CONTRACTOR RESPONSE TO PLAN REVIEW COMMENTS:
PROPERTY INFORMATION
Address:
City / State / Zip:
Parcel #: Zoning:
6603 S Indian River Dr Fort Pierce, Fl 34982 3412-141-0002-
000/2 RE-2
APPLICATION INFORMATION
Permit Number: Permit Type:
2004-0595
BUILDING (MISCELLANEOUS)
CONTRACTOR INFORMATION
Contractor Name:
Business Name: Business Addr: City / State / Zip:
Christopher M Quinn
Luxury Renovations And Additions Inc 2740 Sw Martin Down
Blvd #438
Palm City, Fl 34990
REVISIONS INCOMPLETE Joseph Fersch 6/9/2020
(1) Comment: PURSUANT TO SECTION 107 FBC 6TH EDITION 2017 SUBMIT THE PRODUCT APPROVAL FOR THE
ALUMINUM SIDING. AND HIGHLIGHT THE APPLICATION YOU WILL BE USING.
(2) Comment: PURSUANT TO SECTION 107 FBC 6TH EDITION 2017 SUBMIT THE PRODUCT APPROVAL FOR THE
VAPOR BARRIER. AND HIGHLIGHT THE APPLICATION YOU WILL BE USING.
(3) Comment: PURSUANT TO SECTION 107 FBC 6TH EDITION 2017 SUBMIT DETAIL OF WHAT THE STRUCTURE IS
CONSTRUCTED OF.
Response:
1: Please see attached the revised documentation for Alum. Siding product approval
a) Documents: “Dizal FPA” & “FL22530_R1_AE_PER6901 SS 2020-06-05”
2: Please see attached the revised documentation for Vapor Barrier
a) Document: HydroStop_PremiumCoat_System__MiamiDade_Approval_18032109
3: Please see attached
a) Document: Ext. Wall Composition
6/9/20
6/9/20
6/9/20
SIDE VIEW EXTERIOR WALL COMPOSITION DETAIL
FL.O~IOA OUPAR'l'MiilN'l' 01=
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search I
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > _8_pplication List > Application Detail
FL#
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
FL22530-R1
Revision
2017
Validated
D
Dizal Inc
4000 Jean-Marchand Local 108
Quebec QC
Canada, NON-US 00000
(418) 915-9400
lou isandre@d izal. com
Louis-Andre Gaudreau
lou isandre@d izal. com
Panel Walls
Siding
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
D Evaluation Report -Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year ( of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Summary of Products
FL#
22530.1
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/ A
Model, Number or Name
Aluminum Siding
Hermes F. Norero, P.E.
PE-73778
Architectural Testing, Inc., an Intertek Company
12/31/2020
Locke Bowden P. E.
D Validation Checklist -Hardcopy Received
FL22530 Rl COi COi DIZAL SS 2020-06-08. Rdf
Standard
AAMA 501
ASTM E283
ASTM E330
ASTM E330
ASTM E331
Method 1 Option D
06/09/2020
06/09/2020
Description
6" Cladding System
Installation Instructions
FL22530 Rl II DZL001 SS 2020-06-08,Rdf
Verified By: Hermes F. Norero Florida P.E. 73778
Created by Independent Third Party: Yes
Evaluation Reports
Other: See Installations Instructions and Product Evaluation Report for design pressure tables and limitations of FL22530 Rl AE PER6901 SS 2020-06-05,Rdf
use. Created by Independent Third Party: Yes
22530.2 Architectural Aluminum Panels Architectural Aluminum Panels
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL22530 Rl II DZL002 SS 2020-06-08,Rdf
Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/ A Evaluation Reports
Other: See Installations Instructions and Product Evaluation Report for design pressure tables and limitations of FL22530 Rl AE PER6902 SS 2020-06-05,Rdf
use. Created by Independent Third Party: Yes
Contact Us : : 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cop_yright 2007-2013 State of Florida. : : Privacy Statement : : Accessibility Statement : : Refund Statement
Year
2015
2004
2002
2014
2000
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact
850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However
email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
~ E ISl ~ El
Credit Card
Safe
sccuri t v M~.T1ucs
I
398 East Dania Beach Blvd.
Suite 338
Dania Beach, FL 33004
954.399.8478 PH
954.744.4738 FX
contact@buildingdrops.com
Hermes F. Norero, P.E.
Florida No. 73778
BUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization: 29578
Product Evaluation Report
of
DiZal Inc.®
Aluminum Siding 6” Cladding System
Non-Impact Rated
for
Florida Product Approval
FL# FL22530
Report No. 6901
Current Florida Building Code
Method: 1 – D (Engineering Evaluation)
Category: Panel Walls
Sub – Category: Siding
Product: Aluminum Siding 6” Cladding System
Materials: Aluminum 6063-T5
Product Dimensions: See Installation Instructions, DZL001
Prepared for:
DiZal Inc.®
4000 Jean-Marchand, Local 108
Quebec, QC, Canada G2C 1Y6
Prepared by:
Hermes F. Norero, P.E.
Florida Professional Engineer # 73778
Date: 06/08/2020
Contents:
Evaluation Report Pages 1 – 3
Digitally signed by Hermes F Norero
Reason: I am approving this document
Date: 2020.06.09 22:22:58 -04'00'
FL#: FL22530
Date: 06/08/2020
Report No: 6901
Hermes F. Norero, P.E.
Florida No. 73778
Page 2 of 3
BUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization: 29578
Manufacturer: DiZal Inc.®
Product Category: Panel Walls
Product Sub-Category: Siding
Compliance Method: State Product Approval Method (1)(d)
Product Name: Aluminum Siding 6” Cladding System
Non-Impact Rated
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for DiZal Inc.® based
on Method 1d of the State of Florida Product Approval, Florida Department of Business and
Professional Regulation - Florida Building Commission.
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing
or distributing the product or in any other entity involved in the approval process of the product named
herein.
This product has been evaluated for use in locations adhering to the Current Florida Building
Code.
See Installation Instructions DZL001, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for
specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the Current Florida Building Code,
excluding the “High Velocity Hurricane Zone” (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. This product complies with Chapter 16 of the Current Florida Building Code when used in areas
not requiring wind borne debris protection.
4. Site conditions that deviate from the details of drawing DZL001 require further engineering
analysis by a licensed engineer or registered architect.
5. See Installation Instructions DZL001 for size and design pressure limitations.
FL#: FL22530
Date: 06/08/2020
Report No: 6901
Hermes F. Norero, P.E.
Florida No. 73778
Page 3 of 3
BUILDING DROPS
A Perfect Solution in Every Drop!
Certificate of Authorization: 29578
Quality Assurance: The manufacturer has demonstrated compliance of manufacture of products in
accordance with the Florida Building Code for manufacturing under a quality
assurance program audited by an approved quality assurance entity through
Architectural Testing, Inc (FBC Organization #: QUA1844).
Performance Standards: The product described herein has been tested per:
• ASTM E 330-02
Referenced Data:
1. Product Testing performed by Exova
(FBC Organization #: TST 11132)
Report: Dated:
16-06-M0274-3 03/15/2017
2. Quality Assurance Agency
Architectural Testing, Inc
(FBC Organization #: QUA 1844)
Installation:
Refer to Installation Instructions (DZL001) for anchor spacing and more details of the installation
requirements.
Design Pressure:
Refer to Installation Instructions (DZL001) for design pressures based on size, configuration and glass
types.
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 1 of 11
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: HydroStop® PremiumCoat® System over Concrete & Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.16-0308.02 and consists of pages 1 through 11.
The submitted documentation was reviewed by Jorge L. Acebo.
ROOFING SYSTEM APPROVAL
Categorv: Roofing
Sub-Categorv: Liquid Applied Roof System
Deck Tvpe: Concrete & Wood
Material: Elastomeric
Maximum Design Pressure: -610 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
United Cleaning Concentrate
HydroStop® BanierGuard®
Waterproofing
SureBond Primer
Unibase Primer
Lock-Down Primer
XR-2000 Primer
Acrylex 400 Primer
FlexSealni Sealant
HydroStop® PremiumCoat®
HydroStop® PremiumCoat® Fabtic
HydroStop® Pre1niumCoat® Butter
Grade Flashing
United Coatings™ Roof Mate TCM Flashing
TABLE1
Test
Container Sizes Specification Product Description
1 & 5 Gallon Proprieta1y Biodegradable cleaning agent with specific
functional ingredients for degreasing and
removing soi.ls and biological residues for
proper cleaning of roof surfaces.
2 & 5 Gallon Prop1ieta1y
2 & 5 Gallon Proprieta1y
5 Gallon Proptieta1y
1 & 5 Gallon Proprieta1y
5 Gallon Proprieta1y
1 & 5 Gallon Proprieta1y
1 & 5 Gallon or TAS 139
1 qt. Tube
2 & 5 Gallon Proprieta1y
Rolls Proprieta1y
2 & 5 Gallon Prop1ieta1y
2 & 5 Gallon TAS 139
Pri1ning and waterproofing compound for
masomy surfaces.
Acrylic primer used for sealing masomy,
metal and chalky surfaces.
Low viscosity, highly penet rating, ac1ylic
polymer primer.
Moisture-Cure Urethane Primer For
Co1rnsion Protection On Metal Surfaces
Water-based Acrylic p1imer for Kynar
coated metal
Acrylic latex primer for use over metal,
masomy and wood surfaces.
Solvent-based, elastomeric sealant.
Ac1ylic elastomeric wate1proofing
compound used as a base layer in the
PremiumCoat® System.
Reinforcing fabric for the PremiumCoat®
System and/or BanierGuard®.
Acrylic elastomeric sealant for bridging
gaps, filling voids and low lying roof areas.
Water based, high solids, elastomeric
sealant.
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06 /28/18
Page 2 ofll
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 3 of 11
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Container Sizes
Test
Specification
Product Description
United Coatings™ Roof Mate Liquid
Fabric
5 & 55 Gallon TAS 139 Water based, sprayable highly elastic
flashing compound.
HydroStop® PremiumCoat® Finish
Coat
2 & 5 Gallon ASTM D6083 Acrylic elastomeric waterproofing
compound used as a top layer in the
PremiumCoat® System.
HydroStop® TrafficCoat Deck
Coating
2 & 5 Gallon Proprietary Acrylic elastomeric waterproofing
compound used as a non-skid surfacing
layer over the PremiumCoat® System.
GAF 2-Part Roofing Adhesive 1:1 Applicator Proprietary A two-part VOC free polyurethane foam
adhesive
LRF Adhesive M
1:1 Applicator Proprietary A two-part VOC free polyurethane foam
adhesive
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
EnergyGuard™ Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuard™ Tapered Polyiso Insulation
Polyisocyanurate foam insulation GAF
EnergyGuard™ Ultra Polyiso Insulation
Polyisocyanurate foam insulation GAF
EnergyGuard™ Ultra Tapered Polyiso Insulation
Polyisocyanurate foam insulation GAF
EnergyGuard™ RA Polyiso Insulation
Polyisocyanurate foam insulation GAF
ACFoam-IV Polyisocyanurate foam insulation Atlas Roofing Corporation
Dens Deck® Gypsum Board Georgia Pacific Gypsum LLC
Dens Deck® Prime® Gypsum Board Georgia Pacific Gypsum LLC
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 4 of 11
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Atlantic & Caribbean Roof 09-018 TAS 114 10/27/09
Consulting, LLC 09-019 TAS 114 10/27/09
09-020 TAS 114 10/28/09
12-020 TAS 114 05/08/12
FM Approvals 3031350 FM 4470 09/27/07
3036182 FM 4470 07/31/09
3041769 FM 4470 05/26/11
3045166 FM 4470 07/24/12
3047636 FM 4470 08/08/13
FM Letter 3048066 FM 4470 12/13/13
RR204740 FM 4470 03/29/16
RR204845 FM 4470 04/08/16
RR204846 FM 4470 04/08/16
PRI Construction Materials GAF-369-02-01 ASTM C1289 10/22/12
Technologies LLC GAF-464-02-01 ASTM C1289 02/06/14
GAF-629-02-01 ASTM C1289 03/01/16
GAF-654-02-01 TAS 114 05/19/16
GAF-658-02-01 Proprietary 06/07/16
GAF-659-02-01 Proprietary 06/03/16
GAF-660-02-01 Proprietary 06/03/16
GAF-661-02-01 Proprietary 06/03/16
GAF-662-02-01 Proprietary 06/07/16
GAF-664-02-01 Proprietary 06/03/16
GAF-665-02-01 Proprietary 06/03/16
GAF-667-02-01 TAS 139 07/01/16
GAF-668-02-01 TAS 139 07/01/16
GAF-671-02-01 TAS 139 07/01/16
GAF-674-02-01 Proprietary 06/01/16
GAF-675-02-01 Proprietary 06/01/16
GAF-676-02-01 Proprietary 06/01/16
GAF-678-02-01 Proprietary 07/14/16
GAF-679-02-01 Proprietary 06/01/16
GAF-680-02-01 Proprietary 06/01/16
HSI-007-02-01 ASTM D6083 05/20/16
HSI-009-02-01 ASTM D6083 05/20/16
Trinity|ERD 4697.12.00-1 TAS 114 12/07/00
Underwriters Laboratories R26758 UL 790 02/09/16
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 5 of 11
APPROVED ASSEMBLIES
Membrane Type: Liquid Applied Membrane
Deck Type 3I: Concrete Decks, Insulated
Deck Description: Structural Concrete
System Type A(1): Insulation adhered to roof deck. Membrane fully adhered to insulation.
HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The
following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative
for specific/complete installation instructions.
All General and System Limitations apply.
One or more layers of the following insulations.
Insulation: Insulation Fasteners
(Table 3)
Fastener
Density/ft2
EnergyGuard™ Polyiso Insulation, EnergyGuard™ Tapered Polyiso Insulation, EnergyGuard™ Ultra Polyiso
Insulation, EnergyGuard™ Ultra Tapered Polyiso Insulation
Minimum 1” thick N/A N/A
Note: Insulation is adhered with OlyBond® 500 Adhesive, OlyBond® 500 Green, LRF Adhesive M, Millennium
One Step™ Foamable Adhesive, Millennium One Step Green® Foamable Adhesive applied in 1” wide ribbons
spaced 12” o.c. OR with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12” o.c. Please refer
to Roofing Application Standard RAS 117 for insulation attachment.
Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top
insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop®
PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then
saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq.
Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25
gal./sq.
HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat®
Foundation Coat base coat within 4 in. wide seams and is saturated with additional
HydroStop® PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq.
Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum
rate of 0.75 gal./sq. per coat.
Surfacing:
(Optional)
HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions.
*This Assembly is not Approved for use as a Waterproofing Assembly*
Maximum Design
Pressure: -223 psf. (See General Limitation #9)
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 6 of 11
Membrane Type: Liquid Applied Membrane
Deck Type 3I: Concrete Decks, Insulated
Deck Description: Structural Concrete
System Type A(2): Insulation adhered to roof deck. Membrane fully adhered to insulation.
HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The
following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative
for specific/complete installation instructions.
All General and System Limitations apply.
One or more layers of the following insulations.
Base Insulation Layer: Insulation Fasteners
(Table 3)
Fastener
Density/ft2
EnergyGuard™ Polyiso Insulation, EnergyGuard™ Tapered Polyiso Insulation, EnergyGuard™ Ultra Polyiso
Insulation, EnergyGuard™ Ultra Tapered Polyiso Insulation
Minimum 1/2” thick N/A N/A
Top Insulation Layer: Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Dens Deck®
Minimum ¼” thick N/A N/A
Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5 in. wide ribbons spaced 12” o.c.
OR with OlyBond® 500 Adhesive, OlyBond® 500 Green, LRF Adhesive M, Millennium One Step™ Foamable
Adhesive, Millennium One Step Green® Foamable Adhesive applied in 0.75” – 1.0” wide ribbons spaced 12” o.c.
Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base
Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the
final membrane substrate.
Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top
insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop®
PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then
saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq.
Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq.
HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat®
Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop®
PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq.
Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate
of 0.75 gal./sq. per coat.
Surfacing:
(Optional)
HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions.
*This Assembly is not Approved for use as a Waterproofing Assembly*
Maximum Design
Pressure: -135 psf. (See General Limitation #9)
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 7 of 11
Membrane Type: Liquid Applied Membrane
Deck Type 3I: Concrete Decks, Insulated
Deck Description: Structural Concrete
System Type A(3): Insulation adhered to roof deck. Membrane fully adhered to insulation.
HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The
following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative
for specific/complete installation instructions.
All General and System Limitations apply.
One or more layers of the following insulations.
Base Insulation Layer: Insulation Fasteners
(Table 3)
Fastener
Density/ft2
EnergyGuard™ Polyiso Insulation, EnergyGuard™ Tapered Polyiso Insulation, EnergyGuard™ Ultra Polyiso
Insulation, EnergyGuard™ Ultra Tapered Polyiso Insulation
Minimum 1.5” thick N/A N/A
Top Insulation Layer: Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Dens Deck® Prime®
Minimum ¼” thick N/A N/A
Note: Insulation is adhered with OlyBond® 500 Adhesive, OlyBond® 500 Green or LRF Adhesive M,
Millennium One Step™ Foamable Adhesive, Millennium One Step Green® Foamable Adhesive applied in 1”
wide ribbons spaced 12” o.c. OR with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12”
o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base
Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the
final membrane substrate.
Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top
insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop®
PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then
saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq.
Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq.
HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat®
Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop®
PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq.
Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate
of 0.75 gal./sq. per coat.
Surfacing:
(Optional)
HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions.
*This Assembly is not Approved for use as a Waterproofing Assembly*
Maximum Design
Pressure: -335 psf. (See General Limitation #9)
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 8 of 11
Membrane Type: Liquid Applied Membrane
Deck Type 3I: Concrete Decks, Insulated
Deck Description: Structural Concrete
System Type A(4): Insulation adhered to roof deck. Membrane fully adhered to insulation.
HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The
following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative
for specific/complete installation instructions.
All General and System Limitations apply.
One or more layers of the following insulation.
Insulation Layer: Insulation Fasteners
(Table 3)
Fastener
Density/ft2
EnergyGuard™ RA Polyiso Insulation
Minimum 1.5” thick N/A N/A
Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12” o.c.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top
insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop®
PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then
saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq.
Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq.
HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat®
Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop®
PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq.
Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate
of 0.75 gal./sq. per coat.
Surfacing:
(Optional)
HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions.
*This Assembly is not Approved for use as a Waterproofing Assembly*
Maximum Design
Pressure: -390 psf (See General Limitation #9)
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 9 of 11
Membrane Type: Liquid Applied Membrane
Deck Type 3I: Concrete Decks, Insulated
Deck Description: Structural Concrete
System Type A(5): Insulation adhered to roof deck. Membrane fully adhered to insulation.
HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The
following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative
for specific/complete installation instructions.
All General and System Limitations apply.
One or more layers of the following insulation.
Insulation Layers: Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-IV
Minimum 1.5” thick N/A N/A
Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12” o.c.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top
insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop®
PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then
saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq.
Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq.
HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat®
Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop®
PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq.
Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate
of 0.75 gal./sq. per coat.
Surfacing:
(Optional)
HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions.
*This Assembly is not Approved for use as a Waterproofing Assembly*
Maximum Design
Pressure: -287.5 psf. (See General Limitation #9)
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 10 of 11
Membrane Type: Liquid Applied Membrane
Deck Type 3: Structural Concrete, non-insulated
Deck: Structural Concrete
System Type F: HydroStop® PremiumCoat® System applied directly to structural concrete.
HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The
following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative
for specific/complete installation instructions.
All General and System limitations apply.
Membrane: HydroStop® BarrierGuard® Waterproofing applied in two (2) coats at a rate of 0.67 gal./sq. per
coat.
SureBond Primer applied at rate of 0.5 gal./sq.
HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq.
HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat®
Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop®
PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq.
Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate
of 0.75 gal./sq. per coat.
Surfacing:
(Optional)
HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions.
*This Assembly is not Approved for use as a Waterproofing Assembly*
Maximum Design
Pressure:
-610 psf (See General Limitation #9)
MANUFACTURER’S REQUIREMENTS:
1. Contractor must be a GAF HydroStop® “Approved Applicator”, trained and familiar with the details and
specifications published by the manufacturer. Proof of this qualification shall be provided in written form from the
manufacturer.
2. Refer to GAF’s published installation instructions for detailed installation requirements and recommendations.
3. HydroStop® PremiumCoat® TrafficCoat is required for traffic bearing surfaces: All pedestrian traffic areas shall be
coated with HydroStop® PremiumCoat® TrafficCoat as non-skid surfacing.
4. The assemblies listed herein are not approved for use as Waterproofing Systems as specified in FBC Building
(HVHZ) 1519.16
NOA No.: 18-0321.09
Expiration Date: 06/22/23
Approval Date: 06/28/18
Page 11 of 11
CONCRETE DECK SYSTEM LIMITATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field
withdrawal resistance testing shall be performed to determine fastener patterns and density. All testing and
fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application
Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer.
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt and/or
adhesives panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform
with Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE