Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2950 AICO SEPTIC WELL PERMIT
STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: (Florida Power and Light) PROPERTY ADDRESS: 2950 Aico Rd Fort Pierce, FL 34951 LOT: BLOCK: SUBDIVISION: PERMIT #: 56-SF-2037580 APPLICATION #: AP1466792 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1306322 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] PROPERTY ID #: 1328-132-0025-000-7 [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,500 ] GALLONS / GPD Seotic new CAPACITY A [ ] GALLONS / GPD CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 825 ] SQUARE FEET Drainfield new SYSTEM R [ J SQUARE FEET SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ) FILLED [X] MOUND [ ] I CONFIGURATION: [x] TRENCH [ ] BED [ ] N F LOCATION OF BENCHMARK: Yellow capped IR SE of system. ELEV 22.61 I ELEVATION OF PROPOSED SYSTEM SITE [ 17.001 INCHES FT J[ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 12.001[ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D FILL REQUIRED: [23.00] INCHES EXCAVATION REQUIRED: [ 33.00] INCHES 0 T H E R m size for 3,520 square feet of office space and 2479 square feet of educational area and 12 students. SPECIFICATIONS BY: Brian J Ingram TITLE: Environmental Specialist II APPROVED BY: 2A TITLE: Environmental Specialist II St. Lucie CHD Brian J ngram DATE ISSUED: 03/06/2 20 EXPIRATION DATE: 09/06/2021 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1.4 AP1466792 SE1255736 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a 'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 HEALTH PAYING ON: #:56-SF-2037580 BILL DOC #.56-BID-4722155 CONSTRUCTION APPLICATION #: AP1466792 RECEIVED FROM: Culpepper & Terpeninq, Inc AMOUNT PAID: $ 25.00 PAYMENT FORM: CHECK 053533 PAYMENT DATE: 06/04/2020 MAIL TO: (Florida Power and Light) FACILITY NAME: PROPERTY LOCATION: 2950 Aico Rd Fort Pierce, FL 34951 Lot: Property ID: 1328-132-0025-000-7 EXPLANATION or DESCRIPTION: -1 - OSTDS Revision Block: QUANTITY FEE 1 $ 25.00 RECEIVED BY: EvansJS AUDIT CONTROL NO. 56-PID-4441220 5(,o —S-r —Z cs -TS � 6 STATE OF FLORIDA PERMIT APPLICATION TO CONSTRUCT, REPAIR, MODIFY, OR ABANDON A WELL o , ❑ Southwest PLEASE FILL OUT ALL APPLICABLE FIELDS ❑ Northwest (*Denotes Required Fields Where Applicable) u < ° ❑ St. Johns River `mouth Florida The water well contractor is responsible for completing tjthis form and forwarding the permit application to the Suwannee River appropriate delegated authority where applicable. \000wE/ ❑DEP -- ❑ Delegated Authority (If Applicable) Permit No. 59-30697 Florida Unique ID Permit Stipulations Required (See Attached) 62-524 Quad No. (lU Deli/ne�ation No. CUP/WUP Application No. `J o3-)SC/—tJ ABOVE THIS LINE - FOR OFFICIAL USE ONLY 1, Florida Power & Light Company 700 Universe Blvd Juno Beach FL 33408 (561) 694-4000 *Owner, Legal Name if Corporation *Address 'City State 'ZIP *Telephone Number 2. 2950 Aico Road, Fort Pierce, FL 34945 *Well Location -Address, Road Name or Number, City 3. 132 8-132-002 5-000-7 *Parcel ID No. (PIN) or Alternate Key (Circle One) Lot Block Unit 4. 28 34 South 39 East Saint Lucie County Sec 'on or Land Grant *T wpship *Range *County Subdivjslo Check if 62-524: _Yes o Water Well CniAractor *License umber 'Telephone N ber E-mail Address 6. ress ��a�i-)l all Q� 4L. 7. *Type of Work: A Construction _Repair _Modification _Abandonment _ 8. *Number of Proposed Wells I 9. *Specify Intended Use(s) of Well(s): _Domestic _Landscape Irrigation _Agricultural Irrigation _Bottled Water Supply _Recreation Area Irrigation _Livestock Public Water Supply (Limited Use/DOH) _Nursery Irrigation Commercial/Industria _Public Water Supply (Community or Non-Community/DEP) _Golf Course Irrigation Class I Injection Reason for Repair, Modification, or Abandonment _Site Investigation Lj-uu u u uv-e v _Monitoring _Test rye _Earth -Coupled Geothermal JUN 4 2020 _HVAC Supply HVAC Return Class V Injection: _Recharge _Commercial/industrial Disposal _Aquifer Storage and Recovery _Drainage OM In St Lude CM Remediation: _Recovery _Air Sparge _Other (Describe) A. IROI� MENTAbbMA _Other (Describe) (Note: Not all types of wells are permit d by a given permitting authority) 10.*Distance from Septic System if s2ir200 ft. 11. Facilit )Description ��l(�(stC &1 12. Estimated Start Date 13.*Estimated Well Depth t &ft. *Estimated Casing Depth / (. ft. *Primary Casing Diameter in. Open Hole: From To ft. 14. Estimated Screen Interval: From To ft. 5.*Primary Casing Material: Black Steel Galvanized PVC Stainless Steel Not Cased Other: 6. Secondary Casing: Telescope Casing Liner Surface Casing Diameter in. 7. Secondary Casing Material: Black Steel Galvanized PVC Stainless Steel Ot 8."Method of Construction, Repair, or Abandonment: Auger Cable Tool Jetted Rotary Sonic Combination (Two or More Methods) Hand Driven (Well Point, Sand Point) Hydraulic Point (Direct Push) Horizontal Drilling Plugged by Approved Method Other (Describe) 9. Proposed Grouting Interval for the Primary, Secondary, and Additional Casing: From To Seal Material LBentonite Neat Cement Other ) From To Seal Material L_Bentonite Neat Cement Other ) From To Seal Material L_Bentonite Neat Cement Other ) From To Seal Material LBentonite Neat Cement Other ) 20. Indicate total number of existing wells on site List number of existing unused wells on site 21.*Is this well or any existing wel o water withdrawal on the owner's contiguous property covered under a Cons umptivg/Water Use Permit (CUP/WUP) or CUP/WUP Application? Yes No If yes, complete the following: CUP/WUP No.�C'District Well ID No. 22. Latitude Longitude �j�J/ — U��� / 23. Data Obtained From: GPS Map Survey Datum: NAD 27 NAD 83 WGS 84 1 hereby certify that I will comply with the applicable rules of Title,10, Florida Administrative Code, and that a water I certify that I am the owner of the property, that the information provided is accurate, and that I am aware of my use permit or artifcial recharge permit, if needed, has been or will be obtained prior to commencement of well responsibilities under Chapter 373, Florida Statutes, to maintain or property abandon this well; or, I certify that I am construction. I further certify that all information provided in this application is accurate and that I will obtain the agent for the owner, that the information provided is accurate, and that I have informed the owner of their necessary approval from other federal, stale, or loml governments, if applicable. I agree to provide a well responsibilities as stated above. Owner