HomeMy WebLinkAboutBuilding PlansTERMITE SPECIFICATIONS: R318.1 TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED 7ERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BATTING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION (SEE SECTION 202 , REGISTERED TERMITICIDE). UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." NOTES: .1. METHOD OF TREATMENT SHALL BE APPROVED BY THE GOVERNING JURISDICTION "BOR-A-COR" PRODUCT METHODS MUST BE DETERMINED AT PERMIT STAGE AND PRODUCT APPROVAL DATA MUST BE ON FILE WITH THE BUILDING DEPARTMENT 2. PRESSURE TREATED LUMBER THAT HAS BEEN CUT OR DRILLED THAT EXPOSES UNTREATED PORTIONS. OF WOOD ARE REQUIRED TO BE FIELD TREATED TO PREVENT INSECT INFESTATION 3. BORATE APPLIED TO ALL FRAME MEMBERS WITHIN 24" A.F.F. EXTERIOR COVERING R703.7 EXTERIOR PLASTER. INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C 926 AND ASTM C 1063 AND THE PROVISIONS OF THIS CODE. EXTERIOR WALL LATH ATTACHEMENT R703.7.2 PLASTER. PLASTERING W/ PORTLAND CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHEN APPLIED OVER METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHEN APPLIED OVER MASONRY, CONCRETE R703.7.3 WATER -RESISTIVE BARRIERS. WATER -RESISTIVE BARRIERS SHALL. BE INSTALLED WHERE CEMENT PLASTER (STUCCO) IS TO BE APPLIED OVER - VAPOR -PERM BARRIER. THE INDIVIDUAL WOOD -BASED SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING INTENDED TO DRAIN TO THE WATER -RESISTIVE BARRIER IS DIRECTED BETWEEN THE LAYERS. THE BARRIERS SHALL CONSIST OF ONE OF THE FOLLOWING. 1. TWO LAYERS OF AN APPROVED WATER RESISTANT BARRIER MATERIAL IN ACCORDANCE WITH R703.2. 2. ONE LAYER OF AN APPROVED WATER -RESISTIVE BARRIER (PAPERBACKED STUCCO LATH) OVER AN APPROVED SYNTHETIC HOUSE WRAP. R703.4 FLASHING. APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS, FLASHING SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS. • EXTERIOR WINDOW/DOOR OPENINGS. • INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTIONS WITH FRAME WALLS. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. • CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. • WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. • AT WALL AND ROOF INTERSECTIONS • AT BUILT-IN GUTTERS. MASTER REVISIONS DATE DESCRIPTION STRUCTURAL NOTES: STRUCTURAL DESIGN CRITERIA CAST IN PLACE CONCRETE CODE CRITERIA 1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 2500 PSI (SLABS) 3000 PSI (COLUMNS AND BEAMS), A SLUMP OF 5" FLORIDA BUILDING CODE 6TH EDITION (2017) RESIDENTIAL PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, AND A MAXIMUM WATER/CEMENT RATIO OF 0.63. FLORIDA FIRE PREVENTION CODE 6TH EDITION (2017) 2. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF ALL TOP BARS OF BEAMS. 3. HORIZONTAL FOOTING BARS SHALL BE BENT 25" AROUND CORNERS OR CORNER BARS WITH A 25" LAP PROVIDED EACH WAY. FLORIDA BUILDING CODE ACCESSIBILITY 6TH EDITION (2017) 4. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR 11/2" TO FORM U.N.O. NFPA 70.14, NATIONAL ELECTRICAL CODES (NEC 2014) & 6TH FBCR Ch. 34-43 5. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-1064A/ A1064M. WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT LEAST ONE CROSS WIRE WITHIN BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE - (ACI 318-14) THE 6", OR POLYPROPYLENE FIBERS FOR SLABS ON GRADE TO BE MIN .75 LBS OF FIBER PER CUBIC YARD. SPECIFICATIONS FOR STRUCTURAL CONCRETE - (ACI 301-10) FREE FROM R T ALE IL SHALL MEET ASTM 1 6. ALL REINFORCING STEEL / STIRRUPS AND TIES SHALL BE NEW DOMESTIC DEFORMED BARS E 0 US ,SC & 0 & S S A6 5/ BUILDING COD REQUIREMENTS E EQ IREMENTS FOR MASONRY STRUCTURES - (ACI 530-13) ON PR LAST CONCRETE ADS STEEL WIRE OR PLASTIC SUPPORTS. TOP A615M GRADE 40 U.N.O. REINFORCING FOR FOOTING SHALL BE SUPPORTEDE C P NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION - 2015 EDITION REINFORCING SHALL BE POSITIVELY SUPPORTED BY TEMPORARY STRINGERS. DOWELS FOR COLUMNS & FILLED CELLS SHALL BE SECURED IN PLACE BY WOOD FRAMED CONSTRUCTION MANUAL 2015 EDITION USING ADDITIONAL CROSS -REINFORCING TIED TO FOOTING REINFORCING. SPLICES IN REINFORCING WHERE PERMITTED SHALL BE AS PER DETAIL MS05 ON APA PLYWOOD DESIGN SPECIFICATION 2012 EDITION LINTEL PLAN PAGE. AMERICAN SOCIETY OF CIVIL ENGINEERS: ASCE/SEI 7-10 7. HIGH STRENGTH SIMPSON SET EPDXY -TIE ANCHORING ADHESIVE WAS USED IN THE DESIGN OF THIS PRODUCT. IF CONTRACTORS WISH TO USE A DIFFERENT ALUMINUM DESIGN MANUAL- 201.5 EDITION EPDXY, THEY MUST FIRST CONTACT THE ENGINEER OF RECORD. FOR WRITTEN APPROVAL: S. WHERE PROJECT IS TO BE LOCATED IN KNOWN RADON GAS PREVALENT AREAS, APPENDIX "F" OF THE FLORIDA BUILDING CODE 6th. EDITION (2017) IS TO 1. CODE REQUIREMENTS: IT IS THE INTENT THAT ALL WORK SHALL CONFORM TO THE BE IMPLEMENTED. F303.4.1 CONCRETE STRENGTH IN THESE AREAS ARE TO BE A MINIMUM OF 3000 P.S.I. THEREFORE, ANY AND ALL NOTES ON THESE ADOPTED CODES, STANDARDS AND RULES OF THE ADMINISTRATIVE AUTHORITY PLANS THAT INDICATE 2500 P.S.I. SHALL BE REPLACED WITH 3000 P.S.I. FOR THE CONCRETE STRENGTH. HAVING JURISDICTION. 2. ALL WORK SHALL CONFORM WITH DRAWINGS AND SPECIFICATIONS IN ACCORDANCE MASONRY WALL CONST. WITH THE REQUIREMENTS OF ALL THE FOLLOWING WHERE APPLICABLE: (OMUNICIPAL AND REGULATORY AGENCIES (8) ) LLOCCALAL SSTATATE AND FEDERAL BODIES 1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90-014, WITH A MINIMUM NET COMPRESSIVE STRENGTH OF 1900 PSI (f m - 1500 PSI) DEFLECTION CRITERIA 2. MORTAR SHALL BE 3. COARSE GROUT SHALL CONFO MNFORMING TO ASTM C476 WITH TO ASTIM A7MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 3000 PSI SLUMP 8" T0.11". CONTINUOUS MASONRY! INSPECTIONS ARE REQUIRED DURING CONSTRUCTION. ROOFTRUSSES* LL/360 TL/240 COMMMENTS: 4. GRADE 40 U.N.C. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. 5. GRADE 40 U.N.O. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING OF 192 DIA OR 1OFT, ROOF RAFTERS LL/180 TL/120 • WHICH EVER IS LESS. REINFORCING SHALL BE PLACED IN THE CENTER OF THE MASONRY CELL WITH MIN 1/2" CLEARANCE T0. INSIDE FACE. ROOF RAFTERS (W/O CLG) LL/360 TL/240 6. REINFORCING STEEL SHALL BE LAPPED PER DETAIL MSO5 ON LINTEL PLAN PAGE, UNLESS OTHERWISE NOTED ON THE DRAWINGS. FLOOR TRUSSES/ BEAMS * * LL/360 TL/240 7. GROUT STOPS SHALL BE PROVIDED BELOW BOND BEAM. PLASTIC SCREEN, METAL LATH STRIP OR CAVITY CAPS MAY BE USED TO PREVENT THE FLOW OF FLOOR I,IOIST*** LL/480 TL/240 GROUT INTO CELLS BELOW. THE USE OF FELT PAPER AS' A STOP IS PROHIBITED. 8. TEMPORARY BRACING AND SHORING OF WALL TO PROVIDE STABILITY DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 9. TYPICAL FILLED CELL REINFORCING SIZE AND SPACING SHALL BE ABOVE AND BELOW ALL WALL OPENINGS. 1.0. DO NOT APPLY UNIFORM LOADS TO MASONRY WALLS FOR (3) DAYS AND NO CONCENTRATED LOADS FOR (7) DAYS. PER CODE ACI 318-14. *TL MAX 2" UP TO 40FT SPAN **TL MAX 3/4" *** TL MAX 1/2" 11. CONSOLIDATE AND RECONSOLIDATE GROUT POURS PER CODE. GROUT SHALL BE FLUSH WITH TOP OF WALL GENERAL ROOF LOADING WOOD CONSTRUCTION SHINGLE METAL TILE ROOF (PSF) ROOF (PSF) ROOF (PSF) 1. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR WALLS AND MISC, STRUCTURAL WOOD FRAMING MEMBERS, (LE BLOCKING OR GABLE TOP CHORD LL 20 20 20 END BRACING SHALL BE EITHER AS SPECIFIED IN PLAN OR DETAILS. IF CONFLICTS OCCUR BETW N ET EBETWEEN PLAN AND DETAILS, THE STRONGEST MATERIAL SHALL BE USED. AT MINIMUM, ALL WOOD STRUCTURAL FRAMING MEMBERS SHALL BE S.P.F. #2 TOP CHORD DL 7 7 15 2. ALL LUMBER SPECIFIED ON DRAWINGS ARE INTENDED FOR DRY USE ONLY (MOISTURE CONTENT 19% OR LESS), U.N.O. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHERS 3. ANY WOOD FRAME INTERIOR BEARING WALL STUDS THAT! HAVE HOLES IN THE CENTER OF THE STUD UP TO i" DIA. SHALL HAVE STUD PROTECTION BOTTOM CHORD LL* BOTTOM CHORD DL 0 10 0 SO 0 10 TOTAL (PSF) 37 37 45 SHIELDS. ALL HOLES OVER 1" IN DIA. FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH SIMPSON HSS2 STUD SHOES,TYP.,. U.N.O. 4. MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FOR EXAMPLE, ACQ-C, ACQ-D, BOTTOM CHORD LL (OPT) CBA-A OR CA-S REQUIRE HOT -DIPPED GALVANIZED OR STAINLESS STEEL FASTENERS. DOT SODIUM BORATE (SBX) DOES NOT. S. ALL EXPOSED WOOD OR WOOD W CONTACT WITH EARTH !OR CONCRETE TO BE PRESSURE TREATED. ATTICS W/ LIMITED STORAGE ATTICS W/ HEAVY STORAGE 20. 50 6. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE OR MASONRY.. SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 7. SEE PLAN FOR STUD PACK AND BEAM NAILING PATTERNS. * ATTICS W/ NO STORAGE (NON -CONCURRENT) 10 NOTE: LL REDUCTIONS ARE ALLOWED PER CODE BUT ONLY WITH WRITTEN 8. ALL ENGINEERING LUMBER TO HAVE THE FOLLOWING MIN VALUES U.N.O. PARALLAM COLUMNS: 1.8E Fb = 2400 PSI MICROLAM (LVL) BEAMS: 2.0E Fb= 2600 PSI GLULAM BEAMS: SP/SP 24F-V5 LAYUP 1.7E Fb=2400 PSI MIN. 9. SEE PLAN NOTE FOR ADDITIONAL ROOF, WALL, SHEAR WALL AND FLOOR SHEATHING REQUIREMENTS ALONG W/ NAILING INFORMATION OTHERWISE: APPROVAL FROM FOR OR INDICATED ON PLAN GENERAL FLOOR LOADING HIND: &GA-C ROUPIIOROROSB FLOOR SHEATHING: FLOOR SHEATHING: T&G A-C GROUP 1 APA RATED 48 24 SHEATHING SHALL FINISH FLUSH TO EXTERIOR WALL FACE. ( / ) 0 C WALL SHEATHING: 7/16" STRUCTURAL I OSB EXPOSURE 1 OR 15/32" RATED OSB EXPOSURE 1 20 25 0 10 55 A MINIMUM 1/8 SPACE IS RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS TO ALLOW FOR EXPANSION. PER R604.3.15 SHEATHING SHALL TOP CHORD LL 40 (PSF) COMMENTS: NOT BE USED AS WEATHER RESISTANCE BARRIER UNLESS SPECIFIED. TOP CHORD DIL 10 (PSF) PRE ENGINEERED WOOD TRUSSES BOTTOM CHORD LL 0 (PSF) BOTTOM CHORD DL 5 (PST) 1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH HURRICANE CLIPS OR ANCHORS PER STRUCTURAL PLAN 2. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL DESIGN SPECIFICATION FOR STRESS SPECIAL FLOOR LOADING -GRADE LUMBER AND ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL FOREST PRODUCTS ASSOCIATION. GAME ROOM 60 (PSF) COMMMENTS: 3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPORTIONED H AMAXIMUM ALLOWABLE STRESS INCREASE FOR LOAD DURATION OF 25% TO (WIT ) WITHSTAND THE LIVE LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. BALCONIES/ DECKS 40 (PSF) 4. BRIDGING FOR PRE-ENGINEERED TRUSSES. SHALL BE AS REQUIRED BY THE TRUSS MANUFACTURER UNLESS NOTED ON THE PLANS, BALCONIES OVER 100 SQ:FT 100 (PSF) 5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL CONFIGURATION OFTRUSSES ONLY. WEB MEMBERS ARE NOT SHOWN, BUT SHALL BE DESIGNED BY LIGHT STORAGE 125 (PSF) THE TRUSS MANUFACTURER IN ACCORDANCE WITH THE FRAMING DESIGN LOADS. LIBRARIES READING ROOMS 80 (PSF) 6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL PLATE CONNECTED WOOD TRUSSES PER THE TRUSS PLATE INSTITUTE TPI LATEST EDITION. 7,-PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS AND GOVERNING CODES. STACK ROOMS 150 (PSF) SUBMITTALS SHALL INCLUDE TRUSS FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, GUARDRAIL 0 HAND RAILS (d) 200 (PSF) AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. GUARD RAILS IN FILL COMP. (f) 50 (PSF) S. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. TRUSS SHOP DRAWINGS ROOMS OTHER THAN SLEEPING 40 (PSF) SHALL SHOW ALL TRUSSES, ALL BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. SLEEPING ROOM 30 (PSF) STA1 1 40 (PSF) UPLIFT CONNECTORS FOOT NOTES d. A SINGLE CONCENTRATED LOAD APPLIED IN ANY DIRECTION AT ANY POINT ALONG 1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS ANCHORS AND ANCHOR BOLTS ARE ONLY. REQUIRED ON MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT OR LATERAL FORCES. INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD THE TOR f. BALUSTRADE AND PANELS FILLERS SHALL BE DESIGNED TO WITHSTAND A NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE COORDINATE WITH THE TRUSS ENGINEER FOR THE LOCATION OF THESE WALLS, AND STRUCTURAL PLANS FOR unaF ium HORIZONTALLY APPLIED NORMAL LOAD OF 50 POUNDS ON AN AREA EQUAL TO 1 SQ. FT. WIND LOADING CRITERIA WIND SPEED (ULTIMATE) 160 MPH WIND SPEED (ALLOWABLE) 124 MPH EXPOSURE CATEGORY B BUILDING RISK CATEGORY II BUILDING TYPE V ENCLOSURE CLASSIFICATION ENCLOSED INTERNAL PRESSURE COEFFICIENT +/-0.18 NOTE: MEAN ROOF HEIGHT FOR TYPICAL SINGLE STORY HOME IS 15FT, AND FOR 2 STORY HOME IS 3OFT ASCE 7-10 WALL DESIGN ALLOWABLE COMPONENTS AND CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT 5 30 ft EFFECTIVE WIND PRESSURE WIND PRESSURE WIND AREA AND SUCTION (PSF) AND SUCTION (SQ FEET) (+) VALUE DENOTES PRESSURE (-) VALUE DENOTES SUCTION DIAGRAM AREA (+) 27.6 (+) 27.6 10 (-) 29.9 (-) 37.0 (+) 26.5 (+) 26.5 20 (-} 28.8 (-) 34.4 O 50 (+) 24.8 (+) 24.8 (D O (•) 27.1 (-) 31.1 16 ! Y (+) 23.4 (+) 23.4 100 (-) 25.7 (•) 28.8 DIAGRAM GARAGE DOORS* SOFFIT 9'-O" x 7'-O" 16'-0" x 7'-0" (-) 51.3 (+). 24.3 (+) 23.3 26.0 GENERAL PRESSURE NOTES NOTES: 1. MULTIPLY BY 1.67 TO GET ULTIMATE WIND PRESSURES. 2. "a" = END ZONE IS ONLY W/IN 4'-0" OF ALL EXTERIOR BUILDING CORNERS. * INDICATED PRESSURES CAN BE INTERPOLATED FOR OTHER DOOR SIZES, OTHERWISE USE LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA. 3. DESIGNATED AREAS WHERE THE ULTIMATE WIND SPEED IS 140 MPH OR GREATER AND IS CONSIDERED TO BE IN THE WIND -BOURNE DEBRIS AREA. CONTRACTOR TO PROVIDED ADDITIONAL INFO AS REQUIRED FOR PERMITTING. SEE FLOOR PLAN FOR ACTUAL PRESURES INDEX OF DRAWINGS ISHT NO:I TITLE 1 COVER SHEET 2 FLOOR PLAN 3 FOUNDATION PLAN 4 ELECTRICAL PLAN 5 ELEVATIONS 6 TRUSS LAYOUT S-1 LINTEL PLAN S-2 DETAILS S-3 DETAILS S-4 DETAI LS S-5 PRODUCT INFO SHEET WP WATERPROOFING DETAILS iu®�GTfj I FIELD REPAIR NOTES GENERAL NOTES: BUILDER NOTICE: 1. MISSED "J" BOLTS FOR WOOD BEARING WALLS MAY BE SUBSTITUTED WITH 1/2" DIA. EPDXY ANCHORS WITH 7" EMBEDMENT. SIMPSON "SET" EPDXY 1. ALL EXTERIOR WALLS SHALL BE ASSUMED TO BE LOAD BEARING. SEE PLAN FOR C.M.0 WALL REINFORCEMENT LOCATIONS. tt Is the Intent of Designer/Engineer listed In the titleblock of these ' ADHESIVE BINDER FOLLOWING ALL MANUF C A TURER'S RECOMMENDATIONS OR SIMPSON 1/2" TITEN HD BOLTS WITH MINIMUM 7" EMBEDMENT, SEE 2. WINDOW AND DOOR SUPPLIERS SHALL PROVIDE ROUGH OPENING INFO WHICH SHALL HAVE PRECEDENCE OVER THE PLAN. documents that these documents be accurate, providing Licensed PLAN FOR EMBEDMENT DEPTH AT FLOOR STEPS. 3. CABINET MFRS. SHOP DRAWINGS SHALL HAVE PRECEDENCE OVER THE INTERIOR CABINET ELEVATIONS IF SHOWN. Professionals clear information. Every attempt has been made to j 2. FOR MISSED VERT. DOWELS, DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF THE OMITTED REBAR AND INSTALL A 32" LONG 45 BAR INTO 4. DO NOT SCALE PLANS. DIMENSIONS ARE TO BE FOLLOWED AS INDICATED. prevent error. The Builder and all subcontractors are required to { THE EPDXY FILLED HOLE. USE A TWO PART EMBEDMENT EPDXY (SIMPSON HIGH STRENGTH EPDXY -TIE ANCHORING ADHESIVE:) MIXED PER THE MFGR'S. 5. ALL GLASS LOCATED IN HAZARDOUS LOCATIONS. SHALL COMPLY WITH SECTION R308 OF THE FLORIDA BUILDING CODE review all the information contained in these documents, prior to INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND USING COMPRESSED AIR 6TH EDITION (2017) RESIDENTIAL. the commencement of any work. The Designer/Engineer are not PRIOR TO APPLYING HE EPDXY. ALLOW THE EPDXY TO CURE TO THE MANUFACTURER'S SPECIFICATIONS, THEN FILL THE CELL IN THE NORMAL WAY DURING BOND BEAM responsible for any plan errors, omissions,or misinterpretations CONTROL OF CONSTRUCTION SITE: 3. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT. IN CONC. FILLED CELL EACH SIDE OF THE JOINT ( BAR DOES NOT HAVE TO BE GONT. l not reported to the Designer / Engineer prior to construction. construction. All construction MUST be in accordance the TO FOOTING). KEESEE ASSOCIATES (K4) AND ENGINEER OF RECORD (EOR) HAVE NO CONTROL OVER THE CONSTRUCRON SITE AND SHALL NOT BE RESPONSIBLE IN ANY MANNER FOR CONTROL OF THE information found in these documents. Any questions regarding the , re 4. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY BE SUBSTITUTED WITH (1) SIMPSON MTSM16 TWIST STRAP W/ (4) s/."x 21A" TITENS TO CONSTRUCTION SITE INCLUDING, BUT NOT LIMITED T0, SCHEDULING AND SEQUENCING OF WORK, JOBSITE SAFETY, AND VENTILATION OF THE BUILDING AND THEREBY SHALL NOT BE � , information found in these plans should be directed to our Quality MASONRY AND (7yl.Gd NAILS TO TRUSS FOR UPLIFTS LEST; THAN 860 LBS (USE (2) MTSMi6 FOR UPLIFTS LESS THAN 1720#). IF CORNER STRAP IS RESPONSIBLE FOR HE INDOOR AIR FOR AN REASON WHATSOEVER T QUALITY, OR THE EFFECTS THEREOF Y EAS EV R. KA AND FOR HAS NO DUTY OR OBLIGATION UNDER THIS Q 0 AGREEMENT OR OTHERWISE 1 Assurance Manager 1. e at 32 972 0491 immediately. No backcha e s � Y � MISSED CONTRACTOR S TO INSTALL 2 SIMPSON HGAMSO W 4 1 4" x 11 2" SOS SCREWS AND 5 1 4" x 2 1 4 TITENS ONE EACH SIDE OFTRUSS. ( / O / / O / / TO PROTECT WITHOUT LIMITATION THE RESIDENCE CONSTRUCTION SITE MATERIALS ORE EQUIPMENT, FROM MOISTURE OLD FUNGUS, M FU S FIRE THEFT VANDALISM TRESPASS OR ANY OTHER Q. 0 ER -i will be considered for reimbursement the Designer/Er�glneer PERIL OR CONDITION, AT ANYTIME, EXPRESSLY INCLUDING, BUT NOT LIMITED TO, THE PERIOD OF TIME BEFORE CONSTRUCTION, DURING THE CONSTRUCTION OF THE PROJECT, OR AFTER without advanced notification and approval ro the NO MORE THAN 10 STRAPS MAY BE SUBSTITUTED OR NO MORE THAN 3 IN A ROW WITHOUT APPROVAL FROM EOR. IF GIRDER TRUSS CONNECTIONS ARE CONSTRUCTION AND KA AND FOR HAS NO DUTY TO TAKE ANY ACTION OR PREVENTIVE MEASURES TO PROTECT SUCH PROPERTY AGAINST ANY SUCH PERIL AT ANY TIMEFOR ANY REASON. Designer/Engineer. Payments will be made In accordance to the n MISSED, CONTACT THE FOR FOR SUBSTITUTION. terms of the agreement. ' d 5. IF MISSED, MSTAM36 OR MSTAM40 STRAP IS MISSED FOR 2ND FLOOR JAMB STUD CONNECTION, CONTRACTOR MAY INSTALL SIMPSON HTT5 w/ (26) I 16d x 2A/2" NAILS AND 5/8" ANCHOR BOLT SET IN SIMPSON HIGH STRENGTH EPDXY W/ MIN 6" EMBEDMENT AND MIN 3" EDGE DISTANCE. CONTACT FOR IF STRAPS ARE MISSED UNDER GIRDER JAMB STUD LOCATIONS. �y Drthwest Florida® 300 GU : PARKWAY ��' C UFO . ZE, FLUIaf' 3` ♦'�' Q r: J' cif e. a U3, ri e "-1 z L Pi .O • I- OQte,•j�,� ... `� 4� cc S er"�tUWtt�yl e a Z^� g m Oy EL Q 0 a s - Ul) w ~ a E U Q v, w o V) c coV)M U ENN E W 008 cn c Nv� ¢ ������ .A r%A rrl G• LJON FLORIDA CONTRACTORS