HomeMy WebLinkAboutHOYT PLANSSTEP DETAIL
1. TREAD IS MIN. OF 10" WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT
IF MORE THAN (3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID
GUNITE 4000 PSI.
MISC. NOTES
1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE
2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM
FINISH FOR VISIBILITY
2. HAND HOLD TO BE INSTALLED AT AREA WHERE DECK
RAISED +6" ABOVE POOL
N.T.S.
10" MIN.
STEP DETAIL
#8 GROUND WIRE
HANDRAIL BONDING DETAIL
WHERE APPLICABLE
PER NATIONAL ELECTRICAL CODE48" MAX WATER
DEPTH
12" MAX.
VAC LINE
6' DEEP
GENERAL NOTES:
1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL
ORDINANCES AND ZONING REGULATIONS.
2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE
GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS)
COMPRESSIVE STRENGTH.
3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE,
SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN.
4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40.
5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL.
6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES.
7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL
CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR.
8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A
DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM.
9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE
10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE
AREA OF THE SUCTION LINE.
11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION
TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION.
12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING,
METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER &
GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER.
13. NO OVERHEAD OPEN WIRE OVER POOL WATER.
14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA.
NO BACK-WASH REQUIRED.
15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE
PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY.
16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING.
JOB NAME: HOYT
ADDRESS: 3426 SOUTHERN PINES DR
PERMIT NO.:
DATE DRAWN: APRIL 27, 2020
DRAWN BY: TRAVIS LEONARD
DESIGNER APPROVAL:
CUSTOMER APPROVAL:
SCALE: 1/4" = 1'
MAX. WIDTH
MIN. DEPTH
14'
SHAPE
FILL FROM EXCAVATION
TILE FILTER
PUMP HP:
TIMER
LIGHTS
TRNFORM:
MAIN DRAIN:
SKIMMER
RETURNS:
VALVED VAC LINE
DISCHARGE LINE
CHLORINATOR
HANDRAIL
DIVING BOARD
HEATER
VACUUM HEAD
VACUUM HOSE
LEAF SKIMMER
TREE / STUMP REMOVAL
REMOVE EXISITING CONCRETE
PUMP POOL PATIO
SCREEN ENCLOSURE
ELECTRICAL
POOL PATIO
EXISTING PATIO
DECK DRAIN
GALLON CAPACITY-POOL 14,523 GAL.
GALLON CAPACITY-SPA 900 GAL.
TURN-OVER RATE
TERMITE TREAT BARRIER
MAX. LENGTH 30'
3.5'MAX. DEPTH 6'
CUST
HAUL
ELEVATION T.B.D
INTERIOR FINISH GEM CS200
PUMP MAKE PER FRC 4101.20 JANDY P.H.P.M
POOL SPA 2.0 HP
INCL
POOL 4 COLOR LED SPA 1 COLOR LED
POOL 1 100 WATT SPA
POOL 1 SPA NA
1
POOL 3 SPA 2
JETS:POOL 2 SPA 10
INCL FILL LINE INCL
TO GROUND
PLC 1400 PURE LINK PANEL
NA JANDY RS8
NA SLIDE NA
JANDY JE 3000 ELECTRIC HEAT PUMP
INCL
INCL
INCL
POLE
BRUSH
TEST KIT
INCL
INCL
INCL
NA
INC
NA
INC
CONCRETE FLO-CRETE
INC
6 hrs
INC INC
NA
FLO-CRETE
MAX. WATER VELOCITY - 10 ft./s
SKIMMER MIN. FLOW 25 GPM
SURFACE AREA OF POOL – 479 SQ. FT. 103 LN. FT.
SPECIFICATIONS
POOLS, INC.
1 100 WATT
CONCRETE
2.7 HP 117 G.P.M. 2.0 H.P. 147 G.P.M.
1/4" PER FT. SLOPEBULLNOSE BRICK
COPING
6"X6" TILE
INTERIOR
FINISH
4 1/2" TYP.
WALL
STEEL-TEX FORM
OR KRAFT WALL
#3 @ 12" O.C.B.W.
NOTE: FOR DEPTHS
GREATER THAN 6' ADD 1-
#3 COVE BAR @ 6" O.C.
TO PUMP
6" TYP.
FLOOR
THREADED
PLUG
GRATE SHALL
BE SECURED IN
PLACE SO
THAT TOOLS
ARE REQUIRED
FOR REMOVAL
GRAVEL BED
NOTE: REMOVE GRATE &
WELL POINT PLUG FROM MAIN
DRAIN & ATTACH AUX. PUMP
LINE WHEN EMPTYING POOL
TYPICAL WALL
SECTION &
WELL POINT
(NO SCALE)
RETURN LINE
WASTE
SKIMMER
PIPING SCHEMATIC
(NO SCALE)
FILTER
HAIR & LINT
CATCHER
(COMPONENT OF PUMP)
PUMP
ALL PLUMBING SCH. 40
PVC. SUCTION SIDE 2"
RETURN SIDE 2"
MUST HOLD 35 PSI FOR AT
LEAST 30 MIN.
TO MAIN SERVICE PANEL IN
APPROVED CONDUIT (SIZED
PER LOAD)
WIRING TO POOL LIGHT IN
APPROVED CONDUIT
UL APPROVED DECK BOX
FOR DIRECT CONNECTION
TO WET NICHE
UNDERWATER
LIGHT
NOTE: POOL PUMP MOTOR LOCATED ABOVE
GRADE. PROVIDE SEPARATE CIRCUIT FOR
PUMP MOTOR(S)AND HEATER(S) ETC
ELECTRICAL DIAGRAM AND GFI
OUTLET PER 2017 NEC
(NO SCALE)
RAIN TIGHT OUTDOOR
ELECTRICAL PANEL
(SIZED PER LOAD)
APPROVED WIRING IN 1"
SCH 40 PVC W/ #8
BONDING CONDUCTOR
POOL LIGHT SWITCH
EITHER INDOOR OR
OUTDOOR
G.F.I
OUTLET
NOTE: INSTALL 125V 15
AMP WEATHERPROOF
DUPLEX RECEPTACLE AT
LEAST 10' AWAY AND
NOT MORE THAN 20'
FROM THE INSIDE WALL
OF THE POOL
· NOTES:
· (1) POOL PANEL AND SWITCHES MUST BE AT
LEAST 5' FROM THE INSIDE WALL OF THE POOL
·
· (2) ALL ELECTRICAL WIRING AND EQUIPMENT
MUST INSTALLED IN ACCORDANCE WITH THE
2017 EDITION OF THE NATIONAL ELECTRICAL
CODE
·
· (3) PROVIDE PROPER WORKING CLEARANCE
SPACES FOR ELECTRICAL EQUIPMENT AS PER
HO-26 OF NFPA 70
OUTDOOR TIME-CLOCK
PUMP
MOTOR
PRESSURE
GAUGE
2.7 HP
TILED STEP EDGES
TILED BENCH EDGE
3000 FIBER MESH
CONCRETE FLO-CRETE
POOL PATIO AREA
3.5' DEEP
R
R
H
H
H
H
H
0
003'
30'
3.5'
6'
27'
CYCOLAC MAIN DRAIN
LIGHT
1 ROW OF WATERLINE TILE
1' R
#3 STEEL @ 12" O/C E.W.
6" THICK
WATERLINE
DECK
WALLS
SHALL
NOT
SLOPE
GREATER
THAN 11
FLOOR SLOPES
FLOOR SLOPES SHALL BE
REASONABLY UNIFORM AND
COMPLY WITH ARTICLES 5.6.1
THRU 5.6.3
THE SLOPE OF THE FLOOR FROM
THE SHALLOW END WALL
TOWARDS THE DEEP AREA SHALL
NOT EXCEED 1 FOOT IN 7 FOOT
4 ½” THICK
TYPICAL SECTION THRU POOL
(NO SCALE)
N.T.S.
R
R
R
COLOR LED
DECO DRAIN
FLUSH SPA
CONCRETE FLO-CRETE
POOL PATIO AREA
REAR SET BACK LINE 4 ft.3 ft.39 ft.
8 ft.8 ft. 4 in.5 ft.5 ft.5 ft. 4 in.3' DEEP
H
STEP
SKIMMER
COLOR LED
COLOR LED
FLO-CRETE EXISTING
CONCRETE
EXISTING
A/C PAD 14 ft.33 ft.30 ft.12 ft.4 ft.SAW CUT AND REMOVE
THIS 7' WIDE X 8' TALL
PORTION OF CONCRETE
TO BUILD POOL AND SPA 21 ft. 4 in.29 ft.40 ft.
(3) LAMINAR JANDY DECK JET WATER FEATURES
H
H
H
H
1 ft.
EXISTING PROPERTY LINE FENCE TO BE BROUGHT TO POOL BARRIER CODE
WITH SELF CLOSING AND SELF LATCHING GATES TO COMPLY WITH BARRIER
A. ALLEN ENGINEERING LLC, CA NO. 33042,
2367 7TH STREET, LA VERNE, CA, 91750
TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND
SPECIFICATIONS COMPLY MINIMUM BUILDING CODES.
Aaron H. Allen PE, FL Reg. No. 86620 FL
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR
RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
UNBLOCKABLE CHANNEL DRAIN
SPA DETAIL
8 FPS MAX
2.5" SUCTION LINE TO
PUMP MAX 117 G.P.M.
APPROVED MAIN DRAIN FRAMES AND GRATES
PER V.G.B. ASME/ANSI 112.19.8-2007
3" SUCTION LINE TO
PUMP MAX 181 G.P.M.
8 FPS MAX
8 FPS MAX
TO JET PUMP TO FILTRATION PUMP
RETURN LINES FOR SPA 2.5" TO FIRST TEE
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR
RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR
SUCTION ENTRAPMENT AVOIDANCE
OVERHEAD ELECTRICAL
SERVICE LOCATED ON SITE
PLAN FURTHER THAN 10'
FROM WATERS EDGE
*LOCATION OF GFI
RECEPTACLE
TO BE DETERMINED IN
FIELD PER NEC 680
18"
20" max.
N.T.S.
SWIMOUTS
WHEN PROVIDED
SHALL BE AT 20" MAX.
BELOW THE
WATERLINE
REC. PUMP/ WTR FTR = 2.70 HP JANDY FHPM VARIABLE SPEED
LOW SPEED – 36 GPM MAX
HIGH SPEED = 117 GPM @ 50 TDH
2.5" SUCTION PIPE @ 117 GPM = 7.98 FT/SEC.
(8 FT./SEC. MAX. – SUCTION LINES)
3" BRANCH PIPE @ 117 GPM = 5.74 FT./SEC.
(6 FT./SEC. MAX. – PRESSURE LINES)
2.5" PRESSURE PIPE @ 117 GPM = 7.98 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
340 SQ. FT. CARTRIDGE FILTER X 0.375 = 127.50 GPM
BACKWASH VALVE NO
THERAPY PUMP = 2HP JANDY PLUS PHPM
LOW SPEED = 36 GPM MAX.
HIGH SPEED = 147 GPM @ 35 GPM MAX.
3" SUCTION PIPE @ 147 GPM = 7.29 FT./SEC.
(8FT./SEC. MAX. – SUCTION LINES)
2.5" PRESSURE PIPE @ 147 GPM = 7.99 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
ANSI-15
S.P.S.T. TOGGLE
SWITCH
1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE.
2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S)
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER.
4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B)
5.
(1) SPA LIGHT
(GFI NOT REQUIRED)
#8 SOLID CU GROUND WIRE
TO EXISTING PANEL
60 AMP POOL PANEL
W/(3) - #4 THHN CU WITHIN 1”
ELECTRICAL CONDUIT
(4) POOL LIGHTS
(GFI NOT REQUIRED)
2HP JANDY PLUS HP PUMP MOTOR W/
BUILT-IN OVERLOAD SWITCH W/3- #10
THHN CU WITHIN ½” MIN. CONDUIT
MANUAL MOTOR SWITCH
VARIABLE SPEED FLOPRO PUMP MOTOR
W/BUILT-IN OVERLOAD SWITCH W/3- #10
THHN CU WITH-IN ½” CONDUIT
TIME CLOCK
W.P. DISCONNECT
HEATER SWITCH
3- #6 THHN CU WITHIN 3/4” CONDUIT
W.L.
18" MIN.
( ENTIRE PERIMETER)
#8 SOLID COPPER
BOND WIRE W/ APPR.
CLAMPS
(ONE ON EACH SIDE
OF POOL 4 TOTAL )
8 GAUGE SOLID COPPER
WIRE
EQUIPOTENTIAL BONDING GRID DETAIL
PER N.E.C. 2017 SEC. 680.26
(WHERE ADOPTED)
SOIL
MINIMUM 18" FROM EDGE OF POOL NO
FURTHER THAN 24" AROUND ENTIRE POOL
PERIMETER BURIED 4" TO 6" DEEP
PAVER DECK OR CONCRETE DECK
SPA JET PUMP
HIGH SPEED
LOW SPEED
JANDY PRO SERIES VS FloPro Series Pump
VS-FHP2.7 Performance Curve
LOCATION OF WATER BOND
BY POOL EQUIPMENT
PB-2008
WATER
BONDING
WIRE
TO GRID
POOLBOND PB-2008
IN ACCORDANCE WITH 680.2 C POOL WATER SHALL BE IN DIRECT
CONTACT WITH AN APPROVED CORROSION-RESISTANT
CONDUCTIVE SURFACE THAT EXPOSES NOT LESS THAN 9 INCHES
(5800 MM) OF SURFACE AREA TO THE POOL WATER AT ALL TIME.
N.T.S
FOOTER DETAIL
8"
NO SCALE
(2) #3 REBAR
8"
*REBAR SHALL BE COVERED BY
CONCRETE MIN 3-INCHES*
UNDERWATER
LIGHT DETAIL
(NO SCALE)
POOL FINISH
CONTINUOUS BOND WIRE
COMMON TO POOL STEEL,
RAILS & EQUIPMENT
1" LIGHT
CONDUIT
COPING
UNDERWATER
LIGHT
1.5" PVC
NO NICHE
4" MIN.JANDY NICHELESS
LED LIGHT
4 ½”
F
P
J
P
SALT
30" MIN. CLEARANCE
IN FRONT
OF SUBPANEL
VERIFY EXACT
LOCATION IN
FIELD WITH
SUPERVISOR
EQ. LAYOUT
FILTRATION PUMP/ WATER FEATURE PUMP
INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10' AWAY AND
NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL
1. 2.5" RETURN TO JETS
2. 3" SPA MAIN DRAIN LINE
3. 2.5" POOL MAIN DRAIN LINE
4. 2" VAC SUCTION LINE
5. 2" SKIMMER SUCTION LINE
6. 2.5" SPA MAIN DRAIN LINE
7. 2.5" POOL RETURN LINE TO FIRST TEE
8. 2.5" SPA RETURN LINE
9. 2.5" WATER FETURE MAIN DRAIN LINE
10. 2.5" RETURN TO FIRST VALVE 2" LINE TO BUBBLER
11. 2" RETURN TO LAMINAR DECK JETS
12. 2" RETURN TO HYRDRO JETS
A. JANDY FLO PRO 2.7 HP VARIABLE SPEED W/APPR HAIR & LINT
STRAINER
B. 1.5" TO WASTE OR TO GROUND
C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF
VALVE
D. JANDY JE3000 ELECTRIC HEAT PUMP
E. VALVES (TYP)
F. JANDY “AQUA-PURE SALT SYSTEM
G. JANDY 2HP JET PUMP WITH APPR. HAIR & LINT STRAINER
H. WATER BOND
I. JANDY FLO PRO 2.7 HP VARIABLE SPEED W/APPR HAIR & LINT
STRAINER
LEGEND
E
EQUIPMENT LAYOUT
N.T.S.
D
C
F
8
6
7
3
H
A B
5 124
G
FLOATING POOL ALARM
PER NSF CERTIFIED TO
ASTM F 2208-08
POOL ALARM
AUTOFILL AND
OVERFLOW 1"
2"
2"
1"
1"
1.5"1.5"
2"
2"
1.5"
1.5"
1.5"
1"
2"
1.5"
1"
2"
2"
2.5"
2.5"
TILED SPILLWAY
SPA
LINK
1"
UMBRELLA
SLEEVE
2.5"
2.5"
POOL BARRIER PER FRC 4501.17-
41.1.17.3 AND ANSI/NSPI-5-1995
SAFETY BARRIER PER FRC 4501.17.1.8
ASTM5034-95, ASTM D3787-89, ASTM 653-96
POOL BARRIER PER FRC 4501.17.1.8
DRAIN DETAIL
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE
FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7
2006 FOR SUCTION ENTRAPMENT AVOIDANCE
APPROVED MAIN DRAIN FRAMES
AND GRATES PER V.G.B. ASME/ANSI
112.19.8-2007
UNBLOCKABLE CHANNEL DRAIN
8 FPS MAX
2.5" SUCTION LINE TO
PUMP MAX 117 G.P.M. 2.5" SUCTION LINE MAX 117 G.P.M.
2.5" RETURN
LINE TO FIRST
TEE
2.5" RETURN
LINE TO FIRST
TEE
WATER FEATURE PUMP TO FILTRATION PUMP
H H
2"
1.5"
1.5"
COLOR LED
1"
I
9 10 1211
2.5"
W
P
VARIABLE SPEED FLOPRO PUMP MOTOR
W/BUILT-IN OVERLOAD SWITCH W/3- #10
THHN CU WITH-IN ½” CONDUIT
TIME CLOCK
W.P. DISCONNECT