Loading...
HomeMy WebLinkAbout6603 S OCEAN DRIVE PLAN REVIEWER COMMENTS RESPONSE_6.11.20 Mailing Address: 2740 SW Martin Downs Blvd. Palm City, FL 34990 www.LuxReno.org Info@LuxReno.org CONTRACTOR RESPONSE TO PLAN REVIEW COMMENTS: PROPERTY INFORMATION Address: City / State / Zip: Parcel #: Zoning: 6603 S Indian River Dr Fort Pierce, Fl 34982 3412-141-0002- 000/2 RE-2 APPLICATION INFORMATION Permit Number: Permit Type: 2004-0595 BUILDING (MISCELLANEOUS) CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: Christopher M Quinn Luxury Renovations And Additions Inc 2740 Sw Martin Down Blvd #438 Palm City, Fl 34990 REVISIONS INCOMPLETE Joseph Fersch 6/9/2020 (1) Comment: PURSUANT TO SECTION 107 FBC 6TH EDITION 2017 SUBMIT THE PRODUCT APPROVAL FOR THE ALUMINUM SIDING. AND HIGHLIGHT THE APPLICATION YOU WILL BE USING. (2) Comment: PURSUANT TO SECTION 107 FBC 6TH EDITION 2017 SUBMIT THE PRODUCT APPROVAL FOR THE VAPOR BARRIER. AND HIGHLIGHT THE APPLICATION YOU WILL BE USING. (3) Comment: PURSUANT TO SECTION 107 FBC 6TH EDITION 2017 SUBMIT DETAIL OF WHAT THE STRUCTURE IS CONSTRUCTED OF. Response: 1: Please see attached the revised documentation for Alum. Siding product approval a) Documents: “Dizal FPA” & “FL22530_R1_AE_PER6901 SS 2020-06-05” 2: Please see attached the revised documentation for Vapor Barrier a) Document: HydroStop_PremiumCoat_System__MiamiDade_Approval_18032109 3: Please see attached a) Document: Ext. Wall Composition 6/9/20 6/9/20 6/9/20 SIDE VIEW EXTERIOR WALL COMPOSITION DETAIL FL.O~IOA OUPAR'l'MiilN'l' 01= BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search I Product Approval USER: Public User Product Approval Menu > Product or Application Search > _8_pplication List > Application Detail FL# Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory FL22530-R1 Revision 2017 Validated D Dizal Inc 4000 Jean-Marchand Local 108 Quebec QC Canada, NON-US 00000 (418) 915-9400 lou isandre@d izal. com Louis-Andre Gaudreau lou isandre@d izal. com Panel Walls Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report -Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year ( of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Summary of Products FL# 22530.1 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/ A Model, Number or Name Aluminum Siding Hermes F. Norero, P.E. PE-73778 Architectural Testing, Inc., an Intertek Company 12/31/2020 Locke Bowden P. E. D Validation Checklist -Hardcopy Received FL22530 Rl COi COi DIZAL SS 2020-06-08. Rdf Standard AAMA 501 ASTM E283 ASTM E330 ASTM E330 ASTM E331 Method 1 Option D 06/09/2020 06/09/2020 Description 6" Cladding System Installation Instructions FL22530 Rl II DZL001 SS 2020-06-08,Rdf Verified By: Hermes F. Norero Florida P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports Other: See Installations Instructions and Product Evaluation Report for design pressure tables and limitations of FL22530 Rl AE PER6901 SS 2020-06-05,Rdf use. Created by Independent Third Party: Yes 22530.2 Architectural Aluminum Panels Architectural Aluminum Panels Limits of Use Installation Instructions Approved for use in HVHZ: No FL22530 Rl II DZL002 SS 2020-06-08,Rdf Approved for use outside HVHZ: Yes Verified By: Hermes F. Norero, P.E. Florida P.E. 73778 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/ A Evaluation Reports Other: See Installations Instructions and Product Evaluation Report for design pressure tables and limitations of FL22530 Rl AE PER6902 SS 2020-06-05,Rdf use. Created by Independent Third Party: Yes Contact Us : : 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cop_yright 2007-2013 State of Florida. : : Privacy Statement : : Accessibility Statement : : Refund Statement Year 2015 2004 2002 2014 2000 Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ~ E ISl ~ El Credit Card Safe sccuri t v M~.T1ucs I 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Product Evaluation Report of DiZal Inc.® Aluminum Siding 6” Cladding System Non-Impact Rated for Florida Product Approval FL# FL22530 Report No. 6901 Current Florida Building Code Method: 1 – D (Engineering Evaluation) Category: Panel Walls Sub – Category: Siding Product: Aluminum Siding 6” Cladding System Materials: Aluminum 6063-T5 Product Dimensions: See Installation Instructions, DZL001 Prepared for: DiZal Inc.® 4000 Jean-Marchand, Local 108 Quebec, QC, Canada G2C 1Y6 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date: 06/08/2020 Contents: Evaluation Report Pages 1 – 3 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2020.06.09 22:22:58 -04'00' FL#: FL22530 Date: 06/08/2020 Report No: 6901 Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 3 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Manufacturer: DiZal Inc.® Product Category: Panel Walls Product Sub-Category: Siding Compliance Method: State Product Approval Method (1)(d) Product Name: Aluminum Siding 6” Cladding System Non-Impact Rated Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for DiZal Inc.® based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions DZL001, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the Current Florida Building Code, excluding the “High Velocity Hurricane Zone” (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. This product complies with Chapter 16 of the Current Florida Building Code when used in areas not requiring wind borne debris protection. 4. Site conditions that deviate from the details of drawing DZL001 require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions DZL001 for size and design pressure limitations. FL#: FL22530 Date: 06/08/2020 Report No: 6901 Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 3 BUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 Quality Assurance: The manufacturer has demonstrated compliance of manufacture of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through Architectural Testing, Inc (FBC Organization #: QUA1844). Performance Standards: The product described herein has been tested per: • ASTM E 330-02 Referenced Data: 1. Product Testing performed by Exova (FBC Organization #: TST 11132) Report: Dated: 16-06-M0274-3 03/15/2017 2. Quality Assurance Agency Architectural Testing, Inc (FBC Organization #: QUA 1844) Installation: Refer to Installation Instructions (DZL001) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (DZL001) for design pressures based on size, configuration and glass types. NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 1 of 11 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: HydroStop® PremiumCoat® System over Concrete & Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.16-0308.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Jorge L. Acebo. ROOFING SYSTEM APPROVAL Categorv: Roofing Sub-Categorv: Liquid Applied Roof System Deck Tvpe: Concrete & Wood Material: Elastomeric Maximum Design Pressure: -610 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product United Cleaning Concentrate HydroStop® BanierGuard® Waterproofing SureBond Primer Unibase Primer Lock-Down Primer XR-2000 Primer Acrylex 400 Primer FlexSealni Sealant HydroStop® PremiumCoat® HydroStop® PremiumCoat® Fabtic HydroStop® Pre1niumCoat® Butter Grade Flashing United Coatings™ Roof Mate TCM Flashing TABLE1 Test Container Sizes Specification Product Description 1 & 5 Gallon Proprieta1y Biodegradable cleaning agent with specific functional ingredients for degreasing and removing soi.ls and biological residues for proper cleaning of roof surfaces. 2 & 5 Gallon Prop1ieta1y 2 & 5 Gallon Proprieta1y 5 Gallon Proptieta1y 1 & 5 Gallon Proprieta1y 5 Gallon Proprieta1y 1 & 5 Gallon Proprieta1y 1 & 5 Gallon or TAS 139 1 qt. Tube 2 & 5 Gallon Proprieta1y Rolls Proprieta1y 2 & 5 Gallon Prop1ieta1y 2 & 5 Gallon TAS 139 Pri1ning and waterproofing compound for masomy surfaces. Acrylic primer used for sealing masomy, metal and chalky surfaces. Low viscosity, highly penet rating, ac1ylic polymer primer. Moisture-Cure Urethane Primer For Co1rnsion Protection On Metal Surfaces Water-based Acrylic p1imer for Kynar coated metal Acrylic latex primer for use over metal, masomy and wood surfaces. Solvent-based, elastomeric sealant. Ac1ylic elastomeric wate1proofing compound used as a base layer in the PremiumCoat® System. Reinforcing fabric for the PremiumCoat® System and/or BanierGuard®. Acrylic elastomeric sealant for bridging gaps, filling voids and low lying roof areas. Water based, high solids, elastomeric sealant. NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06 /28/18 Page 2 ofll NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 3 of 11 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Container Sizes Test Specification Product Description United Coatings™ Roof Mate Liquid Fabric 5 & 55 Gallon TAS 139 Water based, sprayable highly elastic flashing compound. HydroStop® PremiumCoat® Finish Coat 2 & 5 Gallon ASTM D6083 Acrylic elastomeric waterproofing compound used as a top layer in the PremiumCoat® System. HydroStop® TrafficCoat Deck Coating 2 & 5 Gallon Proprietary Acrylic elastomeric waterproofing compound used as a non-skid surfacing layer over the PremiumCoat® System. GAF 2-Part Roofing Adhesive 1:1 Applicator Proprietary A two-part VOC free polyurethane foam adhesive LRF Adhesive M 1:1 Applicator Proprietary A two-part VOC free polyurethane foam adhesive APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuard™ Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard™ Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard™ Ultra Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard™ Ultra Tapered Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard™ RA Polyiso Insulation Polyisocyanurate foam insulation GAF ACFoam-IV Polyisocyanurate foam insulation Atlas Roofing Corporation Dens Deck® Gypsum Board Georgia Pacific Gypsum LLC Dens Deck® Prime® Gypsum Board Georgia Pacific Gypsum LLC NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 4 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Atlantic & Caribbean Roof 09-018 TAS 114 10/27/09 Consulting, LLC 09-019 TAS 114 10/27/09 09-020 TAS 114 10/28/09 12-020 TAS 114 05/08/12 FM Approvals 3031350 FM 4470 09/27/07 3036182 FM 4470 07/31/09 3041769 FM 4470 05/26/11 3045166 FM 4470 07/24/12 3047636 FM 4470 08/08/13 FM Letter 3048066 FM 4470 12/13/13 RR204740 FM 4470 03/29/16 RR204845 FM 4470 04/08/16 RR204846 FM 4470 04/08/16 PRI Construction Materials GAF-369-02-01 ASTM C1289 10/22/12 Technologies LLC GAF-464-02-01 ASTM C1289 02/06/14 GAF-629-02-01 ASTM C1289 03/01/16 GAF-654-02-01 TAS 114 05/19/16 GAF-658-02-01 Proprietary 06/07/16 GAF-659-02-01 Proprietary 06/03/16 GAF-660-02-01 Proprietary 06/03/16 GAF-661-02-01 Proprietary 06/03/16 GAF-662-02-01 Proprietary 06/07/16 GAF-664-02-01 Proprietary 06/03/16 GAF-665-02-01 Proprietary 06/03/16 GAF-667-02-01 TAS 139 07/01/16 GAF-668-02-01 TAS 139 07/01/16 GAF-671-02-01 TAS 139 07/01/16 GAF-674-02-01 Proprietary 06/01/16 GAF-675-02-01 Proprietary 06/01/16 GAF-676-02-01 Proprietary 06/01/16 GAF-678-02-01 Proprietary 07/14/16 GAF-679-02-01 Proprietary 06/01/16 GAF-680-02-01 Proprietary 06/01/16 HSI-007-02-01 ASTM D6083 05/20/16 HSI-009-02-01 ASTM D6083 05/20/16 Trinity|ERD 4697.12.00-1 TAS 114 12/07/00 Underwriters Laboratories R26758 UL 790 02/09/16 NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 5 of 11 APPROVED ASSEMBLIES Membrane Type: Liquid Applied Membrane Deck Type 3I: Concrete Decks, Insulated Deck Description: Structural Concrete System Type A(1): Insulation adhered to roof deck. Membrane fully adhered to insulation. HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulations. Insulation: Insulation Fasteners (Table 3) Fastener Density/ft2 EnergyGuard™ Polyiso Insulation, EnergyGuard™ Tapered Polyiso Insulation, EnergyGuard™ Ultra Polyiso Insulation, EnergyGuard™ Ultra Tapered Polyiso Insulation Minimum 1” thick N/A N/A Note: Insulation is adhered with OlyBond® 500 Adhesive, OlyBond® 500 Green, LRF Adhesive M, Millennium One Step™ Foamable Adhesive, Millennium One Step Green® Foamable Adhesive applied in 1” wide ribbons spaced 12” o.c. OR with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: (Optional) HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions. *This Assembly is not Approved for use as a Waterproofing Assembly* Maximum Design Pressure: -223 psf. (See General Limitation #9) NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 6 of 11 Membrane Type: Liquid Applied Membrane Deck Type 3I: Concrete Decks, Insulated Deck Description: Structural Concrete System Type A(2): Insulation adhered to roof deck. Membrane fully adhered to insulation. HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulations. Base Insulation Layer: Insulation Fasteners (Table 3) Fastener Density/ft2 EnergyGuard™ Polyiso Insulation, EnergyGuard™ Tapered Polyiso Insulation, EnergyGuard™ Ultra Polyiso Insulation, EnergyGuard™ Ultra Tapered Polyiso Insulation Minimum 1/2” thick N/A N/A Top Insulation Layer: Insulation Fasteners (Table 3) Fastener Density/ft2 Dens Deck® Minimum ¼” thick N/A N/A Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5 in. wide ribbons spaced 12” o.c. OR with OlyBond® 500 Adhesive, OlyBond® 500 Green, LRF Adhesive M, Millennium One Step™ Foamable Adhesive, Millennium One Step Green® Foamable Adhesive applied in 0.75” – 1.0” wide ribbons spaced 12” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: (Optional) HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions. *This Assembly is not Approved for use as a Waterproofing Assembly* Maximum Design Pressure: -135 psf. (See General Limitation #9) NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 7 of 11 Membrane Type: Liquid Applied Membrane Deck Type 3I: Concrete Decks, Insulated Deck Description: Structural Concrete System Type A(3): Insulation adhered to roof deck. Membrane fully adhered to insulation. HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulations. Base Insulation Layer: Insulation Fasteners (Table 3) Fastener Density/ft2 EnergyGuard™ Polyiso Insulation, EnergyGuard™ Tapered Polyiso Insulation, EnergyGuard™ Ultra Polyiso Insulation, EnergyGuard™ Ultra Tapered Polyiso Insulation Minimum 1.5” thick N/A N/A Top Insulation Layer: Insulation Fasteners (Table 3) Fastener Density/ft2 Dens Deck® Prime® Minimum ¼” thick N/A N/A Note: Insulation is adhered with OlyBond® 500 Adhesive, OlyBond® 500 Green or LRF Adhesive M, Millennium One Step™ Foamable Adhesive, Millennium One Step Green® Foamable Adhesive applied in 1” wide ribbons spaced 12” o.c. OR with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: (Optional) HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions. *This Assembly is not Approved for use as a Waterproofing Assembly* Maximum Design Pressure: -335 psf. (See General Limitation #9) NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 8 of 11 Membrane Type: Liquid Applied Membrane Deck Type 3I: Concrete Decks, Insulated Deck Description: Structural Concrete System Type A(4): Insulation adhered to roof deck. Membrane fully adhered to insulation. HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulation. Insulation Layer: Insulation Fasteners (Table 3) Fastener Density/ft2 EnergyGuard™ RA Polyiso Insulation Minimum 1.5” thick N/A N/A Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: (Optional) HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions. *This Assembly is not Approved for use as a Waterproofing Assembly* Maximum Design Pressure: -390 psf (See General Limitation #9) NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 9 of 11 Membrane Type: Liquid Applied Membrane Deck Type 3I: Concrete Decks, Insulated Deck Description: Structural Concrete System Type A(5): Insulation adhered to roof deck. Membrane fully adhered to insulation. HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative for specific/complete installation instructions. All General and System Limitations apply. One or more layers of the following insulation. Insulation Layers: Insulation Fasteners (Table 3) Fastener Density/ft2 ACFoam-IV Minimum 1.5” thick N/A N/A Note: Insulation is adhered with GAF 2-Part Roofing Adhesive applied in 2.5” wide ribbons spaced 12” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation Joint Treatment Note: HydroStop® PremiumCoat® Foundation Coat is brush applied over all top insulation layer joints in a 6 in. width at a rate of 1.25 gal./sq. centered about each joint. 6 in. wide HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat. The fabric is then saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at 1.25 gal/sq. Membrane: HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: (Optional) HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions. *This Assembly is not Approved for use as a Waterproofing Assembly* Maximum Design Pressure: -287.5 psf. (See General Limitation #9) NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 10 of 11 Membrane Type: Liquid Applied Membrane Deck Type 3: Structural Concrete, non-insulated Deck: Structural Concrete System Type F: HydroStop® PremiumCoat® System applied directly to structural concrete. HydroStop® PremiumCoat® products shall be installed in accordance with the manufacturer’s specifications. The following are minimum installation guidelines. Consult the manufacturer’s specifications or Technical Repersentative for specific/complete installation instructions. All General and System limitations apply. Membrane: HydroStop® BarrierGuard® Waterproofing applied in two (2) coats at a rate of 0.67 gal./sq. per coat. SureBond Primer applied at rate of 0.5 gal./sq. HydroStop® PremiumCoat® Foundation Coat is brush applied at a minimum rate of 1.25 gal./sq. HydroStop® PremiumCoat® Fabric is embedded in the wet HydroStop® PremiumCoat® Foundation Coat base coat within 4 in. wide seams and is saturated with additional HydroStop® PremiumCoat® Foundation Coat brush applied at a minimum rate of 1.25 gal./sq. Two (2) or more coats of HydroStop® PremiumCoat® Finish Coat are applied at a minimum rate of 0.75 gal./sq. per coat. Surfacing: (Optional) HydroStop® TrafficCoat Deck Coating applied per manufacturer’s installation instructions. *This Assembly is not Approved for use as a Waterproofing Assembly* Maximum Design Pressure: -610 psf (See General Limitation #9) MANUFACTURER’S REQUIREMENTS: 1. Contractor must be a GAF HydroStop® “Approved Applicator”, trained and familiar with the details and specifications published by the manufacturer. Proof of this qualification shall be provided in written form from the manufacturer. 2. Refer to GAF’s published installation instructions for detailed installation requirements and recommendations. 3. HydroStop® PremiumCoat® TrafficCoat is required for traffic bearing surfaces: All pedestrian traffic areas shall be coated with HydroStop® PremiumCoat® TrafficCoat as non-skid surfacing. 4. The assemblies listed herein are not approved for use as Waterproofing Systems as specified in FBC Building (HVHZ) 1519.16 NOA No.: 18-0321.09 Expiration Date: 06/22/23 Approval Date: 06/28/18 Page 11 of 11 CONCRETE DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt and/or adhesives panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE