Loading...
HomeMy WebLinkAbout1 Nail Strip Metal Underlayment4127I2ii?0 'i & L +�ft—l4mwmid- 'A, Log In Use, Registration HotToWi Submit Surcharge Stars & Facts Publicatlorns C=tact Gs Bcis site Map links Se3aQh dbi i Y.. Product Approval '' - USER, Public User PlOdPct A pr41aE Meru a Product erAPuli[ati n arch > @ppll ti ri D a Applicaticn Detail FL - Application Type Code Version Application Status Comments Archived Product Manufacturer w _ ��tiE�is��E�r�q AsfdresslPhonefEmaii Pc) Box 70 Rutherford, NJ 07070 (800) 516-1485 david.ruiz@tribuiltmg.com Authorized Signature David RUIZ david. ruin@tribe iltmg.com Technical Representative David Ruiz Add ress/Phorte/Email 250 Route 17 North East Rutherford, NJ 07073 (201)842-2449 david-rulz@tribuiltrnaterial5group.com Quality Assurance Representative Address/Phone/Email Category Roo€ing Subcategory Underlayrnents Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who devOaped the Robert Nleminen Evaluation Report Florida License PE-59166 Quality Assurance Entity LIL LLC Quality Assurance Contract Fxplration Date 07/18/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certlfied By FL16048 R6 COI 2017 01 C4I Niernjaq,pdf Standard Year ASTM D1970 2015 ASTM G155 2005 FM 4474 2011 FRSA/TR1 April 2012 t04-12] 2012 UL1897 2012 hops:ltwww.fioridabuilding.Qrglprlpr app_dtl,aspx?param=wGFVXQwtDgtFPmdYiNDWlwipmt nRBjv9FiYHTk4FLCxcgVtRhfvMw%3d%3d 1/2 412712020 Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Hate Validated Date Pending FBC Approval Date Approved Method 1 Option D 09/25/2017 10/01/2017 10/03/2017 12/12/2017 Summary of products w..�n FL Model, Number or Name -- 4$.1 - -- TRI-BUILT Roof Underlayments— L'mits of Use - - -- Approved for use in HVHZ: No Approved for use outside 14VHZ: Yes Impact Resistant; N/A Design Pressure: +;N!A/-150 'Other. 1.) The aesign pressirz rioted Herein pertains to use of foam -on rile systems vvertw the self -adhering a derlaymerlt -ar one lar a; pllcatiOn- See ER SeCtlan 5.5,4 for deta its, 2.) Refer to ER SA&Lion 5 for other Limits of Use. Description Self -adhering, mod-Iffed biturnen roof ttnderiayrnent5 Installation Instructions L16 48 R6 It 20 7 09 FINAL FD T I - BUILT UNDERLAYMENTS FL1 04 -R pdf Verrfied By: Robert Nierninen PE-59166 Created by Independent Third Party: Yes Evaluation Reports EL16048 B§ AE 2017 09 FI AL ER TrZI- BU21LB§RLAYMLNTS FL16048-R6,pr�f Created by Independent Third Party: yes Conrad Us :: 2601 Eia Ir Stnns R d TMIatlassee FL 323s., Phone: ssa-487-1824 The State of Florida is an AA/EI:O empfoyer. Copy hi 20a?- t713 State of Flo - a.:: Pri a Statement ;: gcczs hiiity 5 atem _cl r �pt :: Re€ d stare ent Under Florida law, email addresses are pub]lc records. If you do not want your a -mail address released In response to a pvhrrc-records request, do not send electrooic mall to this entity, instead, contact the of Ice by phone or by tmditionat maiE. If you have any questlons, please contact 650.497.13,35. +Pursuant to Section 455.275(1) Florida Statutes, effecLive October I, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address it thay have one. The emails provlded may be used for official communication with the licensee. However email addresses are public record, If you do not wish to supply a personal address, please piuvide the Department with an email address whl ch rsn be made available to Lhe publi C. To determine if VOL, are a licensee under Chapter 455. F.S., please dick ire . Pr"uucct Approval Accepts- PE CrecjE' r,ard Safe https-llwww,floridabuilding.orglprlprapp-dil,aspx?param--wGEVxQwtDgtFPmdYil iDWrwipmtAnR8jv9FiYHTk4FLCxcgV#RhfvMw%3d%3d 212 TPJNITY ERD EVALUATION REPORT TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, N1 07070 (800) 516-1485 EXTERIOR. RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Allon Report ►442iz 6 R Date of Issuance: 10125 2012 Revision 6: 09ji''SJ2 17 SCOPE; — --- This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein. - .:.:_ LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the wards "TrinityIERD Evaluated' may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INsPEc-nON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection atthe job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: l A11.