HomeMy WebLinkAboutNOA18 1126 06MIMImAIM111
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DWISION
NOTICE OF ACCEPTANCE (NOA)
Firestone Building Products Company,
200 4th Ave. South
Nashville, TN 37201
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 31525.99
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (in Miami Dade County) and/or the AH1(in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product
or material fails to perform in the accepted manner, the manufacturer will incur the expense of such
testing and the A14J may immediately revoke, modify, or suspend the use of such product or material
within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Firestone UltraPly TPO & TPO XR Single Ply Roof Systems over Recover Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-0606.04 and consists of pages 1 through 109.
The submitted documentation was reviewed by Hamley Pacheco, P.E.
L APPROVED I
NOA No.: I9-1126.06
Expiration Date: 02/03/25
Approval Date: 01/M=
Page I of 109
ROOFING SYSTEM APPROVAL
Catevorv:
Roofing
Sub-Cateeorv:
Single Ply Roofing
Material:
TPO
Deck Type:
Recover
Maximum Desi® Pressure:
See Specific Deck Type
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED
BY APPLICANT:
TABLE 1
Test
Product
Dimensions
Specifications
Product Description
UltraPly TPO
Various
TAS 131
Reinforced TPO 0.045" to
ASTM D6878
0.080" thick membrane.
UltraPly TPO XR 100
Various
TAS 131
Reinforced TPO 0.045"
ASTM D6878
membrane with 8 oz. fleece
backing.
UltraPly TPO XR 115
Various
TAS 131
Reinforced TPO 0.060"
ASTM D6878
membrane with8 oz. fleece
backing.
UltraPly TPO XR 135
Various
TAS 131
Reinforced TPO .080"
ASTM D6878
membrane with 8 oz. fleece
backing.
SBS Poly Base
39.4" x 50'
ASTM D6164
Polyester reinforced SBS
modified bitumen membrane
with sanded surfaces.
UltraPly TPO Reinforced
Various
TAS 131
TPO curb flashing
Curb Corner
ASTM D6878
UltraPly 18" Curb
Various
TAS 131
TPO curb flashing
Flashing
ASTM D6878
UltraPly TPO
Various
TAS 131
Molded TPO for comer flashing
Inside/Outside Comer
ASTM D6878
UltraPly TPO Large Pipe
Various
TAS 131
TPO flashing for large round
Flashing
ASTM D6878
penetrations
UltraPly TPO T -Joint
Various
TAS 131
TPO flashing for T joints
Cover
ASTM D6878
UltraPly TPO Penetration
Various
TAS 131
Penetration sealing kit for
Kit
ASTM D6878
UltraPly TPO
UltraPly TPO Walkway
Various
TAS 131
TPO walkway pad
Pad
ASTM D6878
UltraPly TPO Coated
Various
TAS 131
TPO laminated to hot -dipped
Metal
ASTM D6878
galvanized steel for flashing
UltraPly TPO Premium
Various
TAS 131
TPO walkway pad
Walkway Pad
ASTM D6878
NOA No.: IS -1126.06
t*nt+Fpnpeeota+rr Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 2 of 109
NOA No.: M-1126.06
nwnonpEeourrtr Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 3 of 109
Test
Product
Dimensions
Specifications
Product Description
UltraPly TPO Reinforced
Various
TAS 131
TPO flashing for round
Split Pipe Boot
ASTM D6878
penetrations I" to 9" in diameter
UltraPly TPO 8"
Various
TAS 131
8" wide 60 mil TPO cover strip
Reinforced Cover Strip
ASTM D6878
UltmPly TPO Universal
Various
TAS 131
TPO flashing for round
Pipe Boot
ASTM D6878
penetrations V to 6" in diameter
UltraPly TPO
Various
TAS 131
Unreinforced TPO used for
Unsupported Flashing
ASTM D6878
flashing
UltraPly QuickSeam
]W' x 100'
Proprietary
Strip of UltraPly TPO with
R.M.A. Strip
QuickSeam Tape for anchoring
membrane to substrate.
