Loading...
HomeMy WebLinkAboutNOA 18100116 FWM IAM I -MADE MIAMI-DADE COUNTY • PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.2ov/economy WinDoor, Inc. 7500 Amsterdam Drive Orlando, FL 32832 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami—Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. - DESCRIPTION: Series "238 Designer" Aluminum Fixed Window — L.M.I. APPROVAL DOCUMENT: Drawing No. 18-91D, titled "Series -238 Designer Fixed Window", sheets 1 through 8 of 8, dated 12/27/01, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA and consists of this page 1 and evidence pages E- 1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. r_1 NOA No. 18-1001.16 f10. Expiration Date: October 20, 2023 Approval Date: December 13, 2018 Page 1 WinDoor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No. 96-0603.07 and 09-0303.01) 2. Drawing No. 18-91D, titled "Series -238 Designer Fixed Window", sheets 1 through 8 of 8, dated 12/27/01, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal(b and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No. 15-0512.15) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No. 15-0512.15) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal(t and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No. 15-0512.15) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 Manuel Pe z, P.E. Product Control xa iner NOA No. 18- 01.16 Expiration Date: October 20, 2023 Approval Date: December 13, 2018 E-1 WinDoor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 4. along with marked -up drawings and installation diagram of aluminum fixed windows, prepared by Hurricane Test Laboratory, Inc., Test Report No. HTL-0080-0105-08, dated 01/08/08, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 09-0303.01) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum fixed window, prepared by Hurricane Test Laboratory, Inc., Test Reports No. HTL-0080-0303-96 and HTL-0080-0502-97, dated 03/05/96 and 05/02/97, both signed and sealed by Timothy S. Marshall, P.E. (Submitted under NOA No 96-0603.07) 6. Test reports on: 1) Large Missile Impact Test per SFBC, PA 201-94, 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of aluminum casement, project -out and fixed windows, prepared by American Test Lab of South Florida, Inc., Test Report No. ATLSF-1209.01-94, dated 12/09/94 to 12/14/94, signed and sealed by Gerard B. Sullivan, P.E. (Submitted under NOA No. 96-0603.07) 7. Test reports on: 1) Large Missile Impact Test, per SFBC, PA 202-94 2) Cyclic Wind Pressure Loading, per SFBC, PA 202-94 along with marked -up drawings and installation diagram of an aluminum project -out window, prepared by Fenestration Testing Laboratory, Inc. Report No. FTL-1018, dated 09/26/94, signed and sealed by Yamil Kuri, P.E. (Submitted under NOA No. 96-0603.07) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 51h Edition (2014), dated 07/16/14, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No. 14-0903.07) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). Manuel Pe z, E. Product Control xam' er NOA No. 1 - 1.16 Expiration Date: October 20, 2023 Approval Date: December 13, 2018 E-2 WinDoor, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, of complying with FBC 51h Edition (2014), with FBC 61h Edition (2017) and of no financial interest, dated August 29, 2017, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA # 17-0926.17) 2. Laboratory compliance letters for Test Report No. HTL-0080-0105-08, issued by Hurricane Test Laboratory, Inc., dated 01/08/08, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 09-0303.01) 3. Laboratory compliance letters for Test Reports No. HTL-0080-0303-96 and HTL-0080-0502-97, issued by Hurricane Test Laboratory, Inc., dated 03/05/96 and 05/02/97, both signed and sealed by Timothy S. Marshall, P.E. (Submitted under NOA No. 96-0603.07) 4. Laboratory compliance letters for Test Report No. ATLSF-1209.01-94, issued by American Test Lab of South Florida, Inc., dated 12/09/94 to 12/14/94, signed and sealed by Gerard B. Sullivan, P.E. (Submitted under NOA No. 96-0603.07) 5. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, P.E., Supervisor, Product Control Section. (Submitted under NOA No. 15-0512.15) 6. Private Labeling Agreement document in conformance to Product Control guidelines dated 09/05/18, signed by Dean M. Ruark, P.E. G. OTHERS 1. None. E-3 &1aad 2 6&- - Manuel Pe z, E. Product Controlxami er NOA No. 1 1.16 Expiration Date: October 20, 2023 Approval Date: December 13, 2018 0 5 �a U W C OW EXTERIOR INSTRUCTIONS: USE CHARTS AS FOLLOWS. STEP 1 DETERMINE DESIGN WIND LOAD REQUIREMENT BASED ON WIND VELOCITY, BLDG. HEIGHT, WIND ZONE USING APPLICABLE ASCE 7 STANDARD. STEP 2 SEE CHARTS ON SHEETS 3 THRU 5 FOR DESIGN LOAD CAPACITY OF DESIRED GLASS SIZE BASED ON APPLICABLE WIND DURATION. STEP 3 USING CHART ON SHEET 7 SELECT ANCHOR OPTION WITH DESIGN RATING MORE THAN DESIGN LOAD SPECIFIED IN STEP 1 ABOVE. STEP 4 THE LOWEST VALUE RESULTING FROM STEPS 2 AND 3 SHALL APPLY TO ENTIRE SYSTEM. 0 WINDOW WIDTH 31 0 rn VENT WIDTH z too 00 WW -2" M D.L. OPG. Z z WW -6 1/2- SURFACE APPLIED p` N a 6" MAX. TYP. /" FALSE MUNTINS HEAD/SILL OPTIONAL O 0 0 o CORNERS A W N v ® W VNh p;M 0—m 0 Q, ®® 0egi N N W n LL Lf) W spy 0 fit=--- ^ Q Z 0 2 M O I W W h —I I II 3 ----7I-----11 _--- 39-1 ci°o 1 00 LO II tl I I z co II II uW 0 it X !L of Q)> W c �L z C B 17" MAX. N TYP. o Ci C'4 E 000 C i T i TYPICAL ELEVATION N i U) LL - C -4 O a Li o oc WC O 0 vwi r- o 1 B OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON—COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. THESE WINDOWS ARE RATED FOR LARGE MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. proroVed 88 COMplyifig r itb tk '`019@OBMMpip®® gGENSIS� ` qQ 0 c v a� c 0 0 0 Q c s 1 n N N � drawing no. 18-91 D sheet 1 of 8 MITERED COPED 90° CORNERS ONLY VENT CORNER ALL FRAME AND VENT CORNERS TO BE SEALED WITH GE SILPRUF OR EQUIV. -11 — I-M.iroc MITERED COPED 90' CORNERS ONLY FRAME CORNER ITEM PART # QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS 1 CGI -386 4 FRAME 6063—T6 INDALEX OR EQUIV. 2 CGI -387 4 VENT 6063—T6 INDALEX OR EQUIV. 2A CGI -3871G 4 VENT (INSUL GLASS) 6063—T6 INDALEX OR EQUIV. 3 CGI— 4 GLAZING BEAD 6063—T5 INDALEX OR EQUIV. 4 — AS REQD. GLAZING BEAD SCREWS ® 6" FROM ENDS & 20" O.C. MAX. — #12 X 5/8" SMS 5 — — GLAZING COMPOUND SILICONE GE -1000 ( NON—IMPACT ) 5A — — GLAZING COMPOUND SILICONE GE -1200 ( IMPACT ) 6 — 4 1/2" X .090" SINGLE FACED GLAZING TAPE FOAM — 7 Q200 X190 AS REQD. VENT WEATHERSTRIPPING — SCHLEGEL Q—LON — AS REQD. VENT SCREWS ® 17" O.C. TYP. — #10 X 1" SS SMS E108 — 2/ CORNER FRAME AND VENT ASSEMBLY SCREWS — #10 X 1-1/4" SS SMS — 2/ LITE SETTING BLOCK EPDM I DUROMETER 80±5 SHORE A PARTIAL CIRCLE TUMBSTONE WINDOW WIDTH ARCH TOP x z J 0 0 z z Li J 3.0 0 z 3 z W J 0 0 z 3 WINDOW WIDTH SQUARE OR RECTANGLE _ WINDOW WIDTH _ WINDOW WIDTH � WINDOW WIDTH OCTAGON HEXAGON TRAPEZOID PENTAGON I I I I = WINDOW LENGTH C.9 P - J ELLIPSE J I I 3: 1 00 z I I � 1 I I I L----- -----JI W WINDOW WIDTH VERIFY LOAD CAPACITY OF WINDOW BY INSCRIBING SHAPE OF WINDOW WITHIN A RECTANGULAR OR SQUARE SHAPE AND USING THOSE DIMENSIONS TO CONSULT CHARTS ON SHEETS 3, 4 & 5 FOR GLASS AND SHEET 7 FOR ANCHORS AS ON SAMPLE ABOVE. WINDOW WIDTH WINDOW LENGTH FULL CIRCLE HALF CIRCLE c� z J 0 0 z 3 0 0 app4'tve€9 to carmla6d rm wift 2.085 .100 Typ. TYP. .835 1.510 II 1.500 Q 798 I - FRAME 2.215- m 1.625— VENT .625—VENT 3 I 0 Y rn po olo ►� co cp Z L N al a 1.625 Od ®QQ O 625 ujN ® H U. �Nm 0 a a r°+ NNS Y.160 LL, j LL LL, 0 LL a z O M (Z-1 'D t0 875 OLO (O 750 0 IO 00 w o x L.L. X o' > LA.I L z 0 N 0 n 60 00 C) U �n i L I 0z) J ro in LL 00 N L E ._ 0 Q O � 5 LJ 0 O c E c: 0 C) LLJ c r- 0 0 FT VENT (INSUL GLASS) 1.750 r .750 19�_. 12 GLAZING STOP ®®®10966B6p®®®® ® a ° p 24,20180 ® 0 ° STATE OF �9® ZORID ®®® IO o 'E c 0 L U C ,, O O C 0 1 II N e cy N N � Fa- d drawing no. 18-91 D sheet 2 of $ PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '2' GLASS TYPE '3' WIDTH HEIGHT EXT. (+) 1 NT. (-) EXT. (+) 1 NT. (-) 24" 30" 36" 42" 48" 54" 60" 36" 110.0 180.0 110.0 180.0 110.0 144.0 110.0 144.0 110.0 120.0 110.0 120.0 110.0 120.0 110.0 120.0 101.4 101.4 110.0 120.0 84.8 84.8 110.0 120.0 74.7 74.7 110.0 114.3 24" 30" 36" 42" 48" 54" 60" 42" 110.0 166.4 110.0 168.0 110.0 142.5 110.0 144.0 110.0 120.0 110.0 120.0 102.9 102.9 102.9 102.9 85.0 85.0 102.9 102.9 75.1 75.1 102.9 102.9 66.4 66.4 90.0 90.0 24" 30" 36" 42" 48" 54" 60" 48" 1 110.0 153.1 110.0 160.0 110.0 117.6 110.0 120.0 101.4 101.4 110.0 120.0 85.0 85.0 102.9 102.9 75.5 75.5 90.0 90.0 68.4 68.4 90.0 90.0 63.6 63.6 1 90.0 90.0 24" 30" 36" 42" 48" 54" 60" 54" 110.0 134.8 110.0 154.3 99.4 99.4 110.0 120.0 84.8 84.8 110.0 120.0 75.1 75.1 102.9 102.9 68.4 68.4 90.0 90.0 65.8 65.8 80.0 80.0 59.0 59.0 80.0 80.0 24" 30" 36" 42" 48" 54" 60" 110.0 119.4 110.0 120.0 87.8 87.8 110.0 120.0 74.7 74.7 110.0 114.3 66.4 66.4 90.0 90.0 63.6 63.6 90.0 90.0 59.0 59.0 80.0 80.0 24" 30" 36" 42" 48" 66 110.0 112.5 110.0 120.0 82.1 82.1 110.0 120.0 66.6 66.6 90.0 90.0 58.1 58.1 90.0 90.0 56.1 56.1 90.0 90.0 24" 30" 36" 42" 48" 72" 105.4 105.4 110.0 120.0 74.0 74.0 110.0 120.0 59.2 59.2 90.0 90.0 51.2 51.2 90.0 90.0 49.8 49.8 83.9 83.9 PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '2' GLASS TYPE '3' WIDTH HEIGHT EXT. (+) 1 NT. (-) EXT. (+) 1 NT. (-) 24" 30" 36" 42" 78„ 97.5 97.5 110.0 120.0 67.2 67.2 90.0 90.0 50.8 50.8 90.0 90.0 46.1 46.1 86.1 86.1 24" 30" 36" 84" 103.0 103.0 110.0 120.0 63.0 63.0 90.0 90.0 47.3 47.3 90.0 90.0 24" 30" 36" 96" 87.5 87.5 110.0 120.0 56.3 56.3 90.0 90.0 41.6 41.6 90.0 90.0 24" 30" 108„ 69.6 69.6 90.0 90.0 53.5 53.5 90.0 90.0 24" 120" 58.8 58.8 90.0 90.0 WINDOW LENGTH WD. WIDTH NOTE: WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN. 1/8" ANN. GLASS 090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' OR .090" Interlayer Trosifol PVB a By 'Kuraray America, Inc.' �7- Lj z M 1 /8" ANN. GLASS W GE -1200 I SILICONE AT 1/4 POINTS ON LITES 10 WIDER THAN 36" 5/16" NOMINAL GLASS TYPE '2' NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '2' GLASS TYPE '3' WIDTH HEIGHT EXT. (+) 1 NT. (-) EXT. (+) 1 NT. (-) 19-1/8" 26-1/2" 37" 53-1/8" 26" 110.0 210.0 110.0 210.0 110.0 166.2 110.0 166.2 110.0 166.2 110.0 166.2 110.0 120.0 110.0 120.0 19-1/8" 26-1/2" 37" 53-1/8" 38-3/8" 110.0 200.6 110.0 200.6 110.0 163.0 110.0 163.0 110.0 116.8 110.0 116.8 81.9 81.9 110.0 112.6 19-1/8" 26-1/2" 37" 53-1/8" 50-5/8" 110.0 185.7 110.0 185.7 110.0 1 125.2 110.0 147.2 92.1 92.1 110.0 116.8 66.6 66.6 85.3 85.3 19-1/8" 26-1/2- 37" 53-1/8" 1 63' 110.0 177.5 110.0 177.5 98.1 98.1 110.0 120.0 68.6 68.6 110.0 110.2 56.6 56.6 1 81.3 81.3 19-1/8" 26-1/2" 37" 74-1/4" 110.0 .0 120.0 85.2 .0 L55.4L910.0 120.0 55.4 90.0 3/16" ANN. GLASS .090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' OR .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 3/16" ANN. GLASS GE -1200 SILICONE AT 1/4 POINTS ON LITES WIDER THAN 36" 7/16" NOMINAL GLASS TYPE '3' �I p� Q�4a®®' 3 I 0 rn 00 010 ®z "'N z i®111�� d � to j ® O W N U ®1 VNh 0>M o �®® q rr: ON W=� 6 W N - o Z c+y ZM2 w Ww r sheet 3 of 8 O � � Z_ I 0 W X o L- W Z 0 N C� r� E 00 o 0 �M ro C i C 00 I �� J M N to LL- 00 L: E Q O U) LU O 0 0 C of C 0 0 " Lj Lr) sheet 3 of 8 PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '6' WIDTH HEIGHT EXT. (+) 1 NT. (-) 24" 30" 36" 42" 48" 54" 60" 36" 110.0 195.8 110.0 156.6 110.0 130.5 110.0 120.0 110.0 120.0 110.0 120.0 110.0 120.0 24" 30" 36" 42" 48" 54" 60" 42" 110.0 193.6 110.0 156.6 110.0 120.0 96.9 111.9 96.9 111.9 96.9 111.9 90.0 90.0 24" 30" 36" 42" 48" 54" 60" 48" 110.0 184.4 110.0 120.0 110.0 120.0 96.9 111.9 84.8 97.9 90.0 90.0 90.0 90.0 24" 30" 36" 42" 48" 54" 60" 54 1 110.0 177.8 110.0 120.0 110.0 120.0 96.9 111.9 90.0 90.0 80.0 80.0 80.0 80.0 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" g1" 84" 87" 60„ 110.0 120.0 110.0 120.0 110.0 120.0 90.0 90.0 90.0 90.0 80.0 80.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 1 50.0 PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '6' WIDTH HEIGHT EXT. (+) 1 NT. (-) 24" 30" 36" 42" 48" 54" 57" 60" 63" 66" 69" 72" 75" 78" 81 " 84" 87" 66" 110.0 120.0 110.0 120.0 90.0 90.0 90.0 90.0 90.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 68.6 68.6 65.5 65.5 65.5 65.5 65.5 65.5 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 24" 30" 36" 42" 48" 51" 54" 57" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 72" 110.0 120.0 110.0 120.0 90.0 90.0 90.0 90.0 90.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 68.6 68.6 65.5 65.5 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 24" 30" 36" 42" 45" 48" 51" 54" 57" 60" 63" 66" 69" 72" 75" 78" 81 " 1 78" 110.0 120.0 90.0 90.0 90.0 90.0 90.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '6' WIDTH HEIGHT EXT. (+) 1 NT. (-) 24" 30" 36" 42" 45" 48" 51" 54" 57" 60" 63" 66" 69" 72" 75" 84" 110.0 120.0 90.0 90.0 90.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 24" 30" 36" 39" 42" 45" 48" 51" 54" 57" 60" 63" 66" 96" 1 110.0 120.0 90.0 90.0 90.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 24" 30" 33" 36" 39" 42" 45" 48" 51" 54" 57" 60" 108" 90.0 90.0 90.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 24" 30" 33" 36" 39" 42" 45" 48" 51" 54" 120" 90.0 90.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '6' WIDTH HEIGHT EXT. (+) 1 NT. (-) 24" 30" 33" 36" 39" 42" 45" 48" 132" 70.0 70.0 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 24" 30" 33" 36" 39" 42" 45" 144" 70.0 70.0 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 24" 30" 33" 36" 39" 156" 70.0 70.0 70.0 70.0 50.0 50.0 50.0 50.0 50.0 50.0 WINDOW LENGTH WI x z J O NOTE: WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN. NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) IF- PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 5 AND 6 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '6' WIDTH HEIGHT EXT. (+) 1 NT. (-) 19-1/8" 26-1/2" 37" 53-1/8- 26" 110.0 210.0 110.0 180.7 110.0 180.7 110.0 120.0 19-1/8" 26-1/2- 37" 53-1/8" 38-3/8" 110.0 210.0 110.0 177.3 110.0 120.0 110.0 120.0 19-1/8" 26-1/2" 37" 53-1/8" 50-5/8" 110.0 210.0 110.0 169.7 110.0 120.0 85.3 85.3 19-1/8" 26-1/2" 37" 53-1/8" 63" 110.0 204.6 110.0 120.0 110.0 120.0 81.3 81.3 19-1/8" 26-1/2- 37" 53-1/8- 74-1/4" 110.0 120.0 110.0 120.0 90.0 90.0 70.0 70.0 16" HEAT STREN'D GLASS .090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' OR .090" Interlayer Trosifol PVB By 'Kuroroy America, Inc.' 3/16" HEAT STREN'D GLASS GE -1200 SILICONE AT 1/4 POINTS ON LITES 10 WIDER THAN 36" 7/16" NOMINAL GLASS TYPE '6' Q��a®®° OE��� o.70592 0 - o p 24,2018® STATE OR X190 �QO(RID ®�,0090C1@8®® 3 I a m 00 W N I ILn- OO�V. C M W M 0 N ®w Ugh ® uj ri 0>M o A O W = � 1L, N- o Z M r w(� F 3:� O Ln ZIZIu� i W o X L.� W L z D N 9 n D U C,p rN 00 00 �� J n u) LL- 00 cV L E v1 0 -0 LL.I C) O �C O v vwi 3 r- o I sheet 4 of 8 1 PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '2A' GLASS TYPE '3A' WIDTH HEIGHT EXT. (+) 1 NT. (-) EXT. (+) 1 NT. (-) 24" 30" 36" 42" 48" 54" 60" 36" 1 110.0 180.0 110.0 195.8 110.0 144.0 110.0 156.6 110.0 120.0 110.0 130.5 110.0 120.0 110.0 120.0 107.7 107.7 110.0 120.0 90.1 90.1 110.0 120.0 79.3 79.3 110.0 120.0 24" 30" 36" 42" 48" 54" 60" 42" 1 110.0 168.0 110.0 193.6 110.0 144.0 110.0 156.6 110.0 120.0 110.0 120.0 102.9 102.9 96.9 111.9 90.3 90.3 96.9 111.9 79.8 79.8 96.9 111.9 70.5 70.5 90.0 90.0 24" 30" 36" 42" 48" 54" 60" 48" 110.0 160.0 110.0 184.4 110.0 120.0 110.0 120.0 107.7 107.7 110.0 120.0 90.3 90.3 96.9 111.9 80.2 80.2 84.8 97.9 72.7 72.7 90.0 90.0 67.6 67.6 90.0 90.0 24" 30" 36" 42" 48" 54" 60" 54" 1 110.0 143.3 110.0 177.8 105.6 105.6 110.0 120.0 90.1 90.1 110.0 120.0 79.8 79.8 96.9 111.9 72.7 72.7 90.0 90.0 69.9 69.9 80.0 80.0 62.7 62.7 80.0 80.0 24" 30" 36" 42" 48" 54" 60" 110.0 120.0 110.0 120.0 93.3 93.3 110.0 120.0 79.3 79.3 110.0 120.0 70.5 70.5 90.0 90.0 67.6 67.6 90.0 90.0 62.7 62.7 80.0 80.0 24" 30" 36" 42" 48" 66" 110.0 119.5 110.0 120.0 87.2 87.2 110.0 120.0 70.7 70.7 90.0 90.0 61.7 61.7 90.0 90.0 59.6 59.6 90.0 90.0 24" 30" 36" 42" 48" 72" 110.0 1 1 1.9 110.0 120.0 78.6 78.6 110.0 120.0 62.9 62.9 90.0 90.0 54.4 54.4 90.0 90.0 1 52.9 1 52.9 90.0 1 90.0 PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '2A' GLASS TYPE '3A' WIDTH HEIGHT EXT. (+) 1 NT. (-) EXT. (+) 1 NT. (-) 24" 30" 36" 42" 78„ 103.6 103.6 110.0 120.0 71.4 71.4 90.0 90.0 54.0 54.0 90.0 90.0 48.9 48.9 90.0 90.0 24" 30" 36" 84" 109.4 109.4 110.0 120.0 67.0 67.0 90.0 90.0 50.2 50.2 90.0 90.0 24" 30" 36" 96" 92.9 92.9 110.0 120.0 59.8 90.0 90.0 [59J8 44.2 44.2 90.0 90.0 24" 30" 108" 74.0 74.0 90.0 90.0 56.8 56.8 90.0 90.0 24" 120" 62.5 62.5 90.0 1 90.0 wnw WIDTH WINDOW LENGTH NOTE: WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE. 25. PERFORMANCE VALUES OF IMPACT RESISTANT WINDOWS NO SHUTTERS REQUIRED REFER TO SHEETS 6 AND 7 FOR INSTALLATION DETAILS WINDOW DIMS. GLASS TYPE '2A' GLASS TYPE '3A' WIDTH HEIGHT EXT. (+) 1 NT. (-) EXT. (+) 1 NT. (-) 19-1/8" 26-1/2" 37" 53-1/8" 26 110.0 210.0 110.0 210.0 110.0 166.2 110.0 180.7 110.0 166.2 110.0 180.7 1 110.0 120.0 110.0 1 120.0 19-1/8- 26-1/2- 37" 53-1/8" 38-3/8" 110.0 200.6 110.0 210.0 110.0 163.0 110.0 177.3 110.0 116.8 110.0 120.0 87.0 87.0 110.0 120.0 19-1/8- 26-1/2- 37" 53-1/8" 1 50-5/8" 110.0 185.7 110.0 210.0 110.0 133.0 110.0 169.7 97.9 1 97.9 110.0 120.0 70.8 70.8 85.3 85.3 19-1/8" 26-1/2" 37" 53-1/8- 63" 1 110.0 177.5 110.0 204.6 104.3 104.3 110.0 120.0 72.9 72.9 110.0 120.0 60.1 60.1 81.3 81.3 19-1/8" 26-1/2- 37" 1 74-1/4" 110.0 120.0 110.0 120.0 90.5 90.5 110.0 120.0 58.8 1 58.8 90.0 90.0 1/8" TEMP. GLASS�1/8" TEMP. GLASS X1/8" ANN. GLASS X1/8" TEMP. GLASS 090" Interlayer 090" Interlayer Saflex Clear And Color Glass Saflex Clear And Color Glass By' Chemical Co.' By 'Eastman Chemical Co.' OR OR .090" Interlayer .090" Interlayer Trosifol PVB Trosifol PVB w By 'Kuraroy America, Inc.' a W By 'Kuraray America, Inc.' uj Fn m N 1/8" ANN. GLASS U) 1/8" TEMP. GLASS GE -1200 GE -1200 SILICONE i i i i i j SILICONE XL EDGE SPACER XL EDGE SPACER ST. STEEL BY 'CARDINAL' ST. STEEL BY 'CARDINAL' OR 10 AT 1 /4 POINTS ALL SIZES OR 10 AT 1/4 POINTS ALL SIZES DURASEAL BY 'QUANEX' DURASEAL BY 'QUANEX' OR OR SUPER SPACER BY 'QUANEX' 3/4" INSULATED SUPER SPACER BY 'QUANEX' 3/4" INSULATED GLASS TYPE '2A' GLASS TYPE '3A' ®0®,e�cloaoiea® N 19i so e Mo, 705`2 g ep 24,2018 STATE O NOTE: ZORID OF �9® GLASS CAPACITIES ON THIS SHEET ARE Q� �J�®® BASED ON ASTM E1300-09 (3 SEC. GUSTS) s ®®®®®/O�\oo I1I\ D I 0 rn CD 00 0 -0Z "' 9 Z W 1 JL a ®® ,0 O N U ®W U0M of ®>M o JX ®® O w�LL w N p Z O aW_B � ww i" O 0 Ln, _Z 1 a LLJ 0 X a; w •� Z 0 N 0 V C 001 00 J n w N L E _ V) 0< 0-0 j w 0 0 C y -C O 0 cavil 3r-09 c 0 U w C (D o a 0) 0 C s r 11 0 N N � N � H a N U drawing no. 18-91 D sheet 5 of 8 1/4" ULTRACON SEALANT INSTALLATION TYPE '1' INSTALLATION CONDITIONS (APPLIES TO ALL FOUP, SIDES) FOR ANCHOR PERFORMANCE VALUES SEE SHEET 6 1 3/8" M WOOD BUCK TYPE '1' MATERIAL: PRESSURE TREATED TYPICAL INSTALLATION DETAIL ON ALL FOUR SIDES/USING WOOD 1/4" ULTRACONS 1-1/2" EMBED SEALANT 1 3/8" ° ° vQ a ° BUCK INSTALLATION BY OTHERS 1" MIN. INSTALLATION TYPE '3' WOOD BUCK TYPE '3' MATERIA : PRESSURE TREATED TYPICAL INSTALLATION DETAIL ON ALL FOUR SIDES/USING WOOD SEAL n /A 111 -A-Ki INSTALLATION TYPE '2' d- M 2 1/8" MIN. WOOD BUCK TYPE '2' MATERIAL: PRESSURE TREATED TYPICAL INSTALLATION DETAIL ON ALL FOUR SIDES/USING WOOD 1/4" ULTRACONS 1-1/2" EMBED SEALANT 1" MIN. X N S ° BUCK INSTALLATION BY OTHERS INSTALLATION TYPE '4' "vela WOOD BUCK TYPE '4' MATERIAL: PRESSURE TREATED TYPICAL INSTALLATION DETAIL ON ALL FOUR SIDES/USING WOOD WOOD BUCKS NOT BY WINDOOR INC., MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS SEE ELEV. FOR SPACING METAL STRUCTURES ATTACHMENT TO METAL STRUCTURES ATTACHMENT TO APPROVED MULLIONS ®®� ®r�N�i� T ST,4TE «JF I 0 rn alo 0 Z w N a OO�v WN M O ®� LL UNm Lj T4 cf ®'M o IL r O N W Z LL �^ w (� o i ZOO M wm� r O L0 0 LO Z � r W o o' > �° w Z 0 (V 0 n W E COCl'0 o a V� C i I 00 a� wLI- E _ V) 0 Q w Cl >` O a cWn o ( sheet 6 of 8 ) PERFORMANCE VALUES OF INSTALLATION ANCHORS REFER TO SHEET 6 FOR DETAILS WINDOW DIMS. EXT. (+) INT. (-) WIDTH HEIGHT 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 36" 210.0 210.0 210.0 210.0 210.0 210.0 190.5 177.8 208.3 196.1 185.2 175.4 166.7 190.5 181.8 173.9 166.7 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 42" 210.0 210.0 210.0 210.0 210.0 207.8 175.8 163.3 190.5 178.6 168.1 158.7 150.4 171.4 163.3 155.8 149.1 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 48" 210.0 210.0 210.0 210.0 210.0 200.0 166.7 153.8 178.6 166.7 156.3 147.1 138.9 157.9 150.0 142.9 136.4 PERFORMANCE VALUES OF INSTALLATION ANCHORS REFER TO SHEET 6 FOR DETAILS WINDOW DIMS. EXT. (+) INT. (-) WIDTH HEIGHT 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 54" 210.0 210.0 210.0 207.8 200.0 197.5 161.6 148.1 170.9 158.7 148.1 138.9 130.7 148.1 140.4 133.3 127.0 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 60" 210.0 210.0 190.5 175.8 166.7 161.6 160.0 145.5 160.0 153.8 142.9 133.3 125.0 141.2 133.3 126.3 120.0 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" g0" 66" 210.0 210.0 208.3 190.5 178.6 170.9 160.0 145.1 165.3 151.5 139.9 129.9 121.2 136.4 128.3 121.2 114.8 PERFORMANCE VALUES OF INSTALLATION ANCHORS REFER TO SHEET 6 FOR DETAILS WINDOW DIMS. EXT. (+) INT. (-) WIDTH HEIGHT 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 72" 210.0 210.0 185.2 168.1 156.3 148.1 142.9 141.1 139.9 139.1 138.9 128.2 119.0 133.3 125.0 117.6 111.1 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 78" 210.0 190.5 166.7 150.4 138.9 130.7 125.0 122.9 121.2 119.9 119.0 118.5 118.3 118.3 118.3 115.4 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81- 84" 210.0 208.7 181.8 163.3 150.0 140.4 133.3 130.6 128.3 126.5 125.0 123.9 118.3 122.6 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 96" 210.0 177.8 153.8 137.1 125.0 115.9 109.1 106.3 103.9 101.8 100.0 PERFORMANCE VALUES OF INSTALLATION ANCHORS REFER TO SHEET 6 FOR DETAILS WINDOW DIMS. EXT. (+) INT. (-) WIDTH HEIGHT 24" 30" 36" 42" 48" 54" 60" 63" 108" 210.0 180.6 155.6 137.9 125.0 115.2 107.7 104.6 24" 30" 36" 42" 48" 54" 120" 210.0 182.9 156.9 138.5 125.0 114.7 24" 30" 36" 42" 48" 132" 210.0 184.6 157.9 139.0 125.0 24" 30" 36" 42" 48" 144" 204.5 167.4 142.9 125.4 112.5 24" 30" 36" 42" 156" 208.3 170.2 144.9 127.0 PERFORMANCE VALUES OF INSTALLATION ANCHORS REFER TO SHEET 6 FOR DETAILS WINDOW DIMS. EXT. (+) INT. (-) WIDTH HEIGHT 19-1/8- 26-1/2" 37" 53-1/8" 26" 210.0 210.0 210.0 210.0 19-1/8- 26-1/2" 37" 53-1/8- 38-3/8" 210.0 210.0 210.0 210.0 19-1/8. 26-1/2" 37" 53-1/8" 50-5/8" 210.0 210.0 210.0 204.5 19-1/8" 26-1/2" 37" 53-1/8" 63„ 210.0 210.0 174.9 148.8 19-1/8- 26-1/2" 37" 53-1/8" 74-1/4" 210.0 210.0 174.5 142.1 WDW. WIDTH W DOW _IN LENGTH J o NOTE: WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE. 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD THRU 1BY BUCKS INTO CONC. OR MASONRY 1-1/4" MIN. EMBED INTO CONC. OR MASONRY DIRECTLY INTO CONC. OR MASONRY 1-1/4" MIN. EMBED INTO CONC. OR MASONRY #14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO METAL STRUCTURES STEEL : 12 GA. MIN. (Fy = 36 KSI MIN.) ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) #12 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO MIAMI-DADE COUNTY APPROVED MULLIONS (MIN. THK. = 1/8") (NO SHIM SPACE) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. ®epppVOtl9B0//®® ® OOEN�� o.70592 k o p 24,20180® STATE OFzomv �9® 3 I 0 o) z CO 010 Z M Z W � 2 (D Q d LO o 0 0 0 O W N U ®� LL 1UN� 0 m o �Ir 0 0® tON0 m Z ® N W :3W L0 Wy -0 ww� I_ O LO D 'n Z I 0 0 Li 0 X LL_ X Of > bi ZE CO D N C7 M 00 00 a� J V) toLL cO E . '1:'U)0 Q w �o�0 L1 (n r O (sheet 7 of 8 ) PERFORMANCE VALUES OF ALUMINUM BUCK INSTALLATION ANCHORS WINDOW DIMS. ANCHORS ANCHORS AT 17" O.C. AT 10" O.C. WIDTH HEIGHT EXT. (+) EXT. (+) INT. (-) INT. (-) 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 36" 207.8 210.0 189.9 210.0 184.7 210.0 138.5 184.7 147.7 184.7 123.1 184.7 105.5 158.3 98.5 172.4 115.4 161.6 108.6 152.1 102.6 143.6 97.2 155.5 92.3 147.7 105.5 140.7 100.7 151.1 96.3 144.5 92.3 138.5 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 42" 166.2 210.0 147.7 197.0 138.5 184.7 135.7 180.9 135.7 175.9 115.1 172.7 97.4 146.1 90.4 158.3 105.5 147.7 98.9 138.5 93.1 130.4 87.9 140.7 83.3 133.3 95.0 126.6 90.4 135.7 86.3 129.5 82.6 123.9 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 48" 184.7 210.0 161.2 201.5 147.7 184.7 135.7 175.9 138.5 173.1 110.8 166.2 92.3 138.5 85.2 149.2 98.9 138.5 92.3 129.3 86.6 121.2 81.5 130.4 76.9 123.1 87.5 116.6 83.1 124.7 79.1 118.7 75.5 113.3 PERFORMANCE VALUES OF ALUMINUM BUCK INSTALLATI ON ANCHORS WINDOW DIMS. ANCHORS ANCHORS AT 17" O.C. AT 10" O.C. WIDTH HEIGHT EXT. (+) EXT. (+) INT. (-) INT. (-) 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 54" 158.3 210.0 136.4 204.6 123.1 184.7 115.1 172.7 110.8 166.2 109.4 164.1 89.5 134.3 82.1 143.6 94.7 132.6 87.9 123.1 82.1 114.9 76.9 123.1 72.4 115.9 82.1 109.4 77.8 116.6 73.9 110.8 70.3 105.5 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 60" 138.5 207.8 118.2 177.3 105.5 158.3 97.4 146.1 92.3 138.5 89.5 134.3 88.6 133.0 80.6 133.0 88.6 129.3 85.2 119.3 79.1 110.8 73.9 118.2 69.3 110.8 78.2 104.3 73.9 110.8 70.0 105.0 66.5 99.7 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 66" 153.9 210.0 130.4 182.5 115.4 1 161.6 105.5 147.7 98.9 138.5 94.7 132.6 88.6 129.3 80.4 128.5 91.6 128.2 83.9 117.5 77.5 108.5 71.9 115.1 67.2 107.4 75.5 100.7 71.1 106.7 67.2 100.7 63.6 95.4 PERFORMANCE VALUES OF ALUMINUM BUCK INSTALLATI ON ANCHORS WINDOW DIMS. ANCHORS ANCHORS AT 17" O.C. AT 10" O.C. WIDTH HEIGHT