HomeMy WebLinkAboutEnergy CodeEm
FORM R405-2017
( FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 20 Block 2 Walerstone 2265 AGR
Builder Name: ADAMS HOMES
Street: 8220 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number.
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1984.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1368.30 ft2
3. Number of units, if multiple family 1
b. Frame -Wood, Exterior
c. Frame - Wood, Adjacent
R=13.0 407.83 ft2
4. Number of Bedrooms 4
d. N/A
R=13.0 208.00 ft2
R= ft2
5. Is This a worst nse? No
10. Ceiling Types (2277.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2277.00 11:2
6. Conditioned floor area above grade (ft2) 2277
b. WA
R= ft2
Conditioned Floor area below grade (ft2) 0
°. NIA
R= ft2
7. Windows(306.4 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 456.2
a. U-Factor: Dbl, U=0.33 166.06 ft2
SHGC: SHGC=0.23
b. U-Factor. Dbl, U=0.33 70.92 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.50
c. U-Factor: Dbl, U=0.55 51.11112
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 18.33 ft2
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 5.808 ft.
Area Weighted Average SHGC: 0.309
14. Hot water systems
8. Floor Types (2277.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2
b. Conservation features
EF: 0.940
b. WA R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.135 Total Proposed Modified Loads: 69.09
PASS
Total Baseline
Loads: 72.24
I hereby certify that the plans and specifications covered by
Review of the plans and
S74T�
this calculation are in comp lia �i the Florida �"'-1�
specifications covered by this
0�'C}1E
Code.
calculation indicates compliance
a`t' ii„ •='s`c° r,
with the Florida Energy Code.
nn,�Z^;;
PREPARED BY:
Before construction is completed
c�
DATE: 2-24_7070 Wnn KPnmar+v
this building will be inspected for
compliance with Section 553.908
x
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
k
with the Floridak=gy-G2d
C�
COD Wf.
OWNER/AGE�I lT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
2/24/2020 12:08 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 20 Block 2 Waterstone 22 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 20
Block/Subdivision: Waterstone
PlatBook:
Street: 8220 Amalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
_ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockt
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ft' _--- 0.36 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2547 1112 570 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Aftic(Vented)
Main 30 Blown
2277 ft2 0.11 Wood
2/24/2020 12:08 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
� rvrtm
n
WALLS
Adjacent
Spam
Pgnr
Cavity
Width
Height
Sheathing Framing
Solar Below
Grnrlp%
1
SE
Exterior
Frame - Wood
Main
13
10
2
8
0
81.3 ft2
0
0.23
0.6
0
2
SE
Exterior
Concrete Block - Int Insul
Main
4.1
38
7
10
0
385.8 ft2
0
0
0.6
0
3
SW
Exterior
Frame - Wood
Main
13
4
6
10
0
46.0 ft2
0
0.23
0.6
0
4
SW
Exterior
Concrete Block - Int Insul
Main
4.1
27
6
10
0
275.0 ft2
0
0
0.6
0
_5
NW
Exterior
Frame - Wood
Main
13
6
9
8
0
54.0 ft2
0
0.23
0.6
0
6
NW
Exterior
Concrete Block -Int Insul
Main
4.1
50
3
8
0
402.0 ft2
0
0
0.6
0
7
N
Exterior
Frame - Wood
Main
13
3
10
10
0
38.3 ft2
0
0.23
0.6
0
_ 8
N
Exterior
Concrete Block - Int Insul
Main
4.1
0
5
10
0
4.2 ft2
0
0
0.6
0
_ 9
NE
Exterior
Frame - Wood
Main
13
18
11
10
0
189.2 ft2
0
0.23
0.6
0
_10
NE
Exterior
Concrete Block -Int Insul
Main
4.1
37
8
8
0
301.3 112
0
0
0.6
0
11
-
Garage
Frame - Wood
Main
13
26
0
8
0
208.0 ft2
0
0.23
0.01
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V #
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separalic
1
SE
1
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
23 ft 0 in
0 ft 9 in
2
SE
2
Vinyl
Low-E Double
Yes
0.33
0.23
N
32.4 ft2
1 ft 0 in
0 ft 10 in
3
SW
3
Vinyl
Low-E Double
Yes
0.33
0.31
N
5.0 ft2
7 ft 8 in
0 ft 6 in
4
SW
4
Vinyl
Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 it 8 in
2 ft 10 in
5
SW
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
32.4 ft2
1 ft 0 in
0 ft 10 In
6
SW
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
38.5 ft2
1 ft 0 in
2 ft 10 in
7
NW
5
Vinyl
Low-E Double
Yes
0.55
0.7
N
15.6 ft2
23 ft 0 in
0 ft 9 in
8
NW
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 0 in
0 ft 10 in
9
NW
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 0 in
0 ft 10 in
10
N
7
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 112
11 ft 0 in
0 ft 4In
11
NE
9
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 4 in
0 ft 9 in
12
NE
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
16.7 ft2
6 ft 8 in
0 ft 4 in
13
NE
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 4 in
0 ft 4In
14
NE
10
Vinyl
Low-E Double
Yes
0.33
0.23
N
48.6 112
1 ft 0 in
1 ft 2 in
Int Shade Screeninc
Drapes/blinds None
Drapes/blinds Exterior
None None
None None
Drapes/blinds Exterior
Drapes/blinds Exterior
Drapes/blinds None
Drapes/blinds Exterior
Drapes/blinds Exterior
Drapes/blinds Exterior
Drapes/blinds None
Drapes/blinds Exterior
Drapes/blinds Extedor5
Drapes/blinds Exterior
2/24/2020 12:08 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617 ft'
617 ft-
64ft 8ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.25 246.84 .1454 7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER: 15.5 35 kBtu/hr 1167 cm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft'
DUCTS
#
Ev
—Supply---
Location R-Value Area
--Retum— Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC#
Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
2/24/2020 12:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostatt(:')Y
Crralling Fans:Cooling
g Jan
Feb
(r�,
Apr
May
Jun
Jun
Jul(rXrr
� Jul
Aug
rl
lrX
i
Ir)(')
VentinHJan
[ ]
[X] Mar
[
[
Aug
[
Sep
Oct
X[ ] NoNovv
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling(WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 81bs/s
.ft.
0 ft-
0 ft
0.3
Main
2/24/2020 12:08 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
35.0
a) Split system SEER
15.5
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2277
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.367
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.309
14. Heating system: Capacity
34.6
c) Area
7c.
306.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
13.0
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081.
13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c,
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 8220 Amalfi Circle City/FL Zip: Fort Pierce, FL 34951
2/24/2020 12:08:31 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1