�1 � Ili etc Fr',fr' r �=1 5'11'RY-� •� Robert J.M. Nieminen, P.E. �Is+ <...� �1•``�s' The fa cSlmlle seal appearing was auth onxcd by Roben Nieminen, Florida Registration No- 5,gisc, Florida DCA �{NE1983 P.E- on 09/25i2017. 7his does not some as an eiectroni early signed CEgTrFICAT}ON OF INDEPENDENCE,d�mrnt. 1. Trinity] ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E- does not have, nor will acquire, a financial Interest in any other entity 'involved in the approval process of the product. S. This is a building code evaluation. neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: I. SCOPE: Product Category: Roofing Sub -Category: Under)ayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6'h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1504.3.1 1504.3A 1504.6 1507.2.4 / 1507.1.1, 1507.2.9.2 1507.3.3 3. REFERENCES: Entity ERD {TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) E R D (TST6049) ERD (TST6049) E R D (TST6049 ) ERD (TST6049) ERD (TST6049) ERD (T5T6049) ERD (TST6049) ERD (TST6049) ERD (T5T6049) UL, LLC. (QUA9625) UL, LLC. (QUA9625) 4. PRODUCT DESCRIPTION: Property Wind Resistance Wind Uplift Accelerated Weathering Physical Properties Physical Properties Examination Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Accelerated Weathering Wind Resistance Quality Control Quality Control Standard FM 4474 UL 1897 ASTM G155 ASTM D1970 FRSA/TRI April 2012 (04-12) Reference S40540.02.13-1 S40540.11.13 540540.03.14 544870.04,14-2 S44870,04.14-3 S44870.04.14-1 S44870.04.14-4 S43530,02.14-1-R 1 S43530-05.14 540540.10.14 SC7645.02.15 SC8520.04.15 SC14045.05.17-R1 Multiple -Listing R16814 Service Confirmation Year 2011 2012 2005 2015 2012 Crate 02/19/2013 11/19/2013 03/26/2014 04/02/2014 04J02/2014 04/10/2014 04/10/2014 05/14/2014 05/28/2014 10/31/2014 02/13/2015 05/27/2015 06/07/2017 12/10/2015 Exp.07118/2020 4.1 Trl-Built Sand-R SA Shingle Llnderlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SB5 modified bitumen roof underlayment, with a 36-Inch sheet width; meets ASTM D1970. 4.2 Tri-guilt S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, 58S modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. is a self -adhering, glass -mat reinforced, film -surfaced, 58S modified bitumen roof underlayment; meets ASTM ❑1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityIERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Di rectory for fire ratings of this product. Exterior Research and Design, MC. ,H EvaluatFgn Repgr[A429fiU.1f2.12-Rfi Certlj%ate ojAuthnrixatfon #93p3 6 I:L DON (2017) FBC NON-HVHZ EVALUATION FL16048•Rfi TRI-SUILT Roof Under] ayments; (Soo) Sifi-1485 Revision 6.09/2512017 Page 2 of 6 TRINITY ERD 5.4 TRI-SUiLT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may he made to the Authority Having Jurisdiction for approval based an this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowgble Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Wood shakes Shingles Nail -Orr Tile Foam -On Tile Slate Ln & ShinglesBuilt Sand -It SA Shingle er€ayment Y No No No Yes Yes Tri-Buift S/A HT TU I Yes Underlayment Yes Yes See S.5.1 Yes Yes Yes Yes No No Yes Yes 5.5.1 "Foam-0n Tile" is limited to use of the following Approved the adhesives / underlayment combinations. TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Adhesive Florida Product Approval Underlayments lCP Adhesives Polysett AH 160 FL6332 Tri-Built S/A HT TU Underfayment ❑ow TleBond— FL22525 I Tri-Built S/A HT TU Under]ayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand-R 5A Shingle Underlayment, Fri -Built S/A HT TU Underlayment or Tri-Built Smooth HIT S/A Underlayment applied to: Plywood; ASTM D41 primed plywood; 0513; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, ❑SB or Southern Yellow Pine substrates, TR€-BUILT Materials Group, LLC recommends priming the deck if the 'final roof cover is not stated for installation within 24 hours. Mote: TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or ❑SB prior to installation of the self -adhering Underlayment. 5.6.2 Bond -to -Insulation: Tri-Built Sand-R SA Shingle Underlayment, Tri-guilt S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: Dens Deck Prime; 5ECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix a orTAS 114, Appendix J. Refer to T;Ye Man Ufacturer's orAdhesive h4anufasturer's Florida Pro Gfuct Approval for Overturning Moment Resistance Performance. Exterior Research and Desrgn, LLC. Evaluation Report A429[0,10.12-Rfi CertifJrate of Aercharizprlon </9SG3 6'" EDITION (20171 FBC N0N-HVH2 EVALUATION FL16048-R6 TRI-8UILT Roof Underlayments; (800) sI6-1485 Revlsion 6: 04/25/2017 Page 3 & 6 . TRINITY ERR 5.6.3 Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ASTM D226, Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on the systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). 5.6.4 Wind Resistance for Underla ment Systems in Foam -On Tile A Iications: FRSA/TRl April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile appiications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1SO4.9 has already been applied)_ Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or F$C 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 sf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #2 Maximum Design Pressure = -67.5 sf: Deck. Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: 5aprema Elastocof 600c Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #t3 Maximum Desi n pressure = -150.0 psf. Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Raving Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. #4 Maximum Design Pressure = -60.0 sf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c, in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. Exterior Research and Design, WE. Evaluation Report A42960.10.12•R6 Cert►ftcufeofAathorizotion #9503 6'" EDMON (2017) FBC NON-14V11Z EVALUATION TRi-BUILT Raof Underlayments; {800j 516.1485 fL1fi048-R6 Revision fi: 09/2,5j2017 Page 4 of 6 TRIN" ERD 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shalf meet or exceed that required under FRSA/TRI April2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBI= 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies markers with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zane 2/3 enhancements. S•7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built 5/A HTTU Underlayment shall not be left exposed for longer than 18"ays after installation. 5.8 Tile Slippage Limitations (TAS 103 Per FR5A TRI April 2012 04-12 When loading roof tiles on the underiayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only he exceeded by using battens during loading of the roof tiles. TABLE 2; TILE SLIPPAGE LIMITATIONS FOR DIFlECT-DFcK Ti LE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max.10-tile stack 6.12 Lugged Max. 1ff-tile stack 512 Max. 10-tile stack (bottom 2-tile stark shall be inverted, followed by 8 tiles high 6.12 an slope, as shown below) Tri-Built 5/A HT TU t Underlayment 11 4 Lugged Exterior Research and Design, LLC. Cert7flrate of AuthwfivieuA 1K9509 evaluation Report A42960.10.12-R6 5�" EDITION (2017j IBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; IBM) 516-1485 Revision 6; 09/25/2017 Page 5 of 5 TRINITY ERD S. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC Published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Built Sand-R SA Shin le Underla meat Tri-Built S A HT TU Underla ment or Tri-Built Smooth HT S A Underla meat: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 63.2 Non -Tile applications - While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible, Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed fn accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6,3.3 Tile A lications Tri-built 5 A HT TU Underfa ment only): Reference is made to FRSA/TRr April 2012 (04-12) installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on the applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSAITRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment, See Table 2 herein, and TRI-BUILT Materials Group, I.LC published requirements for the staging. 7. BUILDING PERMrrREQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UI_, LLC —ClUA962S; (314) 578-3406; k.chancelfor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. CertijicotevfAurhari:piton #95D3 Evaluation Report A42960.20.12-R6 6'� EDITION 120171 F0C NON-HVHP EVALUATION FLIG049-RG TRI-BUILT Roof Underlaymerrts; (8001516-1485 Revision G; 09/25/2017 Page 6 of 6