HomeMy WebLinkAboutcalcsFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 12 1402 B LHG Bed4 - E (COUNTY LOT 7)
Builder Name: CENTURY COMPLETE
Street: 5801 Eastwood Dr
Permit Office: ST LUCIE
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner: CENTURY COMPLETE
Jurisdiction: 661000
Design Location FL, ST_LUCIE_CO_INTL
County: St Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1408 0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=13.0 1108 00 ft'
b. Frame - Wood, Adjacent
R=13.0 300.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft'
5. Is this a worst case? No
10 Ceiling Types (1400.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1400.00 ft'
6. Conditioned floor area above grade (ft2) 1400
b N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7 Windows(122.8 sqft.) Description Area
a Sup: Attic, Ret: Main, AH: Main
6 280
a. U -Factor: Dbl, U=0.35 122.78 ft2
SHGC: SHGC=0.29
b. U -Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a Central Unit
178 SEER:14.00
c. U -Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U -Factor: N/A ft2
a. Electric Heat Pump
17.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft
Area Weighted Average SHGC: 0.290
14. Hot water systems
a. Electric
Cap: 50 gallonsEF:
8. Floor Types (1400.0 sqft.) Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1400.00 ft2
b. Conservation features
0.920
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.088 Total Proposed Modified Loads: 46.85
PASS
PASS
Total Baseline Loads: 47.21
1 hereby certify that the plans and specifications covered by
Review of the plans and0
114E ST,q,1
this calculation are in compliance with the Florida Energy
specifications covered by this
,y
Code. M9ttauysignedbySTEVE
STEVE ROGERS
calculation indicates compliance
,. _ �+
'��*�„ ,!
RflGEAS
with the Florida Energy Code.
� +rrr1R'�`'-�' � D
Date: 2020.05 1914:36:01 -04'00'}
PREPARED BY: -
Before construction is completed
+�
� �-
DATE- ...
this building will be inspected for
compliance with Section 553.908
Statutes.
r�
.
I hereby certify that this buil ng, s de igned, is in compliance
Florida
with the Florida Energy Code.
OWNER/AGENT
BUILDING OFFICIAL: _
DATE: _. __._ -
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/19/2020 2:32 PM EnergyGauge® USA 6.0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
PROJECT
Title:
Lot 12 1402 B LHG Bed4 - E (
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1400
Lot #
12
Owner Name:
CENTURY COMPLETE
Total Stories: 1
Block/Subdivision:
LAKEWOOD PARK
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
CENTURY COMPLETE
Rotate Angle: 270
Street:
5801 Eastwood Dr
Permit Office:
ST LUCIE
Cross Ventilation: No
County:
St Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Single-family
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
{
Design Temp
Int Design Temp Heating
Design Daily Temp
�f Design Location TMY Site
97.5% 2.5%
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299
58 Medium
BLOCKS
Number
Name Area
Volume
1
Block1 1400
11200
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main 1400
11200 Yes 5
4
1 Yes
Yes Yes
FLOORS
Floor Type Space
Perimeter R -Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 138.5 ft
1400 ft'
_
0.29 0 0.71
ROOF
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
#
Type Materials
Area Area Color
Barr
Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1475 ft2 232 ft' Dark
N
0.6 N 6
No 0 18.4
ATTIC
/
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 300 1400 ft'
N N
CEILING
#
Ceiling Type
Space R -Value Ins Type
Area Framing Frac Truss Type W
1
Under Attic (Vented)
Main 30 Blown
1400 ft2 0.1
Wood
5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
5/19/2020 2:32 PM EnergyGauge® USA 6.0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar Below
Crit_ To W�TypP Space R -VALE. Et in Et
rn__ Area
R -Value. Fraction .Absor-Grade%-
1 N=>W Exterior Frame - Wood Main
13 37 0 8
0 296.0 ft2
0
0.25 0.5
0
2 E=>N Exterior Frame - Wood Main
13 51 0 8
0 408 0 ft2
0
0.25 0.5
0
3 S=>E Exterior Frame - Wood Main
13 16 C 8
0 132.0 ft2
0
0.25 0.5
0
4 W=>S Exterior Frame - Wood Main
13 34 0 8
0 272.0 ft2
0
0.25 05
0
5 -SW Garage Frame - Wood Main
13 37 6 8
0 300.0 ft2
0
0.25 0.5
0
DOORS
V
# Ornt Door Type Space
Storms
U -Value
Width
Height
Area
Ft
In
Ft In
1 -SW Wood Main
None
.39 2
8
7
18.7 ft2
2 S=>E Insulated Main
None
.46 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation (=>) changed to As Built rotated 270 degrees)
/
Wall
Overhang
V
# Ornt ID Frame Panes NFRC
U -Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1 N=>W 1 Vinyl Low -E Double Yes
0.35 0.29 N
17.8 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
2 n=>W 1 Vinyl Low -E Double Yes
0.35 0.29 N
45.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
3 e=>N 2 Vinyl Low -E Double Yes
0,35 0.29 N
15.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
4 S=>E 3 Vinyl Low -E Double Yes
0.35 0.29 N
30 0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
5 W=>S 4 Vinyl Low -E Double Yes
0.35 0.29 N
15.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 408 ft2 408 ft2
48 ft
8 ft
1
INFILTRATION
#
Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) 000356
1306.7 71 73 134.91 .1233
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.2
17.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/ Split
Singl SEER: 14 17.8 kBtu/hr 534 cfm
0.75 1
sys#1
5/19/2020 2:32 PM EnergyGauge® USA 6.0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
HOT WATER SYSTEM
V #
System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1
Electric
None
Main
0.92
50 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
V FSEC
Collector
Storage
Cert #
Company Name
System
Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
/
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
#
Location R -Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 280 ft2
Main
70 ft2
Proposed Qn
Main
--- cfm
70.0 cfm 0.05
050
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinHJan
[[ ]Feb
[X� Feb
jj jj Mar
jXj Mar
j
j
j Apr [
j Apr j
] May
] May
X] Jun rl Jul
4 j Jun Jul
Au
jXj Au
X] Se
] Sep
Oct
Oct
Nov
Nov
Dec
Dec
Ventin Jan
[[ ] Feb
[[X]] Mar
[X]
A r [
j Ma
[ ] Jun Jul
Aug[
] Se
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
g
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/s .ft.
