HomeMy WebLinkAboutHOYT PLANSSTEP DETAIL 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT AREA WHERE DECK RAISED +6" ABOVE POOL N.T.S. 10" MIN. STEP DETAIL #8 GROUND WIRE HANDRAIL BONDING DETAIL WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE48" MAX WATER DEPTH 12" MAX. VAC LINE 6' DEEP GENERAL NOTES: 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. JOB NAME: HOYT ADDRESS: 3426 SOUTHERN PINES DR PERMIT NO.: DATE DRAWN: APRIL 27, 2020 DRAWN BY: TRAVIS LEONARD DESIGNER APPROVAL: CUSTOMER APPROVAL: SCALE: 1/4" = 1' MAX. WIDTH MIN. DEPTH 14' SHAPE FILL FROM EXCAVATION TILE FILTER PUMP HP: TIMER LIGHTS TRNFORM: MAIN DRAIN: SKIMMER RETURNS: VALVED VAC LINE DISCHARGE LINE CHLORINATOR HANDRAIL DIVING BOARD HEATER VACUUM HEAD VACUUM HOSE LEAF SKIMMER TREE / STUMP REMOVAL REMOVE EXISITING CONCRETE PUMP POOL PATIO SCREEN ENCLOSURE ELECTRICAL POOL PATIO EXISTING PATIO DECK DRAIN GALLON CAPACITY-POOL 14,523 GAL. GALLON CAPACITY-SPA 900 GAL. TURN-OVER RATE TERMITE TREAT BARRIER MAX. LENGTH 30' 3.5'MAX. DEPTH 6' CUST HAUL ELEVATION T.B.D INTERIOR FINISH GEM CS200 PUMP MAKE PER FRC 4101.20 JANDY P.H.P.M POOL SPA 2.0 HP INCL POOL 4 COLOR LED SPA 1 COLOR LED POOL 1 100 WATT SPA POOL 1 SPA NA 1 POOL 3 SPA 2 JETS:POOL 2 SPA 10 INCL FILL LINE INCL TO GROUND PLC 1400 PURE LINK PANEL NA JANDY RS8 NA SLIDE NA JANDY JE 3000 ELECTRIC HEAT PUMP INCL INCL INCL POLE BRUSH TEST KIT INCL INCL INCL NA INC NA INC CONCRETE FLO-CRETE INC 6 hrs INC INC NA FLO-CRETE MAX. WATER VELOCITY - 10 ft./s SKIMMER MIN. FLOW 25 GPM SURFACE AREA OF POOL – 479 SQ. FT. 103 LN. FT. SPECIFICATIONS POOLS, INC. 1 100 WATT CONCRETE 2.7 HP 117 G.P.M. 2.0 H.P. 147 G.P.M. 1/4" PER FT. SLOPEBULLNOSE BRICK COPING 6"X6" TILE INTERIOR FINISH 4 1/2" TYP. WALL STEEL-TEX FORM OR KRAFT WALL #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. TO PUMP 6" TYP. FLOOR THREADED PLUG GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL GRAVEL BED NOTE: REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL TYPICAL WALL SECTION & WELL POINT (NO SCALE) RETURN LINE WASTE SKIMMER PIPING SCHEMATIC (NO SCALE) FILTER HAIR & LINT CATCHER (COMPONENT OF PUMP) PUMP ALL PLUMBING SCH. 40 PVC. SUCTION SIDE 2" RETURN SIDE 2" MUST HOLD 35 PSI FOR AT LEAST 30 MIN. TO MAIN SERVICE PANEL IN APPROVED CONDUIT (SIZED PER LOAD) WIRING TO POOL LIGHT IN APPROVED CONDUIT UL APPROVED DECK BOX FOR DIRECT CONNECTION TO WET NICHE UNDERWATER LIGHT NOTE: POOL PUMP MOTOR LOCATED ABOVE GRADE. PROVIDE SEPARATE CIRCUIT FOR PUMP MOTOR(S)AND HEATER(S) ETC ELECTRICAL DIAGRAM AND GFI OUTLET PER 2017 NEC (NO SCALE) RAIN TIGHT OUTDOOR ELECTRICAL PANEL (SIZED PER LOAD) APPROVED WIRING IN 1" SCH 40 PVC W/ #8 BONDING CONDUCTOR POOL LIGHT SWITCH EITHER INDOOR OR OUTDOOR G.F.I OUTLET NOTE: INSTALL 125V 15 AMP WEATHERPROOF DUPLEX RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL · NOTES: · (1) POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE POOL · · (2) ALL ELECTRICAL WIRING AND EQUIPMENT MUST INSTALLED IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE · · (3) PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS PER HO-26 OF NFPA 70 OUTDOOR TIME-CLOCK PUMP MOTOR PRESSURE GAUGE 2.7 HP TILED STEP EDGES TILED BENCH EDGE 3000 FIBER MESH CONCRETE FLO-CRETE POOL PATIO AREA 3.5' DEEP R R H H H H H 0 003' 30' 3.5' 6' 27' CYCOLAC MAIN DRAIN LIGHT 1 ROW OF WATERLINE TILE 1' R #3 STEEL @ 12" O/C E.W. 6" THICK WATERLINE DECK WALLS SHALL NOT SLOPE GREATER THAN 11 FLOOR SLOPES FLOOR SLOPES SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLES 5.6.1 THRU 5.6.3 THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FOOT 4 ½” THICK TYPICAL SECTION THRU POOL (NO SCALE) N.T.S. R R R COLOR LED DECO DRAIN FLUSH SPA CONCRETE FLO-CRETE POOL PATIO AREA REAR SET BACK LINE 4 ft.3 ft.39 ft. 8 ft.8 ft. 4 in.5 ft.5 ft.5 ft. 4 in.3' DEEP H STEP SKIMMER COLOR LED COLOR LED FLO-CRETE EXISTING CONCRETE EXISTING A/C PAD 14 ft.33 ft.30 ft.12 ft.4 ft.SAW CUT AND REMOVE THIS 7' WIDE X 8' TALL PORTION OF CONCRETE TO BUILD POOL AND SPA 21 ft. 4 in.29 ft.40 ft. (3) LAMINAR JANDY DECK JET WATER FEATURES H H H H 1 ft. EXISTING PROPERTY LINE FENCE TO BE BROUGHT TO POOL BARRIER CODE WITH SELF CLOSING AND SELF LATCHING GATES TO COMPLY WITH BARRIER A. ALLEN ENGINEERING LLC, CA NO. 33042, 2367 7TH STREET, LA VERNE, CA, 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY MINIMUM BUILDING CODES. Aaron H. Allen PE, FL Reg. No. 86620 FL · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE UNBLOCKABLE CHANNEL DRAIN SPA DETAIL 8 FPS MAX 2.5" SUCTION LINE TO PUMP MAX 117 G.P.M. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 3" SUCTION LINE TO PUMP MAX 181 G.P.M. 8 FPS MAX 8 FPS MAX TO JET PUMP TO FILTRATION PUMP RETURN LINES FOR SPA 2.5" TO FIRST TEE · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE OVERHEAD ELECTRICAL SERVICE LOCATED ON SITE PLAN FURTHER THAN 10' FROM WATERS EDGE *LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 18" 20" max. N.T.S. SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE REC. PUMP/ WTR FTR = 2.70 HP JANDY FHPM VARIABLE SPEED LOW SPEED – 36 GPM MAX HIGH SPEED = 117 GPM @ 50 TDH 2.5" SUCTION PIPE @ 117 GPM = 7.98 FT/SEC. (8 FT./SEC. MAX. – SUCTION LINES) 3" BRANCH PIPE @ 117 GPM = 5.74 FT./SEC. (6 FT./SEC. MAX. – PRESSURE LINES) 2.5" PRESSURE PIPE @ 117 GPM = 7.98 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 340 SQ. FT. CARTRIDGE FILTER X 0.375 = 127.50 GPM BACKWASH VALVE NO THERAPY PUMP = 2HP JANDY PLUS PHPM LOW SPEED = 36 GPM MAX. HIGH SPEED = 147 GPM @ 35 GPM MAX. 3" SUCTION PIPE @ 147 GPM = 7.29 FT./SEC. (8FT./SEC. MAX. – SUCTION LINES) 2.5" PRESSURE PIPE @ 147 GPM = 7.99 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) ANSI-15 S.P.S.T. TOGGLE SWITCH 1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE. 2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) 5. (1) SPA LIGHT (GFI NOT REQUIRED) #8 SOLID CU GROUND WIRE TO EXISTING PANEL 60 AMP POOL PANEL W/(3) - #4 THHN CU WITHIN 1” ELECTRICAL CONDUIT (4) POOL LIGHTS (GFI NOT REQUIRED) 2HP JANDY PLUS HP PUMP MOTOR W/ BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITHIN ½” MIN. CONDUIT MANUAL MOTOR SWITCH VARIABLE SPEED FLOPRO PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT HEATER SWITCH 3- #6 THHN CU WITHIN 3/4” CONDUIT W.L. 18" MIN. ( ENTIRE PERIMETER) #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS (ONE ON EACH SIDE OF POOL 4 TOTAL ) 8 GAUGE SOLID COPPER WIRE EQUIPOTENTIAL BONDING GRID DETAIL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED) SOIL MINIMUM 18" FROM EDGE OF POOL NO FURTHER THAN 24" AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP PAVER DECK OR CONCRETE DECK SPA JET PUMP HIGH SPEED LOW SPEED JANDY PRO SERIES VS FloPro Series Pump VS-FHP2.7 Performance Curve LOCATION OF WATER BOND BY POOL EQUIPMENT PB-2008 WATER BONDING WIRE TO GRID POOLBOND PB-2008 IN ACCORDANCE WITH 680.2 C POOL WATER SHALL BE IN DIRECT CONTACT WITH AN APPROVED CORROSION-RESISTANT CONDUCTIVE SURFACE THAT EXPOSES NOT LESS THAN 9 INCHES (5800 MM) OF SURFACE AREA TO THE POOL WATER AT ALL TIME. N.T.S FOOTER DETAIL 8" NO SCALE (2) #3 REBAR 8" *REBAR SHALL BE COVERED BY CONCRETE MIN 3-INCHES* UNDERWATER LIGHT DETAIL (NO SCALE) POOL FINISH CONTINUOUS BOND WIRE COMMON TO POOL STEEL, RAILS & EQUIPMENT 1" LIGHT CONDUIT COPING UNDERWATER LIGHT 1.5" PVC NO NICHE 4" MIN.JANDY NICHELESS LED LIGHT 4 ½” F P J P SALT 30" MIN. CLEARANCE IN FRONT OF SUBPANEL VERIFY EXACT LOCATION IN FIELD WITH SUPERVISOR EQ. LAYOUT FILTRATION PUMP/ WATER FEATURE PUMP INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL 1. 2.5" RETURN TO JETS 2. 3" SPA MAIN DRAIN LINE 3. 2.5" POOL MAIN DRAIN LINE 4. 2" VAC SUCTION LINE 5. 2" SKIMMER SUCTION LINE 6. 2.5" SPA MAIN DRAIN LINE 7. 2.5" POOL RETURN LINE TO FIRST TEE 8. 2.5" SPA RETURN LINE 9. 2.5" WATER FETURE MAIN DRAIN LINE 10. 2.5" RETURN TO FIRST VALVE 2" LINE TO BUBBLER 11. 2" RETURN TO LAMINAR DECK JETS 12. 2" RETURN TO HYRDRO JETS A. JANDY FLO PRO 2.7 HP VARIABLE SPEED W/APPR HAIR & LINT STRAINER B. 1.5" TO WASTE OR TO GROUND C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE D. JANDY JE3000 ELECTRIC HEAT PUMP E. VALVES (TYP) F. JANDY “AQUA-PURE SALT SYSTEM G. JANDY 2HP JET PUMP WITH APPR. HAIR & LINT STRAINER H. WATER BOND I. JANDY FLO PRO 2.7 HP VARIABLE SPEED W/APPR HAIR & LINT STRAINER LEGEND E EQUIPMENT LAYOUT N.T.S. D C F 8 6 7 3 H A B 5 124 G FLOATING POOL ALARM PER NSF CERTIFIED TO ASTM F 2208-08 POOL ALARM AUTOFILL AND OVERFLOW 1" 2" 2" 1" 1" 1.5"1.5" 2" 2" 1.5" 1.5" 1.5" 1" 2" 1.5" 1" 2" 2" 2.5" 2.5" TILED SPILLWAY SPA LINK 1" UMBRELLA SLEEVE 2.5" 2.5" POOL BARRIER PER FRC 4501.17- 41.1.17.3 AND ANSI/NSPI-5-1995 SAFETY BARRIER PER FRC 4501.17.1.8 ASTM5034-95, ASTM D3787-89, ASTM 653-96 POOL BARRIER PER FRC 4501.17.1.8 DRAIN DETAIL · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 UNBLOCKABLE CHANNEL DRAIN 8 FPS MAX 2.5" SUCTION LINE TO PUMP MAX 117 G.P.M. 2.5" SUCTION LINE MAX 117 G.P.M. 2.5" RETURN LINE TO FIRST TEE 2.5" RETURN LINE TO FIRST TEE WATER FEATURE PUMP TO FILTRATION PUMP H H 2" 1.5" 1.5" COLOR LED 1" I 9 10 1211 2.5" W P VARIABLE SPEED FLOPRO PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT