Loading...
HomeMy WebLinkAboutFS-1616-FEMA-Flood-Vent-InfoIMES Evaluation Report ESR-3760 Reissued March 2016 This report is subject to renewal March 2018. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: --FLOOD SOLUTIONS-, LLC­------- ONE INDUSTRIAL PARK DRIVE BUILDING 27 PELHAM, NEW HAMPSHIRE 03076 (800)325-9775 www.floodsolutions.com InfoW oodsolutions.com EVALUATION SUBJECT: STATIC FLOOD VENTS 1.0 EVALUATION SCOPE Compliance with the following codes; it 2015, 2012 and 2009 International Building Codee ■ 2015, 2012 and 2009 International Residential Codes Property evaluated: Water flow 20 USES Flood Solutions' static flood vents are used to provide for the equalization of hydrostatic flood forces on exterior walls. 3.0 DESCRIPTION 3.1 General: Flood Solutions' static Mood vents are engineered, permanently open flood vents with no moving parts that automatically allow flood waters to enter and exit enclosed areas, The vents are constructed of aluminum and available in four models. See Table 1 for model designations and sizes. See Figure 1 for Illustrations of the flood vents. 3.2 Engineetrod Oponing: The Flood Solutions static flood vents comply with the design principle noted in Section 2.6.2.2 of ASCFJSEI 24 for a rate of rise and fall of 5 feet per hour (0.423 mmis). to order to comply with the engineered opening requirement of ASCE/SEI 24, the static flood vents must be installed in accordance with Section 4.0 of this report. 3.3 Ventilation: Flood Solutions' static flood vents may be uced to supply natural ventilation for under -floor ventilation. See Table 1 for net free area for under -floor ventilation provided by each of Flood Solutions' static flood vents. 4.0 DESIGN AND INSTALLATION The Flood Solutions static flood vents are designed to be _ installed into walls - or doors of _9X Sting_ or_new construction_ from the.exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. In order to comply with the engineered opening design principle noted in Section 2.6.2,2 of ASCE/SEI 24, the vents must be installed as follows: • With a minimum of two opening on different sides of each enclosed area. • With a minimum of one vent for the square footage of enclosed area noted in Table 1. • Below the base flood elevation. • With the bottom of the vent located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The static flood vents described in this report comply with, or are a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The static flood vents must be installed in accordance with this report, the applicable code and the manufacturer's Installation instructions. In the event of a conflict, the Instructions in this report govern. 6.2 The static flood vents must not be used in the place of 'breakaway walls' in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED 6.1 Manufacturer's descriptive literature and Installation instructions. 6.2 Detail drawings. 6.3 Engineering calculations In accordanoe with ASCE/SEt 24. 6.4 Duality documentation in accordance with the ICC-ES Acceptance Criteria for Quality Documentation (AC10), dated June 2014. 7.0 IDENTIFICATION The Flood Solutions static flood vents recognized in this report must be identified by a label bearing the manufacturer's name (Flood Solutions), the model number, and the evaluation report number (ESR-3760). [C.C.&S Evoluolton Reports are motto be construed m representtna oexAeucs nr any oche. atnbwu nor V—t#cp11y oddrttted. wor an riwy b be construed aran embrsemenl of the subject of tht report Ord ncontmendorron fur Its use- Then is tto wo raniy by Ice Evalmonon serviot 11C, exptw.s or Anpbod as to anr1l1ogna oroome molter In thls report. or ew loony prodret covered by the report. ,y Copyrlphi 0 201E Icc Evduation service, I.I.C. All rights rresemed. Page , of 2 ESR-3760 1 Most Wdely Accepted and Trusted Page 2 of 2 TABLE 1—FLOOD SOLUTIONS STATIC FLOOD VENTS MODEL VENT SIZE ROUGH OPENING (Width x Height) SIZE (In) j (Width x Height) In ENCLOSED AREA COVERAOt: a (� ) NET FREE AREA' (In ) 80.7 FS-1605 `51616 FS-1412 L •. Cl. • .HI 18't, x 10 l7 `, 1 1�xl 182: 16 x 8 _ 16x16 14'/7 x 12 16 z 8 97 191 129 1582 108.7FS-1fi08-Hex 110 61.4 'Available for use ss under -fluor ventilation. r l m ijl1. • r,3! �,f•`t�ll. �;h'•t;hll'1� i i�41i. 1, T a FS. 1616 FS-1608-HEX FIGURE 1—FI,OOD SOLUTIONS STATIC FLOOD VENTS