consents to allowing personnel of this WMD or Delegated Authonty access completion report t Iho islnct within 30 days after completion of the construction, repair, modification, or to the well site during the construction, repair, modification, or abandonment authorized by this permit. abandonment a n by this permit, or the permi a piralion, whichever occurs first ' = l3 y 4— Owners Agent 5nslzo — SiGr6ature6f Contractor `License No. Signature of Owner or Agent *Date Approval Granted By ( Issue Dale Expiration Date r �G/ Hydrologist Approval Initial. Fee Received Receipt No. Check No THIS PERMIT IS NOT VALID UNTIL PROPERLY SIGNED BY AN AUTHORIZED OFFICER OR REPRESENTATIVE OF THE WMD OR DELEGATED AUTHORITY. THE PERMIT SHALL BE AVAILABLE AT THE WELL SITE DURING ALL CONSTRUCTION, REPAIR, MODIFICATION, OR ABANDONMENT ACTIVITIES. DEP Form: 62-532.900(1) Incorporated in 62-532.400(1), F.A.C. Effective Date: October 7, 2010 5 4 ! Page 1 of 2 \\ E 6 I 8 6 \ 4 P.Ov yy �VK 11 ti 4 J s Np• x4.D �N x30 / z2.D IS IT a • F...._.__..___........_........ g .. xs.D xzo 9 QppQoWI D P J U N- A 2020 bb S9_1 9� z FDOH in St Lucie County p ENVIRONMENTAL HEALTH n� o� 1 p a `k'`i_ fire u/off 1 Site Layout Plan O w+,+n,O ,;;'.p do ,rr e, �CUFEE H.W.Barr-STRUCTUeauRAL & Associates, Inc. onrc:sr-:D nr Par«:rm�sorol CIVIL •STRUCTURAL ENGINEERS COnJZJm!-won aJsr a9!-wm iaan.QIAL:Munkm!dA.deq+.ler UOBN-9062 L.AfA kI l_—..','c dir x �rr.w G.gRmoq nAon anw No })alJ x. St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 HEALTH PAYING ON: #: 56-SF-2037580 BILL DOC #:56-BID-4550353 CONSTRUCTION APPLICATION #: AP1466792 RECEIVED FROM: Culpepper & Terpening, Inc AMOUNT PAID: $ 545.00 PAYMENT FORM: CHECK 053331 PAYMENT DATE: 02/11/2020 MAIL TO: (Florida Power and Light) FACILITY NAME: PROPERTY LOCATION: TBD Indrio Rd Fort Pierce, FL 34951 Lot: Property ID: 1333-112-0010-000-3 EXPLANATION or DESCRIPTION: Block: 128 - OSTDS Construction System Inspection Research Fee -1 - Surcharge (All) -1 - OSTDS New Permit Surcharge -1 - OSTDS Construction Application and Plan Review,New 123 - OSTDS Construction Site Evaluation 126 - OSTDS Construction Permit (New or Mod, Amendment) 127 - OSTDS Construction System Inspection 133 - OSTDS Construction Reinspection r)1IANTITV FFF 1 $ 5.00 1 $ 45.00 1 $ 100.00 1 $ 100.00 1 $ 115.00 1 $ 55.00 1 $ 75.00 1 $ 50.00 RECEIVED BY: MontanezNM AUDIT CONTROL NO. 56-PID-4291484 d� STATE OF FLORIDA DEPARTMENT OF HEALTH 1 'G'lp ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM APPLICATION FOR CONSTRUCTION PERMIT PERMIT �5�0 DATE PAID: FEE PAID: RECEIPT #: APPLICATION FOR: [ X] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: Florida Power and Light AGENT: Culpepper & Terpening, Inc TELEPHONE: 772-464-3537 MAILING ADDRESS: 2980 S. 25th Street, Ft Pierce, FL 34981 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION See attached legal description LOT: BLOCK: SUBDIVISION: PLATTED: PROPERTY ID #:l - - -� ZONING: AG-1 I/M OR EQUIVALENT: [ Y /( ) 13z?^ 13a.o�Zs-000-7 N �� PROPERTY SIZE: 128.8 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [X]<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ Y /QN ] DISTANCE TO SEWER: N/A FT PROPERTY ADDRESS: .