Loading...
HomeMy WebLinkAboutEnergy CodeFORM-NR405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 16 Block 5 Waterston 1820 CGR Builder Name: ADAMS HOMES Street: 5361 San Benedetto Place Permit Office: City, State, Zip: Fort Pierce, FL, 34951 Permit Number. Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St.. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(2120.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft' b. Frame - Wood, Adjacent R=13.0 270.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1820.0 sgfL) Insulation Area a. Under Attic (Vented) R=30.0 1820.00 ft' 6. Conditioned floor area above grade (ft2) 1820 b. N/A R= ft2 Conditioned floor area below grade (112) 0 c. N/A R= ft' 11. Ducts R ft- 7. Windows(239.3 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 364 a. U-Factor: Dbl, U=0.33 168.74 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.33 20.42 112 SHGC: SHGC=0.31 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 17.78 ft' a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.251 ft. Area Weighted Average SHGC: 0.269 14. Hot water systems 8. Floor Types (1820.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft' b. Conservation features EF: 0.940 b. WA R= ft2 None c. NIA R= ft' 15. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 64.03 PASS Total Baseline Loads: 68.84 1 hereby certify that the plans and specifications covered b Review of the plans and S]glA this calculation are in complia the Florid y specifications covered by this OF•110 _ > O 'Ss Code. calculation indicates compliance .�.. y ,,, _ A with the Florida Energy Code. ,e, rnn '•;, :°;• `,`.;;;,�°„ lO PREPARED BY: Before construction is completed =1 DATE: 2-14_917170 Winn Keomany this building will be Inspected for compliance with Section 553.908 O >° I hereby certify that this building, as designed, is in compliance Florida Statutes. !,), with the Flodda.Eagrgy Code. COp Wr' �O OWNER/AGENT t BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). J NOSO 0O0 2/14/2020 12:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Soft®re Page 1 of 4 1=ORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title'. Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 16 Block 5 Waterston 18 Bedrooms: 4 User Conditioned Area: 1820 Total Stories: 1 1 Worst Case: Yes ADAMS HOMES Rotate Angle: 225 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 16 Block/Subdivision: Waterslone PlatBook: Street: 5361 San Benedetto PI County. St. Lucie City, State, Zip: Fort Pierce , FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft' 0.42 0 0.58 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pilch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft' 456 ft- Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1820 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Fmc Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ft' 0.11 Wood 2/14/2020 12:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R4O5-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Spam P o _ 1 NE=>W Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 fl2 0 0 0.6 0 -2 SE=>N Exterior Concrete Block - Int Insul Main 4.1 20 0 10 0 200.0 R2 0 0 0.6 0 3 SW=>E Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 ft2 0 0 0.6 0 -4 NW=>S Exterior Concrete Block - Int Insul Main 4.1 40 0 10 0 400.0 ft2 0 0.6 0 5 =>S Garage Frame - Wood Main 13 27 0 10 0 270.0 ft2 0 0.23 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated Main None .25 3 6 8 20 ft- 2 =>S Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE=>W 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft' 1 It 4 in 0 It 10 in None Exterior 5 2 NE=>W 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 1 O in None Exterior 5 3 SE=>N 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.1 ft- 9 it 4 in 0 ft 0 in None None 4 SE=>N 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 1 8 0 in None None 5 SE=>N 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 It 4 in 1 ft 0 in None Exterior 5 6 SE=>N 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 9 It 4 in 1 ft 6 in None None 7 SW=>E 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 fttO in None Exteriors 8 NW=>S 4 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 12 it 0 in 0 it 6 in None None 9 NW=>S 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 112 1 ft 4 in 0 ft 10 in None Exterior 5 10 NW=>S 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 12 ft 0 in 0 It 6 in None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 it 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA Egl-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2123.3 116.57 219.22 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 2/14/2020 12:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.6 35 kBlu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS _ / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 364 ft2 Main 91 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabl[e Ceiling Fans: ]Thermosta[[t:]]Y Heat ng [X] Jan [X] Feb [[ j� [X] Mar Apr [X] [X] Jun [ ] Jul r ] Aug [X] [ ] Sep ] l J No' (r)('( Dec Venting I 1 Jan [[ ]) Feb (X7 Mar May Jun I 1 Jul r) Aug I 1 Sep lxl Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM fib 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 6B 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 2/14/2020 12:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1820 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.346 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.269 14. Heating system: Capacity 34.6 c) Area 7c. 239.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF B. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 81b. NA e) Gas furnace, LPG AFUE I) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10, Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) t0A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) t0A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signyture� �Date: Address of New Home: 5361 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951 2/14/2020 12:27:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1