LICENSE NO. IRC13301 46 I3000 GULFBREEZE PARKWAY GULFBREEZEr FLORIDAFL RIDA 2563 PORT ST. LUCIE Job Information: a N 0 a a F L1J VVID 9 i LO 3 O 63 Cilu lk to � m LLj (� MLO L2 m V1 Model Name/ Number: 0 1820 � � Plan Issue Date: N a" Wednesday, March 11, 2020 a v KA PROJECT NUMBER: 20-1548 a m Sheet: � Of H r m T U co (.) SLOPE MAY VARY 24" MAXIMUM DEPTH. IF GREATER THAN 24" CONTACT FOR OR REFERENCE FMASW FOR STEM WALL OPTION - GRADE REINF. SEE PLAN Cl N � 16" (2) #5 REBAR FM01 I SINGLE STORY FIG REINF. SEE PLAN _Ff. 00 $" (1) #5 REBAR CONT. (*) SLOPE MAY VARY 24" MAXIMUM DEPTH. GENERAL FOUNDATION NOTES IF GREATER THAN 24" CONTACT FOR OR UNLESS NOTED OTHERWISE REFERENCE FMASW FOR STEM WALL OPTION 8 1 PROVIDE MIN. 6 MIL. APPROVED VAPOR BARRIER. ALL JOINTS TO BE OPTIONAL CURB FOR 'I 'I F F VARIES LAPPED MIN. 6" AND SEALED. MASONRY® ELEV. 0'-0 W/ (1) - #5 BAR CONT. ^ ' 2 4" 2500 PSI CONC. SLAB W/ 6X8 10/10 W W F, OR MINIMUM ,75 LBS OF FIBER PER CUBIC YARD RBERMESH/RBERMIX ADDED TO THE CONCRETE. IN ACCORDANCE W/ MANUFS INSTRUCTIONS AND NER-284 FOR RBERMESH OR NER414 FOR FIBERMIX, OVER 6 MIL VISQUEEN VAPOR BARRIER& TREATED FOR TERMITES. * v ,) 2 STORY: 20" X 20" 3 • INDICATES FILLED CELL W/3000 PSI CONIC. FROM Fill. TO REINF. N W (3) - #5 COM. e; BEAM W/ (1) #5 REBAR GRADE 40 U.N.O. TYPICAL ARV. SLAB. HOOKED FT( SEE PLAN ; ► ; , ; ,' DOWELS 17' EMBEDMENT W/ 25" EXT. ABOVE SLAB. 16" (2) # 5 REBAR 4 CONSULT W/ MANUF. SPECIFICATIONS PRIOR TO POURING OR BEARING RECESSING DOOR SILLS OR SLIDING GLASS DOOR SILLS. 5 EXTERIOR SLABSSHALL SLOPE 1/12" PER FOOTAWAY FROM HOUSE 1/2" = 1'-0" FM02 SECTION @ GARAGE 1/2" = 1'-0" U.N.O. ON PLAN, 6 NO WOOD STAKES PERMITTED IN FOUNDATION. 7 PENDING SITE CONDITIONS, FOUNDATION MAY HAVE TO BE STEPPED DOWN. G.C. TO DETERMINE STEP LOCATIONS IF. REQUIRED. 8 ALL FOOTING SHALL BE MIN 12" BELOW GRADE 9 MASON TO COORDINATE WITH BUILDER ANY ELECTRICAL REQUIREMENT THROUGH SLAB SO PROVIDE 4" STEPDOWN TO SIDEWALK FROM ENTRY it ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM-1557 ( MODIFIED PROCTOR) IN EQUAL LIFTS NOT TO EXCEEDING 12" THE FOUNDATION SIZES INDICATED FM03 I THICKENED EDGE 1/2" = 1'-0" = 1'-O" ON THE FOUNDATION PLAN HAS BEEN DESIGNED FOR A MINIMUM SOIL (") SLOPE MAY VARY 24" MAXIMUM DEPTH. BEARING CAPACITY OF 2000PSF. IF GREATER THAN 24" CONTACT FOR OR REFERENCE FMASW FOR STEM WALL OPTION PROVIDE 13" WIDE FRONT WALL RECESS AT GARAGE OF GARAGE DOOR. EXTEND 6" BEYOND F.O.M. EACH END, TYP. I GAR. FIN. FLR, _ �e ALIGN DRIVE W/ BOTTOM OF ', RECESS & PITCH DRIVE RI ,: 2 STORY: 2( X 20" , 4" DOING. DRIVE W/ 1/2" EXP W/ (3) - #5 CONT. JOINTS 10" O.C. TYP. 16" (2) #5 REBAR FM09 I SECTION @ GAR. DOOR 2x BRG. WALL 2 STORY: 20" X 20" (SEE FLOOR PLAN W/ (3) - #5 CONT. FOR MORE INFORMATION) SEE PLAN - N � y 4" 16" 4" 2-#5 REBAR FM11 I STEP DOWN BRG. 1/2, = r•o" FM12 I STEP DOWN NON BRG. 21 MARK SIZE DEPrH REINFORCING F1 0 1'-0" X CONT. 1'-0" 2 #5 E.W. BOT. P2 OI, 2%0" X T-O" 11-W 3 #5 E.W. BOT. F2 5 a-6" X 2'E' , r-O" 3 #5 E.W. BOT. FS.01, T-O" X T-O" ' 1'-0", 4 #5 E.W. BOT. = 1'-0° [Hill l 3.6" X 3'$" 11-0" 4 #5 E.W. BOT. F4.0, 4-0" X 4'-0" 1'-0" 5 #5 E.W. GOT. F4.5� 4-6"X4.6" 1'4" 5#5 E.W. GOT. WF5.0 �i, 5'-0" X 5'-0" 1'-0" 6 95 E.W. 80T. FBA 6'-0" X 8'-0" 1'-0" 7 #5 E.W. DOT. 1/2" = 1'-0" SEE PLAN OPTIONAL CURB SLOPED GROUT a SEE PLAN OR MASONRY AT TO DRAIN 4"x 4"x 18" a - _ TYP. SEC. 13AR ELEV. WITH �8"�. (1) #5 BAR CON1T. CURB (G.C. VERIFY) �' •' I I �� I I z - • •, F.F. REINF. ., (SEE PLAN) o:.r 2 #5 CONT. INSTALL LINING 2 #5 BENT BARS W/ MATERIALS PER '`r„_ '. p y N . ' •. ' MIN. 25" LAP SPLICE FBC-R P2709.2 MUDDED FLR. 16" .# •� SLOPED TO DRAIN MIN. #5 CONT. FM14 I SECTION @ RECESS SHOWER 1/2"=1,o- FM18 TYP. STEP FIG. DETAIL ./2"=1'-0" ALTERNATE: REINF. THE REINF. BARS SHALL BE #5 NREINF. GRADE SEE PLAN CONTINUOUS AROUND CORNER FONT SEE FOR BY COLD BENDING THE BAR WITH . QUANTITY MIN. BAR LAP OF 25" #5 X 25" X 25" CORNER BAR ONE C4 FOR EA. HORIZ. iv REBAR, TYP. U.N.O. 16" A/C CHASE 4" PVC SLEEVE 2 STORY: 20" X 10" THRU FOOTING W/(3) - #5 CONT. FMJ.91 TYP. CORNER BAR DETAIL 1-1/2"=r-o" FM23 I TYP. FND PENETRATION 1/2"=1'-0" STEMWALL SCHEDULE STEMWALL FOOTING DIMENSION NUMBER/SIZE OF BARS LAT. MAXIMUM F.C. SPACING (D.C.) d 1 STORY d 2 STORY b 1 STORY D 2 STORY HEIGHT (h) IN STEM WALL 0'-0"-2'-0" 8" 10" 16" MI. W/ (2) #5 BARS <674# 61-8" >2'-0"3'-4" 10" 101. 20" 24" W/ (3) #5 BARS 674# 5'-4" >3'-4" - 4'-0" 12" 12" 32" 32" W/ (4) #5 BARS 845# 4'.0" >4'-O" - 5'-4" 16" 161, 48" 48" W/ (5) #5 BARS CONT. 1162# 2'-6" & #5 ® 18" O.C.TRANSV. SEE FOUNDATION PLAN FOR F.C. SPACING ABOVE SLAB LEVEL NOTES: 1.. VERTICAL REINF. IN SOLID GROUTED CELLS AT ALL CORNERS, JAMBS, WALL INTERSECTIONS, BELOW GIRDER TRUSS LOCATIONS, AND AT THE MAXIMUM SEE BV.-MN(. F.C. �� ;; SPACING STATED IN SCHEDULE SPACING NG ((OO 6A "� ,'� 2. 2. W.W.M. IS REQUIRED TO MAKE ADEQUATE CONNECTION BETWEEN SLAB AND B. E W.W.M. TO BE TIED TO #5 CONT. REBAR F.C. ABV. FDN. WALL WHEN STEM WALL EXCEEDS 4'-0" FIBERMESH CAN NOT BE USED AND (1) #5 HORIZ. CONT. TIED TO PER PLAN SPACING #4 TURN BARS ARE REQUIRED 0 EACH FILLED CELL LOCATION. EACH BAR TO EA. VERTICAL REINF. BAR Ee NOTE TIE INTO VERTICAL BAR AND EXTEND OUT A MIN. 4'-0" INTO SLAB/ STEM #4 TURN BAR 0 STEM #B 3. IF STEM IS REQ'D TO BE HIGHER CONTACT ENGINEER OF RECORD PRIOR TO WALLS GREATER THAN CONSTRUCTION FOR MORE INFORMATION a-o" W #5 HORIZ. OONT. TIED " 4. G.C. TO PROVIDE ADEQUATE BRACING OF STEM WALL WHEN UNEVEN BACK El. VERTICAL REINF. " II "16" FILLING IS TAKING PLACE RN GRADE-8' MIN. T y .c. 5. #5 HORIZONTAL CORNER BARS WITH 4'-0" LEGS IN KNOCKOUT BLOCK @ 16" TO TOP OF ' � O.C. VERTICAL. GROUTED SOLID WHEN STEM WALL IS GREATER THAN 4'-0" STRIP FIG. 4! " ` m 1�, TALL (TYPICAL ALL CORNERS) COMPACTED CLEAN FILL ".� ° �! 6. IF STEMWALL IS WITH IN 5'-0" OF POOL OR WATER FEATURE FOUNDATIONS IN MAX 12" UFrS "! TO BE A MINIMUM 12" BELOW BOTTOM OF POOL OR WATER FEATURE, STRIP FrG. W/ QTV of "MIN. COVER *SEE NOTE 5 7. ALL STEM WALLS GREATER THAN (4) COURSES SHALL BE FULLY GROUTED. REINF. PER SCHEDULE e b 8.R.403.1.4 MINIMUN DEPTH: ALL EXTERIOR FOOTINGS (BOTTOM) SHALL BE 13 SHOWN) PLACED AT LEAST 12" BELOW THE UNDISTURBED GROUND SURFACE. 9. EXTERIOR SHORING BY CONTRACTOR AS REQ'D WHEN STEM IS OVER 4'-0" TALL FMASW I STEM WALL SCHEDULE I NITS LEGEND -INDICATES SINGLE -STORY FOOTING ® -INDICATES TWO-STORY FOOTING -INDICATES CONCRETE FOOTING 2000 T200 11000 15600 21500 28000 34500 42500 61500 I:] - COMP. UNIT I rr `\ 14r---- i r - 9' I .T11: I HOSE BIBB Ja a,, 13' 10" 13' 0" 12' 10" 1' B" 4' 0" 3' 6" 4' 8" , 4" 3' 10" 4- 0" 3' 8" ■ __________________________________ ■ ---------- ___________________ , ■ ■ ■ ■ ■ I I I ' I I r ' FMO I I 3 3 ;. FM11 FM11 , I i ¢z ' F2.5 ' I F2.5 _�jl x0 H , t O STEP ON. 4" I I ' 3 TUB , W.C. �.' UNIT' I; I , 1 r'Ir 17 LAV ryk, \ IL ` 10 j1 O _eS -•-- nhAV N - 2' 8" 3' 1" 1' 11" 1 IqL �1 11' W , , I z W.C. ■r _ 00 i' „ v ' ■ TUB S,bYLES VARIES I I VERIf4 DRAIN ; I ' I 4 I LOCJ�TION �; , X I ;3XI ^•�. I F.G. I � .:' ; p\ , SHWR r ; 2'2" 24'8" rr _— Ill 'Drn SINK 12' 11" 0 ROVIDE CHASE ' FOR HVAC UNIT VERIFY LOCATION ; , ' I I O' 9l0 �31 i r — � i FMo1 3 I WASH -------• STEP ON. 4" `;W.H. 'I FMl FM11 3 3 CQ. , , I , FM02 g ¢ `-'------------------^ , .- I , , ' STEP DN. 51h" 20' 0" 6' 4• I � I , I I ao I 3, 8". 7' 0" 2' 8„ 0 F2.5 I ----- I ------- -- , ' I 4" ; FM03 ' 3 ' (V I ' t iO I I I , ---------------- ----a - -- ------ -- '- -' 1[m[t"ujjjjl 111111111111111111111 (2) #5 BARS W/IN EACH F.C. TYP. 0 EA. 2' 0" 16' 0" SIDE OF OPENING 2' 0" 1 6' 4" 13' 4" 20' 0" 39, 8" FOUNDATION PLAN SCALE: 1/4" =1'-O" ALL ELEVATIONS r= FM19 3 nnonlcoc 0 'v 0 ti nS 6 v 00 $ `VX TTT111Td(2A,R •• S E +•� N `• o rd� O Lu Lu sJ,,���TIS II a T�TTIA��`N a le—p O m li 00 L"00 00 g$8 " r 8 p iL g Z�g ; ark =y�� � z o TI S�,S B ■ES�2In .6 G 5 LL m m � 8@� 9 '6 00 K5 zLL 0 E] lNAWJ.FO5ENG.COM ❑ ❑ ❑ IN LID zM 8 z a ¢ `o J a YOQ w E .O � to c m U 6N E —' W O O OM In i•! o c ¢mdno am ® evs�we lue!a>sai'dm FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE ♦ Job Information: 0 F a Z c O y cH W U) c: LD \ / a: m m di "1 LO cc 2 ®JLIJZD M o J m U) U) Lo VI Model Name / Number: 1820 ♦ Plan Issue Date: Wednesday, March 11, 2020 V1 KA PROJECT NUMBER: 20-1548 Sheet: 3 Of: FOUN LOAD CALCULATIONS COOLING GREATER THAN HEATING GENERAL I GHTIN , & RECEPTACLES 3 WATTS PER SQUARE FOOT OF LIVING (THIS FORMULA ALLOWS FOR CEILING FAN CIRCUITS) S.F. LIVING = 1820 x 3 RANGE 8500 OVEN NONE MICRO / HOOD 1000 WATER HEATER 4500 WHIRL POOL 1250 WASHER 1500 DRYER 5000 DISHWASHER 1500 DISPOSAL 600 SMALL APPLIANCE CIRCUITS (3) 4500 BATH FANS 100 WATTS EACH 200 GEN LIGHT'G & RECEPT. + APP. CIR. = 34,010 SUBTRACT 100 % OF FIRST 10,000-10,000 A= 24,010 HVAC CIRCUITS A/C ( AIR HANDLER & COMP.) 10,000 A/C ( AUXILIARY HEAT STRIP.) 10,000 B= 20,000 CIRCUIT CALCULATIONS FIRST 10,000 AMPS @ 100% = 10,000 + 4096 OF "A" = (.40 x 24,010) = 9,604 + 100%OF "B" = (20,000) = 20,000 TOTAL WATTAGE = 39,604 WATTS DIVIDED BY 240 - AMPS CALCULATED SERVICE AMPS _. 165 1 1/2- VTR TO SANITARY SEWER ASSUMED EDGE OF WALL 2x6 WALL I. (FLOOR TO CEILING) USE 2 RED HEADS TO ANCHOR WALL TERNATIVE PROTECTION BARRIERIN.T PLUMBING RISER NOTE: ALL PLUMBING RISERS ARE TO BE VERIFIED w/ PLUMBING CONTRACTOR 'C VERIFY LOCATION WP IN FIELD GA ,I W DISCO�NNfET U I III/v\V BIBB I^1 INSTALL FAN 1..1 BOX PREWIRE INSTALL FAN WP p";OX PREWIRE GFI INSTALL FAN ----`j -------------- ----------- ---- BOX PREWIRE �- ---- ------------- - -— n i I _ I \\ r I I I I , I I I I I I I � CM I I I I I G I o GFI ,i ' �-. I FI 1 O 1- r- n 1- / \ FAN (�"(`1NSTALL.FAN j\\ PREWIRE ! ;! ' BOX PREWIRE 1 I , � I I I 1 I G GFI )220 GFIi `" `\ --- GFI GFI GEI - - ------ - *-- ---I--- `. 220 - - ISP - _---------- `. MICRO/ FOR D/W HOOD 1, GFl � CEN. OF WALL o W, 220 I - Z' Ire �l GFII- GFl I % ..,. .,:...,. I PE GFI @ ELECTRICAL ' W.H. 220 42" AFF PANEL 1 I I Lw) I,TTIC ELECTRIC 9 4y xlwy IF REQ'D BY CODE / or - no NC4y) z z o oW / w w w T � j GFI @ O O m C < GFI 42" AFF z m N w FOR GARAGE m G R DOOR OPENER O m H ------------------------------------------------ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 I I I I I I I I I I I I --------- ------ COACH ---COACT LIGHT LIGHT I DOOR / BELL I1 I WP fl ' GFI YYYY n \ n n u u COACI / LIGHT - .f''�"INSTALL FAN I"•�", BOX PREWIRE I I I I I I 1 I I , I I i A'I1 NOTE: KEEP COACH LITES OUT OF BANDING, QUOINS, AND ROUND COLUMNS WHEN POSSIBLE. REFER TO ELEVATION FOR TRIM. ELECTRICAL PLAN SCALE: 1/4" =1'-O" ALL ELEVATIONS ELECTRICAL NOTES. UNLESS OTHERWISE NOTED. 1. ELECTRICAL OUTLET HEIGHTS AS MEASURED RROM FINISHED FLOOR TO CENTERED LINE OF THE BOX TOBE: 16" AFF (GENERAL) KITCHEN 44" APE BATHROOM 39" AFF '.. LAUNDRY ROOM 36" AFF EXTERIOR WATERPROOF 12" AFF GARAGE GENERAL PURPOSE 42" AFF RANGE 2" AFF 2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE. 3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE FINISHED FLOOR. 4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST EDITION, AND 6th EDITION FBCR, ELECTRICAL CHAPTER 34 THRU43, AND BY A LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & ACCESSORIES. 5. SMOKE DETECTORS SHALL BE IN ACCORDANCE WITH FBC R314.1 AND LISTED IN ACCORDANCE. WITH UL 217 6. PROVIDE AFCis (ARC FAULT. INTERRUPTERS) COMBINATION TYPE INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT IN ALL DWELLING UNIT PER 6th EDITION FBGR E3902.16 ALL 15 AND 20 AMP BRANCH CIRCUITS ARE REQUIRED TO BE ARC FAULT PROTECTED. 7. CARBON MONOXIDE PROTECTION: CARBON MONOXIDE ALARMS OR DETECTORS SHALL BE INSTALLED INALL DWELLING UNITS IN ACCORDANCE WITH NFPA 70-14. SUCH DEVISES SHALL BE LISTED BY THE APPROPRIATE STANDARD, EITHER ANSI/UL 2034, STANDARD FOR SINGLE AND MULTIPLE STATION CO ALARMS OR UL 2075, GAS AND VAPOR DETECTOR SENSOR, ACCORDING TO THE INSTALLATION. 8. COMBINATION ALARMS: COMBINATION SMOKE/CARBON MONOXIDE ALARMS SHALL BE PERMITTED IF EACH MEETS THE APPLICABLE UL STANDARD, 9. KEEP ALL SMOKE DETECTORS MINIMUM OF 36' FROM BATHROOM DOORS 10. IN NEW CONSTRUCTION, SMOKE DETECTORS SHALL BE HARDWIRED INTO AN A/C ELECTRICAL POWER SOURCE AND SHALL BE EQUIPPED WITH A MONITORED BATTERY BACKUP. 11. BATHROOM EXHAUST FANS MUST VENT TO THE EXTERIOR OF THE BUILDING, VENTILATION TO ATTIC SPACE AND SOFFITS IS NOT ACCEPTABLE. 12. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85 dBA AT 10 FEET, AND EITHER HARDWIRED OR OF THE PLUG-IN TYPE. THE EXIT ALARM SHALL PRODUCE A CONTINUOUS AUDIBLE WARNING WHEN THE DOOR OR WINDOW ARE OPENED. 13. ADD GFCI PROTECTION TO RECEPTACLES IN KITCHENS, LAUNDRY ROOMS AND UTILITY ROOMS OF DWELLINGS WHERE. INSTALLED WITHIN W IF THE OUTSIDE EDGE OFA SINK, THIS WOULD INCLUDE THE RECEPTACLE INSTALLED FOR A WASHING MACHINE. RECEPTACLES OUTLESTS SHALLNOT BE REQUIRED ON A WALL DIRECTLY BEHIND A RANGE OR SINK TO FULFILL THE REQUIREMENT FOR AN OUTLET EVERY 24". THE WIDTH OFTHE SINK OR RANGE IS NOT TO BE INCLUDED IN THE SPACING OF THE OUTLETS UNLESS THE DISTANCE FROM THE SINK OR RANGE IS GREATER THE 12" FOR STRAIGHT COUNTER TOPS AND 18" FOR SINKS AND RANGES INSTALLED IN CORNER COUNTERS. PER 6th EDITION FBGR E3902.6 14. IN ALL AREAS SPECIFIED IN N.E.C. 210.52 AND IN 6th EDITION FBGR E3901, ALL 125 VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT RECEPTACLES. PER 6th EDITION FSCR E4002.14 AND NEC 406.12(A) 15. RECEPTACLE OUTLET IN GARAGE FOR GARAGE DOOR OPENER TO BE GROUND FAULT CIRCUIT INTERRUPTER (GFCI). 16. ALL PERMANENT INTERIOR AND EXTERIOR LIGHT FIXTURES TO BE 100% CFL BULBS ELECTRICAL LEGEND SMOKE DETECTOR SINGLE POLE SWITCH CARBON MONOXIDE/ $2 DOUBLE POLE SWITCH SMOKE DETECTOR COMBO UNIT $3 THREE-WAY SWITCH %'�� FLOOD LIGHT $4 FOUR-WAY SWITCH lJ J $DM DIMMER SWITCH FLUORESCENT LIGHTING CEILING MOUNTED FIXTURE _f] n 171 TRACK LIGHTING SCOUNCE ( WALL MOUNTED) FIXTURE 110 VOLT DUPLEX OUTLET o CEILING FAN 4b 110 VOLT SPLIT SWITCHED OUTLET GROUND FAULT INTERRUPT rn ' 2 DOOR BELL CHIMES �,I. W WP WATER PROOF W/ GROUND FAULT U 220 VOLT OUTLET OO — DOOR BELL SPECIAL SERVICES OUTLET Dp P DISPOSAL TV❑ T.V. CABLE OUTLET LO DISCONNECT SWITCH TELEPHONE CABLE OUTLET SP PREWIRE SPEAKER ® RECESSED LIGHTING J JUNCTION BOX WATER PROOF RECESSED LIGHTING T� THERMOSTAT BATH FAN Q LOW VOLTAGE LIGHTING BATH FAN W/ LIGHT I C INTERCOM SYSTEM ® L.E,D. DISC LIGHT ® GARAGE DOOR PUSH BUTTON OPTIONAL OVERHEAD SERVICE VERIFY FINAL AMPS NEEDED SAME AS UNDERGROUND WITHELECTRICAL CONTRACTOR 200 AMP SERVICE 200 = 210 COPPER OR 4/0 ALUMN. IN 2" CONDUIT ' METER MAN DISCONNECT 200AMP A/C DISCONNECT UNDERGROUND SERVICE POWER COMPANY O # 14 COPPER TO LIGHTS AND OUTLETS ryP ELECTRICAL #12 COPPER TO APPLIANCES AND GFI PANEL # 10 COPPER TO WATER NEATER # 8 COPPER TO RANGE INTERSYSTEM #8TO HVAC BONDING TERMINATION #4 GROUNDING WIRE WITH CODE APPROVED CLAMP TO EITHER a) APPROVED GROUNDING ROD W/ MIN. 8' DEPTH b) BONDED TO CONTINUOUS FOOTING STEEL ELECTRICAL RISER NOTE: N.T.S. ELECTRICAL MATERIALAND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS AS STATED ON STRUCTURAL NOTES SHEET LOCAL CODES AND THE LOCAL POWER CO. 0 Ic I Lo -8m�" f09Rg IO�gm_E a " n>e Q gd N W g E4, w a J K; cc W. ro CH m o m E3@ OLL O O� se9 Z r � '�� WWW.F03eV6.COM ❑ ❑ ❑ (D M Z� o z M O z � ¢ e J a — YQQ v (D o E O W Q I/) r m N O ;gym U B cN E AWA\ DAMS HOMICS Room FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE VI Job Information.. d m O9 a 0 L W D LO m E 0 N f0 m Gf o m 2:F—`iVM LO ti a 0 J W M o U7 LL jModel Name / Number: 1820 C? VI Plan Issue Date: d Wednesday, March 11, 2020 KA PROJECT NUMBER: 20-1548 Sheet: /N Of: 0 (ice N ELE r� TOP IF E 0 co FIN FIN. BEARING Ca ENTRY Da OF BLOCK FIN. FLR. TOP OF BLOCK 48" Off RIDGE VENT 12 0 SMOOTH DECORATIVE BANDS RETURNS 2'-0" SEE FRONT ELEV. FOR SIZE & STYLE 48" OFF RIDGE VENT 0 33/2 SH W'DOW HEAD HOT w LITE TEXTURED DECORATIVE 0 CEMENTITIOUS COATING . FLR. 25 SH DBL 25 SH 25 SH 2868 FRENCH DOOR REAR ELEVATION SCALE: 1/4" =1'-0" ■ co iD DEL 25 SH 25 SH 48" OFF RIDGE VENT DBL 25 SH TOP OF BLOCK 0 ao LITE TEXTURED DECORATIVE CEMENTITIOUS COATING FIN. FLR. -� RIGHT ELEVATION "By' - SCALE: 1/4" = 1'•0" 12 48" OFF RIDGE VENT ® 6 TOP OF LITE TEXTURED DECORATIVE CEMENTITIOUS COATING SMOOTH DECORATIVE RAISED BANDS RETURNS 2'-0" SEE FRONT ELEV. FOR SIZE & STYLE FIN. FLR. LEFT ELEVATION "B11 SCALE: 1/4" =1'-0" VENTILATION CALCULATION Formula = 3F / 300 / 2 * 1" = net sq inches of venting needed equally for Intake and exhaust Soffit product provides 4.12 netsq in/sf Ridge vent provides 18.00 net sq in / If Off ridge vent provides 138.00 net sq in/sf Overhang distance. : 1.33 ft S.F. of Area to be vented (SF) - 24¢9 s.f. Total needed for exhaust for upper 1/3 578 net sq inches Total needed for Intake (soffit area, lower) 578 net sq inches Number of Off Ridge Vents for upper 1/3 needed 4 ' LF. of Ridge Vent needed (can be used in combo with ORV) 32 Lineal Feet of Soffit" needed to meet required' 305 Lineal5 S.F. provided by plan Z0g OVERHEAD DOOR S.L. AND 16" H TRAN. ABV. CEMENTITIOUS. COATING RAISED BANDS DOOR STYLE MAY VARY REFER TO SPECIFICATIONS FRONT ELEVATION "B" SCALE: 1/4" =1'-O" ;71,;» /It�l . _.t lillif gE� NNOD y 00 � $;O d Qo.1�m ik tk tk mks da D`4ommd a Q�s Wa It a WQ. Of a� Qs 3 Z Y F" N�mY m m 0 IL m In a °� � �� vnvw.FDsnvs.cory ❑ � ❑ w m Z N 0 '^ Z m o o C Q O 3 0_ LL ZQ � �0 a. _ o E Q uew Oro o I E ®� 31) > o ?n a;m N by N a ® DAMS_ HOMES N C FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 Ti t DIVISION LOCATION: z PORT ST. LUCIE Job Information: 1..1� 0 0 zGLO W N 3) in ai z�� i V m r- a - pZiLLJ LIDtt2 J m U) (n VI Model Name / Number: 1820 Plan Issue Date: Wednesday, March 11, 2020 a VI KA PROJECT NUMBER: u Y 20-1548 T rn Sheet: Of: 0 N ELEVATIONS A W ALTERNATE SPAN RATED 32/16 SHEATHING MAY BE USED (32/16 IS THE SPAN RATING. THE SHEATHING 20'-O" MAX 20'-0" MAX THICKNESS IS 15/32".) IF 15/32" IS SEE DET.TB03 USED, THEN THE ALTERNATE BLOCKING IS NOT REQUIRED AT HIP TIONS G.C. TO PRO BLOCKING' W/ APA REI FOR SPAN 1 7/16' OSB SEE"HIP/R BLOCKING" 0 w 2- s EQ. W R CONTINUOUS BOTTOM CHORD v BRACING 2 X 4 MIN. SEE DETAIL T804— — — — " X" BRACE SEE R )VIDE4 DETAIL T301 a '0 COMPLY :OMENDATIONS— ATING OF - Q DGE > DETAIL Q Z M 4 v Q Q O � � a � O 7 g TOP & BOTTOM CHORD GABLE END BRACING @ 4'-0" O.C. MAX FOR FIRST (4)ROWS OF TRUSSES NOTE: 1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING CUT SHEETS FOR ADDITIONAL PERMANENT BRACINGTHAT MAY BE REQUIRED 2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. TBO5 I REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN NTs 4 Ff. ------------------------------------------------------------- 1 4 Ff. I / O3 1 1 2 1 1 I O 'OO' / ------------------------------------------------ 1 / � l 5 7. 4 Fr. (1 5 F�. 4 Fr. W_________________________________ _ ___ _-_- 1 1 1 1 a Fr. i O O `♦ 4 Ff. O Q 4 F. ROOF NAILING ZONE DIAGRAM AO NAILATBASE 2ROWS @4"O.C.WIMCOMMON NAIL ROOF NAILING SCHEDULE: O NAIL AT TOP PLATE TWO ROWS @4"O.C.W/8dCOMMON NAIL NAILING ZONES (SHINGLE AND TILE) O NAIL OPENING PERIMETER @ 3" D.C. W/8d COMMON NAIL ZONE 1: 8d RING SHANK NAILS @ 6' O.C. ON EDGE AND W O.0 IN FIELD O NAIL INT. AT 3" O.C, W/ 8d COMMON NAIL ZONE 2: 8d RING SHANK NAILS @ 6' O.C. ON EDGE AND B' O.0 IN FIELD ZONE 3 8d RING SHANK NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD O STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. (NOTE: IF 5/8" PLYWOOD IS USED; CONTRACTOR MUST USE 10d RING W/Sd COMMON NAIL SHANK NAILS) O PLYWOOD SPLICES @ HEADER • NAIL SHEATHING TO HEADER NOTE: W/ 8d COMMON NAILS @ 4" O.C. 7/16" OSB MIN. (SHINGLES) SPAN RATED 24118 GO (2) 8d NAILS @ 3" O.C. TO EACH TRUSS END OR @ VERTICAL OR ROOF SHEATHING: (APA RATED EXPOSURE 1) 15/32" OR GREATER MEMBER IF GABLE END CDX PLYWOOD (TILE) NOTE: Sd NAILS FOR WALL SHEATHING MUST BE MIN .131" X 2 1/2' SHEATHING MAY BE INSTALLED VERTICALLY OR HORIZONTALLY, ATrACH DO NOT OVERDRIVE NAILS: FASTENERS SHALL NOT PENETRATE SURFACE PER NAILING SCHEDULE. PANEL EDGES WILL NEED TO BE ATTACHED TO MORE THAN 1/8", STUD AND OR BLOCKING AT ALL EDGES. A MINIMUM 1/8" SPACE IS ALTERNATE PANEL WALL SYSTEM (PRFiAB) ATTACH WALL SHEATHING W/ RECOMMENDED BETWEEN PANELS AT EDGES AND END JOINTS TO ALLOW 160A x 13/4" STAPLES & 2" O.C. ON EDGE & 4" O.C. IN. FIELD, FOR EXPANSION. FASTENERS SHALL NOT PENETRATE SURFACE MORE THAN 1/8" 15/32" OSB (2)- 2x TOP PLATE 15/32' OSB EXPOSURE 1 EXPOSURE 1 BEYOND SHEATHING SHEATHING II II II SOLID 2x 1 11 II II I BLOCKING @ ALL L.UII rOPENING II II I SHEATHING TDII EDGES (SEEII C II I I SECTION X-X) N - PROVIDE I II III II IBLOCKING ASI ? REQUIREDPER - II If II I II I II w = a�l- SECTION X-X IF NOT FULL 11 11 II _ _ - HEIGHTSHEET II II III II II II II II III ,r, _ _ ,r_ 11 II II II 1 2x STUDS = W W p ? ~ � 0 II II II II III III it I II I I I II II If it II II 11 I BEYOND. MA It p of w %a m W it 11 SEE PLAN o 0 rr __11_ _u_=_ II II III II II i I 2z TnwpO © LOOR SYS-r II 11. It I 1 I 11 11 II 1a N LL IL_ � y�l I� JIB I J1 I W L SHEATHING 2X4 P.T. BASE 2x RIBBON PLATE BEYOND OR VERTICAL HORIZONTAL SEE PLAN BLOCKING WAIL ELEVATION DIAGRAM BETWEEN "S"=NAIL FLOOR SPACING SYSTEM AT ALL PANEL BLOCKING LOCATIONS MIN 2 X 4 #2 SPF 8" /8" TURNED VERTICAL W/ 7/1SD FLITCH PLATE TO W/ (2)12d TOENAILS EA_ END. NAIL I 41. I I FLITCH PLATE TO VERTICAL S 12" W/ (4) 8d NAILS - ° (2) 8d NAILS @ 3" O.C. S 12' ALTERNATING STAGGERED SINGLE NAIL EDGE SPACING DOUBLE NAIL EDGE SPACING V BLOCKING SECTION X-X "CONTRACTOR TO INSTALL EITHER HORIZONTAL OR VERTICAL BLOCKING AS SHOWN. BOTH ARE ADEQUATE T11313 I WALL AND ROOF SHEATHING INSTALLATION AND NAILING SCHEDULES N•r.s. C CONNECTOR SCHEDULE FOR: ADAMS HOMES - 1820 ELEV B TRUSS ID BEARING TRUSSACTUAL CONNECTOR ID CONNECTOR UPLIFT FASTENERS NOTES POINT UPLIFT DESIGN RATING CS-05, CIV -CSV, E7,i L/R -307#or less HETA16/PER TRUSS MFG 1810# (9) 10d x 1-1/2" E7VP, H7, H7V - CIP, E3, H3 L/R -246#or less H10A PER TRUSS MFG / 1040# (18)10dx 1-1/2" . a A(Yl AU6,-�t)9t AdO 19(14 L / R - 804 # or less HETA36 / HETA16 1810# / 1810# (9) 10d x 1-1/2" ' (9)10d x 1-1/2" s L/R -694#orless HETA16/H10A 18109/1040# (9)10dx14/2" 1i r (18)10d x 1-1/2" / L/M/R -932 #or less HETA16/H10A/HETA16 1810#/1040#/ (9110dx11/2 10d 1810# (18) x 1-1/2" (9)10dx 11/2 " (9)10dx11/2 I( .: '.L/M/R -655#or less HETA16/HETA16/H10A 1830#/1810#/ (9)10dx11/2 ; 1040# (18) 10d x 1 1/2' rt. (9) 10d x 1-1/2" ( ' ATY7 MOM/R -715#or less HETA16 /(2)MTS12/(2)MTS121 1810#/19809/ (28)10d A11/2 HETA 16 1980#/ 1810# (28) 10d x 1-1/2" (9)10d x 1-1/2" e u ' (10) IOd x 1-1/2" A08 L/M/M/R -1859#-or less (2)HETA16/(2)HTS20/(2)HTS20 1920#/2620#/. (48)10d x1-1/2" / (2)HETA36 2620#/ 1920# (48) 10d x 1-1/2" ' (10) 10t x 1-1/2:" TRUSS MANUFACTURER: PROBUILD DATE OF LAYOUT: DATE OF TRUSS: CUT SHEETS: 8127118' L = LEFT, R = RI GHT & M = MI DDLE BEARI NGS. BEARING LOCATIONS ARE REFERENCED TO TRUSS MANUFACTURER'S TRUSS DRAWINGS. , ALL CONNECTORS ARE SIMPSON PRODUCTS OR TRUSS BRACING AND ADDITIONAL ROOF INFORMATION SEE SHEET S-4 IMFIIIIIIIIIIIS "Lill M wqa IS npffffill� Iloa. F FIN In NJ ODD SPACE MCI re POOL mllLm FRAMED HIP CORNER I %kh �o r4i rim -1 I In SCALE: 1/4" =V-O" Vol SIMPSON- CONNECTOR SCHEDULE USP- CONNECTOR SCHEDULE MAAK TYPE CONWCTORSFASTENERS SPF . Syp CONNECTIX(a FASTENERS SPF 9YP O FRAME iO HETgi6W(B)IOOx1 VT CR HTAIBW(10)100x11?OR MASONRY IETA20WR)1Otlx1 U2" is HTA20W(1G)1O0%il/Y' Ian IM OFRAME TD FRAME H25Aw/)10)B0 NML9 5% 585 RF/AW (10J00 NML9 515 585 © FuUME TO H10Aw1119)ICUx112 1015 1040 RT19AvM71Od x 11W SSS IUD FRAME HlQAr2vd0Si 1 VFAT 2 PLY TRUSSES M RAID RIIS -2 W(I6)10tlx 11/TAT2 PLYTRMSES 035 Ina ° O FRAMETO M7S12w9I4110dx1IW(ATE),7WIpi e6o MTW'12 W(19110tlx111Y (AT IXTERIOR FRAME LOCATONINCLUDEM112a roENARa) t� LOCAnON INQUDEp IM TOENMLs) 1008 1105 OFRAME E TO MOT WR2)1 It NMl8 AND W ATA. W iT "'a MUGT5,A(2B)1Od NALSAADSM" A.T.R.W MASONRY EMBEDMENT./&MPSONSETEPDXY "M 12'EMBEOMENTWSIMPBON'BENEPDXY �30 4485 ID FRAMETO H1S20w/94)10dx11/2'(AT EXTERIOR 124E HTMOWPOIOtlx111T(ATEXTERIOR FRAME LOCATION NCLUE) 12dTOENAIl1 1310 LOCATION INCWDE (01ZETOEIZALB 1213 INN FRAME TO (2) HT820W(4MIOdx 1 W' IAT EXTERIOR 24� RI HTVRO W(4BHOd x 1121AT EXTEANw1 FRAME LOCATIN NCI4IDE R)12tl TOENAILS 2�0 LOCATION INCLUDE(6)12d TOENAILS TEA) 2570 3080 FRAME TO. HGT-2wl(18)10ENAILSAND(Z)5/6' AT.R. HIICaT2 w/(18110E NAILSAND(2)W A.T.R. © MASONRY WiTEMBEOMENTWSIMPSON'9ET' 18890 WITENMEgAEMW91MP90N'9ET" Ina 97M EPDXY (HOTS FOR34+LY) EPCXY(HJOT3FORSHPLY) OFRAMFTO H FGTRW H01/4°x3°SIDS WOOD SCFIEW9 3100 4725 RFUSN102)WIZIMODSCREWSAND MASCNM ANDW,11-I&YTITENWANCHORBOLTS (4)3/4'xTWEDGE4SOLT 71M (I) LGTZ wl (IO)1Od a1NKER5 Q FRAME TO aR11M'x 2-IM"TRENT 17W 2030 MASONRY TEN66 LO ©2 FRAMETO MASONRY/ (2) LDTZ W(M) 1 ad SIN6U5iS&(14) 191IMn1EN(2PLYTRLMB) 9500'M 4050-IS R) LUG32 W(32) 1dd SNxHis a(10) 1M"x 3" v,_i,BIXT(2PLYMuSS) 310pM 9100-M FRAME ORQ.af1BOSINKERSFORFRMJE(FA) 1240F S F OR(02) In SINKERS FOR ITT ME OEA) 3600'F 4620f O FRAME TO MASONRY/ M LTR3 W(24) 1/4' x 3"WS SCREWS aR) MP x 9' TITER(2 MY MUSS) 4]30.M 86]0tA (2) LUGT3 W(24) 1W x 21,T Mn WS SCRE& R) W. 5' MR PLY FRu33) & 70WM FRAME WON15INNKERSFOXFRAME(EA) SUIOF 01 OR OR) RM SHIERS FOR FRAMS MA BM 77 O BEAM TO HN10 OPT RUG110 W(15) latl&(10) 10d GWZ930 HM100PT 1404101F W(ZOO IW a(10) 106 G730% BEAM NAILS Omits I NML6 U#1s50 OBENITO HW100PTHUC4IUW(18)TREN G1,4500. HWIGOPTIbfIRFw/(2&019'x3° Damn MASONRY 1/4"4&4'&(10110INAILS 11(/1500 WEOTE4WLT&1010a NML9 UYB60 ©BEAMTO MASONRY/ HUMOPT HUO46WR) In NAILS (12)i14'x2W4'TITEN(TOMA3.) G#1Ma OICIND H0480PTNWSW(B)10tl NML9 a 31,1625 G#2018 FRAME OFIo2)IW&RDI0d DMRFRAWo LNOBO SYP-F U#1135 SYP-M (12)114'x23M"TAPOOMSHOMAS.) OR(121 iBddla)1OJ (FORFMME) W1030 SYPF WIND SYRM OFRAME TO (2) HETAIS O"M HETA20 1-MYW(10) IOax 1120R NR 10 IWO (2) HTA180PT(2) HTAiA 1-RYw/pq 101x 112 OR 1810 MASONRY 2-KY W (12)1& 2985 2385 2 !.Y W (141a3 MID WaM18W(a)IOd NMLSAND sI)i/4W 1/4' In 1110 WWM18 W(6)101 NA1_3AND(4)I/4IX1 SM' II45 I= TAPCONS WEDO&90LT ORUMETO MASONRY on HTW20 W(10)10d NMLSANO(4) 1M421A- OR TAPOONS IN 1110 TWM2OW11OIN N.MLSMNU(4) lflxl 3M WEDGE -BOLT 11M I= OFRAMETO P HIOSWOOMxl l2 MILSAM R)3,s w' >� MASONRY MAN'( O 810 TO DTR2W((I)10ilR'903 WODD Ol&R W(B)tM'%I TIT WSiBYANJD OFRAME M ASONom, BCAEWSAND (1)11T'6 AT.R SPORED W 1355 ZI45 SCREWSAND(1)1/Z'6AT.REMNDw/ iS10 1135 SIMPSON"SET SEE NOTE p4 SIMPSON'SEI" NOTE N4 HITS W OR) 16J YL 1W NAILS AND (1) HTTSSW OZ) 16dY 1/F NAILS AND (1) ROFMMETO MASONRY ATAEPDXIEDW61N1PSON'6ET 437$ Sna W"a A.T.R. EPDXIED w/SIMPSON"BET - WIN (SEENOIEMBELOW) IEEE NDTE tl46E1DYA TO HTT4 W(18) ISO IS 1W NAILS AND (1) W B NTTM W TS)16d XJ 1/T NAILS AND (11 ©FRAME MASONRY ATA EPOMEDwI61MP80N"BET' WO 4235 Wi A.T.D. IPOMED WI SINPSON"SET 4180 RME NOTE#d BELOW) (SEE NOTE #4 SELO OFMME TO FRAME HIOSWR4)100x1 tT rvuL3 910 LUOTiw/(ZJ)Sdx1112NAILS 175 Im 0 RUMETO HMOKTW(d)iN'k11/TSOSMOO 780 10tl RnmwlR1x112NMLR8 MASONRY SCREWS&(5) 1WI,2 lie TAMONS 730 (4)IMXIIM"TAPOCHIS 1395. 135 VGT W(15) 114W=0.R WOOD SCREWS OFRAMETO MASONRY (1) We'B A.T.R. EPDXIED W WAPSON"SET 3556 4WO W 12' MIN EMBEDMENT AME TO FRMMONRI, (2)VGTwl(M 1MN3' SON WOOD SCREWS O & W BBB A.T.R. EPOREO W W PSON 5170 71M 'SET W IT MIN. EM OMENT O FPAMEiO vrdr W nmlMxr soswvoD BCRexsa MOWAD825 WRO)1M"X2IIYBDB WOOD 320 4585 MUGT15WI2211Gd NNL88HTT45 WH61 FMME SCPEWSB(p R&"BAT.R 10tl NNL9&11)SM-BAT.R 4/80 0 MADE TO RT6 ) HTW(W) IWa 12 MAIN & 1375 5030 (2)Hrt4a W15Z118wM 1ITNMl3 FRAME I11 E(Pe AT.R (8EEMOTEM) 8(1) SIB'SAT.R(SEE MOTEM). - San neueoe, °rwlxermw umeR. i CONNECTALL FLODR'IHV'S6E5 TOINTEPoOR BEAPoNG WOOD WALLS/BFAMBw/RI IMFOENAILS. 2. ALLTRUWTOMUWCONNECTIONSME PROVIDED SYMMS MANUFACTURER, UN.O ON PLAIN, 3 D.C.MAY USE EITHER a1MPSON OR USPIDMNECTICII SEE FARING PLAN FOR CONNECTOR CALLOUT. 4. FOR SINME PLYMUSSM, SCAT DIN FULL. NEI041TsY v7- 'TOTRUOS VERTICALW'EB W(Z) ROAr OF In NAILS 0 WO.C. STAGGEAED, 6. MINNM&r..REMSEMEM:VDEDMENTFORIR'AT.R. V MM MENTFO WA.7.R.B'EMB®MENTFM7MAT.RPFATSTPP, DEPTH IS FROM LOWER SLAB). 1 SCAB TRUSS CHORD W 4'021 SYP4(MATCH CHORD LUMBER SIZE) .1(2) ROM 1010E 4" FROM END 84' O.C. STAGGERED: CENTERATDONIECTWLOCATIONAS MUCHASMSSMLE. G) MINMALCONNECTORUNOONFRAMINGPIAN 1. CONNEOMm FORAl1ROOrirLOORTRUSSEBTOfAVONRYWAUAfUNTEL&ICFWALLBUNOONPIAN 2. CONNECRONAT 24°OR BT O.C. PENDING VERTICALS FORMJ_ 1L00RMUSSESPARIILLFLTOMA40NRY WEALS SEE DETAIL IR312/83.1 FOR NONE INFORMATION 3. CONNECTON FOR ALL HIP JPd2((COI3NEA JACIQTO MASONRY WALL3ICF WALLSM1INTELS OF I2)AT EAGTI 4. CONNECT ION FOR MIFY CORNER.O.C. TO VERIFYLOC LOCATION DOESON CONFLICT DOES NOT CONRJCTw7JI OFAPPLICSLE) LAYOUT SOFAPYAT APPLICABLE)LAYOUT S M I S. CONNECT ALL FIOOFlTRU88E3 TOINTERION BEAPoNG WOOD WALUBFAMS WI (2)1M TONMLS O MINMALCONNECTORUNOON~5NOPLAN I. CONNECTON FOR JKx4TRll99 TOWOODWALL aA BEAM. © MIMMALOONHEOTORUNOONFRNWNOPLAN 1. CONNECTON FOR PLLTRU99E3 TO1ME1T1OWEXIERIM BEARING WOOb wcllRsulu'1R vwue° ROOF FRAMING NOTES 1. SHINGLE ROOFING SYSTEM OVER MIN. 7/16" OSB ON PRE-ENGINEERED WOOD TRUSSES AT 2'-0" O.C. MAX (SEE PLAN FOR SIZE AND SPACING, SEE ARCHITECTURAL PLAN FOR TYPICAL ROOF SLOPE AND OTHER INFORMATION. 2, THE EXTERIOR CEILING FOR THE ENTRIES AND PORCHES SHALL HAVE 7/16" DEB EXPOSURE 1SHEATHING TO THE UNDERSIDE OF THE ROOF TRUSSES. ALL PANEL EDGES ARE TO BE BLOCKED SOLID WITH 2X4 #2 SYP WITH (3) 10d TOENAILS EACH END. THE SHEATHING IS TO BE NAILED WITH 8d NAILS AT 4" ON CENTER AT ALL EDGES AND THEN S" ON CENTER IN FIELD 3. FOR UNDERLAYMENT REQUIREMENTS SEE R905.1.1 - - - NOTE TO FRAMER --- IF ROOF TRUSS LAYOUT SHOWS TRUSS IDS, THIS LAYOUT HAS BEEN PROVIDED BY THE CLIENT/ DESIGNER OR ARCHITECT TO USE FOR THE DESIGN OF THIS PROJECT. OTHERWISE A GENERIC LAYOUT HAS BEEN E N DETERMINED, BUT PRIOR TO CONSTRUCTION OR TRUSS FABRICATION, FINAL TRUSS LAYOUT AND TRUSS SHOP DRAWINGS ARE TO BE SUBMITTED TO ENGINEER OF RECORD (E.O.RJ FOR REVIEW AND APPROVAL. AT THIS TIME THE E.O.R. RESERVES THE RIGHT TO REVISE THE PLAN AS REQUIRED PER THE REVIEW OF THE FINAL TRUSS LAYOUT AND TRUSS SHOP DRAWINGS, ADDITIONAL FEE'S MAY APPLY. STARTING CONSTRUCTION OR TRUSS FABRICATION PRIOR TO THIS REVIEW IS NOT ADVISED, AND THE E.O.R: IS NOT RESPONSIBLE FOR ADDITIONAL COSTS DUE TO REVISIONS OF THE PLAN. IF CONVENTIONAL FRAMING IS SHOWN, NO TRUSS APPROVAL IS REQUIRED, UNLESS LAYOUT IS REVISED W/OUT WRITTEN APPROVAL FROM FDS. FOR TRUSS BRACING AND ADDITIONAL ROOF INFORMATION SEE SHEET S-4 D METAL DRIP EDGE i C.M.U. OR ICF WALL 2 x SUB -FASCIA SEE TYP. WALL SECTION ALUM FASCIA 2X4 P,T. FASTEN TO C.M.U. W/ 11/2' LONG T-NAILS 0 2'-0". O.C. SECURE J-CHANNEL 0 12"O.C. CONTINUOUS VINYL G.C. SHALL VERIFY SOFFIT MATERIAL CAPACITY TO RESIST THE DESIGN PRESSURES SPECIFIED FOR COMPONENTS AND CLADDING WIND PRESSURE TYPICAL SOFFIT SUPPORT DETAIL 3/4"=1'-0" s 0 N 5 o V`. \. A I-1 aD 01 AA T�1'fL"SS bT ' 3 1 go N F 15 8 M to N aM10 10B000 '�$ �pJ Q tihi� IJiIJi LL Q SAG i �6mP Ip�9_ w .y I H � W`7'om° a M ( � �w Q a� �� a a w 2oS�� z � .qB ¢s mn5 3 � O 1 g 5.ai m`m ¢m� 8 gg m sMIER] 12 o ;.$s WWw FDSENG COM ❑ Cl ❑ P M Z N O P Z In Z au a o a � 1 — Y RaR ON y ' ' "+ 1 0 O IL O v o IXm uli U L° (mv E '- ixQ 0°5 nQ 4i pa 111 DAMS HOMES IIm116 FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE VI Job Information: O a z O O U1 W Y m m 1U � IU �� m� z — t• d 0 _/y5� /WZ)Lq o W V� VJ LO LL VI Model Name / Number: 1820 TT Plan Issue Date: Wednesday, March 11, 2020 VI i KA PROJECT NUMBER: x 20-1548 Sheet: ^ Of: ROOF PLAN D U LINTEL BEAM: = I I III I 1I- 1COURSE LINTEL BLOCK W/ 1 # 5 NON-SHEARWALL SEGMENT BAR & SWO PSI GROUT, MIN. 25" LAP (ACI 530) TYPICAL SHEARWALL SEGMENT ALL SHEARWALL SEGMENTS CONSIST OF A FILLED CELL EACH END WITHOUT AN OPENING BETWEEN. FILLED CELL: FILL SILK. CELLS WITH 3000 F.B.I. GROUT ONE #5 0 LOCATIONS SHOWN ON THE FOUNDATION GONG. SLAB SEE PLAN AND FLOOR PLAN. FOUNDATION PLAN MIN. LAP 25" (ACI 5301 FOR MORE INFO TOP OF SLAB 4 1+ MS021 TYPICAL SHEAR WALL SECTION N.T.S. TYP. TIE BEAM W/3000 P.S.I. GONG. W/1 #5 REaAR CONT. SIMPSON SP4 W/(6)-10d X 11/2 SP8 OR BPS FOR 2MI AND 2x8 WALLS c a DOUBLE 2x TOP PLATE I' STANDARD HOOKS SEE MS05 FOR MORE INFO TYP. FILLED CELL W/3000 P.S.I. CONC. ' W/1 #5 REBAR VERT,. INTERIOR BEARING WALL INTERIOR SHEARWALL EXTERIOR FRAME WALL S" C.M.U. 2"z #2 SYP/SPF P.T. W/ (3) 1/2" X S" "J" BOLTS OR (3) 1/2" X 6" EXPANSION ANCHORS OR (6) 3" X 1/4" TAPCONS OR 1': (8) 2 7/8" HILTI TD I NAILS 2x BASE PLATE SEE *:Fw . PLAN FOR MORE INFO MS03 FRAME (EXT/B RG/S H EAR) WALL TO N.T.S. MASONRY CONNECTION DETAIL #5 REINF. 20" MIN, LAP BAR #3 OR #4 REINFORCMG 1J BAR #a AA #41 AP SPI 1PS 25' MIN. LAP #5 STD. 90° HOOK #51 P PI a NFORcIrvGBAR ICE SCALE:1"=1'O"s 36" MIN. UAP I• #6 REINFORCING • GRADE 40 U.N.O. 96 LAP SPLICE MSO5 REBAR SPLICE DETAIL - GRADE 40 N.T.B. ATTACHMENT REQUIRE ENTS SIZE. TAPCONS SPACING 8 ROWS 2 x 4 1/4" X 2%- 12" O.C. 1 2 x 6 1/4" X 23A" 12' O.C. 2 2 x 8 1/4" X 2vA" 12' C.C. 2 NOTE: TAPCONS TO BE 4" FROM ENDS - FASTENING OF WINDOW TO BUCK RESPONSIBILITY OF WINDOW MANUFACTURER. PRECAST- ----- LINTEL i a i (2) 2X P.T. i BUCKS W/ 1 1/2" D.S.B. BETWEEN ; FASTEN PT i NAILER TO MASONRY IF DOUBLE 2X NAILER IS USED, USE 1/4"X 4 1/2" TAPOONS. SEE OTHER NOTE FOR SPACING REQUIRED MS11 I 2x BUCK DETAIL N.T.B. H N a ALL ELEVATIONS O O wl FseAw AT TOP Pool11 R6eC W/1' C1L4R �3f •V .: �J.; swan 9 wmiR AT eo,1.1 c OP unru C rfr 801FON RRNGAGIN6 T'M'GGN4 ITGYIC01 N LM1GL rcAwtee e'rronNq,rumW TYPE DESIGNATION r. vu.m wmf swaTr r u . uN `— awnrtr ca +e waeAsw, AT O1'. oP LM4 OAMi 81`16-18I /IT Non,u", rroi+ J j NoM� �ea4NhTT CMN IN41GBAN AT TOM MATERIALS L. fc precast lintels = 3600 pal, 2. Pc prestressed [Intel,=6000 pal. 3. Pc grout= 3000 psi w/ maximum 3/8" aggregate. 4. Concrete masonry pntta (CMU) par ASTM ego W/ mlNmum net area COmluessive Wendh - 1900 W. 5. Reber pmviJed In pecast [Intel PerASTM A615 GIM. 6. Field refer Per ASTM A615 GR40 or GRBD. Presreselag strentl par ASTM A416 grade 2TO lav IdaMWn. 7, 7/32 wlm per ASW A510. S. Mortar per ASTM 0270 type M N S. GENERAL NOTES 1. Provide full molar head and bed JOlnts. 2. Shore filled imals a a required. 3. Installation of I1se1 ants: comply With hie af,hrowum, and/or awrtural drawings. 4. Unlele are manufeclured wet S1/2" Ieng r,drT, M the. ends to accommodate "Mae call reitfoncing and gmufal. 5. All IImels meat or exctica eed L/360 verl detection, except i[Mee 17'4"and IOP90( With a naninal height of S' meet or exceed L/180. B. Rottwo field added labor to be located at the bottom 0/ the lintel cavity. 7. 7/32- clameter Ware stirrups are welded to the concern creel for mechanical anchorage. 8. Castinconcrete may be pmvidled In composts Ilmel In lleu of conaem masonry units. 9. Safe 100 TBthSS based on rational design analysis per ACI 318 end ACI 530 10. Lintel Oin• depths are called out on lintel plan. II corducal installs a deeper Ihttel than Indicated On the Plan, doing this Increases tie strength of the IIntel and Is approved without enginmdng letter, if a mnel time Is Totalled contact FOR for ap anal. _SAFE LOAD TABLE NOTES 1. Ali values based on miKmum 4" bearing. Exception' Sete Ieeds for unfilled Ilntels must be reduced VY 20%If bearing length Is less than 61/2". Safe leads for all recessed lintels, based on W nominal beading- 2 N.R. = Not Hexed. 3. Safe bads as total suPWIMPO"d albwable load on the Section specified. 4. safe loads based on grade 40 Of grade 60 field Taber. S. Additional latent load cePatlty can be detailed by the dowel by providing addlonal reinforced masonry above the precast lintel. 6. One #7 mass may be supedo fed for tWO #5 rebars In 8" Insole Only. 7. The deslgnef may evaluate amcontretod load. ham #e ale load tables by calculating the maximum reWStIng moment and sheaf at cl w Iran the We of support. 8 For composue ATOM heights not shown, use Safe load from next Iawer.heigM. 9. At sane loads In urns of pounds per finder fooT. 10 PRECAST'U" LINTEL W/ 30ODPSI CONC. GROUT SHALL BE FLUSH i AT OPENINGS SEE GENERAL CONCRETE WITH TOP OF WALL i - LINTEL SCHEDULE FOR REQUIRED REINFORCEMENT , HURRICANE R R B ANCKWS SO" STD. 90 HOOK (TYP.I -i HOOK ' 0 C 0 4W r' fy R o REBAR ON BOTH SIDES SM. 90 DEGREE ANGLE am P.S.I. r OF OPENING U.N,O.. GOING. W/1 #5 D TYP. BOND BEAM i REBAR e" z S" x JLW K.O. PROVIDE KNOCK -OUT LINTEL BLOCK BLOCK FOR FIRST Rll W/3000 P.S.I.. • COMPLETE CMU COURSE CONIC. W/1 #5 DIA. r - BELOW SILL &FILL SOLID REDAA I • W/ (1) #S BAR FOR ALL i WINDOW OPENINGS 6%6" AND LARGE INDICATES FILLED 'p S. x 8" X 16, CELL FROM FTG. TO , CMU U,N.O. BEAM WITH 1 #5 t BAR MIN. I r TYP. DOWEL 25" MIN. LAP (ACI 530) , r i I i I" SEE ToUNDATION PLAN I, - SEE FOUNDATION 4 FOR LOCATIONS fi i PLAN C C r MS01 BLOCK WALL REINFORCEMENT N.T.S. t I Is' cal %; N jL r L , i j w 2�j9 �pp 1 g' AT Icy N W 3 ER D otim G ¢ Ga � r- er,ea}§ �X ¢V W 5 w � al LL aidt» 3a 1 we nfi M gtrI a O ° MINI ¢ 000 W, mga ' 03 Ell ?na d a • E R IL® Ci C 0 to T, 2 W t°- g 'a ° W WI.FDSENG.00M 000 ti Z N n7 m m or Z Z ao (a ) � N 4�(D A W m � W t c m 'G1aJ x , F V � N x OP o0 a them sm p AL DAMS HOMES FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZIE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. L.UCIE Job Information: y `y I O a 2!C W m Y m � N to O—J W�/� //�A LL W VJ VJ to Model Name / Number: 1820 Plan Issue Date: Wednesday, March 11, 2020 KA PROJECT NUMBER: 20-1548 Sheet: S 1 70, LINTEL PLAN FILE, t 2x6 #2 SYP P.T. D SIMPSON HETA 16 W/ (2) Wx5" EACH END SEE FLOOR PLAN WEDGEANCHOR 0 FOR BEAM SPEC. OVERHEAD SECTIONAL DOOR TRACK W/ 3/8" X 1 1/2" STEEL LAG BOLT cr'^. U 0 W/ WASHER. MIN. 6 PER J 3 v TRACK TO JAMB.15- (5) 1/2" DIA. x 8" 1/2" X 8" A.B. W/2" o n 0 "J" BOLTS WASHERS SET IN FILLED CELL W/ #5 TYP: FILLED CELL ;; „ 2 VERTICAL MIN. 5 PER JAMB. b SECTIONAL ® OVERHEAD „ N DOOR CONT. P.T. #2 v WOOD SYP 2„ X 6,, TRIM 2"x6" P.T. WOOD JAMB V ,, '„ �; . • c ,.•a....?� ��d N B `• • di N dam,. . n • E ������. " •, •♦E O rt y+. DOOR AND CONNECTION PER D GARAGE DOOR MANUFACTURER GARAGE SLAB = C �' * - _ 1 TYP. GARAGE DOOR TRACK MOUNTING DETAIL 3 2- OF i= # . r w =-, L(;��° ° ° �i CDC NOTE: DETAIL CD22 / 5-2 MAY BE SUBSITUTED FOR THIS DETAIL• UNLESS NOTED OTHERWISE .� a 3 MS12 OVERHEAD GARAGE DOOR ATTACHMENT N.T.S. CD21 ENTRY CMU COLUMN/BEAM N.T.S. a v v n 0 c H ffip IN to Z E E �P. 00 g� PEp 9 f q 0N ti'y g6g U o�rn W W W to OB @mg BLOWN -IN R-30 INSULATION PER FBC g§ s W 0 a: a F AND ENERGY FORM SUBMITTED WITH v BLOWN R•30INSULATION PER PERMIT APPLICATION PROVIDE BAFFLES O ~o g $ §, 9 -IN FBC AND ENERGY FORM SUBMITTED 12 AT EAVES (FOR VENTED ATTICS) FIBERGLASS SHINGLES OR 'B it n W E m m ro a °./ 12 WITH PERMIT APPLICATION � g Z _ e � < � p $a Hat d a 8 ' PROVIDE BAFFLES AT EAVES SEE PLAN TILE ROOF (PER ELEVATION) , OVER APPROVED UNDERLAYMENT 8 E O S $ 2 ¢ 0 7 SEE PLAN (FOR VENTED ATTICS) PER FBCRRUCTU OVER APA o F �' �� III ' FIBERGLASS SHINGLES OR PRE ENGINEERED WOOD RATED STRUCTURAL SHEATHING w � -www.FosErvc.com ❑ ❑ ❑ TILE ROOF (PER ELEVATION) TRUSSES @ 24" O.C. (SEE STRUCTURAL NOTES FASTENED TO TRUSSES PER ROOF i OVER APPOVED UNDERLAYMENT ' PER FBCR 905.1.1 OVER APA Y ' NAILING SCHEDULE) /7 (9 0 /\V1�/I\ Z ry o PRE-ENG. WOOD RATED STRUCTURALSHEATHING —TRUSS ANCHOR (SEE ;� m TRUSSES @ 24" O.C. ( SEE STRUCTURAL NOTES FASTENED TO TRUSSES PER RCAF j��, SEE PLAN FOR — _ _ _ _ _ _ BRG. HT. 5 Z a Q NAILING SCHEDULE ;. 1 2" D / DRYWALL a -TRUSS ANCHOR (SEE PLAN) TO BE INSTALLED ON OUTSIDE FELT PAPER E • ° TRUSS PLATE ETAL DRIP EDGE $ c r r ■ — Y 11 .I 4 1/ 11 1/ 11 ll 11 11 1/ 1( 11 FACE _ _ - '- 3/4 P.T. NAILER ;; zx suBFAsaA (TYP.) FRAME FOR BUILT-UP CORNERS min (3) 2x4 OR 8 to O Jv v ',6 SOFFIT. SEE ARCH. 1/2' DRYWALL 4x4 w/ 2x4 POST UNDER '" +� w f6 t METAL DRIP EDGE r PLANS CURTAIN NAILER r 8x M. 2 X 4 P.T. PLATE END OF SUPPORTING BEAM. 0 U 1/2" DRYWALL CONNECT ALL STUD 2X SUBFASCIA 1 x 4 P.T. C°1 WINDOWS ELBLO0. LINTEL BLOCK 1 x 8 P.T. @ S.G.D. n O,H, W/ (1) #5 DIA. REBAR & „ KEEP IN 3/4" FOR SHEATHING NAILED w/ 8d NAILS @ 6 AND LATH WITH FINISH D.C. E o, V) c m W TO TOP16dTO PLATE WITH (4) 16d TOENAILS ��T. SEE ARCH „ u SEE �Ey 3000 P51 CONCRETE (TYP.) ALL SIDES (TYP.) FRAME FOR COR- o l!1 tipM o PLANS PRECAST"U" LINTEL .+ OO !���° NERS FOR NON LOAD " w 0 0 rr , 1/2" DRYWALL _ SEE PLAN FOR HEADER SIZE SEE SCHEDULE v , ✓o °a o a\o�` BEARING SIDES NAILED `I <\ w/ 16d NAILS @ 8" O.C. U N o 0 ovvfv Oo = c v�.o 0 \` amoao am OPTION: 15/32" OSB EXPOSURE 1 ON O.H. 1/2" X 8" J-BOLTS MAXIMUM OF (3) - 2X PLATES MAY BE EXT. WALL W/ ALL EDGES BLOCKED. (1) CENTERED ` �' (TYP.)4 COURSE HIGH A.F.F. . DAMS HOMES ADDED BELOW THE HEADER W/ EACH SEE ELEV. SEE T813 FOR NAIL ATTACHMENT. SIDE w/2" WASHERS , CMU BASE FILLED w/ CONIC H v PLY ATTACHED W/ (2) ROWS OF 16d (OPTION) STAPLE: 16 GA. 1 3/4" STAPLE 0 2" O.0 EDGES AND FIELD. Typ- w/ (4) VERTICAL RENF w/ (TYP.) � NAILS AT 8" O.C. NOTE: 44" MAX. SILL ON n FILL CELL -(1) #5 DIA. HOOKS INTO FIG & AT TOP ate° FLORIDA CONTRACTORS LICENSE N0. CRC1330140 ALL BEDROOM WINDOWS. n REBAR W/ 3000 PSI CONC. ALL LOCATIONS PLAN Al -Al OF COLUMN d 3000 GULFBREEZE PARKWAY VINYL FRAMED WINDOW w/ SCREEN u SHOWN ON FOUNDATION or GULFBREEZE, FLORIDA 32563 (G.C. TO VERIFY W/ FLOOR PLAN u &FLOOR PLANS u W n DIVISION LOCATION: LOCATION OF OPENINGS IN N EXTERIOR WOOD WALLS. IF NO ., R PLAN SIMPSON LSTA30ONFOR a PORT ST. LUCIE OPENINGS ARE INDICATED, FULL w/11-10d TO BEAM SPEC. ♦ Job Information: STUDS ARE REQUIRED). Ill, & TO FRAME BELOW NOTE: 44" MAX. SILL MGT. ON r ALL BEDROOM WINDOWS. VINYL FRAMED WINDOW_ W/ SCREEN WINDOW STOOL CEMENTITIOUS DECORATIVE FINISH 7/8" THICK PER ASTM PER SPECS 'I PRECAST CONIC SILL ro C-926-98A •", PAPER BACKED FOIL R4.1 M 2X STUDS (SEE FLOOR PLAN FOR INSULATION AT CMU BLOCK WALL MORE INFORMATION), SEE TEI 1/2" DRYWALL PER FBC AND ENERGY FORM V EXTERIOR FINISH - SUBMITTED WITH PERMIT m a ON SHEET 6 FOR NAILING INFORMATION FOR APPLICATION (SEE ELEVATIONS) 8 Z = � � R-13 INSULATION AT EXTERIOR WALLSHEATHING. WOOD FRAME WALL PER FBC P.T. 2X #2 SYP. BASE PLATE 1 x 2 P.T FURRING FTG. DOWEL #5 DIA. REBAR 1 x 4 P.T. 17" IN CONCRETE - 25" � `� N y M AND ENERGY FORM SUBMITTED wJ 1/2 x 8 A.B. (OR 1/2" x 8" TITEN WITH PERMIT APPLICATION BASE NAILER EXTEND (AC[ 530) ABOVE SLAB. ALL LOCATIONS SHOWN SIMPSON HETA20 ' ' BUILT-UP CORNER MIN 2x4 E \ +a' m cu HD) w/2" WASHER AT 32" O.C. WOOD BAS TO COLUMN Al , Al (3) / Lo c 0 3 MIN. FROM END -SEE W507 WOOD BASE ON FOUNDATION PLAN POOST10d OR 4x4 POST w/ 2x4 UNDER � a) FOR TERMITE SHIELD E SEE FOUNDATION PLAN , FOR FOUNDATIONSEE EACH END OF BEAM ' � � � U � � � FOR SLAB INFORMATION TOP OF SLAB _ _ SLAB ORMATIONN _ TOP OF SLAB , — - — NOTE: , , 2 X 4 P.T. PLATE '= O JujZ) M o ,, . ... , , -., _ BOTTOM STRAPS MUST BE N J m \ ro * ^� " �_ �, * ;° INSTALLED ON INSIDE OF I . GRADE GRADE COLUMN. DO NOT BEND,,, vKr vv ♦ Model Name / Number: _ c STRAPS UNDER PLATE. v vrq ev 1-,,v F 1820 3 0 ^� PLACE STRAPS IN FILL ; a v v Cq{',V, ,' Y COMPACTED o 'SEE PLAN FOR CELLS w/#5 REBAR a r „ :• (TYP.)4 COURSE HIGH CMU BASE ♦ Plan Issue Date: FILL 1 , c� : RE -BAR QUANTITIES . FILLED w/ CONIC - SEE PLAN FOR Wednesday, March 11, 2020 r ; SIZE. TOP OF COLUMN BASE - SEE FOUNDATION PLAN 16" SEE PLAN _ FOUNDATION 2'-0" AFF g v ♦ KA PROJECT NUMBER: {SEE FOR FTG REQUIREMENTS PLAN p 20-1548 Y NOTE DETAIL CD21 j S 2 MAY BE SUBSITUTED FOR THIS DETAIL - UNLESS NOTED OTHERWISE T o Sheet: �_� Of: CD22 ENTRY CMU COLUMN BASE w/ FRAME ABOVE N.T.S. WS02 TYPICAL WALL SECTION EXTERIOR FRAME 3/4"=1'-0" WS01 TYPICAL WALL SECTION - 8" CMU 3/4"=l'-0" a TYPICAL FRAMING DETAILS c11 E cop,, doom m G � s 1" 1N" 14a Li (2) 2 x 4 LAMINATIONS W/(1) (3) 2 x 4 LAMINATIONS W/ (2) (3) 2 x 6 LAMINATIONS W/ (2) ROW OF STAGGERED 1Dd ROWS OF STAGGERED led ROWS OF STAGGERED 16d COMMON WIRE NAILS (D=0.148",L=3") OR EQUAL COMMON WIRE NAILS (ONE FACE) EALH31/2')OR COMMON WIRE NAILS E FACE) =E0162 INTO ",L L/2IDOR D-016INTO EQUAL 3-CH (DUTSIDE EQUAL 1)N AO ALENT NAILS ARE DRIVEN FROM 3) FOR 4 PLY. PROVIDE 1/4"DIA. x 51/2" LAG OPPOSITE SIDES OF THE COLUMN. SCREWS OR EQUAL (SPACE AS SHOWN FOR 3PLY) 2) ALL NAILS PENETRATE AT LEAST 3/4" OF 4) REFER TO NDS SECTION 16.3 FOR THE THICKNESS OFTHE LAST LAMINATION. ADDITIONAL INFO. WF37 I TYPICAL COLUMNS DETAILS I N.T.S. FOR OVERHANGS GREATER THAN FILL 1ST. 4 COURSES 11/7 CONTACT FOR FOR SOLID W/ GROUT. (NO FURTHER INSTRUCTIONS REINFORCEMENT REQUIRED) H. F.F. NERHAN FOR OVERHANGS BETWEEN 5/8" TO 1 1/2" NOTE: FOR OVERHANGS LESS THAN 5/8" • NO REPAIR REQ'D MS18 I RETROFIT WALL OVERHANG DETAIL N.T.S. STRUCTURAL SHEATHING 7/16" MIN. NAILED W/ 8d COMMONS @ 3" O.C. @ EDGE & 6" O.C. HELD RUN FULL SHEET FROM BOTTOM OF FALSE BEAM SEE GE05 FOR ` STANDARD GABLE END FRAMING I O H I+ +I y I o 2X TOP PLATE TO 0 3 GABLE END W/ 16d NAILS @ 6" O.C. I � 2X4 STUDS @ 24" O.C. W/ SINGLE BASE & TOP PLATE W/ PLYWOOD SHEATHING COVERING 10.5 1 FALSE BEAM AT GABLE END N.r.s. 2x8 SYP #2 TOP & BOTTOM ATTACHED W/ (1) ROW 16d 2x6 SYP. #2 NAILS @ 16 O.C. RIPPED BOX HEADER DETAIL PROVIDE 2x4 ON TO OF 2x8 TO BLOCK OUT 2 ROWS 12d @ TOP PLATE ATTACH W/ 3" O.C. OUBLE 2x4 (2) 12d NAILS O.C. TOP PLATE (SOLID BLOCK W/ 2x6) 4g+�ZN 2x4 STUD PER PLAN 2x4 BEYOND AGAINST 2x8 STUDS NOTE: @ ALL EXT. CONDITIONS ATTACH 2x STUDS TO TOP PLATE W/ (4) 16d TONAILS (2) ON EA. SIDE TYP. TOE NAILS MAY BE SUBSTITUTED W/ 2x8 STUD (1) SIMPSON H2.5A CONNECTOR @ EA. STUD TO PER PLAN TOP PLATE W 8d 2 112" x 0.131 NAILS (SIM. w/ 2x6 * NOT REQ'D. WHEN QT SYSTEM IS APPLIED STUDS) TOP PLATE TRANSITION PIPE OR DUCT w/ OUBLE 12d PENETRATION THRU TOP SPLICE TOP PLATE w/ MORE THAN 50% OF TOP ROWS 12d PLATE WIDTH INSTALL @ 3" O.C. SIMPSON PSPN516Z W/ (12) 16d NAILS TYP. TOP & BOTT.