Loading...
HomeMy WebLinkAboutSet-Up Manuals (Generator)s� 2�CkUdL GENERAC GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine INCLUDES: I ��L (� • True Power- Electrical Technology Standby Power Rating Models 3007029-1, G007030-1 (Aluminum - Bisque) - 9 kW 60 Hz • Two Line LCD Multilingual Digital Evolution'" Controller (English/Spanish) Models G007032-1, G007033-1 (Aluminum - Bisque) - 11 kW 60 Hz French/Portuguese) Model G007031 -1 (Aluminum - Bisque) 11 kW 60 Hz • Two Transfer Switch Options Available: 100 Amp 16 Circuit Switch or 200 Amp Service Rated Switch. See Page S for Details. • Standard Wi-Flub Remote Monitoring • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Listed and Labeled by the Southwest Research Institute allowing installation as close as 18' (457 mm) to a structure.` 'Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. ' htrps:llassets.swri.org/GbraryIDirectoiyOf isiedProducts/Cowtfuctimindusuyl 973_DoC_204_13204-01-01_Rev8.pdf FEATURES O INNOVATIVE ENGINE DESIGN 8 RIGOROUS TESTING are at the heart of Generac's success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: V PROTOTYPE TESTED V NEMA MG1-22 EVALUATION N/ SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY GUSTED 05 QUIL / / F� Note: CUL cenifimuon only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL cedifled in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard an all Generac models. it provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at t1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the enure unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Lang life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. O MOBILE LINK'- REMOTE MONITORING: FREE with every Guardian Series Home standby generator. Allows you to monitor the status of your generator from w GENERAC anywhere in the wood using a s ring status tablet to PC. Easily access = ®O O0�4 info rmation, such as the current opemtng status and mairithnance alerts. Connect�PR0MISE ''�` �� your account to your authorized service dealer for fast, friendly and proactive - service. With Mobile Link, you are taken care of before the next power.cutage. GENERAC 9/11 kW features and benefits Engine • GeneracG-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasmamolyrings helpsthe engine fun cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. ' • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. _. • Low oil pressure shutdown system Shutdown protection prevents catastmphic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator •. Revolving field Allows for a smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to tl% prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic • NEMA 3R • Remote mounting Transfers your vital electrical loads to the energized source of power. Can be installed inside or outside for maximum flexibility. Mounts near your existing distribution panel for simple, low-cost installation. Evolution" Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65%dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of five (5) seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for rive (5) minutes every other week Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. GENERAC® 9/11 kW features and benefits installation System `• 1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -din composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents panicles and moisture from entering the fuel regulator and engine, prolonging engine life. Remote Monitoring - • Ability to view generator status Monitor your generator via your smartphone, tablet, or computer at anytime via the Mobile Link application for complete peace of mind • Ability to view generator Exercise/Run Review the generators complete protection profile for exercise hours and total hours and Total Hours • Ability to view generator maintenance Provides maintenance information for your specific model generator when scheduled maintenance is due information • Monthly report with previous month's Detailed monthly reports provide historical generator information activity. • Abilityto view generator battery information Built in battery diagnostics displaying current state of the battery • Weather information Provides detailed local ambient weather conditions for generator location r44 9/11 kW specifications Generator - _ -- `fl c I uen�l, Power Factor 1.0 1.0 Sound output in dB(A) at 230 (7 m) with generator operating at nomul load'• 63 64 Engine ?YP�of.Engfne .. „,�;,,,.,, „ ,,,, <';� .. ... , n k._,._: ,GENEPAG G-Force AOOSeries=„ r. •- GENERACTG,�-ofca 5005edas:.. .. Number of Cylinders 1 _ _2 r„ :530 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Aluminum w/ Cast Iron Sleeve Natural Gas fta/hr (ma/hr) 1/2 Load 90 (2.55) Full Load Liquid Propane fts/hr (gal/hr) [I/hr] 120 (3.40) 1/2 Load 32 (0.87) [3.291 Full Load 50 (1.37) [5.201 Controls 107 (3.03) 159 (4.50) 44 (1.22) 14.621 72 (1.97) ]7.451 'Sound leuelsare den from the been of the generator. Sound levals talsn ham other sides of to generator maybe higher depending on Installation parameters. Ratingdernitions- Standby Appllob [a for supplying emergenrypm rfor the duagon of the Only pmrer outage. No overload capability is available for this rating. (All ratings maccordance with BS5514, 1S03046and OIN6271). ' Madmen lulowlt amps and where are subject Wand WrihH by men hctors as fuel SkOmegalcule mntem,ambienttemperature,altihMe, engirepmreranecwtlifion, at. Madmumgrvrerdecreasesaboetas percent fix each 1,OBOfeet (304.8meters) above see level: and alsowilldecrease alpoOI persons foreach6°C(10'F)above 16-C (60-9. GENERAC® 9/11 kW switch options Limited Circuits Switch Features T • 16 circuits, breakers not included Rated for all classes of load,100% equipment rated, both inductive and • resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual Coil Design. — • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/Ul- 3R aluminum'outdoor enclosure. Multi listed for use with 1"standard, tandem, GFCI and AFCI breakers from • Siemens, Murray, Eaton and Square for the most flexible and cost effective install. Dimensions Height Width Depth 111 H2 W7 W2 Lmmin 26.75 30.1 10.5 13.5 6.91 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 210-#14 Service Rated Smart Switch Features available on 11 kW model only • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SIVI • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resistwelding and sticking. • NEMA/Ul- 3R aluminum outdoor enclosure. Dimensions 200 Amps 120/240, to Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 26.75 30.1 10.5 13.5 6.91 MIT 679.4 764.3 266.7 343.0 175.4 Model G007030-1(9kW) 0007032-1(111(W) No. of Poles '.; 2 Z Current Rating (Amps) 100 100 V4unge Fziidg {yA 20J24010' Utility Voltage Monitor (Fixed)' -Pick-up 80% 80% -Dropout 65% 65% [Return to Uilll, appmx:95sec apprar 15"sec Exercises bi-weekly for 5 minutes'1 Standard Standard ULL(s;;gd`:r ,Standard i.::Standattlr Total Circuits Available 16 16 Tandem breaker Capabilities - BTandems - 8 Tandems - Circuit Breaker Protected Available RMS Symmetrical 10,000 10,000 Fault current @ 250 Volts *Function of Evolution Controller t Can be set to weekly or monthly r Model G007033-1(11kW) Nc. of Poles 2.. Current Rating (Amps) 200 Oltaq a(ing (AC$! fir 120l240', 10 Utility Voltage Monitor (Fixetl)' -Pick-up 80% -Dropout 65% Return'foUtilTy;' approx.-l3sec Exercises bi-weekly for 5 minutes't Standard )'DrLlnedd °t ,m"'�°". 3tegdard F Enclosure Type NEMAAIL 3R Circurtaroake[Profe led Lug Range 250 MCM - #6 *Function of Evolution Controller t Can be set to weekly or monthly 9/11 kW GENERAC° available accessories Model # ' Product Description'' L-R The WI-R enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank G007005-0 LP Fuel Level Monitor - Monitoring the LP tames fuel level is an important step in making sure your generator is ready to run during - an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air -coaled standby product'(excluding PowerPact®). G007101-0 Battery The pad warmer rests under the battery. Recommended for use it the temperature regularly falls below O*F. Pad Warmer (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below0°F G007103-1 Breather Warmer The breatherwanner is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch - The auxiliary transfer switch contact kit allows the transfer switch to lack out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, G007027-0 Fascia Base Wrap Kit contoured appearance as well as offering protection from rodents and insects by covering the lifting hales located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006482-0 - 9 kW Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine G006483-0 -11 kW maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other (power management system. - -- --- -- — dimensions & UPCs Dimension Shown areapprn+drvae Refa to insmllalim manual frc met C m mom& DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LFFf81�NElN FRONIVIBI/ Model UPC G007029-1 696471074109 G007030-1 696471074116 G007031-1 696471074123 G007032-1 696471074130 G007033-1 696471074147 GENE RAC' Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com C2018 Gen=roc Pm Systems. too. Al dghs resarved. All specilicatons are subject to change vAlmut notice. Part No. 10000 Mo191.G 03/30/18