HomeMy WebLinkAboutSurvey Plot Plans\ 59
\ VACANT
\ 58
VACANT
_ \ BENCHMARK`
\ SANITARY MANHOLE
RIM EL=16.41'
N.A.V.D. 1988
- , .,..� `• SET 5/8" IR, �p00
LB 4286 (TYP)
a 6 57
\Oir PROPOSED PROPOSED
..' WATER �" AC PAD MODEL 1756/A
44 SERVICE F.F.E.=18.60 p0
GARAGE F.F.E.=18.00 �p
EXISTINGBUILDINGPAD EL--19.25
16� rn� PROPOSED O
V, oO�pFt COVERED
\ J - �' ENTRYLO
LS. h• 3 2a ,p6;5� 1^
00.
19,
o0 SANITARY 0-
\\ \ 6��e f O•f'� oo �i3` \ SERVICE 56
a' VACANT
\ \ p 0� Y
SET 5/8" IR/C
LB 4286 (TYP)
LEGEND & ABBREVIATIONS
BB DENOTES BEARING BASE
CBS DENOTES CONCRETE BLOCK STRUCTURE
CD DENOTES CHORD DISTANCE
CB DENOTES. CHORD BEARING
rk DENOTES CENTER LINE
D.E. DENOTES DRAINAGE EASEMENT
F.F.E DENOTES FINISH FLOOR ELEVATION
FND DENOTES FOUND
IR/C DENOTES IRON ROD AND CAP
LB. DENOTES LICENSED BUSINESS
L DENOTES ARC LENGTH
N/D DENOTES NAIL AND DISK
O.S.T. DENOTES OPEN SPACE TRACT
P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER
P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR
R DENOTES RADIUS
R/W DENOTES RIGHT OF WAY
U.E. DENOTES UTILITY EASEMENT
W.Y.T. DENOTES WATER MANAGEMENT TRACT
p DENOTES INCLUDED ANGLE
--V.` DENOTES DRAINAGE FLOW
�5 DENOTES PROPOSED ELEVATION
AREA SUMMARY IN SQUARE FEET
SOD:4,860 t
DRIVEWAY/WALKWAY.803 t
.KmFR-.:
(Digitally signed by
: Thomas P Kiernan
_Date: 2020.07.01
ss
/ 14:23:40-04'00'
THOMAS P. KIERNAN
Professional Surveyor & Mapper
Florida Certificate No. 6199
DATE
J
GRAPHIC SCALE
5/8" IR/C 20 a Ta 20
4286 (TYP)
LINK
1�h- eB e.
ZONE
LEGAL DESCRIPTION
Being all of Lot 57, according to the plat of CREEKSIDE PLAT NO. 4, as
recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida.
I _ f Containing 0.176 acres, more or less.
SET 5/8" IR/C
LB 4286 (TYP)
PROPERTY ADDRESS
3210 TRINITY CIRCLE, FORT PIERCE, FLORIDA
f GENERAL NOTES 7P00
1. The last date of field work was 06-14-19
2. Additions or deletions to survey maps or reports by other than the signing party or
parties is prohibited without written consent of the signing party or parties.
3. Reproductions of this map are not valid without the original signature and raised seal of
a Florida Licensed Surveyor and Mapper.
4. Lands shown hereon were not abstracted by this office for rights —of —way, easements .of
record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information
should be obtained through appropriate title verification.
5. All above ground fixed improvements, if any, have been located and- shown hereon.
6. Underground foundations and improvements were not located as part of this survey.
7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.9, according to
the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February
16, 2012. The exact designation can only be determined by an elevation certificate. No
additional search of the public records has been preformed. There may be additional map
Amendments affecting this property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel
and the use of existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the
center line of Trinity Circle which bears North 29'11'06" West and all bearings are relative
thereto.
10. No easements are shown hereon other than those depicted on the plat. No search of
the public records has been performed to find additional easements that may exist.
11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
12. The building setbacks shown hereon, although based on the best available information, are
not certified to and must be verified prior to design or construction.
13. All improvements relating to this plat are either proposed or under construction.
ADDED EXISTING BUILDING PAD ELEVATION GLM 7-01-2020
Boundary, Topographic &
Site Plan Survev-Lot 57
For: D. R. HORTON
te:5-141.004.057 Dd
1-12-2019
- CULPEPPER &
FB: N
�' /"
TERPENING INC
SCALE 1"=20'
DRAWN BY: GLM
2� 2980 SOUTH 250 STREET. FORT PIERCE, FLORIDA 3 981
N
FIELD: PK
PHONE T24643537 . FAX TT2 94197 - w vw n9.wm
STATE OF FLORIDA BOARD OF PROFESSIONAL
ENGINEERS AUTHORIZATION NO.120E