Loading...
HomeMy WebLinkAboutEnergy CodeEm FORM R405-2017 ( FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 20 Block 2 Walerstone 2265 AGR Builder Name: ADAMS HOMES Street: 8220 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number. Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1984.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1368.30 ft2 3. Number of units, if multiple family 1 b. Frame -Wood, Exterior c. Frame - Wood, Adjacent R=13.0 407.83 ft2 4. Number of Bedrooms 4 d. N/A R=13.0 208.00 ft2 R= ft2 5. Is This a worst nse? No 10. Ceiling Types (2277.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2277.00 11:2 6. Conditioned floor area above grade (ft2) 2277 b. WA R= ft2 Conditioned Floor area below grade (ft2) 0 °. NIA R= ft2 7. Windows(306.4 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 456.2 a. U-Factor: Dbl, U=0.33 166.06 ft2 SHGC: SHGC=0.23 b. U-Factor. Dbl, U=0.33 70.92 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.55 51.11112 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 18.33 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 5.808 ft. Area Weighted Average SHGC: 0.309 14. Hot water systems 8. Floor Types (2277.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2 b. Conservation features EF: 0.940 b. WA R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.135 Total Proposed Modified Loads: 69.09 PASS Total Baseline Loads: 72.24 I hereby certify that the plans and specifications covered by Review of the plans and S74T� this calculation are in comp lia �i the Florida �"'-1� specifications covered by this 0�'C}1E Code. calculation indicates compliance a`t' ii„ •='s`c° r, with the Florida Energy Code. nn,�Z^;; PREPARED BY: Before construction is completed c� DATE: 2-24_7070 Wnn KPnmar+v this building will be inspected for compliance with Section 553.908 x I hereby certify that this building, as designed, is in compliance Florida Statutes. k with the Floridak=gy-G2d C� COD Wf. OWNER/AGE�I lT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/24/2020 12:08 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 20 Block 2 Waterstone 22 Bedrooms: 4 User Conditioned Area: 2277 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 20 Block/Subdivision: Waterstone PlatBook: Street: 8220 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockt 2277 20493 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2277 20493 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2277 ft' _--- 0.36 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2547 1112 570 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Aftic(Vented) Main 30 Blown 2277 ft2 0.11 Wood 2/24/2020 12:08 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 � rvrtm n WALLS Adjacent Spam Pgnr Cavity Width Height Sheathing Framing Solar Below Grnrlp% 1 SE Exterior Frame - Wood Main 13 10 2 8 0 81.3 ft2 0 0.23 0.6 0 2 SE Exterior Concrete Block - Int Insul Main 4.1 38 7 10 0 385.8 ft2 0 0 0.6 0 3 SW Exterior Frame - Wood Main 13 4 6 10 0 46.0 ft2 0 0.23 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 27 6 10 0 275.0 ft2 0 0 0.6 0 _5 NW Exterior Frame - Wood Main 13 6 9 8 0 54.0 ft2 0 0.23 0.6 0 6 NW Exterior Concrete Block -Int Insul Main 4.1 50 3 8 0 402.0 ft2 0 0 0.6 0 7 N Exterior Frame - Wood Main 13 3 10 10 0 38.3 ft2 0 0.23 0.6 0 _ 8 N Exterior Concrete Block - Int Insul Main 4.1 0 5 10 0 4.2 ft2 0 0 0.6 0 _ 9 NE Exterior Frame - Wood Main 13 18 11 10 0 189.2 ft2 0 0.23 0.6 0 _10 NE Exterior Concrete Block -Int Insul Main 4.1 37 8 8 0 301.3 112 0 0 0.6 0 11 - Garage Frame - Wood Main 13 26 0 8 0 208.0 ft2 0 0.23 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separalic 1 SE 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in 2 SE 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 0 ft 10 in 3 SW 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 7 ft 8 in 0 ft 6 in 4 SW 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 7 it 8 in 2 ft 10 in 5 SW 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 0 ft 10 In 6 SW 4 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 0 in 2 ft 10 in 7 NW 5 Vinyl Low-E Double Yes 0.55 0.7 N 15.6 ft2 23 ft 0 in 0 ft 9 in 8 NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 0 in 0 ft 10 in 9 NW 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in 10 N 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 112 11 ft 0 in 0 ft 4In 11 NE 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in 12 NE 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 6 ft 8 in 0 ft 4 in 13 NE 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4In 14 NE 10 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 112 1 ft 0 in 1 ft 2 in Int Shade Screeninc Drapes/blinds None Drapes/blinds Exterior None None None None Drapes/blinds Exterior Drapes/blinds Exterior Drapes/blinds None Drapes/blinds Exterior Drapes/blinds Exterior Drapes/blinds Exterior Drapes/blinds None Drapes/blinds Exterior Drapes/blinds Extedor5 Drapes/blinds Exterior 2/24/2020 12:08 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 617 ft' 617 ft- 64ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2390.9 131.25 246.84 .1454 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1167 cm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS # Ev —Supply--- Location R-Value Area --Retum— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 2/24/2020 12:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostatt(:')Y Crralling Fans:Cooling g Jan Feb (r�, Apr May Jun Jun Jul(rXrr � Jul Aug rl lrX i Ir)(') VentinHJan [ ] [X] Mar [ [ Aug [ Sep Oct X[ ] NoNovv Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 81bs/s .ft. 0 ft- 0 ft 0.3 Main 2/24/2020 12:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2277 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.367 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.309 14. Heating system: Capacity 34.6 c) Area 7c. 306.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c, d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 8220 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951 2/24/2020 12:08:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1