0 ft2
0 ft
0.3
Main
5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 5801 Eastwood Dr Permit Number:
Fort Pierce , FL , 34951
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
❑ R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display
card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section
553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold
residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a
dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and
specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveld-on building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with
the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the
code official, an approved third party shall inspect all components and verify compliance.
P—Y R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
L� changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using
tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air IeakagdNndows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open. combustion air ducts provide combustion air if) open
combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a
room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table
R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R -value requirement. The door into the room shall be fully
gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1 Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between
conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than
2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be
sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403 2 9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553 993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free' in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of
the design airflow rate when tested in accordance with ASHRAE 193
{1 R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manuf,
air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturers air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or
below 557 (13`C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused
by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the
material. Adhesive tape shall not be permitted
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe
❑ shall be a dedicated return pipe or a cold water supply pipe Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically tum off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
F-1 automatically
Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 Y: inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting
range shall be from 100°F to 140°F (38°C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table
C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category Solar water heaters shall meet the criteria of Section R403.5 6.2.1
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM -1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
EJ ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
El shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor
units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in
Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect
equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as
standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating
equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMUIV
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In-line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916
5/19/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than
the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section
403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall
not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements
calculated according to the procedure selected in Section R403.7.1.
El
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403 7 1
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403
El and C404 of the IECC—Commercial Provisions in lieu of Section R403.
p -i R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
F]R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall
be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of
such switch shall not change the setting of the heater thermostat Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section
Exceptions:
1. Where public health standards require 24-hour pump operation
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with
AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature A test report from an independent laboratory is required to
verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas (Mandatoryl�e energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
❑ R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights.
5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy
Performance Index,
the more efficient the home.
1 New home or. addition
1. New From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3 No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
17.8
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq ft.)
6. 1400
d) Room unit/PTAC EER
e) Other
7 Windows, type and area
a) U-factor:(weighted average)
7a. 0.350
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.290
14. Heating system: Capacity
17.6
c) Area
7c. 122.8
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R -value)
9a. 0.0
b) Wood, raised (R -value)
9b.
15. Water heating system
c) Concrete, raised (R -value)
9c
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10 Wall type and insulation:
c) Gas fired, LPG EF
A Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R -value)
10A1. 13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R -value)
10A2.
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R -value)
1061 13.0
2. Masonry (Insulation R -value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
1 la. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has.eomplied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will b�completed a*d oraA stalled Mode compliant features.
r'
Builder Signature: Date-
. f
Address of New Home: 5801 Eastwood DF City/FL Zip: Fort Pierce. FL 34951
5/19/2020 2:33:01 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Project Summa Job: Lot 12 1402 B LHG Bed4 - E
ro, Summary wrightsoftm Date: 05/19/2020
House %r ww►sR
One Stop Cooling and Heating Plan: LHG
7225 Sandscove Court, Winter Park. FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwm..OneStopCooling corn License: CAC032444
For: WADE JURNEY
5801 Eastwood Dr, Fort Pierce, FL 34951
Notes:
Weather:
Winter Design Conditions
Outside db 41 °F
Inside db 68 °F
Design TD 27 °F
Heating Summary
Outside db
Structure
14215
Btuh
Ducts
1210
Btuh
Central vent (0 cfm)
0
Btuh
(none)
59 grAb
n
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
15425
Btuh
Infiltration
St Lucie Cc Inti, FL, US
Summer Design Conditions
Outside db
90 °F
Inside db
74 °F
Design TD
16 of
Daily range
L
Relative humidity
50 %
Moisture difference
59 grAb
Sensible Cooling Equipment Load Sizing
Structure
11362
Btuh
Ducts
2343
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturers data
n
Central vent (0 cfm) 0 Btuh
RatelsWin multiplier
Equipment sensible load
0.95
13074
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
1 (Average)
Structure 3324 Btuh
Heating output
17600 Btuh @ 47°F
Ducts 523 Btuh
4450
Btuh
Central vent (0 cfm) 0 Btuh
Heating
Coolie
(none)
Area (ftp) 1449
1449
Equipment latent load 3848 Btuh
Volume (ft') 11594
11594
cfm
Air changesfhour 0.68
0.30
Equipment Total Load (Sen+Lat) 16922 Btuh
Equiv.AVf= (cfm) 132
58
Req. total capacity at 0.75 SHR 1.5 ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
in H2O
Make Carrier
Trade CARRIER
Load sensible heat ratio
Trade CARRIER
Model CH14NBO18000OA0
Capacity balance point = 37 °F
Cond CH14NBO1800GOA0
AHRI ref 9162108
Coil FB4CNP018L
AHRI ref 9162108
Efficiency
8.2 HSPF
Efficiency 11.5 EER, 14 SEER
Heating input
Sensible cooling
13350
Btuh
Heating output
17600 Btuh @ 47°F
Latent cooling
4450
Btuh
Temperature rise
0 °F
Total doling
17800
Btuh
Actual air flow
0 cfm
Actual air flow
593
cfm
Airflowfactor
0 cknBtuh
Airflowfactor
0.043
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.78
Capacity balance point = 37 °F
Backup:
Input =13 kW, Output= 43537 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
2020 -May -1914:14:46
,tet M• Right -Suite® Universal 2019 19 0 19 RSU16793 Page 1
ACC - . 2 B LHG Bed4- EtLot 12 1402 B LHG Bed4 - E rup Calc= MJ8 Front Doorfaces: E
wrightsoft, Right -J® Worksheet
House
One Stop Cooling and Heating
Job: Lot 12 1402 B LHG Bed4 - E
Date: 05/19/2020
WW/SR
Pan: LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwvwOneStopCooling oom License: CAC032444
1
Room name
House
KIT
2
Exposed wall
138 5 it
115 ft
3
Room height
8.0 ft d
8.0 It heat/cool
4
Room dimensions
17.0 x 11.5 ft
5
Room area
1449 3 ft'
195 5 ft'
Ty
Construction
U -value
Or
HTM
Area (ft)
Load
Area (ft)
Load
number
(BtuhAt'-°F)
(B A2)
or perimeter (ft)
(B h)
or perimeter (ft)
(Btuh)
Heat Cool
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cool
6
V,V
12C -09w
0 091
n
2.46 230
408
393
966
905
92
92
226
212
G
4A5-2ov
0 350
n
9.45 10.08
15
0
142
151
0
0
0
0
W
12C -09w
0 091
a
2.46 230
132
82
201
189
0
0
0
0
4A5-2ov
0 350
a
9.45 2858
30
0
283
857
0
0
0
0
11
D
11D0
0.390
a
10.53 1182
20
20
212
238
0
0
0
0
IhV
12C -09w
0.091
s
246 2.30
272
257
631
592
0
0
0
0
t -G
4A5-2ov
0 350
s
9.45 1024
15
13
142
154
0
0
0
0
W
12C-Osw
0 091
w
246 2.30
296
233
573
537
0
0
0
0
G10D-v
0 350
w
9.45 2001
18
0
169
357
0
0
0
0
G
4A5-2ov
0 350
w
9.45 28,58
45
0
425
1286
0
0
0
0
12C -09w
0 091
-
246 1.40
300
281
691
394
0
0
0
0
D
11 D0
0.390
n
10.53 11.82
19
19
197
221
0
0
0
0
C
1613-30ad
0032
086 172
1449
1449
1252
2495
196
196
169
337
F
22A-tpm
1 180
3186 000
1449
139
4413
0
196
12
366
0
6
c)AED excursion
292
-93
Envelopeloss/gain
10296
8667
761
456
12
a) Infiltration
3919
1045
325
87
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
5
1150
0
0
Appliances/other
500
500
Subtotal (lines 6 to 13)
14215
11362
1087
1043
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
165
123
14
Subtdal
14215
11362
1252
1166
Dudloads
90/(
21%
1210
2343
9%
21%
107
240
r
Total room load
15425
13704
1359
1407
Air required (dm)
0
593
0
61
Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed
A* 2020 -May -1914:14:48
-•--• Right-Suitee Unhwersa12019 19.0.'19 RSU16793 Page l
AC0K ...2 B LHG Bad4 - Elot 121402 B LHG Bed4 - E.rup Calc= MJB Frant Doorfarxs: E
wrightsoft° Right -M Worksheet
House
One Stop Cooling and Heating
Job: Lot 12 1402 B LHG Bed4 - E
Date: 05/19/2020
WW/SR
Pan: LHG
7225 Sandsowe Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444
1
Room name
FOY
MBA
2
Exposed wall
50 ft
55 it
3
Room height
8.0 ft heaV000l
80 ft heat/000l
4
Room dimensions
10 x 150.3 ft
110 x 55 ft
5
Room area
150 3 ft'
60 5 fF
Ty
Construction
U -value
Or
HTM
Area (ft')
Load
Area (ft')
Load
number
(Btuhd`--°F)
(BV)
or perimeter (ft)
(Bh)
or perimeter (ft)
(Btah)
Heat
Cod
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
%t12C-0sw
0 091
n
246
2 30
0
0
0
0
0
0
0
0
t G
4A5-2ov
0 350
n
945
10.08
0
0
0
0
00
0
0
IW
12C-Osw
0 091
e
246
230
40
20
49
46'
.0
(1
0
0
4A5-2ov
0.350
a
945
28.58
0
0'
0
0
0
(1
0
0
11
D
11DO
0.390
a
10.53
11.82
20
20
212
238
0
0
0
0
T—G
12C-Ow0
091
s
246
230
0
0
0
0
44!44
108
101
4A5-2ov
0 350
s
945
10.24
0
0
0
0
0
0'
0
0
IW
12C-Osw
0 091
w246
2.30
0
0
0
0
0
0
0
0
EI— 11
OD -v
0 350
w
945
2001
0
0
0
0
0
0
0
0
G
4A5-2ov
0 350
w
9.45
28.58
0
0
0
0
0
0
0
0
q—D
12C-Osw
0.091
-
246
1.40
216
197
485
277
0
0
0
0
11 DO
0 390
n
10.53
1182
19
19
197
221
0
0
0
0
C
1613-30ad
0 032
086
172
150
150
130
259
51
61
52
104
F
22A-tpm
1180
3186
0.00
150
5
159
0
61
6
175
0
6
c)AED excursion
-88
-20
Envelope losslgain
1231
951
336
185
12
a) Infiltraton
141
38
156
41
b) Room ventlaton
10
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliancestother
0
0
Subtotal (lines6 to 13)
1373
989
491
227
Less ex:L-mal load
0
0
0
0
Lesstransfer
0
01
0
0
Redistributon
-1373
-989
6
11
14
Subtotal
001
497
238
15
Ductloads
9%
21%
0
0
9%
21%
42
49
Total room load
0
0
540
287
Air required (cfm)
0
0
0
12
Calculations aDDroved NACCA to meet all reauirements of Manual J 8th Ed
-jr-gt,sof# 2020 -May -1914:14:48
.�- - — Right-Su+tP.=. Universal 2019 19.0.19 RSU16793 Page 2
'��` ...2 B LHG Bed4 - E%Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Door faces: E
wrightsoft- Right -JO Worksheet
House
One Stop Cooling and Heating
Job: Lot 12 1402 B LHG Bed4 - E
Date: 05/19/2020
WW/SR
Pan: LHG
7225 Sandscove Court, Wnter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vw .OneStopCooling com License: CAC032444
1
Room name
IMBED
LAUN
2
6posed wall
270 ft
O ft
3
Room height
80 ft heat/ood
80 It heaUcUol
4
Room dimensions
140 x 130 ft
60 x 4.0 ft
5
Room area
182 0 ft'
24 0 fF
Ty
Construction
U -value
Or
HTM
Area (ft')
Load
Area (W)
Load
number
(BbjW-°F)
(B AF)
or perimeter (ft)
(B h)
or perimeter (ft)
(13tuh)
Heat
Cool
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cod
6
12C-Osv
0091
n
2-46
230
0
0
0
0
0
O
0
0
4A5-2ov
0 350
n
945
1008
0
0
0
0
0
0
0
0
IW
12C-0sw
0 091
a
246
230
0
0
0
0
0
0
0
0
4A5-2ov
0.350
a
9.45
28.58
0
0
0
0
0
0
0
0
11
D
11 DO
0.390
a
10.53
11.82
0
0
0
0
0
0
0
0
T1
12C -09w
0.091
s
2.46
230
104
104
256
239
0
0
0
0
--C
4A5 2ov
0.350
s
9 45
1024
0
0
0
0
0
0
0
W
12C-0 sw
0 091
w
246
230
112
97
238
223
0
0
0
0
E0
OD -v
0 350
w
9.45
2001
0
0
0
0
0
0
0
O
4A5-2ov
0.350
w
9.45
28.58
15
0
142
429
0
0
0
0
q—D
12C-Osw
0-091
-
246
1.40
0
0
0
0
0
0
0
0.82
11 DO
0.390
n
1053
11
0
0
0
0
0
0
0
0
C
1613-30ad
0 032
086
172
182
182
157
313
24
24
21
41
F
22A-tpm
1.180
31.86
0.00
182
27
860
0
24
0
0
0
6
c)AED excursion
77
-3
Envelopeloss/gain
1653
1282
21
38
12
a) Inriltraton
764
204
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
2
460
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2417
1946
21
38
Lessextemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
3
6
-21
-38
14
Subtotal
2420
1952
0
0
15
Dudloads
9%
21%1
206
402
9%
21%
0
0
Total room load
2626
2354
1
0
0
Air required (cfm)
0
102
0
0
Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed
�* w. igFtitsol# 2020 -May -1914:14:48
Right -Suite -%Universal 2019199.19 RSU16793 Page 3
'40C:;P` ...2 6 LHG Bed4 - E+Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Doorfaces: E
wrightsoft' Right -JO Worksheet
House
One Stop Cooling and Heating
Job: Lot 12 1402 B LHG Bed4 - E
Date: 05/19/2020
Bgyy• WW/SR
Pfan: LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwwvOneStopCooling.eom License: CAC032444
1
Room name
BA2
2
Exposed wall
O ft
O ft
3
Room height
80 ft heat/000l
80 ft heaU000l
4
Room dimensions
6.0 x 8.5 ft
35 x 35 ft
5
Room area
51.0 ft'
12.3 ft=
Ty
Construction
U -value
Or
HTM
Area (ft2)
Load
Area (ft°)
Load
number
(BtuhA2--°F)
(B /F)
or perimeter (ft)
(B h)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
tq✓
12C-0swv
0 091
n
2.46
230
0
0
0
0
0
0
0
0
�G
4A5-2ov
0 350
n
9.45
1008
0
0
0
0
0
0
0
0
W
12C-Osw
0 091
a
246
2.30
0
0
0
(1
0
0
0
0
F—G
4A5-2ov
0.350
e
945
28.58
0
0
0
0
0
0
0
0
11
D
11 DO
0 390
a
1053
1182
0
0
0
(1
0
0
0
0
V�J
12C -09N0
091
s
2.46
230
0
0
0
0
0
0
0
0
t—G
4A5-2ov
0.350
s
9.45
10.24
0
0
0
0
0
0
0
0
W
12C-Osw
0091
w
246
230
0
0
0
0
0
0
0
0
E1OD-v
0350
w
945
20.01
0
0
0
0
0
O
0
0
4A5-2ov
0 350
w
945
2858
0
0
0
0
0
0
0
0
I—D
12C-Osw
0.091
-
246
1.40
0
0
0
0
0
0
0
0
1 1D
0.390
n
10.53'
11.82
0
0
0
0
0
0
0
0
C
166-30ad
0.032
0.86
1.72
51
51
44
88
12
12
11
21
F
221-tpm
1.180,
31.86
0.00
51
0
0
0
12
0
0
0
6
c)AED excursion
-7
-2
Envelopeloss/gain
44
81
11
19
12
a) Infiltration
0
0
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Applianceslother
0
0
Subtotal (lines6to 13)
44
81
11
19
Less external load
0
0
0
0
LesstransW
0
0
0
0
Redistribution
206
161
-11
-19
14
Subtotal
250
242
0
0
15
Ductloads
9°/<
21%
21
50
9%
21%
0,
0
Total room load
271
292
0
0
Air required (dm)
0
13
0
0
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
�}� wrightsaTt 2020 -May -1914:14:48
AC.-(ffA Right -Suite® Universal 2019 19.0 19 RSU16793 Page 4
.2 B LHG Bed4 - EtLot 121402 B LHG Bed4 - E.rup Calc= MJ8 Front Door faces: E
wrightsoft° Right -JO Worksheet
House
One Stop Cooling and Heating
Job: Lot 12 1402 B LHG Bed4 - E
Date: 05/19/2020
WW/SR
Pan: LHG
7225 Sandsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444
1
Room name
BED 2
BED 3
2
Exposed wall
120 ft
105 ft
3
Room height
80 ft heaV000l
8.0 ft heatbod
4
Roomdimensons
TO x 1418 ft
10 x 1418 ft
5
Room area
1418 ft'
1418 tt2
Ty
Construction
U -value
Or
HTM
Area (ft')
Load
Area (1F)
Load
number
(BtuhAt'--°F)
(B AF)
or perimeter (ft)
(B h)
or perimeter (ft)
(Btuh)
Heat Cod
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
µ1l
12C -09N
0 091
n
2.46 230
0
0
0
0
84
69
170 '
159
l_
4A5-2ov
0.350
n
9.45 10.08
0
0
0
0
15
0
142
151
IW
12C-Osw
0 091
a
246 230
0
0
0
0
0
0
0
0
4A5-2ov
0.350
e
945 2858
0
0
0
0
C
0
0
0
11
D
11 DO
0 390
a
1053 1182
0
0
0
0
0
0
0
0
µV
12C-Osw
0 091
s
246 2.30
96
81
199
186
0
0
0
0
L—G
4A5-2ov
0.350
s
945 1024
15
13
142
154
0
0
0,
0
W
12C -09m
0.091
w
246 230
0
0
0
0
0
0
0
0
1OD-v
0.350
w
9.45 2001.
0
0
0
0
0
0
0
0
G
4A5-2ov
0.350
w
945 28.58
0
0
0
0
0
0
0
0
12C-Osw
0 091
-
2.46 1.40
84
84
206
118
0
0
0
0
D
11 DO
0 390
n
10.53 11.82
0
0
0
0
0
0
0
0
C
16B-30ad
0 032
086 1.72
142
142
122
244
142
142
122
244
F
22A-tpm
1.180
3186 0.00
142
12
382
0'
142
11
335
0
6
c)AED e=rsion
-72
-70
Envelopeloss/gain
1052
630
768
484
12
a) Infiltration
340
91
297
79
b) Room ventilation
0
0
01
0
13
Internal gains: Occupants@ 230
1
23C
1
230
Appliancesbther
0
0
Subtotal (lines 6 to 13)
1391
95C
1065
793
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
140
112
565
407
14
Subhotal
1531
1062
1631
1200
15
Dudloads
9%
21%
130
219
9%
21%
139
247
Total room load
1661
1281
1769
1448
Airrequired (cfm)
0
55
0
63
Calculations aDDroved NACCA to meet all reauirements of Manual J 8th Ed
-jr-wrightsoit 2020 -May -1914:14:48
— - Right-SurteE Universal 2019 19.0, 19 RSU16793 Page 5
'CC;P` ...2 B LHG Bed4 - E1Let 12 1402 B LHG 3ed4 . E.rup Calc = MJ8 Front Door faces: E
wrightsoft' Right -JO Worksheet Job:
House °Bay�te`
One Stop Cooling and Heating Plan:
7225 Sandscove Court, VYnter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444
Lot 12 1402 B LHG Bed4 - E
05/19/2020
WW/SR
LHG
1
Room name
MVVIC
BED 4
2
Exposed wall
50 ft
290 ft
3
Room height
80 ft heaU000l
80 ft heaU000l
4
Room dimensions
50 x 90 ft
10 x 134 8 ft
5
Room area
45.0 fl?
134 8 ft'
Ty
Constructon
U -value
Or
HTM
Area (ft')
Load
Area (ft')
Load
number
(BtuhrR'-°F)
(B /W)
or perimeter (ft)
(B h)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
NIPS
Heat
Cod
Gross
N/P/S
Heat
Cod
6
\f12C-Osw
0.091
n
2,46
230
0
0
0
0
112
112
275
258.
C,
4A5-2ov
0.350
n
9.45
10.08
0
0
0
0
0
0
0
0
W
12C -09w
0 091
a
246
2.30
0
0
0
0
92
62
152
143
4A5-2ov
0 350
e
945
2858
0
0
01
0
30
0
283
857
11
D
11 DO
0 390
a
1053
1182
0
0
0'
0
0
0
0
0
L�V
12C-Ow0
091
s
246
2 30
0
0
0
0
28
28
69
64
L—G
4A5-2ov
0 350
s
9.45
10 24
0
0
0
0
0
0
0
0
W
12C-Ow0.091
w
246
2.30
40
40
98
92
0
0
0
0
1 OD -v
0 350
w
9.45'
20.01
0
0
0
0
0
0
0
0
4A5-2ov
0 350
w
9 45
28,58
0
0
0
0
0
0
0
0
L—D
12C -0s
0 091
-
2.46
1.40
0
0
0
0
0
0
0
0
11 DO
0.390
n
1053
11.82
0
0
0
0
0
0
0
0
C
16B-30ad
0.032
086
1.72
45
45
39
77
135
135
116
232
F
22A-tpm
1.180
-
3186
0.00
45
5
159
0
135
29
924
0
6
c)AED excursion
-17
139
Envelope lossrgain
296
153
1820
1694
12
a) Infiltration
141
38
821
219
b) Room ventilation
0
0
10
0
13
Internal gains: Occupants@ 230
0
0
1
230
Appliances/other
0
0
Subtotal (lines 6 to 13)
438
190
2641
2143
Less exlemalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
323
233
14
Subtotal
438
190
2964
2375
15
Dudloads
9%
21%
37
39
9%
21%
252
490
Total room load
478
230
3216
2865
Air required (dm)
0
10
0
124
Calculations awroved bvACCA to meet all requirements of Manual J 8th Ed
-Pk- wrigl #soft 2020 -May -1914:14:48
- --- Right-Sult-16' Universal 2019 19.0.1 O RSU16793 Page 6
lift ...2 B LHG Bed4 - E1Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Door tabes: E
+- wrightsoft, Right -JO Worksheet
House
One Stop Cooling and Heating
Job: Lot 12 1402 B LHG Bed4 - E
Date: 05/1912020
WW/SR
Pan: LHG
7225 Sandsmve Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444
1
Room name
LIVING
WH
2
Exposed wall
330 ft
O ft
3
Room height
80 ft heaU000l
80 ft heat/ood
4
Room dimensions
10 x 294 O ft
30 x 55 It
5
Room area
294.0 T
16.5 IF
Ty
Construction
U -value
Or
HTM
Area (ft')
Load