EXT. (+) EXT. (+) IM, (-) INT. (-) 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 90" 72" 138.5 193.9 116.6 163.3 102.6 143.6 93.1 130.4 86.6 121.2 82.1 114.9 79.1 110.8 78.2 109.4 77.5 108.5 77.1 107.9 76.9 107.7 71.0 107.7 66.0 105.5 73.9 98.5 69.3 103.9 65.2 97.8 61.6 92.3 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 87" 78" 125.9 201.5 105.5 168.8 92.3 147.7 83.3 133.3 76.9 123.1 72.4 115.9 69.3 110.8 68.1 108.9 67.2 107.4 66.4 106.3 66.0 105.5 65.7 105.1 65.6 104.9 65.6 97.4 65.6 102.3 63.9 95.9 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 75" 78" 81" 84" 138.5 207.8 115.6 173.4 100.7 151.1 90.4 135.7 83.1 124.7 77.8 116.6 73.9 110.8 72.4 108.5 71.1 106.7 70.1 105.1 69.3 103.9 68.6 102.9 65.6 102.3 67.9 97.3 24" 30" 36" 42" 48" 54" 60" 63" 66" 69" 72" 96" 118.7 197.9 98.5 164.1 85.2 142.1 76.0 126.6 115.4 107.1 E60.4100.7 98.2 57.6 95.9 56.4 94.0 55.4 92.3 PERFORMANCE VALUES OF ALUMINUM BUCK INSTALLATI ON ANCHORS WINDOW DIMS. ANCHORS ANCHORS AT 17" O.C. AT 10" O.C. WIDTH HEIGHT EXT. (+) EXT. (+) INT. (-) INT. (-) 24" 30" 36" 42" 48" 54" 60" 63" 108" 121.2 190.4 100.1 157.3 86.2 135.4 76.4 120.1 69.3 108.8 63.8 100.3 59.7 93.8 57.9 91.0 24" 30" 36" 42" 48" 54" 120" 123.1 184.7 101.3 152.0 86.9 130.4 76.7 115.1 69.3 103.9 63.5 95.3 24" 30" 36" 42" 48" 132" 124.7 180.1 102.3 147.7 87.5 126.4 77.0 111.2 69.3 100.0 24" 30" 36" 42" 48" 144" 113.3 188.9 92.8 154.6 79.1 131.9 69.5 115.8 62.3 103.9 24" 30" 36" 42" 156" 115.4 184.7 94.3 150.9 80.3 128.5 70.3 112.6 PERFORMANCE VALUES OF ALUMINUM BUCK INSTALLATION ANCHORS WINDOW DIMS. ANCHORS ANCHORS AT 17" O.C. AT 10" O.C. WIDTH HEIGHT EXT. (+) EXT. (+) INT, (-) INT. (-) 19-1/8" 26-1/2" 37" 53-1/8- 26" 210.0 210.0 210.0 210.0 191.8 210.0 152.9 210.0 19-1/8" 26-1/2" 37" 53-1/8" 38-3/8" 210.0 210.0 179.7 210.0 162.7 210.0 122.5 183.8 19-1/8" 26-1/2" 37" 53-1/8" 50-5/8" 203.2 210.0 161.1 201.4 134.2 167.8 113.3 155.6 19-1/8- 26-1/2" 37" 53-1/8. 63" 156.1 210.0 121.0 210.0 96.9 169.6 82.4 144.2 19-1/8" 26-1/2" 37" 53-1 /8" 74-1/4" 161.2 210.0 123.4 197.4 96.7 154.7 78.7 126.0 ALUMINUM DUCK FRAMING DE'T'AILS REFER TO SHEETS 3 THRU 6 FOR WINDOW CAPACITIES USE LOWER APPLICABLE VALUES. 2.500 .845 845 .065 .065 �92 T .562 1.125 1.4 36. 125 .903 ALUMINUM BUCK OPTIONAL COVER 6063-T6 6063-T6 #14 SMS AT 6" FROM ENDS 17" O.C. MAX. AT HEAD/SILL/JAMB X tV N d . d C U 4.a .2 1/2" AIIN EDGE DIST: a 1,Y4 DIA, ULTRACON 1,+1/4" MIN. CONC. EMBED AT 6" FROM ENDS SEE CHART FOR SPACING INSTALLATION TYPE '5' AT HEAD/SILL/JAMB 1" MIN. INSTALLATION TYPE '6' 2BY WOOD BUCK OR WOOD STRUCTURES O a , , iY Wk. Pwaing CO b� N TYPICAL INSTALLATION DETA L ON ALL FOUR SIDES/USING ALUMINUM BUCK SYSTEM 1/4" DIA. ULTRACON 1-1/4" MIN. CONC. EMBED AT 6" FROM ENDS SEE CHART FOR SPACING AT HEAD/SILL/JAMB ®®ppppBBOBO//A® pq Q��a®®®® 0 3 :(c 1:11 I 0 rn ro ko O Z 65 w 0 0 0 O w U ®H V =) m ® ui c-1 cf ® > M O ®� U) (1) cV w LL w to - O ZM� w Lu 01 O Ln � I 00 _Z 0 r W �o X ._. LL - X > W 'L Z N CD r� 00 p Up rN C L I v CO - N L 00 N i E _ 0a�o W no s d; W �O co § I` O (sheet 8 of 8 1 #14 SMS AT 6" FROM ENDS 17" O.C. MAX. c AT HEAD/SILL/JAMB N X \ N 1" MIN. INSTALLATION TYPE '6' 2BY WOOD BUCK OR WOOD STRUCTURES O a , , iY Wk. Pwaing CO b� N TYPICAL INSTALLATION DETA L ON ALL FOUR SIDES/USING ALUMINUM BUCK SYSTEM 1/4" DIA. ULTRACON 1-1/4" MIN. CONC. EMBED AT 6" FROM ENDS SEE CHART FOR SPACING AT HEAD/SILL/JAMB ®®ppppBBOBO//A® pq Q��a®®®® 0 3 :(c 1:11 I 0 rn ro ko O Z 65 w 0 0 0 O w U ®H V =) m ® ui c-1 cf ® > M O ®� U) (1) cV w LL w to - O ZM� w Lu 01 O Ln � I 00 _Z 0 r W �o X ._. LL - X > W 'L Z N CD r� 00 p Up rN C L I v CO - N L 00 N i E _ 0a�o W no s d; W �O co § I` O (sheet 8 of 8 1