HomeMy WebLinkAboutEnergy CodeFORM-NR405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 16 Block 5 Waterston 1820 CGR
Builder Name: ADAMS HOMES
Street: 5361 San Benedetto Place
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number.
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St.. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2120.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft'
b. Frame - Wood, Adjacent
R=13.0 270.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. NIA
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1820.0 sgfL)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft'
6. Conditioned floor area above grade (ft2) 1820
b. N/A
R= ft2
Conditioned floor area below grade (112) 0
c. N/A
R= ft'
11. Ducts
R ft-
7. Windows(239.3 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 364
a. U-Factor: Dbl, U=0.33 168.74 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.50
c. U-Factor: Dbl, U=0.33 20.42 112
SHGC: SHGC=0.31
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 17.78 ft'
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 4.251 ft.
Area Weighted Average SHGC: 0.269
14. Hot water systems
8. Floor Types (1820.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft'
b. Conservation features
EF: 0.940
b. WA R= ft2
None
c. NIA R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 64.03
PASS
Total Baseline Loads: 68.84
1 hereby certify that the plans and specifications covered b
Review of the plans and
S]glA
this calculation are in complia the Florid y
specifications covered by this
OF•110
_ > O
'Ss
Code.
calculation indicates compliance
.�..
y ,,, _ A
with the Florida Energy Code.
,e,
rnn '•;, :°;• `,`.;;;,�°„ lO
PREPARED BY:
Before construction is completed
=1
DATE: 2-14_917170 Winn Keomany
this building will be Inspected for
compliance with Section 553.908
O >°
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!,),
with the Flodda.Eagrgy Code.
COp Wr' �O
OWNER/AGENT t
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). J
NOSO 0O0
2/14/2020 12:27 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Soft®re Page 1 of 4
1=ORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title'.
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 16 Block 5 Waterston 18 Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: Yes
ADAMS HOMES Rotate Angle: 225
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 16
Block/Subdivision: Waterslone
PlatBook:
Street: 5361 San Benedetto PI
County. St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft' 0.42 0 0.58
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pilch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft' 456 ft- Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft- N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Fmc Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft' 0.11 Wood
2/14/2020 12:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R4O5-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar Below
Spam
P
o
_ 1 NE=>W Exterior Concrete Block - Int Insul Main
4.1 59 0 10
0
590.0 fl2
0
0 0.6
0
-2 SE=>N Exterior Concrete Block - Int Insul Main
4.1 20 0 10
0
200.0 R2
0
0 0.6
0
3 SW=>E Exterior Concrete Block - Int Insul Main
4.1 66 0 10
0
660.0 ft2
0
0 0.6
0
-4 NW=>S Exterior Concrete Block - Int Insul Main
4.1 40 0 10
0
400.0 ft2
0 0.6
0
5 =>S Garage Frame - Wood Main
13 27 0 10
0
270.0 ft2
0
0.23 0.01
0
DOORS
# Omt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated Main
None
.25
3
6 8
20 ft-
2 =>S Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 NE=>W 1 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ft'
1 It 4 in
0 It 10 in
None
Exterior 5
2 NE=>W 1 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 1 O in
None
Exterior 5
3 SE=>N 2 Vinyl Low-E Double Yes
0.33 0.31 N
7.1 ft-
9 it 4 in
0 ft 0 in
None
None
4 SE=>N 2 Vinyl Low-E Double Yes
0.33 0.21 N
16.2 ft2
1 ft 4 in
1 8 0 in
None
None
5 SE=>N 2 Vinyl Low-E Double Yes
0.33 0.21 N
16.2 ft2
1 It 4 in
1 ft 0 in
None
Exterior 5
6 SE=>N 2 Vinyl Low-E Double Yes
0.33 0.31 N
13.3 ft2
9 It 4 in
1 ft 6 in
None
None
7 SW=>E 3 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 fttO in
None
Exteriors
8 NW=>S 4 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
12 it 0 in
0 it 6 in
None
None
9 NW=>S 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 112
1 ft 4 in
0 ft 10 in
None
Exterior 5
10 NW=>S 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
12 ft 0 in
0 It 6 in
None
Exterior 5
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 396 ft2 396 ft2
64 it
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA Egl-A
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000445
2123.3 116.57 219.22
.1685
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5
34.6 kBtu/hr
1
sys#1
2/14/2020 12:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15.6 35 kBlu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
_ / —Supply—
—Return Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft2
Main
91 ft2 Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programabl[e
Ceiling Fans:
]Thermosta[[t:]]Y
Heat ng [X] Jan [X] Feb
[[ j�
[X] Mar
Apr
[X] [X]
Jun [ ] Jul r ] Aug
[X]
[ ] Sep
]
l J
No'
(r)('(
Dec
Venting I 1 Jan [[ ]) Feb
(X7 Mar
May Jun I 1 Jul r) Aug
I 1 Sep
lxl
Oct
[X] Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78 78
78
80
80
80
80
PM
80
80 78
78 78 78 78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78 78
78
78
78
78
78
PM
78
78 78
78 78 78 78
78
78
78
78
78
Heating(WD) AM
fib
66 66
66 66 68 68
68
68
68
68
68
PM
68
68 68
68 68 6B 68
68
68
68
66
66
Heating(WEH) AM
66
66 66
66 66 68 68
68
68
68
68
68
PM
68
68 68
68 68 68 68
68
68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft 0.3
Main
2/14/2020 12:27 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
35.0
a) Split system SEER
15.5
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1820
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.346
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.269
14. Heating system: Capacity
34.6
c) Area
7c.
239.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
B. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
81b.
NA
e) Gas furnace, LPG AFUE
I) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10, Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
t0A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
t0A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 1la. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signyture� �Date:
Address of New Home: 5361 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951
2/14/2020 12:27:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1