Single -Ply QuickPrime
1 gallon, 3 gallon
Proprietary
Primer for TPO Flashing.
Primer
XR Bonding Adhesive
5 gal. pail
Proprietary
Solvent based adhesive.
UltraPly Bonding
5 gal. pail
Proprietary
Solvent based adhesive.
Adhesive
XR Stick Membrane
5 gal. pail
Proprietary
A low-rise polyurethane, low
Adhesive
VOC, membrane adhesive.
I.S.O. Stick
5 gal &
Proprietary
A dual component polyurethane
1500 ml
adhesive.
I.S.O. Twin Pack
1500 ml
Proprietary
A dual component polyurethane
Insulation Adhesive
adhesive.
I.S.O. Fix 11
30 lbs.
Proprietary
A single component
polyurethane adhesive.
I.S.O. Spray R
15 gal pail &
Proprietary
A two part polyurethane
55 gal drum
adhesive
Single -Ply LVOC
5 gal. pail
Proprietary
Solvent based bonding adhesive.
Bonding Adhesive
Single -Ply LVOC
5 gal. pail
Proprietary
Solvent based bonding adhesive.
Bonding Adhesive 1168
Water Based Bonding
5 gal. pail
Proprietary
Water based bonding adhesive.
Adhesive P
NOA No.: M-1126.06
nwnonpEeourrtr Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 3 of 109
APPROVED INSULATIONS:
Product Name
ISO 95+ GL and tapered
ISOGARD HD
ISOGARD HD Composite
RESISTA and tapered
DensDeck, DensDeck Prime
SECUROCK Gypsum -Fiber
Roof Board
SECUROCK Glass -Mat
Roof Board
APPROVED
TABLE 2
Product Description
Polyisocyanurme foam insulation
Polyisocyanurate with a coated
fiberglass facer
Polyisocyanumte with a coated
fiberglass facer composite insulation.
Polyisocyanurate foam core laminated
to a coated fiberglass facer.
Silicon treated gypsum
Rigid, gypsum -based board stock
Rigid, gypsum -based board stock
Manufacturer
(With Current NOA)
Firestone Building Products
Company, LLC
Firestone Building Products
Company, LLC
Firestone Building Products
Company, LLC
Firestone Building Products
Company, LLC
Georgia Pacific Gypsum LLC
United States Gypsum Corp.
United States Gypsum Corp.
NOA No.: 19-1126.06
Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 4 of 109
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1.
Firestone Heavy -Duty
#15 Fastener for steel,
N/A
Firestone Building
Wood, concrete decks.
Products Company, LLC
2.
Firestone All -Purpose
#14 Fastener for steel,
N/A
Firestone Building
Wood, concrete decks.
Products Company, LLC
3.
Firestone Heavy Duty Plus
Insulation and membrane
Various
Firestone Building
fastener.
Products Company, LLC
4.
Concrete Drive
Structural concrete
Various
Firestone Building
fastener.
Products Company, LLC
5.
Purlin Fasteners
912 purlin fastener.
Various
Firestone Building
Products Company, LLC
6.
Insulation Fastening Plate
Galvalume insulation plate.
3" diameter
Firestone Building
Products Company, LLC
7.
Firestone HD Plus Seam
Galvalume insulation plate.
2'h"
Firestone Building
Plate
diameter
Products Company, LLC
8.
Firestone HD Seam Plates
AZ55 or AZ50 galvalume
2-3/8"
Firestone Building
insulation plate.
diameter
Products Company, LLC
9.
UltraPly TPO Invisi Weld
High-performance TPO
3" diameter
Firestone Building
Plates
membrane fastening
Products Company, LLC
system.
10.
Metal Batten Bar
Galvalume AZ55 batten
10' long, I"
Firestone Building
bar.
wide
Products Company, LLC
11.
