P
nrtpaY
Hangers
- Allowable Load (lbs)
DF-L/SP
LSL
LVL
PSL
SPF
I -JOIST
160%
LISP
Label
Stock No.
Code Reports
100%
115%
125%
Uplift
100%
100%
100%
100%
100%
Fastener Schedule
TS
THD26-2
1781,
2540
2920
3175
2285
-
-
-
-
-
(18) - 16d (Face)
FL13285.35,
(12) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHUU&2
2265
3155
305
1550
-
-
-
(14)-16d(FQae)
(6)-16d(JaaO
Hi11262
2940
3340
3"
WS
-
-
-
-
-
f2g)- IM(CoeHedMember-Max Naiing)
(20),I6d(Con sing Member. Max Nailing)
T6
THD28
1781,
3865
3965
3965
2330
-
-
-
-
-
(28) - 16d (Face)
FL13285.35,
(16) -10d x 1-1/2 (Joist)
06-
0921.05,
RR 25843
HN28
3820
4340
4680
2140
-
-
-
(26)-10dx 1-1,2(cooled Member - Max Nailing)
(26).16d(Coning Member -Max Nailing)
T7
THD28-2
1781,
3950
4540
4935
2595
-
-
-
-
(28) - 16d (Face)
FL13285.35,
(16) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHUs2e-2
4210
4M
51"
2000
-
-
-
-
-
(22)-16sipme)
(8). 16d(Joist)
M28-2
3820
4340
400
3485
-
-
-
(26)- 10d(canned Member -Max Naiing)
(26)-16d(Carrylag Member -Max Nailing)
T8
THD46
1781,
2540
2920
3175
2285
-
-
-
-
-
(18) - 16d (Face)
FL13285.35,
(22) -10d (Joist)
06-
0921.05,
RR 25843
13116-R
HHUS46
2"0
3160
3410
1550
-
-
-
(14)-16d(Fare)
(6).l6d(lobt)
ti
STRUCTURAL
A MiTeWCompany
Fastener Comparison Table
Connector Schedule
Group
Label
LISP Stock No
Required Fasteners
Reference No
Required Fasteners
(4) - 10d (Header)
(4) - 10d (Header)
-
T1
JUS24
LUS24
(2) -10d (Joist)
(2) -10d (Joist)
(4) -10d (Header)
(4) - Sod (Header)
-
T2
JUS26
LUS26
(4) -10d (Joist)
(4) -10d (Jost)
(22) -10d (Face - Face Max Nailing)
16) -16d (Carried Member- Face Mount)
(6) -10d (Face - Top Max Nailing)
16) -16d (Carried Member - Tap Flange)
-
T3
MSH422
(6) - lod (Joist - Face Max Nailing)
THA421
(22) - 16d (Face - Face Mount)
(6) -10d (Joist -Top Max Nailing)
(2) -I6d (Face -Top Flange)
(4) - lod (Top -Top Max Nailing)
(4) - IGo (Top -Top Flange)
(11) -10dx I-112 (Carried Member)
(I8) - 16d (Face)
(12) -10d x 1-1/2 (Joist)
(20)-10dx1-1/1(Carried Member- Max Nailing)
-
T4
THD26
HTU26
(20) -16d (Carrying Member)
(20) -16d (Carrying Member -Max Nailing)
(18) - 16d (Face)
(14) - I6d (Face)
-
TS
'THD26-2
HHUS26-2
(12) -10d (Joist)
(6) - I6d (Joist)
(28) - I6d (Face)
(26) -10dx 1a/2 (Carried Member -Max Nailing)
-
T6
THD28
HTU28
(16) -10d x 1-1/2 (Joist)
(26)-16dx 1.112 (Carrying Member -Max Nailing)
(281-I6d(Face)
(22) - I 6d (Face)
-
T7
THD28-2
HHUS28-2'
(16) -10d (Joist)
(8) - 16d (Joist)
(18) - 16d (Face)
(14) - 16d (Face)
-
T8
THD46
HHUS46
(12) - lad (Joist)
(6) -16d (Joist)
(28) -16d (Face)
(22) - 16d (Face)
-
T9
THD48
HHUS48
(16) -10d (Joist)
(8) - I6d (Joist)
(20) - 16d (Face)
(20) -16d (Face)
-
T10
THDH26-2
HGUS26-2
(8) -16d (Joist)
(8) -16d (Joist)
(20) - I6d (Face)
(20) —16d (Face)
-
T11
THDH26-3
HGUS26-3
(8) -16d (Joist)
(8) -16d (Joist)
(36) - 16d (Face)
(36) - I6d (Face)
-
T12
THDH28-2
HGUS28-2
(10) - I6d (Joist)
(12) -16d (Joist)
(36) - 16d (Face)
(36)-16d trace)
-
T13
THDH28-3
HGUS28-3
(10) - 16d (Joist)
(12) -16d (Joist)
pr�s
U 1
STRUCTURAL 1hi-14, CONNECTORS"
A MiTeW Company
JUS24
JUS26
zzp
LN
TIM
V1,2
THD26
THD26-2
THD28
N
A,
�47
M,
THD28-2
THD46
THDH26-2
4.
-2
r o
x
0,
ITHDH26-3
THDH28-2
THDH28-3
REPAIR REQUESTS
When sending in repair requests, please use engineering sheets to describe issue or damage, and email to design@altruss.com.
NOTE: It is appreciated if actual pictures of the damage or problem are included with the engineering sheet, but pictures by themselves are usually not very
helpful. Engineering sheets with the damage or issue noted are required.
1. If there are any special circumstances (sheeted, trades in, etc,) please make sure you note it on the drawing or email request.
2. We cannot provide sealed drawings for "field built" trusses.
2. See details below.
Y
AL'R E9DVED BEARING.CONDIliON
'TRUSS MODIFICATION:
u.
BREAKS Usea iieto rsse
'rcedasdei2�Wdas"
R, urdmrr
(J
V78
nsrorisaS needed.
=
4x6II `
x3 II
3x3= - FP= 3x3II
5x4 (I1.5x411
_ v
`-:5x81
:
r'2
3 4 ;6'
S
10. 11
12 01
1
P.
SSi
BI
to
II
22'
21
20 19 i 1
17 16; 15
14,
7.112!,' =
�1
TOO LONG
1.5X4It
3x6=
1.5x4 11 1.5x4 (I 121 3z6 =
US FP= 3x4 = .3x3 =
4x6 =
R
;F
ti
MEMEER SPLIT'
,Z
Derso 11e1. €(aeatrgn,o6p[itand
l BREAISS dsealtlteDIV
`
:-pravtde an approximatelength
theexact.(ocatlonal-tt
_
..MISSING PIECE .ifth6reare
multiple breaks msufttftq in a
"
3z4
3x4 �
se>:tlorirrussinq;
-
"r MiSSINGiDAMAiGEDPL"ATES:
s
.' .. .-
U6
5 "'
-Circle plate that needs addressed-,
3x
5k4\� 4'
-$
3`
3`
W
2
V
e
9-
r
g:
2
ry
...N re.i•4`k:�'n:xN Rt.-:�iih+trc .w..: `MT5 k'.d .t--w H,A
,,,,13ntrcn. .�o... ...a. ,vi ".r�t. e.. N:;:Y'�n`i,en.ys vJ+Yy'1W&,H .MM .. .te'.v'.ti'r. „'tt .vP?tP�Y:t:Sxt 14 i.}NX'�nn. sA�nS .:fivm. .#F°�:�Y §{.,:.. X.. "n. h:uC
.:,.'�
14