HomeMy WebLinkAbout16-22kw specsINCLUDES:
• True Powel Electrical Technology Mode
• Two Line LCD Multilingual Digital
Evolution'" Controller (English/Spanish/ Model
French/Portuguese) Model
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
• Electronic Governor
• System Status & Maintenance Interval LED Indicators
• Sound Attenuated Enclosure
• Flexible Fuel Line Connector
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Capability to be installed within 18" (457 mm)
of a building*
FEATURES
C INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of
GENERAC'S success in "IMPROVING POWER BY DESIGN." But it doesn't
stop there. Total commitment to component testing, reliability testing,
environmental testing, destruction and life testing, plus testing to applicable
CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC
POWER SYSTEMS with the confidence that these systems will provide superior
performance.
0 TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5%Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
0 TEST CRITERIA:
r PROTOTYPE TESTED . NEMA Ill EVALUATION
• SYSTEM TORSIONAL TESTED . MOTOR STARTING ABILITY
GENERAC°
GUARDIAN® SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
s G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz
s G00703&q G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
s GOO/ 043-Q G007042-0 (Aluminurn - Bisque) - 22 kW 60 Hz
r/ -
GENERAC'
wrairsedge
c &s QUIET-fES-T
LISTED
Note: CUL certification only applies to unbundled units and units packaged with limited circuit
switches. Units packaged with the Smart SWltch are UL certified in the USA only.
*Only if located away from doors, windows and fresh air intakes, and unless other-
wise directed by local codes.
0 SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-
of-the-art power maximizing regulation system is standard on all General models. It
provides optimized FAST RESPONSE to changing load conditions and MAXIMUM
MOTOR STARTING CAPABILITY by electronically torque -matching the surge
loads to the engine. Digital voltage regulation at±1%.
0 SINGLE SOURCE SERVICE RESPONSE from General's extensive dealer network
provides parts and service know-how for the entire unit, from the engine to the
smallest electronic. component.
0 GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous
with GENERAC POWER SYSTEMS. One reason for this confidence is that the
GENERAC product line Includes its awn transfer systems and controls for total
system compatibility.
Lu GENERAC a1�36<,o
P R 0 M I S E ®e `0' M°b'le
cra � Link �
MEP <flpp
Bu/ry In lie USAYsmg tlomesllcanOhmlgn Darts.
GENERAC®
16/20/22 kW
features and benefits
Engine.
..
•Generac (OHVI) design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma molt' rings
helps the engine run cooler, reducing oil consumption resulting in longer engine life.
• Quiet Test"
Greatly reduces sound output and fuel consumption during bi-weekly exercise.
•"Spiny-lok" cast Iron cylinder walls
Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
• Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life.
Now featuring up to a 2 year/200 hour oil change interval.
-Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
-High temperature shutdown
Prevents damage due to overheating.
Generator
• Revolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
-Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
-Displaced phase excitation
Maximizes motor starting capability.
-Automatic voltage regulation
Regulatestheoutput voltage to±l%prevents damaging voltage spikes.
• UL 2200 listed
For your safety.
Transfer Stvitoh
a
-Fully automatic
Transfers your vital electrical loads to the energized source of power.
-Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
• NEMA 3R
Can be Installed inside or outside for maximum flexibility.
Evolution— Controls
-Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication In any condition.
-Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
-Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
• Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80%pick-up, of standard voltage.
-Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
-Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
-Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds,
• Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
• Programmable exerciser
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5
minutes every other week. Also offers a selectable setting forweekly or monthly operation providing flexibility and
potentially lower fuel costs to the owner.
-Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
-Electronic governor
Maintains constant 60 Hz frequency.
Unit
-SAE weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up
to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance
items. Electrostatically applied textured epoxy paint for added durability.
-Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
-Small, compact, attractive
Makes for an easy, eye appealing installation, as close as 181 away from a building.
Installation Systern
_....
•1 ft (305 mm) flexible fuel line connector
Absorbs any generator vibration when connected to rigid pipe.