Firestone Polymer Batten
Polymer batten
250' long,
Firestone Building
Sip
3/4" wide
Products Company, LLC
12.
Coiled Metal Batten Bar
Galvalume AZ55 batten
220' long, P'
Firestone Building
strip
wide
Products Company, LLC
13.
Two Piece Impact Nail
Base ply fastening systems
Various
Firestone Building
for lightweight concrete
Products Company, LLC
decks
NOA No.: 18-1126.06
Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 5 of 109
EVIDENCE SUBMITTED:
Test Aeencv
Test Identifier
Description
Date
Underwriters Laboratories Inc.
R9516
UL 790
04/26/16
Factory Mutual Research
3032272
FM 4470
05/22/09
Corporation
3036642
FM 4470
10/09/09
3030650
FM 4470
07/10/09
3035560
FM 4470
01/11/10
3019991
FM 4470
09/20/05
3017120
FM 4470
04/30/04
3038546
FM 4470
12/17/10
3039133
FM 4470
04/07/11
3036747
FM 4470
02/12/10
3040535
FM 4470
10/05/10
3035017
FM 4470
04/15/09
3038191
FM 4470
08/04/11
3036256
FM 4470
04/27/09
3038546
FM 4470
12/17/10
3038770
FM 4470
08/04/11
3041939
FM 4470
08/14/12
3044047
FM 4470
05/17/12
3047398
FM 4470
08/15/13
3047700
FM 4470
08/16/13
3050274
FM 4470
10/01/13
797-05830-267
FM 4470
08/30/10
797-10191-267
FM 4470
01/09/15
TrinitylERD
F8300.07.08
TAS 131/ ASTM D6878
07/30/08
F8300.11.08 -R3
TAS 131/ ASTM D6878
02/25/11
F45600.09.13 -R1
TAS 131/ASTM D6878
12/30/13
PRI Construction Materials
FBP-054-02-05, RI
FM 4474/TAS 114 D
02/07/13
Technologies, LLC
FBP-069-02-01, Rl
FM 4474/TAS 114 J
02/07/13
FBP-070-02-01, RI
FM 4474/TAS 114 J
02/07/13
FBP-085-02-01
TAS 1141
10/04/12
FBP-086-02-01
TAS 114J
10/04/12
FBP-044-02-01, R7
TAS 114 H. J
02/04/14
FBP-145-02-01
TAS 131/ASTM D6878
06/26/14
FBP-094-02-01
TAS 131/ASTM D6878
11/20/13
FBP-120-02-01
TAS 114 J
07/23/13
FBP- 122-02-0 1, RI
TAS 114J
02/04/14
FBP-125-02-01
TAS 114 C
07/23/13
FBP-148-02-01
TAS 114 J
12/18/13
FBP-149-02-01
TAS 114 J
12/18/13
FBP-153-02-01
TAS 114 J
12/18/13
FBP-154-02-02
TAS 1141
12/18/13
FBP-165-02-01
TAS 114 J
04/28/14
FBP-165-02-OIA
TAS 114 J
04/28/14
FBP-175-02-01
TAS 114 J
04/28/14
NOA No.: 18-1126.06
MIAMI DADE COUNTY Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 6 of 109
EVIDENCE SUBMITTED: (CONTINUED
Test Agency
PRI Construction Materials
Technologies, LLC
Test Identifier Description
FBP-190-02-01
TAS 114 D
FBP-193-02-02
TAS 114 J
FBP-196-02-04.1
TAS 114J
FBP-206-02-01
TAS 114J
FBP-213-02-01
TAS 114 J
FBP-220-02-01.1
TAS 114J
FBP-225-02-01
TAS 114 J
FBP-230-02-01
TAS 114 J
FBP-233-02-01
TAS 114 J
FBP-233-02-02
TAS 114 C
FBP-233-02-03
TAS 114J
FBP-235-02-01
TAS 1141
FBP-238-02-01
TAS 114 J
FBP-238-02-03
TAS 114 J
FBP-239-02-01
TAS 114 J
FBP-241-02-01
TAS 114J
DECK STRESS ANALYSIS CALCULATIONWREPORTS
Engineer/Agency Identifier
Zachary R. Priest, P.E.
FM Approval Deck
Limitations
B(8), B(9)
E(2), E(3)
Signed/Sealed C(18), C(22), C(23), C(24), C(25), C(41)
Signed
Seale C(i6), C(21). C(29), C(30), D(20), D(21).
CalcuD(4), D(22), D(24)
D(25), E(4), E(8)
C(26), C(27)
Date
07/31/14
10/16/14
10/21/14
02/02/15
11/20/14
01/29/15
03/19/15
04/02/15
06/01/15
04/03/15
06/01/15
06/01/15
07/01/15
07/15/15
07/15/15
07/22/15
06/01/15
04/18/16
10/03/16
09/20/17
10/11/17
07/10/19
N/A C(14), C(15) D(5), D(6), D(7), D(8), D(9), 01/01/13
13(10), 1)(12), D(14), D(16), D(17),1308)
NOA No.: 16-1126.06
MIAMI DADE COUNTY Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 7 of 109
Membrane Type: Single Ply, TPO
Deck Type 71: Recover, Insulated
Deck Description: Steel (Existing Structural Non -Insulated Metal Roof Panel Assembly)
System Type D(3): Membrane mechanically attached over preliminary fastened insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of any of the following insulations.
Base Insulation Layer: To be placed between the Insulation Fasteners Fastener
ribs or over panels of existing structural metal roof (Table 3) Density/ft=
system.
ISO 95+ GL
Minimum I" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
ISO 95+ GL
Minimum 1.5" thick N/A N/A
ISOGARD HD
Minimum %:" thick N/A N/A
DensDeck; DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board, SECUROCK Glass -Mat
Fiber Roof Board
Minimum '/4" thick N/A N/A
Plywood
Minimum 19/32" thick N/A N/A
Note: All insulation shall have preliminary attachment prior to the installation of the roofing
membrane at a minimum application rate of two fasteners per board for insulation boards having
no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension
greater than 8 ft. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Membrane: UltraPly TPO shall be mechanically attached over the top insulation to the purlins
spaced 142" maximum with Firestone HD Seam Plates and Purlin Fasteners.
Fastener rows are placed at a maximum 142" o.c. and fasteners are spaced 6" o.c.
and centered within the 6" wide roof cover side laps. (Areas where the metal
panels do not lay flush on purlin shall have a'/4" pilot pre -drilled into the panel
prior to fastening) Minimum 6" wide side laps are sealed with a minimum 1.5"
wide heat weld on the outside edge of the lap.
Maximum Design
Pressure: -52.5 psf. (See General Limitation #7)
NOA No.: I8-1126.06
HAMM IDECOUDIry Expiration Date: 02/03/25
Approval Date: 01/30/20
Page 70 of 109
RECOVER SYSTEM LIMITATIONS:
1. All System Limitations and General Limitations shall apply. See specific deck type Notice of Acceptance for deck
type System Limitations.
2. All assemblies listed herein shall be installed in compliance with the applicable sections of FBC 1521. Uplift
performance of assemblies bonded to existing roofing system shall be verified per 1521.10. Uplift performance of
assemblies mechanically attached through existing roofing system shall be verified per 1521.11.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The fust layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 IbsJsq., or mechanically attached using the fastening pattern of the
top layer.
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel
size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied
using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three
rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation.
Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross
ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 Ibf, as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are
below 275 lbf. Insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a specific
system. Should the fastener resistance be less than that required, as determined by the Building Official, a
revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered
Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the
withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance
with Roofing Application Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida
registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is
specifically referred within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform
to Roofing Application Standard RAS 11 I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening
at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is
specifically referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 18-1126.06
OMMM
rwuaFwoecoum Expiration Date: 02/03/25
Approval Date: 01/3020