± dr _ n a" Z75o AC,, R c> DIRECTIONS TO PROPERTY: North on I-95, West on Inrio Road, first left West of I-95 BUILDING INFORMATION [ ] RESIDENTIAL [X] COMMERCIAL Unit Type of No. of Building Commercial/Institutional System Design No Establishment Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC office buildin 3&OUyo 1 office and learning�T 2SSo 5,999 school per studen- t 2 center 3 4 [ 0 ] Floor/Equ SIGNATURE: DH 4015, 08/09 (C Incorporated 64E- 11111111111�� Drains [ ],,-Other (Specify) QNic 24276 DATA -:� res previous editions which mnOt be usod) FACPage 1 of 4 S% TL GF��/\ AUTHORIZED SEWAGE FLOW: UNOBSTRUCTED AREA AVAILABLE BENCHMARK/REFERENCE POINT LOCATION ELEVATION OF PROPOSED SYSTEM SITE STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Florida Power and Light CONTRACTOR / AGENT: Culpepper & Terpening, Inc LOT: BLOCK: APPLICATION # AP1466792 PERMIT # 56-SF-2037580 DOCUMENT # SF125.5736 SUBDIVISION: ID # : 1328-132-0025-000-7 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 128.82 ACRES TOTAL ESTIMATED SEWAGE FLOW: 660 GALLONS PER DAY [ RESIDENCES —TABLET / OTHER —TABLE 2 ] 322049.00 GALLONS PER DAY [ 1500 GPD/ACRE OR 1 2500 GPD/ACRE ] 10000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1238.00 SQFT Yellow capped IR SE of system. ELEV 22.611 17.00 (FINCHES/ FT ] [ ABOVE / I B ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: FT NORMALLY WET: [ ]YES [ ]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON —POTABLE: FT BUILDING FOUNDATIONS: FT PROPERTY LINES: FT POTABLE WATER LINES: FT SITE SUBJECT TO FREQUENT FLOODING? 10 YEAR FLOOD ELEVATION FOR SITE: QnTT. DD(17TT.7. TW7nVMDTTnM QTTL' 1 [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD USDA SOIL SERIES: Munsell #/Color Texture Depth 1 OYR 4/1 Sand 0 To 7 10YR 5/2 Sand 7 To 26 1 OYR 6/2 Sand 19 To 26 7.5YR 2.5/2 Spodic Material 26 To 33 10YR 4/3 Sand 33 To 39 10YR 6/3 Loamy Sand 39 To 44 1 OYR 6/3 Sand 44 To 48 1 OGY 7/1 Loamy Sand 48 To 59 10YR 7/2 Sand 59 To 72 SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 5/2 Fine Sand 0 To 28 1 OYR 6/2 Fine Sand 19 To 28 7.5YR 2.5/1 Spodic Material 28 To 33 1 OYR 4/3 Sand 33 To 40 1 OYR 6/2 Loamy Sand 40 To 45 10YR 6/3 Sand 45 To 50 1 OGY 7/1 Loamy Sand 50 To 60 1 OYR 7/2 Sand 60 To 72 OBSERVED WATER TABLE: 61.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 19 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES EX ]NO MOTTLING: [X]YES [ ]NO DEPTH: 19.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.80 DEPTH OF EXCAVATION: 33 INCHES DRAINFIELD CONFIGURATION: [X ] TRENCH [ ] BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and soil borings. S6-stripped matrix- 10YR6/2 stripping in 10YR5/2 matrix >10% with diffuse boundaries starting at 19" in S61. SB1 and SB2 17" below BM. SITE EVALUATED BY: DATE: 03/03/2020 Ingram, Brian (TW . Environmental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 08/09 (Obsoletes previous editions whi may not be used) Incorporated: 64E-6.001, FAC Page 3 of 4 AP1466792 EID2037580 v 1.0.2 JDB 1 V���•�/lJ`1i11�CPAKtiId_`_`QK CULPEPPER & TERPENING, INC. SHEET NO OF 2980 South 25th Street • Ft. Pierce, FL 34981 CALCULATED BY DATE (772) 464-3537 • FAX (772) 464-9497 CHECKED BY ce DATE Z� SCALE • I 5iZ 3 Uh C G1 4n _ rov _ (7.1 tA _ I .