•Direct-to-dIrt composite mounting pad
Complex lattice design prevents settling or sinking of the generator system.
• Integral sediment trap
Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
GENERAC®
16/20/22 kW
specifications
Generator
Model
6007035-0, G007036-0,
G007038-0, G007039-0
G007042-0, G007043-0
G007037-0 (16 kW)
(20 kW)
(22 kW)
Rated Maximum Continuous Power Capacity (LP)
16,000 Watts'
20,000 Watts'
22,000 Watts'
Rated Maximum Continuous Power Capacity ING)
16,000 Watts'
18,000 Walls"
19,500 Watts'
Rated Voltage
240
240
240
Rated Maximum Continuous toad Current— 240 Volts (LP/NG)
66.6/66.6
83.3/75
91.6/81.3
Total Harmonic Distortion
Less thera5%
Less than 5%
Less than 5%
Main Line Circuit Breaker
70 Amp
100 Amp
100 Amp
Phase
1
1
1
Number of Rotor Poles
2
2
2
Rated AC Frequency
60 Hz
60 Hz
60 Piz
Power Factor
1.0
1.0
1.0
Battery. Requirement (not included)
12 Volta, Group 268 540£CA Minimum or Group 35AGM650
GOA Minimum
Unit Weight(lb/kg)
409/186
448/203
466/211
Dimensions (L.x-W x:H) Nmm
48 x 25 x 29/1218 x 638x 732
Sound output in dB(A) at 23 0 (7 m) with generator operating at normal load'"
66
66
67
Sound output in di at 23IT (7 m) with generator in Quiet Test" low -speed
exercise mode""
58
58
58
Exercise duration
5 min
5 min
5 min
Engine
-"
Type of Engine.
GENERAC OHVI V-TWIN
GENERAC OR V-TWIN
GENERAC OHVI V-TWIN
Number of Cylinders
2
2
2
Displacement
999 cc
999ec
999ec
Cylinder Block
Aluminum w/ Cast Iron Sleeve
Valve Arrangement
Overhead Valve
Overhead Valve
Overhead Valve
Ignition System
Solid-state w/ Magneto
Solid-state w/ Magneto
Solid-state w/ Magneto
Governor System
Electronic
Electronic
Electronic
Compression Ratio
9.5:1
9.51
9.5:1
Starter
12Vdc
12Vde
12Vote
Of Capacity Including Filter
Approx. 1,9 q /1.8 L
Approx. 1.9 gV1.8 L
Approx. 1,9 cl L
Operating rpm
3,600
3,600
3,600
Fuel Consumption
Natural Gas fle/hr (all
1/2 toad
193 (5.47)
205 (5.8)
184 (5.21)
Full toad
Liquid Propane 03/hr (gal/hr) [Vhr]
312 (8.83)
308 (8.72)
281 (7.96)
112 Load
69 (1.9) F.2]
81 (2.23) [8.45]
70 (2.16) [8,16]
Full Load
116 (3,19) [12.071
140 (3,85) 114,571
134 (3.68) [13 941
Note: Fuelpipe most be sized for full load. Required fuel pressure to generator fuel Inlet
at all lead ranges - 3.5-7" water column. (7-13 min mercury) for natural W.
10-12" water column (19-22 min
mercury) for LP gas. For Btu content, multiply ft3mr x2500 (LP) or 83/m x 1000.(ND. For Megaloule content, multiply.mpmr
x 93.15 (LP) or ri x 3726.(NG)
Controls
2{ine Plain Text Multilingual LCO:Display
Made Buttons: Auto
Manual
Off
Ready to Run/Mampenance Messages
Engine Run Hours Indication
Programmable Stan delay between: 2-15OG seconds
Utility Voltage Lose/Return to Utility Adjustable (Brownout Setting)
Future SetCapadle Exerciser/Exercise Set Error Warning
Rim/Alarm/Maintenance Logs
Engine Skirt Sequence
Starter Lock -out
Smart Battery Charger
Charger FaulVMissing AC Warning
LOW Battery/Battery Pietism Protection and Battery Condition Indication
Automatic Voltage Regulation with Over and Under Voltage Protection
Under-Frequency/OveraaNStepper OvermfirenCProtection
Safety Fused/Fuse Problem Protection
Automatic Low Oil Pressure7High Oil Temperature Shutdown
OvercranVOverspeed (@ 72 Hzl/rpm Sense Loss Shutdown
High Engine Temperature Shutdown
Internal FaulVlncorrect mining Protection
Common External Fault Capability
Field Upgradable Firmware
Simple user Interface for sees of operation.
Automatic Start on Utility failure.7 day exerciser.
Starr with starter cdni unit stays on, If utflirylafls, transfer to lead takes place.
Stops unit. Power is removed. Control and charger still operate.
Standard
Standard
Standard (programmable by dealer only)
From 140-171 V/190-216 V
Standard
50 Events Each
Cyclic cranking:16 sec on 7 rest (90 sec maximum duration).
Starter cannot re-engage until 5 sec after engine has slapped.
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
-Sound levels ere men Rom we Mont of Me gereat goal lawns loan Irom other sides of the generanor may be higher Meant on Inagooks on parameters. Rating definilions-Sooner Applicabk for supplpng emergency power nor to barren
oftheuriyponroutage. Nooverlood Upabiliy lsmeilablelorthlsoll (All ratingsinanordancewllha$5519, IS03046and WN6271).'Veteran wattage andcurmrl sublscllo and ranged by nude Mrs askel Btuhnegajeule mhoonal
ambient temperature, altitude, engine power are cwmalao, ea. 64axlmwn pncertlecraaysaboN35 percemnor eacA 1,000 Mel jl04B meters) shore sea lerel; and also will decreaseabM 1 percem for each 6 °C (10 °r� shore 16 °C (60 °F).
GENERAC'
16/20/22 kW switch options
Limited ulrcuit Svji ch
Model
G007036-0 (16 kW)
• 16 circuits.
No. of Poles
2
• Electrically operated, mechanically -held contacts for fast, positive connections.
Current Rating (Amps)
Voltage Rating (VAC)
100
120/240,10
• Rated for all classes of load,100% equipment rated, both inductive and resistive.
Utility voltage Monitor (Fixed)'
• 2 pole, 250 VAC contactors.
-Drop ut
65%
• 30 millisecond transfer time.
Return to utility'
approx. 15sec.
Exercise hi -weekly for 12 minutes'
Standard
• Dual coil design.
UL Listed
Standard
• Rated for both copper and aluminum conductors.
Total of Pre -wired Circuits
No.15 A 120 V
16
5
• Main contacts are silver plated or silver alloy to resist welding and sticking.
No. 20 A120V
5No.
20 A 240 V
1
• NEMA 39 aluminum outdoor enclosure allows for indoor or outdoor mounting
No. 30 A 240 V
-
flexibility.
No. 40A240V
1
No. 50 A 240V
1
• Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers from
Tandem Breaker Capability
6 spaces
Siemens, Murray, Eaton and Square D for the most flexible and cost effective install.
circuit Breaker Protected
Available RMS Symmetrical
Fault Current 250 Volts
10.000
'Function of Evolution Controller
Exercise can be set to weekly or monthly
Dimensions 200 Amps 120/240, 1n
Open Transition Service Rated
Height Width Depth
H1 rH2 Wt I W2
in 27.24 30.0 11.4 1 13. 1 7.09
mm 692.0 762.4 289.0 343.0 180.0
Wire flanges '
Conductor lug Neutral W Ground LugL
210-#14 2/0-#14 2tO-#14
Service Rated Smart Switch Features
• Includes Digital Power Management Technology standard (DPM).
Model
• Intelligently manages up to four air conditioner loads with no
No. of Poles
additional hardware.
Current Rating (Amps)
• Up to four more large (240 VAC) loads can be managed when used in
Voltage Rating: (VAC)
Utility voltage Monitor (Fixedl'
conjunction with Smart Management Modules (SMMs).
-Pick-up
• Electrically operated, mechanically -held contacts for fast, clean
-Dropout
connections.
Return to utility'
• Rated for all classes of load,100% equipment rated, both inductive and
Exercise weekly for 12 minutes'
resistive.
UL Listed
• Up to four more large (120/240 VAC) loads can be managed when used in
Enclosure Type
Withstand Rating (Amps)
conjunction with 50 amp Power Management Modules (PMM"').
Lug Range
• 2 pole, 250 VAC contactors.
'Function of Evolution Controller
• Service equipment rated, dual coil design.
• Rated for both aluminum and copper conductors.
• NEMA 313 aluminum outdoor enclosure allows for indoor or outdoor
mounting flexibility.
• Main contacts are silver plated or silver alloy to resist welding and
sticking.
Dimensions
200 Amps 120/240, 1e
Open Transition Service Rated
He?'t
WidN
N1
H2
I Wt
W2
Depth
in
27.24
30.0
1 11.4
13.5
7.09
mm
692.0
1 762.4
1 289.0
343A
180.0
G007037-0 (16 kW)/13007039-0 (20 kW)/
G007043-0 (22 kW)
2
200
120/240, 10
80%
65%
approx. 13 sec.
Standard
Standard
NEMA/UL 3R
22,000
250 MCM - #6
GENERACe
16/20/22 kW
available accessories
Model# Product
Description
Generac's Mobile Link allows you to check the status of your generatorfrom anywhere that you have
- G006463-3 Mobile Link-
access to an Internet connection from a PC or any smart device. You will even be notified via e-mail '-
or text message when a change in the generators status occurs. Available in the U.S. only.
G005819-0 26R Wet Cell Battery
' Every standby generator requires a battery to start the system. Generac offers the recommended 25R
wet cell battery for use with all air-cooled standby product (excluding. PowerPact®).
0007101-0 ` Battery Pad Warmer
The pad warmer rests under the battery. Recommended for use rf the temperature regu lady falls
below 0°F. (Not necessary for use with AGM -style batteries).
- G007102-0 . Oil Warmer
Oil warmer slips directly overthe oil filter. Recommended for use if the temperature regularly
falls below 0°F.
G007103-0 Breather Warmer
The breather warmer is for use In Extreme cold weather applications. For use with Evolution
controllers only in climates where heavy Icing occurs.
G005621-0 Auxiliary Transfer Switch Contact
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical
_ Kit
load you may not need. Not compatible with 50 amp pre -wired switches.
G007027-0 -Bisque Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers
(Standard on 22 kW)
a sleek, contoured appearance as well as offering protection from rodents and insects by covering the
-
lifting holes located in the base.
If the generator enclosure is scratched or damaged, it is importsntto touch-up the paint to protect
G005703-0 -Bisque Paint Kit
from future corrosion. The paint kit Includes the necessary paint to properly maintain or touch-up a
generator enclosure.
G006485-0 -16, 20 8 Scheduled Maintenance Kit
22 kW
Generac's scheduled maintenance kits provide all the hardware necessary to perform complete
routine maintenance on a Generac automatic standby generator.
G006873-0 Smart Management Module
Smart Management Modules are used in conjunction with the Automatic Transfer Switch to
(50 Amps)
increase its power management capabilities. It provides additional power management flexibility
-
not found in any other power management system.
dimensions & UPCs
Dimensions shown are approximate. Rehr N installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.
C
tie.5 iN
Q
Oil
f1�
B
swa im
FRONTNEW
Model
UPC
G007035-0
696471070354
0007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007040-0
696471070408
G007042-0
1 696471070422
G007043-0
696471070439
GENE RAC" Generale Power systems, Inc. • S45 W29290 HWY.. 59, Waukesha, WI 53189 • generac-corn
02016 Generac Power Systems, Inc. Ali rights reserved. All specurcaaons am subject to change without npdce. autle6n 10000000194-a 05/18/16