HomeMy WebLinkAboutEngineer Reportrnrs:�3 ENGINEERING & TESTING, INC. Phone: (866) 781-6889 *Fax: (860) 78 4-8550 )),ii)` floridaengineeringaiultesting.com 250 S.W. 13t" Avenue Pompano Beach, FL 33069 DATE: 6/08/20 JOB ORDER 9: 20-2276 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, FL 34982 PROJECT: St Lucie Classroom Teachers Assoc. - Flat Insulated Wood Deck ADDRESS: 371 E. Midway Road Fort Pierce, FL 34982 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Project Information: Height = 9' Exposure: C Basic/Ultimate Wind Speed: Vuit=170 mph Length = 49' Category: I1 Nominal Wind Speed: Vasd=VUlt*�0.6 Width = 48' Slope: < 7° (asd = allowable strength design) Parapet Wall: < 3' Commercial KZ = 0.85, Kzt = 1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KZKZtKdV2 Velocity Pressure (,it): q=0.00256(0.85)(1.0)(0.85)(170)2 = 53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*�0.6)2 = 32.07 psf Width of Pressure Coefficient: 0.1(48') = 4.8' 0.4(9') = 3.6' } use: 4'0" Effective Wind Area: <1 Oft2 For parapet height three feet (T) or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCPi = 0.18 - 4 \1 Q+ if Qrcalitrl A ly .fdssccrance Page 2, 6/08/20, Job Order #20-2276 z All Area Roofing - Flat Insulated Wood Deck FU01t11PA St Lucie Classroom Teachers Assoc. 371 E. Midway Road; Fort Pierce, FL: DesijZn Pressures Based on Vasd: 1) Field P1 = 32.07*[(-1.0) — (0.18)] = -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8) — (0.18)] = -63.5 psf 3) Corners P3 = 32.07* [(-2.8) — (0.18)] = -95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of Florida Product Approval # FL1654-R26, Appendix 1, pg 17 of 81, System No. W-73, with a maximum design pressure of-75psf, the following are our recommended fastening patterns to attach the proposed base sheet through the preliminarily attached insulation layer(s) to the min. 15/32" plywood deck utilizing approved fasteners and plates (Dekfast # 14 Fasteners with Dekfast Hex Plates; OMG HD Fasteners with OMG 3" Round Metal Plates; Roofgrip # 14 Fasteners with OMG Flat Bottom Plates; Trufast HD Fasteners with Trufast 3" Metal Insulation Plates): Field: 10" o.c. @ 4" laps and 3 staggered rows 10" o.c. Perimeter: 10" o.c. @ 4" laps and 3 staggered rows 10" o.c. Corners: 10" o.c. @ 4" laps and 5 staggered rows 10" o.c. *Note: If any portion of the anchor/base sheet falls within the perimeter or corner zones, then the entire sheet has to be fastened to the requirements of that zone. Notes: Corners and perimeter area dimension shall not be less than a = 4,0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. AN �M''��,,,���� =�t�� '�GENS'' Shy Sincerely, V F 2 = o: 48202 O '= Mark A. Mesian&s%E--. STATE OF Florida Engineeriri� T@i �P • ' ��'�' Florida Reg. No. 485 Certificate of A-Lithorizaif'an,