— — — -- -- - -IQ— Property Card Page 1 of 1 Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property Identification Site Address: 2950 Aico RD Parcel ID: 1328-132-0025- Account #: 5542 Sec/Town/Range: 000-7 28/34S/39E Map ID: 13/28N Zoning: AG-1 Count Use Type: 9900 Jurisdiction: Saint Lucie County Ownership Florida Power And Light Company 700 Universe Blvd PSX/J13 Juno Beach, FL 33408 Legal Description 28/33 34 39 SW'/4 THAT PART OF NE'/4 AND S %z OF NW '/ OF SEC 28 LYG WLY OF RD R/W Ll OF 1-95- LESS THAT PART OF N 200 LYG IN SEA OF NW/4- AND SW/4 OF SEC 28 THAT PART OF N'/z OF SEC 33 LYG WLY OF W R/W I-95-LESS CANAL R/W AND LESS PROPOSED ST LUCIE BV R/W AS IN OR 710-2734 AND LESS THAT PART MPDAF: FROM NW COR OF SEC, TH S 00 41 38 W 230.34 FT TO POB; TH CONT S 00 4138 W 2325.06 FT TO CURVE CONC N, R OF 11,100 FT, TH ELY ALG ARC 1317.27 FT TO CURVE CONC S, R 11,600 FT, TH ELY ALG ARC 1424.80 FT, TH S 89 27 51 E 1141.44 FT, TH N 00 32 09 E 46.11, TH N 87 05 10 E 612 FT TO CURVE CONC NW, R OF 250 FT, TH NELY AND NLY ALG ARC 430.74 FT, TH N 1138 00 W 505.30 FT TO WLY RD R/W LI OF I-95, TH N 20 28 29 W ALG R/W LI 181.60 FT, TH N 90 00 00 W 4059.72 FT, TH N 22 12 00 W 1239.77 FT TO POB- (422.524 AC - 18,405,145 SF) (OR 3905-2775) Current Values Historical Values 3-year Just/Market: $54,900 Assessed: $54,900 Year Just/Market Assessed Exemptions Taxable Exemptions: $0 Taxable: $54,900 2019 $54,900 $54,900 $0 $54,900 2018 $54,924 $1,095 $0 $1,095 2017 $29,850 $1,095 $0 $1,095 Sale History Date Book/Page Sale Code Deed Grantor Price 08-18-2016 3905 / 2775 0311 SP Gray Sky Investments LLC $100 06-23-2016 3884 / 2902 0205 SP Sunbreak Farms Horizon LLC $2,681,800 10-22-2015 3809 / 1025 0205 SP Metropolitan Life Insurance Co $3,000,000 Irriag ° 01' Sketch C n ovcil'a b le: for 'disp/ay Type Total Areas Finished/Under Air (SF): Gross Sketched Area (SF): Land Size (acres): Land Size (SF): Total Building Count: Special Features and Yard Items Qty Units Year Bit 0 0 422.52 18,405,145 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved. https://www.paslc.org/RECard/ 6/4/2020 S(,,sF- Z a37',S� January 23, 2020 TO: St. Lucie County Public Health Department RE: FPL Interstate Educational & Operational Facility On behalf of Florida Power & Light Company, we hereby authorize Culpepper & Terpening, Inc. to act as our agent relative to agency approvals for the above referenced property and project. Florida Power & Light Company By: ! �r=.'(c l.. �' 2° 1 C,��- 1 /23/2020 Mr. Jon Lawrence General Manager — FPL Solar & Storage The foregoing instrument was acknowledged before me this 23rd clay of January, 2020 by Jon Lawrence as GM FPL Solar & Storage, for Florida Power & light Company, who is personally known to me on behalf of Florida Power & Light Company. [Notary Seal or Stamp] NMCYFLFMMO MY COMMISSION N GG am '•?� W E)PIRES: May 20, 2023 " P�tr�'' Bated 1M+i Nofry P+�DIfo Un6NwrR4h Notary Public -State of Florida1 Print Name: Nancy Flemming My Commission Expires:�l� SG-5�-2n3750 COMBINED LEGAL DESCRIPTION FOR FPL INTERSTATE SOLAR (NOVEMBER 2019) LEGAL DESCRIPTION INTERSTATE SOLAR A PORTION OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST, AND A PORTION OF SECTION 33,TOWNSHIP 34 SOUTH, RANGE 39 EAST, SAID LANDS SITUATE AND BEING IN ST. LUCIE COUNTY, FLORIDA AND BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: THAT PART OF THE NORTHEAST 1/4 OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST, LYING WESTERLY OF THE RIGHT OF WAY FOR INTERSTATE 95, AND THE SOUTH 1/2 OF THE NORTHWEST 1/4 OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST, LYING WESTERLY OF THE RIGHT OF WAY FOR INTERSTATE 95, ST. LUCIE COUNTY, FLORIDA, LESS AND EXCEPTING THEREFROM THE NORTH 200 FEET OF THAT PART THEREOF SITUATE AND BEING WITHIN THE SOUTHEAST 1/4 OF THE NORTHWEST 1/4 OF SAID SECTION 28 LYING WESTERLY OF THE RIGHT OF WAY FOR INTERSTATE 95. TOGETHER WITH AND SUBJECT TO THOSE CERTAIN EASEMENTS CONTAINED IN THE FOLLOWING A) THAT CERTAIN WARRANTY DEED GIVEN BY ST. LUCIE GROVES INVESTMENTS, LTD. TO EDGAR A. BROWN, AS TRUSTEE, DATED JANUARY 18, 1993 AND RECORDED IN OFFICIAL RECORDS BOOK 824, PAGE 2323, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. B) THAT CERTAIN DECLARATION OF EASEMENTS AND COVENANTS MADE BY EDGAR A. BROWN, INDIVIDUALLY AND AS TRUSTEE, AS DECLARANT, DATED MARCH 26, 1993 AND RECORDED IN OFFICIAL RECORDS BOOK 834, PAGE 2383, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. TOGETHER WITH: THE WEST 1/2 OF THE SOUTHWEST 1/4 OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA. TOGETHER WITH: THE WEST 1/2 OF THE NORTHEAST 1/4 OF THE SOUTHWEST 1/4 OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA. TOGETHER WITH: THE EAST 1/2 OF THE NORTHEAST 1/4 OF THE SOUTHWEST 1/4 OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA. TOGETHER WITH: THE SOUTHEAST 1/4 OF THE SOUTHWEST 1/4 OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST AND THAT PART OF THE SOUTHEAST 1/4 OF SECTION 28, TOWNSHIP 34 SOUTH, RANGE 39 EAST, LYING WESTERLY OF THE RIGHT-OF-WAY FOR INTERSTATE 95, ST. LUCIE COUNTY, FLORIDA. CULPEPPER & Page 1 of 2 TERPENING INC TOGETHER WITH AND SUBJECT TO THOSE CERTAIN EASEMENTS CONTAINED IN THE FOLLOWING: A) THAT CERTAIN WARRANTY DEED GIVEN BY ST. LUCIE GROVES INVESTMENTS, LTD. TO EDGAR A. BROWN, AS TRUSTEE, DATED JANUARY 18, 1993 AND RECORDED IN OFFICIAL RECORDS BOOK 824, PAGE 2323, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. B) THAT CERTAIN DECLARATION OF EASEMENTS AND COVENANTS MADE BY EDGAR A. BROWN, INDIVIDUALLY AND AS TRUSTEE, AS DECLARANT, DATED MARCH 26, 1993 AND RECORDED IN OFFICIAL RECORDS BOOK 834, PAGE 2383, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. TOGETHER WITH: THE NORTH 1/2 OF SECTION 33, TOWNSHIP 34 SOUTH, RANGE 39 EAST, LYING WEST OF 1-95, EXCEPTING THEREFROM, HOWEVER, THE SOUTH 75 FEET THEREOF, ALSO LESS AND EXCEPT PROPOSED ST. LUCIE BLVD., AS DESCRIBED IN OFFICIAL RECORDS BOOK 710, PAGE 2734, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. SAID LANDS CONTAINING 23,480,706.67 SQUARE FEET OR 539.04 ACRES. EXCEPTING AND RESERVING: A PARCEL OF LAND LYING IN THE NORTH 1/2 OF SECTION 33, TOWNSHIP 34 SOUTH. RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA AND MORE PARTICULARLY DESCRIBED AS FOLLOWS; COMMENCING AT THE NORTHWEST CORNER OF SECTION 33 REFERRED TO ABOVE AND RUNNING THENCE S00°41'38"W (BASIS OF BEARINGS) ALONG THE WESTERLY LINE OF SAID SECTION A DISTANCE OF 230.34 FEET TO THE POINT OF BEGINNING, - THENCE SO°41'38"W, STILL ALONG THE WESTERLY LINE OF SAID SECTION 33, A DISTANCE OF 2325.06 FEET TO A POINT ON THE NORTHERLY BOUNDS OF A PARCEL OF LAND CONVEYED BY ST. LUCIE GROVE INVESTMENTS LTD. TO ST. LUCIE COUNTY BY DEED RECORDED IN OFFICIAL RECORDS BOOK 710 AT PAGE 2734, PUBLIC RECORDS OF SAID ST. LUCIE COUNTY, FLORIDA, WHICH POINT IS LOCATED N00°41'38"E A DISTANCE OF 105.37 FEET FROM THE WEST 1/4 CORNER OF SAID SECTION 33; THENCE ALONG THE BOUNDS OF THIS LAST MENTIONED CONVEYANCE THE FOLLOWING 7 COURSES; 1) EASTERLY ALONG A CURVE TO THE LEFT CONTAINING THE FOLLOWING ELEMENTS, - RADIUS 11100.00 FEET, CENTRAL ANGLE 6°47'58"; ARC LENGTH 1317.27 FEET; CHORD BEARING N86°53'53"E, A CHORD DISTANCE OF 1316.50 FEET TO A POINT OF REVERSE CURVATURE; 2) EASTERLY ALONG A CURVE TO THE RIGHT CONTAINING THE FOLLOWING ELEMENTS; RADIUS 11600.00 FEET, CENTRAL ANGLE 7°02'15", ARC LENGTH 1424.80 FEET, CHORD BEARING N87°01'01"E, A CHORD DISTANCE OF 1423.90 FEET TO A POINT OF TANGENCY: 3) S89°27'51"E A DISTANCE OF 1141.44 FEET TO A POINT; 4) NO°32'09"E A DISTANCE OF 46.11 FEET TO A POINT; 5) N87°05'10"E A DISTANCE OF 612.00 FEET TO A POINT OF CURVATURE; 6) NORTHEASTERLY AND NORTHERLYALONG A CURVE TO THE LEFT CONTAINING THE FOLLOWING ELEMENTS; RADIUS 250.00 FEET, CENTRAL ANGLE 98°43'10", ARC LENGTH 430.74 FEET, CHORD BEARING N37°43'35"E, A CHORD DISTANCE OF 379.41 FEET TO A POINT OF TANGENCY; 7) N11°38'00"W A DISTANCE OF 505.30 FEET TO A POINT ON THE WESTERLY RIGHT-OF-WAY OF INTERSTATE 95; THENCE DEPARTING THE BOUNDS OF THE ABOVE MENTIONED CONVEYANCE TO ST. LUCIE COUNTY AND RUN N20°28'29"W ALONG SAID RIGHT-OF-WAY, A DISTANCE OF 181.60 FEET TO A POINT; THENCE N90°00'00"W, DEPARTING SAID RIGHT-OF-WAY, A DISTANCE OF 4059.72 FEETTO A POINT; THENCE N22°12'00"W A DISTANCE OF 1239.77 FEET TO THE POINT OF BEGINNING. EXCEPTING PARCEL CONTAINING 120.126 ACRES OF LAND, MORE OR LESS. THE NET AREA OF THE ABOVE DESCRIBED PARCEL IS 418.914 ACRES OF LAND, MORE OR LESS CULPEPPER & Page 2 of 2 TERPENING INC Z �O I V ff f I II O a N � N U :3 a O m a� ry 'o o U U E O w U I � t i M.05.9Z.08 '-.. OOZ060E z ZD N R 09ZAWE ouov E r r' F _ _ 56 5l- - Z63 75 SV 061060E 096060E OE WC OSZOWC 03 m60E 061060E 091060E 0E1060E Z r� N 006060E M „Ob,9Z .08 �~ 8 o_ i c9 z v A rn m x � 5� C E w H DyC ryN c7S a m m o o Z M.OS.9Z .09 DOE z 0 N R N STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: (Florida Power and Light).-', PROPERTY ADDRESS: TBD Indrio Rd LOT: BLOCK: PROPERTY ID # : 1333-112-0010-000-3 SUBDIVISION! PERMIT #:56-SF-2037580 APPLICATION #: AP1466792 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1306322 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1,500 ] GALLONS / GPD Septic new CAPACITY A [ ] GALLONS / GPD CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 825 ] SQUARE FEET Drainfield new SYSTEM R [ ] SQUARE FEET SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [x] MOUND [ ] I CONFIGURATION: [x] TRENCH [ ] BED [ ] N F LOCATION OF BENCHMARK: Yellow capped IR SE of system. ELEV 22.61 I ELEVATION OF PROPOSED SYSTEM SITE [ 17.00][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 12.00][ INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT L D O T H E R FILL REQUIRED: [23.00] INCHES EXCAVATION REQUIRED: [ 33.001 INCHES System size for 3,520 square feet of office space and 2479 square feet of educational area and 12 students. SPECIFICATIONS BY: B J I TITLE: APPROVED BY: DATE ISSUED rian ng Environmental Specialist II / TITLE: Environmental Specialist II Brian J Ing 03/06/2020 EXPIRATION DATE: DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC St. Lucie CHD 09/06/2021 Page 1 of 3 v 1.1.4 AP1466792 SE1255736 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413 8743 . Mediation is not available as an,.a It6mative remedy Your failure to submit a petition, for Hearing :within 2f days from receipt of this order will constitute a waiver of your right to an ad"mrnistrative hearing; and this order shall become a 'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Florida Power and Light CONTRACTOR / AGENT: Culpepper & Terpening, Inc LOT: BLOCK: SUBDIVISION: ID# : 1333-112-0010-000 APPLICATION # AP1466792 PERMIT # 56-SF-2037580 DOCUMENT # SE1255736 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT! EMPLOYEE,. '.iO1t OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE:;OF SUBMITTAL.,,COMPLETEjALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO _ NET USABLE AREA AVAILABLE: 128.82 ACRES TOTAL ESTIMATED SEWAGE FLOW: 660 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 322049.00 GALLONS PER DAY [ 1500 GPD/ACRE OR 1 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 10000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1238.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Yellow capped IR SE of system. ELEV 22.61 ELEVATION OF PROPOSED SYSTEM SITE 17.00 [ INCHES]/ FT ] [ ABOVE / r ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: FT NORMALLY WET: [ ]YES [ ]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: FT BUILDING FOUNDATIONS: FT PROPERTY LINES: FT POTABLE WATER LINES: FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOTT. PROFTT,F. TNFORMATTON STTE I SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 4/1 Sand 0 To 7 1 OYR 5/2 Sand 7 To 26 1OYR 6/2 Sand 19 To 26 7.5YR 2.5/2 Spodic Material 26 To 33 1 OYR 4/3 Sand 33 To 39 1 OYR 6/3 Loamy Sand 39 To 44 1 OYR 6/3 Sand 44 To 48 1OGY 7/1 Loamy Sand 48 To 59 1 OYR 7/2 Sand 59 To 72 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 5/2 Fine Sand 0 To 28 1 OYR 6/2 Fine Sand 19 To 28 7.5YR 2.5/1 Spodic Material 28 To 33 1 OYR 4/3 Sand 33 To 40 1 OYR 6/2 Loamy Sand 40 To 45 1 OYR 6/3 Sand 45 To 50 1OGY 7/1 Loamy Sand 50 To 60 1 OYR 7/2 Sand 60 To 72 1-7 OBSERVED WATER TABLE: 61.00 INCHES [ ABOVE /-'BELOW]] EXISTING GRADE TYPE: [ PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 19 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO DEPTH: 19.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.80 DEPTH OF EXCAVATION: 33 INCHES DRAINFIELD CONFIGURATION: [X ] TRENCH [ ] BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and soil borings. S6-stripped matrix-10YR6/2 stripping in 10YR5/2 matrix >10% with diffuse boundaries starting at 19" in SB1. SB1 and S132 17" below BM. SITE EVALUATED BY: DATE: 03/03/2020 Ingram, Brian (Title: vironmental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 06/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 Of 4 AP1466792 EID2037580 v 1.0.2 JOB �` `�� d 7ll�i"`"• �j �i! 6'�Q� CULPEPPER & TERPENING, INC. SHEET NO c� OF 2980 South 25th Street i Ft. Pierce, FL 34981 CALCULATED BY �.1 . DATE (772) 464-3537 • FAX (772) 464-9497 CHECKED BY DATE SCALE G- — — - -- S --� - vac,_ 'l — c � 5 ,.- ---- — — —