Area (ftp
Load
number
(BtuhAF--°F)
(B AF)
or perimeter (ft)
(B h)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
I Cool
6
kt12C-Osw
0 091
n
2.46
230
120
120
295
276
0
0
0
0
�G
4A5-2ov
0.350
n
945
1008
0
0
0
0
0
0
0
0
IW
12C-Osw
0 091
a
246
2.30
0
0
0
0
0
0
0
0
I—G
4A--,2.,,
0.350
a
9.45
2858
0
0
C
0
0
0
0
0
11
1D
11 DO
0 390
a
1053
11.82
0
0
C
0
0
0
0
0
12C-Osw
0 091
s
246
2.30
0
0
C
0
0
0
0
0
4A5-2ov
0 350
s
945
10.24
0
0
0
0
0
0
0
0
IW
12C-Osw
0 091
w
246
230
144
96
236
221
0
0
0
0
l OD -v
0.350
w
945
2001
18
0
169
357
0
0
0
0
I
G
4A5-2ov
0 350
w
945
2858
30
0
283
857
0
0
O
0
12C-0sw
0.091
-
246
1.40
0
0
0
0
0
0
0
0
D
11 DO
0.390
n
1053
1182
0
0
0
0
0
0
0
0
C
166-30ad
0 032
0.86
1.72
294
294
254
506
17
17
14
28
F
22A-tpm
1.180
3186
000
294
33
1051
0
17
0
0
0
6
c)AED excursion
450
-2
Envelopeloss/gain
2289
2668
14
26
12
a) Infiltration
934
249
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Applianoeslother
0
0
Subtotal (lines61o13)
3223
2917
14
26
Less external load
0
0
0
0
Less transfer
0
C
0
0
Redistribution
10
19
-14
-26
14
Subtotal
3233
2936
0
0
15
Dudloads
9%
21%1
275
605
9%
1 21%
0
0
Total room load
3508
3541
1
0
0
Air required (chm)
0
1531
0
0
Calculations woroved bvACCA to meet all requirements of Manual J 8th Ed
-r�F 2020 -May -19 14:14:48
- Right-Suite®Universal2019190 19RSU16793 Page
'CC�K ..2 B LHG Bed4 - E\Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Doorfaces: E
Duct System Summary Job: Lot 12 1402 B LHG Bed4 - E
wrightsoft, Date: 05119/2020
House By: WW/SR
One Stop Cooling and Heating Plan: LHG
7225 Sandscove Court, winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ew w..OneStopCooling corn License: CAG032444
For: WADE JURNEY
5801 Eastwood Dr, Fort Pierce, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply/ return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0
in H2O
0.16
in H2O
-0.2
in H2O
-0.080/-0.080
in H2O
-0.12
in/100ft
0
cfin
133 ft
Cooling
0.50
in H2O
0.16
in H2O
0.34
in H2O
0.170 /0.170
in H2O
0.256
in/100ft
593
cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
I (in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BA2
c 292
0
13
0.303
4.0
Oxo
VIFx
17.3
95.0
st1
BED2
c 1281
0
55
0.294
6.0
0x0
VIFx
20.6
95.0
st1
BED3
c 1448
0
63
0.301
6.0
0x0
VIFx
18.1
95.0
st1
BED4
c 2865
0
124
0.256
6.0
0x0
VIFx
27.9
105.0
st1
KIT
c 1407
0
61
0.291
6.0
Ox 0
VIFx
22.0
95.0
st2
LIVING
c 1771
0
77
0.292
5.0
Ox 0
VIFx
21.3
95.0
st2
LIVING -A
c 1771
0
77
0.275
5.0
Ox 0
VIFx
28.5
95.0
st2
MBA
c 287
0
12
0.290
4.0
Ox 0
VIFx
22.4
95.0
st2
IMBED
c 2354
0
102
0.286
6.0
Ox 0
VIFx
24.0
95.0
st2
MWIC
c 230
0
10
0.298
4.0
Ox 0
VIFx
19.2
95.0
st2
wrightsoft- 2020 -May -1914:14:49
^, „_, _ , Right -Suite® Universal 201919.019 RSU16793 Page 1
ACO, ...2 B LHG Bed4 - EtLot 121402 B LHG Bed4 - E rup Calc= 1VJ8 Front Doerfaees: E
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(dm)
(dim)
FR
(fpm)
(in)
(in)
Material
Trunk
st1
PeakAVF
0
255
0.256
577
9.0
0 x 0
VinlFlx
st2
PeakAVF
0
339
0.275
621
10.0
0 x 0
VinlFlx
wrightsoft- 2020 -May -1914:14:49
^, „_, _ , Right -Suite® Universal 201919.019 RSU16793 Page 1
ACO, ...2 B LHG Bed4 - EtLot 121402 B LHG Bed4 - E rup Calc= 1VJ8 Front Doerfaees: E
Name
Grille
Size (in)
Htg
(cfm)
Clg
(dm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mab
Trunk
rb1
0x0
0
593
0
0
0
0
Ox 0
VIFx
