Loading...
HomeMy WebLinkAboutcalcsFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 12 1402 B LHG Bed4 - E (COUNTY LOT 7) Builder Name: CENTURY COMPLETE Street: 5801 Eastwood Dr Permit Office: ST LUCIE City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: CENTURY COMPLETE Jurisdiction: 661000 Design Location FL, ST_LUCIE_CO_INTL County: St Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1408 0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 1108 00 ft' b. Frame - Wood, Adjacent R=13.0 300.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft' 5. Is this a worst case? No 10 Ceiling Types (1400.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1400.00 ft' 6. Conditioned floor area above grade (ft2) 1400 b N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7 Windows(122.8 sqft.) Description Area a Sup: Attic, Ret: Main, AH: Main 6 280 a. U -Factor: Dbl, U=0.35 122.78 ft2 SHGC: SHGC=0.29 b. U -Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a Central Unit 178 SEER:14.00 c. U -Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U -Factor: N/A ft2 a. Electric Heat Pump 17.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft Area Weighted Average SHGC: 0.290 14. Hot water systems a. Electric Cap: 50 gallonsEF: 8. Floor Types (1400.0 sqft.) Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1400.00 ft2 b. Conservation features 0.920 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.088 Total Proposed Modified Loads: 46.85 PASS PASS Total Baseline Loads: 47.21 1 hereby certify that the plans and specifications covered by Review of the plans and0 114E ST,q,1 this calculation are in compliance with the Florida Energy specifications covered by this ,y Code. M9ttauysignedbySTEVE STEVE ROGERS calculation indicates compliance ,. _ �+ '��*�„ ,! RflGEAS with the Florida Energy Code. � +rrr1R'�`'-�' � D Date: 2020.05 1914:36:01 -04'00'} PREPARED BY: - Before construction is completed +� � �- DATE- ... this building will be inspected for compliance with Section 553.908 Statutes. r� . I hereby certify that this buil ng, s de igned, is in compliance Florida with the Florida Energy Code. OWNER/AGENT BUILDING OFFICIAL: _ DATE: _. __._ - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. 5/19/2020 2:32 PM EnergyGauge® USA 6.0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 PROJECT Title: Lot 12 1402 B LHG Bed4 - E ( Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1400 Lot # 12 Owner Name: CENTURY COMPLETE Total Stories: 1 Block/Subdivision: LAKEWOOD PARK # of Units: 1 Worst Case: No PlatBook: Builder Name: CENTURY COMPLETE Rotate Angle: 270 Street: 5801 Eastwood Dr Permit Office: ST LUCIE Cross Ventilation: No County: St Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE { Design Temp Int Design Temp Heating Design Daily Temp �f Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1400 11200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1400 11200 Yes 5 4 1 Yes Yes Yes FLOORS Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 138.5 ft 1400 ft' _ 0.29 0 0.71 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1475 ft2 232 ft' Dark N 0.6 N 6 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1400 ft' N N CEILING # Ceiling Type Space R -Value Ins Type Area Framing Frac Truss Type W 1 Under Attic (Vented) Main 30 Blown 1400 ft2 0.1 Wood 5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 5/19/2020 2:32 PM EnergyGauge® USA 6.0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Crit_ To W�TypP Space R -VALE. Et in Et rn__ Area R -Value. Fraction .Absor-Grade%- 1 N=>W Exterior Frame - Wood Main 13 37 0 8 0 296.0 ft2 0 0.25 0.5 0 2 E=>N Exterior Frame - Wood Main 13 51 0 8 0 408 0 ft2 0 0.25 0.5 0 3 S=>E Exterior Frame - Wood Main 13 16 C 8 0 132.0 ft2 0 0.25 0.5 0 4 W=>S Exterior Frame - Wood Main 13 34 0 8 0 272.0 ft2 0 0.25 05 0 5 -SW Garage Frame - Wood Main 13 37 6 8 0 300.0 ft2 0 0.25 0.5 0 DOORS V # Ornt Door Type Space Storms U -Value Width Height Area Ft In Ft In 1 -SW Wood Main None .39 2 8 7 18.7 ft2 2 S=>E Insulated Main None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation (=>) changed to As Built rotated 270 degrees) / Wall Overhang V # Ornt ID Frame Panes NFRC U -Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low -E Double Yes 0.35 0.29 N 17.8 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 2 n=>W 1 Vinyl Low -E Double Yes 0.35 0.29 N 45.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 e=>N 2 Vinyl Low -E Double Yes 0,35 0.29 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 S=>E 3 Vinyl Low -E Double Yes 0.35 0.29 N 30 0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 W=>S 4 Vinyl Low -E Double Yes 0.35 0.29 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 408 ft2 408 ft2 48 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000356 1306.7 71 73 134.91 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 17.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 14 17.8 kBtu/hr 534 cfm 0.75 1 sys#1 5/19/2020 2:32 PM EnergyGauge® USA 6.0 02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R -Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 280 ft2 Main 70 ft2 Proposed Qn Main --- cfm 70.0 cfm 0.05 050 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinHJan [[ ]Feb [X� Feb jj jj Mar jXj Mar j j j Apr [ j Apr j ] May ] May X] Jun rl Jul 4 j Jun Jul Au jXj Au X] Se ] Sep Oct Oct Nov Nov Dec Dec Ventin Jan [[ ] Feb [[X]] Mar [X] A r [ j Ma [ ] Jun Jul Aug[ ] Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 g 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/s .ft. 0 ft2 0 ft 0.3 Main 5/19/2020 2:32 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5801 Eastwood Dr Permit Number: Fort Pierce , FL , 34951 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL ❑ R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveld-on building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. P—Y R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air L� changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air IeakagdNndows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open. combustion air ducts provide combustion air if) open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R -value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1 Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403 2 9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553 993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free' in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193 {1 R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manuf, air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturers air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 557 (13`C) shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe ❑ shall be a dedicated return pipe or a cold water supply pipe Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically tum off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. F-1 automatically Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Y: inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). ❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category Solar water heaters shall meet the criteria of Section R403.5 6.2.1 R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM -1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical EJ ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation El shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMUIV (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916 5/19/2020 2:33 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. El R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403 7 1 R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 El and C404 of the IECC—Commercial Provisions in lieu of Section R403. p -i R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). F]R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section Exceptions: 1. Where public health standards require 24-hour pump operation 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. ❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. ❑ R403.11 Portable spas (Mandatoryl�e energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ❑ R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1 New home or. addition 1. New From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3 No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 17.8 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq ft.) 6. 1400 d) Room unit/PTAC EER e) Other 7 Windows, type and area a) U-factor:(weighted average) 7a. 0.350 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.290 14. Heating system: Capacity 17.6 c) Area 7c. 122.8 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R -value) 9a. 0.0 b) Wood, raised (R -value) 9b. 15. Water heating system c) Concrete, raised (R -value) 9c a) Electric resistance EF 0.92 b) Gas fired, natural gas EF 10 Wall type and insulation: c) Gas fired, LPG EF A Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R -value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R -value) 10A2. 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R -value) 1061 13.0 2. Masonry (Insulation R -value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1 la. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has.eomplied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will b�completed a*d oraA stalled Mode compliant features. r' Builder Signature: Date- . f Address of New Home: 5801 Eastwood DF City/FL Zip: Fort Pierce. FL 34951 5/19/2020 2:33:01 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summa Job: Lot 12 1402 B LHG Bed4 - E ro, Summary wrightsoftm Date: 05/19/2020 House %r ww►sR One Stop Cooling and Heating Plan: LHG 7225 Sandscove Court, Winter Park. FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwm..OneStopCooling corn License: CAC032444 For: WADE JURNEY 5801 Eastwood Dr, Fort Pierce, FL 34951 Notes: Weather: Winter Design Conditions Outside db 41 °F Inside db 68 °F Design TD 27 °F Heating Summary Outside db Structure 14215 Btuh Ducts 1210 Btuh Central vent (0 cfm) 0 Btuh (none) 59 grAb n Humidification 0 Btuh Piping 0 Btuh Equipment load 15425 Btuh Infiltration St Lucie Cc Inti, FL, US Summer Design Conditions Outside db 90 °F Inside db 74 °F Design TD 16 of Daily range L Relative humidity 50 % Moisture difference 59 grAb Sensible Cooling Equipment Load Sizing Structure 11362 Btuh Ducts 2343 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Central vent (0 cfm) 0 Btuh RatelsWin multiplier Equipment sensible load 0.95 13074 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 3324 Btuh Heating output 17600 Btuh @ 47°F Ducts 523 Btuh 4450 Btuh Central vent (0 cfm) 0 Btuh Heating Coolie (none) Area (ftp) 1449 1449 Equipment latent load 3848 Btuh Volume (ft') 11594 11594 cfm Air changesfhour 0.68 0.30 Equipment Total Load (Sen+Lat) 16922 Btuh Equiv.AVf= (cfm) 132 58 Req. total capacity at 0.75 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier in H2O Make Carrier Trade CARRIER Load sensible heat ratio Trade CARRIER Model CH14NBO18000OA0 Capacity balance point = 37 °F Cond CH14NBO1800GOA0 AHRI ref 9162108 Coil FB4CNP018L AHRI ref 9162108 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 13350 Btuh Heating output 17600 Btuh @ 47°F Latent cooling 4450 Btuh Temperature rise 0 °F Total doling 17800 Btuh Actual air flow 0 cfm Actual air flow 593 cfm Airflowfactor 0 cknBtuh Airflowfactor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.78 Capacity balance point = 37 °F Backup: Input =13 kW, Output= 43537 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed 2020 -May -1914:14:46 ,tet M• Right -Suite® Universal 2019 19 0 19 RSU16793 Page 1 ACC - . 2 B LHG Bed4- EtLot 12 1402 B LHG Bed4 - E rup Calc= MJ8 Front Doorfaces: E wrightsoft, Right -J® Worksheet House One Stop Cooling and Heating Job: Lot 12 1402 B LHG Bed4 - E Date: 05/19/2020 WW/SR Pan: LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwvwOneStopCooling oom License: CAC032444 1 Room name House KIT 2 Exposed wall 138 5 it 115 ft 3 Room height 8.0 ft d 8.0 It heat/cool 4 Room dimensions 17.0 x 11.5 ft 5 Room area 1449 3 ft' 195 5 ft' Ty Construction U -value Or HTM Area (ft) Load Area (ft) Load number (BtuhAt'-°F) (B A2) or perimeter (ft) (B h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 V,V 12C -09w 0 091 n 2.46 230 408 393 966 905 92 92 226 212 G 4A5-2ov 0 350 n 9.45 10.08 15 0 142 151 0 0 0 0 W 12C -09w 0 091 a 2.46 230 132 82 201 189 0 0 0 0 4A5-2ov 0 350 a 9.45 2858 30 0 283 857 0 0 0 0 11 D 11D0 0.390 a 10.53 1182 20 20 212 238 0 0 0 0 IhV 12C -09w 0.091 s 246 2.30 272 257 631 592 0 0 0 0 t -G 4A5-2ov 0 350 s 9.45 1024 15 13 142 154 0 0 0 0 W 12C-Osw 0 091 w 246 2.30 296 233 573 537 0 0 0 0 G10D-v 0 350 w 9.45 2001 18 0 169 357 0 0 0 0 G 4A5-2ov 0 350 w 9.45 28,58 45 0 425 1286 0 0 0 0 12C -09w 0 091 - 246 1.40 300 281 691 394 0 0 0 0 D 11 D0 0.390 n 10.53 11.82 19 19 197 221 0 0 0 0 C 1613-30ad 0032 086 172 1449 1449 1252 2495 196 196 169 337 F 22A-tpm 1 180 3186 000 1449 139 4413 0 196 12 366 0 6 c)AED excursion 292 -93 Envelopeloss/gain 10296 8667 761 456 12 a) Infiltration 3919 1045 325 87 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 5 1150 0 0 Appliances/other 500 500 Subtotal (lines 6 to 13) 14215 11362 1087 1043 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 165 123 14 Subtdal 14215 11362 1252 1166 Dudloads 90/( 21% 1210 2343 9% 21% 107 240 r Total room load 15425 13704 1359 1407 Air required (dm) 0 593 0 61 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed A* 2020 -May -1914:14:48 -•--• Right-Suitee Unhwersa12019 19.0.'19 RSU16793 Page l AC0K ...2 B LHG Bad4 - Elot 121402 B LHG Bed4 - E.rup Calc= MJB Frant Doorfarxs: E wrightsoft° Right -M Worksheet House One Stop Cooling and Heating Job: Lot 12 1402 B LHG Bed4 - E Date: 05/19/2020 WW/SR Pan: LHG 7225 Sandsowe Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444 1 Room name FOY MBA 2 Exposed wall 50 ft 55 it 3 Room height 8.0 ft heaV000l 80 ft heat/000l 4 Room dimensions 10 x 150.3 ft 110 x 55 ft 5 Room area 150 3 ft' 60 5 fF Ty Construction U -value Or HTM Area (ft') Load Area (ft') Load number (Btuhd`--°F) (BV) or perimeter (ft) (Bh) or perimeter (ft) (Btah) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 %t12C-0sw 0 091 n 246 2 30 0 0 0 0 0 0 0 0 t G 4A5-2ov 0 350 n 945 10.08 0 0 0 0 00 0 0 IW 12C-Osw 0 091 e 246 230 40 20 49 46' .0 (1 0 0 4A5-2ov 0.350 a 945 28.58 0 0' 0 0 0 (1 0 0 11 D 11DO 0.390 a 10.53 11.82 20 20 212 238 0 0 0 0 T—G 12C-Ow0 091 s 246 230 0 0 0 0 44!44 108 101 4A5-2ov 0 350 s 945 10.24 0 0 0 0 0 0' 0 0 IW 12C-Osw 0 091 w246 2.30 0 0 0 0 0 0 0 0 EI— 11 OD -v 0 350 w 945 2001 0 0 0 0 0 0 0 0 G 4A5-2ov 0 350 w 9.45 28.58 0 0 0 0 0 0 0 0 q—D 12C-Osw 0.091 - 246 1.40 216 197 485 277 0 0 0 0 11 DO 0 390 n 10.53 1182 19 19 197 221 0 0 0 0 C 1613-30ad 0 032 086 172 150 150 130 259 51 61 52 104 F 22A-tpm 1180 3186 0.00 150 5 159 0 61 6 175 0 6 c)AED excursion -88 -20 Envelope losslgain 1231 951 336 185 12 a) Infiltraton 141 38 156 41 b) Room ventlaton 10 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines6 to 13) 1373 989 491 227 Less ex:L-mal load 0 0 0 0 Lesstransfer 0 01 0 0 Redistributon -1373 -989 6 11 14 Subtotal 001 497 238 15 Ductloads 9% 21% 0 0 9% 21% 42 49 Total room load 0 0 540 287 Air required (cfm) 0 0 0 12 Calculations aDDroved NACCA to meet all reauirements of Manual J 8th Ed -jr-gt,sof# 2020 -May -1914:14:48 .�- - — Right-Su+tP.=. Universal 2019 19.0.19 RSU16793 Page 2 '��` ...2 B LHG Bed4 - E%Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Door faces: E wrightsoft- Right -JO Worksheet House One Stop Cooling and Heating Job: Lot 12 1402 B LHG Bed4 - E Date: 05/19/2020 WW/SR Pan: LHG 7225 Sandscove Court, Wnter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vw .OneStopCooling com License: CAC032444 1 Room name IMBED LAUN 2 6posed wall 270 ft O ft 3 Room height 80 ft heat/ood 80 It heaUcUol 4 Room dimensions 140 x 130 ft 60 x 4.0 ft 5 Room area 182 0 ft' 24 0 fF Ty Construction U -value Or HTM Area (ft') Load Area (W) Load number (BbjW-°F) (B AF) or perimeter (ft) (B h) or perimeter (ft) (13tuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 12C-Osv 0091 n 2-46 230 0 0 0 0 0 O 0 0 4A5-2ov 0 350 n 945 1008 0 0 0 0 0 0 0 0 IW 12C-0sw 0 091 a 246 230 0 0 0 0 0 0 0 0 4A5-2ov 0.350 a 9.45 28.58 0 0 0 0 0 0 0 0 11 D 11 DO 0.390 a 10.53 11.82 0 0 0 0 0 0 0 0 T1 12C -09w 0.091 s 2.46 230 104 104 256 239 0 0 0 0 --C 4A5 2ov 0.350 s 9 45 1024 0 0 0 0 0 0 0 W 12C-0 sw 0 091 w 246 230 112 97 238 223 0 0 0 0 E0 OD -v 0 350 w 9.45 2001 0 0 0 0 0 0 0 O 4A5-2ov 0.350 w 9.45 28.58 15 0 142 429 0 0 0 0 q—D 12C-Osw 0-091 - 246 1.40 0 0 0 0 0 0 0 0.82 11 DO 0.390 n 1053 11 0 0 0 0 0 0 0 0 C 1613-30ad 0 032 086 172 182 182 157 313 24 24 21 41 F 22A-tpm 1.180 31.86 0.00 182 27 860 0 24 0 0 0 6 c)AED excursion 77 -3 Envelopeloss/gain 1653 1282 21 38 12 a) Inriltraton 764 204 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2417 1946 21 38 Lessextemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 3 6 -21 -38 14 Subtotal 2420 1952 0 0 15 Dudloads 9% 21%1 206 402 9% 21% 0 0 Total room load 2626 2354 1 0 0 Air required (cfm) 0 102 0 0 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed �* w. igFtitsol# 2020 -May -1914:14:48 Right -Suite -%Universal 2019199.19 RSU16793 Page 3 '40C:;P` ...2 6 LHG Bed4 - E+Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Doorfaces: E wrightsoft' Right -JO Worksheet House One Stop Cooling and Heating Job: Lot 12 1402 B LHG Bed4 - E Date: 05/19/2020 Bgyy• WW/SR Pfan: LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vwwvOneStopCooling.eom License: CAC032444 1 Room name BA2 2 Exposed wall O ft O ft 3 Room height 80 ft heat/000l 80 ft heaU000l 4 Room dimensions 6.0 x 8.5 ft 35 x 35 ft 5 Room area 51.0 ft' 12.3 ft= Ty Construction U -value Or HTM Area (ft2) Load Area (ft°) Load number (BtuhA2--°F) (B /F) or perimeter (ft) (B h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 tq✓ 12C-0swv 0 091 n 2.46 230 0 0 0 0 0 0 0 0 �G 4A5-2ov 0 350 n 9.45 1008 0 0 0 0 0 0 0 0 W 12C-Osw 0 091 a 246 2.30 0 0 0 (1 0 0 0 0 F—G 4A5-2ov 0.350 e 945 28.58 0 0 0 0 0 0 0 0 11 D 11 DO 0 390 a 1053 1182 0 0 0 (1 0 0 0 0 V�J 12C -09N0 091 s 2.46 230 0 0 0 0 0 0 0 0 t—G 4A5-2ov 0.350 s 9.45 10.24 0 0 0 0 0 0 0 0 W 12C-Osw 0091 w 246 230 0 0 0 0 0 0 0 0 E1OD-v 0350 w 945 20.01 0 0 0 0 0 O 0 0 4A5-2ov 0 350 w 945 2858 0 0 0 0 0 0 0 0 I—D 12C-Osw 0.091 - 246 1.40 0 0 0 0 0 0 0 0 1 1D 0.390 n 10.53' 11.82 0 0 0 0 0 0 0 0 C 166-30ad 0.032 0.86 1.72 51 51 44 88 12 12 11 21 F 221-tpm 1.180, 31.86 0.00 51 0 0 0 12 0 0 0 6 c)AED excursion -7 -2 Envelopeloss/gain 44 81 11 19 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines6to 13) 44 81 11 19 Less external load 0 0 0 0 LesstransW 0 0 0 0 Redistribution 206 161 -11 -19 14 Subtotal 250 242 0 0 15 Ductloads 9°/< 21% 21 50 9% 21% 0, 0 Total room load 271 292 0 0 Air required (dm) 0 13 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �}� wrightsaTt 2020 -May -1914:14:48 AC.-(ffA Right -Suite® Universal 2019 19.0 19 RSU16793 Page 4 .2 B LHG Bed4 - EtLot 121402 B LHG Bed4 - E.rup Calc= MJ8 Front Door faces: E wrightsoft° Right -JO Worksheet House One Stop Cooling and Heating Job: Lot 12 1402 B LHG Bed4 - E Date: 05/19/2020 WW/SR Pan: LHG 7225 Sandsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444 1 Room name BED 2 BED 3 2 Exposed wall 120 ft 105 ft 3 Room height 80 ft heaV000l 8.0 ft heatbod 4 Roomdimensons TO x 1418 ft 10 x 1418 ft 5 Room area 1418 ft' 1418 tt2 Ty Construction U -value Or HTM Area (ft') Load Area (1F) Load number (BtuhAt'--°F) (B AF) or perimeter (ft) (B h) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 µ1l 12C -09N 0 091 n 2.46 230 0 0 0 0 84 69 170 ' 159 l_ 4A5-2ov 0.350 n 9.45 10.08 0 0 0 0 15 0 142 151 IW 12C-Osw 0 091 a 246 230 0 0 0 0 0 0 0 0 4A5-2ov 0.350 e 945 2858 0 0 0 0 C 0 0 0 11 D 11 DO 0 390 a 1053 1182 0 0 0 0 0 0 0 0 µV 12C-Osw 0 091 s 246 2.30 96 81 199 186 0 0 0 0 L—G 4A5-2ov 0.350 s 945 1024 15 13 142 154 0 0 0, 0 W 12C -09m 0.091 w 246 230 0 0 0 0 0 0 0 0 1OD-v 0.350 w 9.45 2001. 0 0 0 0 0 0 0 0 G 4A5-2ov 0.350 w 945 28.58 0 0 0 0 0 0 0 0 12C-Osw 0 091 - 2.46 1.40 84 84 206 118 0 0 0 0 D 11 DO 0 390 n 10.53 11.82 0 0 0 0 0 0 0 0 C 16B-30ad 0 032 086 1.72 142 142 122 244 142 142 122 244 F 22A-tpm 1.180 3186 0.00 142 12 382 0' 142 11 335 0 6 c)AED e=rsion -72 -70 Envelopeloss/gain 1052 630 768 484 12 a) Infiltration 340 91 297 79 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants@ 230 1 23C 1 230 Appliancesbther 0 0 Subtotal (lines 6 to 13) 1391 95C 1065 793 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 140 112 565 407 14 Subhotal 1531 1062 1631 1200 15 Dudloads 9% 21% 130 219 9% 21% 139 247 Total room load 1661 1281 1769 1448 Airrequired (cfm) 0 55 0 63 Calculations aDDroved NACCA to meet all reauirements of Manual J 8th Ed -jr-wrightsoit 2020 -May -1914:14:48 — - Right-SurteE Universal 2019 19.0, 19 RSU16793 Page 5 'CC;P` ...2 B LHG Bed4 - E1Let 12 1402 B LHG 3ed4 . E.rup Calc = MJ8 Front Door faces: E wrightsoft' Right -JO Worksheet Job: House °Bay�te` One Stop Cooling and Heating Plan: 7225 Sandscove Court, VYnter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444 Lot 12 1402 B LHG Bed4 - E 05/19/2020 WW/SR LHG 1 Room name MVVIC BED 4 2 Exposed wall 50 ft 290 ft 3 Room height 80 ft heaU000l 80 ft heaU000l 4 Room dimensions 50 x 90 ft 10 x 134 8 ft 5 Room area 45.0 fl? 134 8 ft' Ty Constructon U -value Or HTM Area (ft') Load Area (ft') Load number (BtuhrR'-°F) (B /W) or perimeter (ft) (B h) or perimeter (ft) (Btuh) Heat Cod Gross NIPS Heat Cod Gross N/P/S Heat Cod 6 \f12C-Osw 0.091 n 2,46 230 0 0 0 0 112 112 275 258. C, 4A5-2ov 0.350 n 9.45 10.08 0 0 0 0 0 0 0 0 W 12C -09w 0 091 a 246 2.30 0 0 0 0 92 62 152 143 4A5-2ov 0 350 e 945 2858 0 0 01 0 30 0 283 857 11 D 11 DO 0 390 a 1053 1182 0 0 0' 0 0 0 0 0 L�V 12C-Ow0 091 s 246 2 30 0 0 0 0 28 28 69 64 L—G 4A5-2ov 0 350 s 9.45 10 24 0 0 0 0 0 0 0 0 W 12C-Ow0.091 w 246 2.30 40 40 98 92 0 0 0 0 1 OD -v 0 350 w 9.45' 20.01 0 0 0 0 0 0 0 0 4A5-2ov 0 350 w 9 45 28,58 0 0 0 0 0 0 0 0 L—D 12C -0s 0 091 - 2.46 1.40 0 0 0 0 0 0 0 0 11 DO 0.390 n 1053 11.82 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 086 1.72 45 45 39 77 135 135 116 232 F 22A-tpm 1.180 - 3186 0.00 45 5 159 0 135 29 924 0 6 c)AED excursion -17 139 Envelope lossrgain 296 153 1820 1694 12 a) Infiltration 141 38 821 219 b) Room ventilation 0 0 10 0 13 Internal gains: Occupants@ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 438 190 2641 2143 Less exlemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 323 233 14 Subtotal 438 190 2964 2375 15 Dudloads 9% 21% 37 39 9% 21% 252 490 Total room load 478 230 3216 2865 Air required (dm) 0 10 0 124 Calculations awroved bvACCA to meet all requirements of Manual J 8th Ed -Pk- wrigl #soft 2020 -May -1914:14:48 - --- Right-Sult-16' Universal 2019 19.0.1 O RSU16793 Page 6 lift ...2 B LHG Bed4 - E1Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Door tabes: E +- wrightsoft, Right -JO Worksheet House One Stop Cooling and Heating Job: Lot 12 1402 B LHG Bed4 - E Date: 05/1912020 WW/SR Pan: LHG 7225 Sandsmve Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling com License: CAC032444 1 Room name LIVING WH 2 Exposed wall 330 ft O ft 3 Room height 80 ft heaU000l 80 ft heat/ood 4 Room dimensions 10 x 294 O ft 30 x 55 It 5 Room area 294.0 T 16.5 IF Ty Construction U -value Or HTM Area (ft') Load Area (ftp Load number (BtuhAF--°F) (B AF) or perimeter (ft) (B h) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat I Cool 6 kt12C-Osw 0 091 n 2.46 230 120 120 295 276 0 0 0 0 �G 4A5-2ov 0.350 n 945 1008 0 0 0 0 0 0 0 0 IW 12C-Osw 0 091 a 246 2.30 0 0 0 0 0 0 0 0 I—G 4A--,2.,, 0.350 a 9.45 2858 0 0 C 0 0 0 0 0 11 1D 11 DO 0 390 a 1053 11.82 0 0 C 0 0 0 0 0 12C-Osw 0 091 s 246 2.30 0 0 C 0 0 0 0 0 4A5-2ov 0 350 s 945 10.24 0 0 0 0 0 0 0 0 IW 12C-Osw 0 091 w 246 230 144 96 236 221 0 0 0 0 l OD -v 0.350 w 945 2001 18 0 169 357 0 0 0 0 I G 4A5-2ov 0 350 w 945 2858 30 0 283 857 0 0 O 0 12C-0sw 0.091 - 246 1.40 0 0 0 0 0 0 0 0 D 11 DO 0.390 n 1053 1182 0 0 0 0 0 0 0 0 C 166-30ad 0 032 0.86 1.72 294 294 254 506 17 17 14 28 F 22A-tpm 1.180 3186 000 294 33 1051 0 17 0 0 0 6 c)AED excursion 450 -2 Envelopeloss/gain 2289 2668 14 26 12 a) Infiltration 934 249 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoeslother 0 0 Subtotal (lines61o13) 3223 2917 14 26 Less external load 0 0 0 0 Less transfer 0 C 0 0 Redistribution 10 19 -14 -26 14 Subtotal 3233 2936 0 0 15 Dudloads 9% 21%1 275 605 9% 1 21% 0 0 Total room load 3508 3541 1 0 0 Air required (chm) 0 1531 0 0 Calculations woroved bvACCA to meet all requirements of Manual J 8th Ed -r�F 2020 -May -19 14:14:48 - Right-Suite®Universal2019190 19RSU16793 Page 'CC�K ..2 B LHG Bed4 - E\Lot 12 1402 B LHG Bed4 - E.rup Calc= MJ8 Front Doorfaces: E Duct System Summary Job: Lot 12 1402 B LHG Bed4 - E wrightsoft, Date: 05119/2020 House By: WW/SR One Stop Cooling and Heating Plan: LHG 7225 Sandscove Court, winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: ew w..OneStopCooling corn License: CAG032444 For: WADE JURNEY 5801 Eastwood Dr, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0.16 in H2O -0.2 in H2O -0.080/-0.080 in H2O -0.12 in/100ft 0 cfin 133 ft Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.170 /0.170 in H2O 0.256 in/100ft 593 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W I (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 c 292 0 13 0.303 4.0 Oxo VIFx 17.3 95.0 st1 BED2 c 1281 0 55 0.294 6.0 0x0 VIFx 20.6 95.0 st1 BED3 c 1448 0 63 0.301 6.0 0x0 VIFx 18.1 95.0 st1 BED4 c 2865 0 124 0.256 6.0 0x0 VIFx 27.9 105.0 st1 KIT c 1407 0 61 0.291 6.0 Ox 0 VIFx 22.0 95.0 st2 LIVING c 1771 0 77 0.292 5.0 Ox 0 VIFx 21.3 95.0 st2 LIVING -A c 1771 0 77 0.275 5.0 Ox 0 VIFx 28.5 95.0 st2 MBA c 287 0 12 0.290 4.0 Ox 0 VIFx 22.4 95.0 st2 IMBED c 2354 0 102 0.286 6.0 Ox 0 VIFx 24.0 95.0 st2 MWIC c 230 0 10 0.298 4.0 Ox 0 VIFx 19.2 95.0 st2 wrightsoft- 2020 -May -1914:14:49 ^, „_, _ , Right -Suite® Universal 201919.019 RSU16793 Page 1 ACO, ...2 B LHG Bed4 - EtLot 121402 B LHG Bed4 - E rup Calc= 1VJ8 Front Doerfaees: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (dm) (dim) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 255 0.256 577 9.0 0 x 0 VinlFlx st2 PeakAVF 0 339 0.275 621 10.0 0 x 0 VinlFlx wrightsoft- 2020 -May -1914:14:49 ^, „_, _ , Right -Suite® Universal 201919.019 RSU16793 Page 1 ACO, ...2 B LHG Bed4 - EtLot 121402 B LHG Bed4 - E rup Calc= 1VJ8 Front Doerfaees: E Name Grille Size (in) Htg (cfm) Clg (dm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mab Trunk rb1 0x0 0 593 0 0 0 0 Ox 0 VIFx wrightsoft- 2020 -May -1914:14:49 A -L .,,., �,._ Right -Suite® Universal 2019 19.0 19 RSU16793 Paget zr. 2 8 LHG Bed4 - E\Lot 121402 B LHG Bed4 - E.rup Calc= MJ8 Front Door faces: E Static Pressure and Friction Rate Job: Lot 121402 B LHG Bed4 -E wrightsoftm Date: 05/19/2020 House E,: WW/SR One Stop Cooling and Heating Plan: LHG 7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: vawOneStopCooling com License: CAC032444 For: WADE JURNEY 5801 Eastwood Dr, Fort Pierce, FL 34951 Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0 0.50 Pressure losses Coil 0 0 Heatexchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 010 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure -0.2 0.34 Supply Return (ft) (ft) Measured length of run -out 20 0 Measured length of trunk 8 0 Equivalent length of fittings 105 0 Total length 133 0 Total effective length 133 Heating Cooling (in/100ft) (in/100ft) Supply Ducts -0.120 < 0.06 0.256 > 0.18 Return Ducts -0.120 < 0.06 0.256 >0.18 Supply 4X=35, 11A=20, 11G=5, 11G=5, 11G=5, 1A=35: TotalEL=105 Return TotalEL=O AL wrigntsoft" 2020 -May -1914:14:49 - .11-1.1-11,,. �, _, „_., Right-Suite®Universal 2019 19.019 RSU16793 Page 1 ACCP. 2 B LHG Bed4 - E�Lot 12^1402 B LHG Bed4 - E rup Calc= MJ6 Front Door faces: E 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Lot 12 1402 B LHG Bed4 - E (COUNTY LOT 7) Builder Name: CENTURY COMPLETE Street: 5801 Eastwood Dr Permit Office: ST LUCIE City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Y Owner: CENTURY COMPLETE Jurisdiction: 661000 U w Design Location: FL, ST_LUCIE_CO_INTL T_ 0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spat s Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind vil2ing and wiring- irin .Shower/tub Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire, wrinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC -400. 5/19/2020 2:33 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 I DV VTR I Job M Lot 121402 B LHG Bed4 - E One Stop Cooling and Heating Scale: 1 : 66 Performed by WW/SR for: Page 1 WADE JURNEY 7225 Sandsco\oe Court RigtitSuke®UnWrsa12019 19.0.19 RSU16793 5801 Eastwood Dr Winter Park, FL 32792 20204,Aay-19 14:15:52 Fort Pierce, FL 34951 Phone: (407) 629-6920 Fax (407) 629- 9307 ..E\Lot 12 1402 B LHG Bed4 -E.rup wwwOneStopCooli ng.com Level 1 MWIC MBED LIVING 8x4 10 cfm 10X10 2w 24 x4 10X10 2w 77 cfm 77 cfm 10x6 6 4 „ 5 102 cfm LRB 1 12 cfm 4 MBA LAUN F 034 EFL1 VTR g 10" 593 cfm I4T BED 2 24x14 RA BA 2 61c m EF1 VTR 8x4 - 13 cfm 55 cfm 9 T 10x6 4 24 X4 6 6" 10x6 63 cfm AKA 1.5 TON 1*7 EF1 = 50 CFM Fan 6 „ BED 3 14 0 SEER HP EF2 = 80 CFM Fan EF3 =110 CFM Fan EFL1 = 50 CFM Fan SRB 1 F OY 24 x 4 EFL2 = 80 CFM Fan EFL3 =110 CFM Fan VTR = Vent to Roof GAR VTW = Vent to Wall I DV = Dryer Vent RV = Range Vent 24 x 4 10x6 — — = Lineset Chase 124 cfm -Condensate =Thermostat 18/8 SRB = Small Reduction Box BED 4 LRB = Large Reduction Box 1 FEB = Field Built Box I DV VTR I Job M Lot 121402 B LHG Bed4 - E One Stop Cooling and Heating Scale: 1 : 66 Performed by WW/SR for: Page 1 WADE JURNEY 7225 Sandsco\oe Court RigtitSuke®UnWrsa12019 19.0.19 RSU16793 5801 Eastwood Dr Winter Park, FL 32792 20204,Aay-19 14:15:52 Fort Pierce, FL 34951 Phone: (407) 629-6920 Fax (407) 629- 9307 ..E\Lot 12 1402 B LHG Bed4 -E.rup wwwOneStopCooli ng.com