wrightsoft- 2020 -May -1914:14:49
A -L .,,., �,._ Right -Suite® Universal 2019 19.0 19 RSU16793 Paget
zr. 2 8 LHG Bed4 - E\Lot 121402 B LHG Bed4 - E.rup Calc= MJ8 Front Door faces: E
Static Pressure and Friction Rate Job: Lot 121402 B LHG Bed4 -E
wrightsoftm Date: 05/19/2020
House E,: WW/SR
One Stop Cooling and Heating Plan: LHG
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vawOneStopCooling com License: CAC032444
For: WADE JURNEY
5801 Eastwood Dr, Fort Pierce, FL 34951
Available Static Pressure
Heating Cooling
(in H2O) (in H2O)
External static pressure 0 0.50
Pressure losses
Coil
0
0
Heatexchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
010
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
Available static pressure
-0.2
0.34
Supply Return
(ft) (ft)
Measured length of run -out 20 0
Measured length of trunk 8 0
Equivalent length of fittings 105 0
Total length 133 0
Total effective length 133
Heating
Cooling
(in/100ft)
(in/100ft)
Supply Ducts -0.120 < 0.06
0.256 > 0.18
Return Ducts -0.120 < 0.06
0.256 >0.18
Supply 4X=35, 11A=20, 11G=5, 11G=5, 11G=5, 1A=35: TotalEL=105
Return TotalEL=O
AL wrigntsoft"
2020 -May -1914:14:49
- .11-1.1-11,,. �, _, „_., Right-Suite®Universal 2019 19.019 RSU16793 Page 1
ACCP. 2 B LHG Bed4 - E�Lot 12^1402 B LHG Bed4 - E rup Calc= MJ6 Front Door faces: E
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot 12 1402 B LHG Bed4 - E (COUNTY LOT 7) Builder Name: CENTURY COMPLETE
Street: 5801 Eastwood Dr Permit Office: ST LUCIE
City, State, Zip: Fort Pierce , FL , 34951 Permit Number:
Y
Owner: CENTURY COMPLETE Jurisdiction: 661000
U
w
Design Location: FL, ST_LUCIE_CO_INTL
T_
0
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spat
s
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind vil2ing and wiring-
irin .Shower/tub
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire, wrinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC -400.
5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
I DV VTR I
Job M Lot 121402 B LHG Bed4 - E One Stop Cooling and Heating Scale: 1 : 66
Performed by WW/SR for: Page 1
WADE JURNEY 7225 Sandsco\oe Court RigtitSuke®UnWrsa12019
19.0.19 RSU16793
5801 Eastwood Dr Winter Park, FL 32792 20204,Aay-19 14:15:52
Fort Pierce, FL 34951 Phone: (407) 629-6920 Fax (407) 629- 9307 ..E\Lot 12 1402 B LHG Bed4 -E.rup
wwwOneStopCooli ng.com
Level 1
MWIC
MBED
LIVING
8x4
10 cfm
10X10 2w
24 x4
10X10 2w
77 cfm
77 cfm
10x6 6
4 „
5
102 cfm
LRB 1
12 cfm 4
MBA
LAUN
F
034
EFL1 VTR
g
10"
593 cfm
I4T
BED 2 24x14 RA
BA 2
61c m
EF1 VTR
8x4
- 13 cfm
55 cfm
9 T
10x6
4
24 X4
6
6"
10x6
63 cfm
AKA 1.5 TON
1*7
EF1 = 50 CFM Fan
6 „
BED 3
14 0 SEER HP
EF2 = 80 CFM Fan
EF3 =110 CFM Fan
EFL1 = 50 CFM Fan
SRB 1
F OY
24 x 4
EFL2 = 80 CFM Fan
EFL3 =110 CFM Fan
VTR = Vent to Roof
GAR
VTW = Vent to Wall
I
DV = Dryer Vent
RV = Range Vent
24 x 4
10x6
— — = Lineset Chase
124 cfm
-Condensate
=Thermostat 18/8
SRB = Small Reduction Box
BED 4
LRB = Large Reduction Box
1
FEB = Field Built Box
I DV VTR I
Job M Lot 121402 B LHG Bed4 - E One Stop Cooling and Heating Scale: 1 : 66
Performed by WW/SR for: Page 1
WADE JURNEY 7225 Sandsco\oe Court RigtitSuke®UnWrsa12019
19.0.19 RSU16793
5801 Eastwood Dr Winter Park, FL 32792 20204,Aay-19 14:15:52
Fort Pierce, FL 34951 Phone: (407) 629-6920 Fax (407) 629- 9307 ..E\Lot 12 1402 B LHG Bed4 -E.rup
wwwOneStopCooli ng.com