+M7N NOTE: @ ALL EXT. CONDITIONS ATTACH 2x STUDS TO TOP PLATE W/ (4) 16d TONAILS (2) ON EA. SIDE TYP. TOE NAILS MAY BE SUBSTITUTED W/ (1) SIMPSON H2.5A CONNECTOR @ EA. STUD TO TOP PLATE W 8d 2 1/2" x 0.131 NAILS * NOT REQ'D. WHEN QT SYSTEM IS APPLIED NOTE: PLATE LENGTHS MUST BE AT LEAST 8'-0" LONG. TYPICAL STRUCTURAL SHEATHING EXTERIOR SHEATHING ATTACHED PER NAILING SCHEDULE TB13 ON , SHEET 6 , R-19 INSULATION AT EXTERIOR ' WOOD FRAME WALL PER FBC AND ENERGY FORM SUBMITTED WITH PERMIT APPLICATION (WHEN EXTERIOR WALL IS EXPOSED TO INTERIOR SPACE) ' 2 X 4 P.T. i LINTEL NOTE: HOLD FRAMING 1/2" BACK FROM FACE OF BLOCK FOR SHEATING TO BE FLUSH WITH BLOCK FACE CLIP EACH TRUSS (SEE ROOF PLAN FOR TYPE) FRAME OUT TO BLOCK EDGE STUD ANCHORING: STUD TO TOP PLATE: SIMPSON SP4 2 X 4 SPF AT 16' O.C. STUD TO BOT PLATE: SIMPSON SP4 1/2" X 8" ANCHOR BOLT @ 32" O.C. 8" CMU WALL NF21 I KNEEWALL @ ENTRY FRONT WALL 1 3/4"=1' OP SPLICE DOUBLE 2x8 TOP PLATE 2x4 w/ 2 ROWS OF 12d NAILS @ 3" O.C. WOOD BEAM SEE PLAN FOR SIZE SIMPSON HUC410 OR (2) HUC210 TO BUILT-UP COLUMN SUPPORT COLUMN BUILT-UP MIN. (3) 2x4's OR 4x4 W/ (2)-10d I � NAILS @ 8" O.C. EACH PLY (SHOWN AS 4 x 4) 1 (2) SIMPSON HETAZO'S 4 ; W/(12)-16d EA. TO COL. ALT: (2) MSTAM36 STRAPS /IOTTOM SPLICE TYPICAL BLOCK , CENTERED W/ (13)-10d NAILS / OVER STUD WALL `4 ' �,. Ea TO COL. TIE BEAM VF17 I TOP PLATE SPLICE DETAIL 3/4"=1' * CRIPPLES MAY/MAY NOT BE PRESENT. Q IF ONLY (1) KING 7/16" O.S.B. VERIFY HEADER ELEVATION (1) JACK USED AT EA. SIDE EACH SIDE OF 2X BLK'G. TO OPENING G.C. TO O.S.B. W INSTALL (3) TITEN HD. W/ 2 8d EA. END 5/8 x 8" EQUALY SPACED PER SIDE INTO CMU AT JACK TO HEADER, NO BASE EDGE VIEW HEADER SUPPORT NO. OF JACKS & STUDS REQ. AT OPENINGS OPENING 2 X 4 WALL 2 X 6 WALL JACKS KINGS JACKS KINGS SIZE EA END EA END EA END EA END LESS THAN 4' (1) (21 1J 2) >4' BUT <9' (2) (3) (2) (2) 10'-O" - IV 3 4 3 q CONNECTOR REQUIRED P4 AT (3) 16d SEE PLAN COMMON FOR LULL W/CRIPPLES SIMPP SON @ 16" O.C. 24" O.C. NAILS(TYP)HGT. TOP AND � W/ AND BSP2 TYP. — BOTTOM CMU— M /. i%% � 7 _j , 'z�# 177 , F04 /F ' • • • •' NAILER ,III Ih,' .. • `' • ! CONTINUOUS2x4 SPF • ! ©AT rACH ED TO • :. NAILS. SEE DETAIL ABOVE ELEVATIONSEE •"• SQUARE• BOX HEADER EACH END WINDOW OR DOOR OPN'G '--CMU WF39 TRANSOM DETAIL AT ENTRY 1/2" = V * WHEN STUD LENGTH IS LESS THAN 12" USE LSTA30 STRAPS AT EACH STUD WRAPPED OVER TOP PLATE & NAILED TO HEADER EACH SIDE FILL ALL HOLES IN — STRAP 10d NAILS @ 8" O/C TYP. DOUBLE 2 x 4 CRIPPLE STUD TYPICAL (U.N.O.) - * * HOLD DOWN CONNECTIONS NOT REQUIRED @ BEARING WALLS WITHOUT UPLIFT HEADER ANCHOR NAILED TO TOP PLATES, HEADER & JACK HEADER SIZE N0. & SIZE OF & GRADE RAFTER TIES EACH END SEE PLAN FOR (2) LSTA 30 BEAM SIZE iEE SCHEDULE 2-ROWS 12d NAILS STAGGERED @ 12" O/C EACH FACE OR 3-ROWS 12d NAILS STAGGERED @12"O/C FOR 2x 10 OR GREATER HEADER DOUBLE 2 x #2 S.Y.P. HEADER W/ 1/2" FLCiCH PLATE HEADER. (U.N.O.) FILLING AND BLOCKING AS REQUIRED FASTENED TO HEADER W/(2) ROWS OF 12d @ 16" O/C UNLESS NOTED OTHERWISE "+.iZF3lRE%3.79 SIMPSON HTT4 W/ (18) 16d NAILS & A 5/8" EXPANSION ANCHOR W/ 6" EMBEDMENT U.N.O. OR.81/2" AT GARAGE STEP DOWN P.T. BOT. PLATE WF09 I WALL HEADER DETAIL N.T.S. EXT. OUT BEAM TO SUPPORT SIMPSON HUC410 TRUSSES IF SPECIFIED ON PLAN ------I --I - - i 1 BUCKET SEE ROOF • - - - 1 PLAN FOR MORE INFO ' SEE ROOF PLAN FOR BEAM SIZE , 1 & CONNECTION INFO 1 SEE FLOOR PLAN 1 , FOR COLUMN SIZE & `------ -- BASE CONNECTION INFO OPTION A 0 PTI O N B 1/2" OSB FLITCH PLATE SEE FLOOR PLAN FOR REQ'D ONLY WHEN INDICATED COLUMN SIZE & BASE ON BEAM SCHEDULE/PLAN CONNECTION INFO SECTION A -A SCALE: 1 1/2" = 1'-0" SEE ROOF PLAN FOR BEAM SIZE & SEE FLOOR PLAN FOR COLUMN SIZE & BASE CONNECTION INFO— AA SEE PLAN FOR 777777A-TOF5 OF BEAM FOUNDATION N FOR MORE INFO CD11 I COMMON BEAM ATTACHMENT N.T.S. 2D04 BEAM @ RAISED ENTRY MASONRY WALL N.T.S 12 SEE ELEV. (TYP) PRE-ENGINEERED WOOD TRUSSES @ 24" O/C UPLIFT CONNECTOR (SEE SCHEDULE) DOUBLE 2"x4" TOP PLATE "x4" STUDS @ 16" O/C r—CRICKET AS REQUIRED SIMPSON SP2 @ FA. STUD - APA RATED STRUCTURAL SHEATHING MIN 7/16" FASTENED TO TRUSSES W/ 8d COMMON WIRE NAILS @ 4" O.C. BOUNDARIES 6" O/C EDGES & 8" O.C. FIELD R-19 INSULATION AT EXTERIOR WOOD FRAME WALL PER FBC AND ENERGY FORM SUBMITTED WITH PERMIT APPLICATION (WHEN EXTERIOR WALL IS EXPOSED TO INTERIOR SPACE) - - SIMPSON SP1 @ EA. STUD 2"x P.T. PLATE MAIN SPAN ROOF TRUSS 1/2" X 8" "J" BOLT @ 24" O/C MAX UPLIFT CONNECTOR 8" x 8" x 16" K.O. (SEE SCHEDULE) BLOCK W/ 1 #5 CONT. CMU WALL WF42 I KNEEWALL ABOVE MASONRY WALL �& z '''/ •IAA r fPBiF Vt N c ' I ' L g ga CU0'96! dwG W`m K�¢ mv: s� p !i moweZB'a; YNM'.WSENG.i'AM 000 ( Z0 m W Z 1j Z N O m o o < a Wa � E W — zLn y WOw V� c/) o m }� lJJiil ��ILiF � U w c ON E O C, v <<[ U 0� to o <mom Q.m i DAMS HOMES FLORIDA CONTRACTORS UCENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE,FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE jV Job Information: 0 0 ) a L z O �_ C e4 a W O In L LO q, m f 7 +� m 9 �l Ln I—�Um m 2 00 N _ 0 _1 L LJ :D M o .I M 0 0 L0 Model Name / Number: 1820 d Plan Issue Date: Wednesday, March 11, 2020 VT KA PROJECT NUMBER: s 20-1548 o Sheet: S�� Of: a TYPICAL WALL DETAILS U *DIAGONAL SPACED AT 20'-0" O.C. MAX I _R . TO BE LESS THAN SAME SPACING AS BOTTOM CHORD LATERAL BRACING ' OR EQUAL TO 450 ` I MINIMUM 2"x4" ' CROSS BRACING '. (SEE PLAN FOR - T ' - ^• LOCATION) BLOCKING ' ,I i ' c ' J O (3) 12d PER JOINT ' Wp CONTINUOUS LATERAL BRACING- tl1 NAIL OVER X-BRACE AS SHOWN - INSTALL BLKG. AT TRUSS WEBS `m CONTINUOUS BOTTOM CHORD BRACING 2"x4" MIN. FOR NAILING _X-BRACING - 2x4 SPF OR SYP o w/ (3) 12d @ EACH TRUSS WEB .2 E aci 3 m Q T11301 TYPICAL CROSS BRACING DETAIL N.T.s. TB02 TYPICAL CROSS BRACING DETAIL N.T.S. m Z I PROVIDCENTERELINE �,+�1/1111 i l►//1�Jk -(ORRES OF HIP/RIDGIE, TYP. `k ii` A, BETWEEN TRUSSES W/ (2) 12D NAILS EACH END TO TRUSS TOP m y0 .. T �' N �-: G • CHORD E .; a { . o , VA N m OLi A TRUSS ALTERNATE TO BLOCKING PRE-ENGINEERED VERLAP TRUSS BRACING`, WOOD TRUSSES AT LEAST ONE TRUSS 6" OVERLAP T A. A TRUCTURAL ---"" PACE >, G.T. SHEATHING a ADD 2X4 ALONGSIDE RIPPED 2X4 SYP #2 'm m TOP CHORD WHEN REQ'D NAIL TO TOP CHORD $ c TO PREVENT SHEATHING ACK -KHOF HIPPED TRUSS W/ RUSSE m SPAN FROM EXCEEDING P 12d NAILS @ 6" O.C.MAX 24" SPAN (EITHER T SIDE OR BOTH IF REQ'D) m s ROOF (2) 12D NAILS SHEATHING AT 12" O.C. MAX SEE MINIMUM (3) 12d PER JOINT MINIMUM 2"x4" SPF OR * SPACED AT 10'-0" MAX SYP TRUSS BRACING T w E a � 6 N R (D & "g m PLAN �g �cOQm J 0 2X4 BLOCKING m g -W' r m BETWEEN TRUSSES HIP TRUSS.01 t� O� m,=A`i W y C ��'CNp a Fg m SECT_ A -A a W 5. $g OeY� ri; aaLu ¢ Of g � a % N.T.s. TB04 N.T.S. FT HIP RIDGE BLOCKING DETAIL / TRUSS BRACING OVERLAP DETAIL TYP ) y ' �% 0 m m ILm 'e�5 W i 01 4R u IL ' 9N$ {� o. C) U) W V J f ®�o WftLFDSENG.COM m W TRUSS NOTES: 1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/71-2014 (TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST COMMON CAUSE OF ACCIDENT WOOD TRUSS CONSTRUCTION, FULL BUNDLES OF SHEATHING SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD SHOULD BE LIMITED _9 c W a. IN m Z TO 8 SHEETS OF SHEATHING ON ANY PAIR OF TRUSSES & SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT m _ EVENLY OVER A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. O 2. ALL BRACING (OB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTURER ALL m � JL LATERAL BRACING SPECIFIED BY TRUSS MANUR SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'0" O.C. MAXIMUM.LL 3. ALL BRACES SHABE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ (2) 3-12d NAILS AT EACH TRUSS INTERSECTION. .c O E — 'A y �_ 4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. 'm O (�1 5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS DEPTH EXCEEDS STANDARD HEEL HEIGHT. C m C/T SEE TYP. TRUSS BLOCKING DETAILS m c mcm+ n SHEATHING L.T m ' = 3 TO 4 TRUSS x4 AS SHOWN ALTERNATE N�.a TRUSS SPACES DIRECTION ? O & RUS ui c� ` A DAMS HOMES VERTICAL SCAB 2X6 #2 SPF 48" O.C. W/ (4) 12d TOP &BOTTOM OR H5 SEE TRUSS (2)- NAILS v` FLORIDA CONTRACTORS LICENSE N0. CRC1330146 OR HCLR/LL IN PLACE OF (4) 10D SECTION TO EA TRUSS REQUIRED @RAFTERS GREATER THAN 8'-0° B-B ° .... .... 3000 GULFBREEZE PARKWAY SEE FLAN W BLE TOP DOUBLE SEE STRUCTURAL NOTES AND NAILING " GULFBREEZE FLORIDA 32563 PRE-EN6. TRUSS PLATE SECTION B-B TOP PLATE SCHEDULE FOR SHEATHING DETAILS VARIES ROOF m 2x STUD WALL w DIVISION LOCATION: SLOPE PORT ST. LUCIE SEE PLAN _2 CONV. FRAMED RIDGE MAY BE NAILED w/ MIN. VERTICAL SCAB 2X6 42 \ / \ \ 2X4 SPF BLOCKING / / lob Information: (4)12d WHEN IT LANDS NEXT TO PRE-ENG. TRUSS SPF 49" D.C. W/ (4)12d \ / \ BETWEEN TRUSSES \ m —2x8 BIKING. NAILED � EACH TOP & BOTTOM OR H5 OR \ @ 48" O.C. MAX. SIDE W/ (3) 12d NAILS WHEN HCLR/LL IN PLACE OF (4) 12d ®RAFTERS GREATER B REQUIRED w/ 12) MT512'S REQUTHAN \ \ / / \ / .` Sp -Ow THAN s•-o" \ 2x4 SPF BRACE ' \ @ 48" O.C. - NAIL w/(4) / \ n I� COLLAR TIE \ 12d AT EACH END & EVERY SHEATH) aAFTeR� \ \ ALTERNATE DIRECTION \ \ O G 2X4 BLOCKING BETWEEN CB BEVEL CUTS \ w E TRUSSES W/ (2) 12d NAILS (OPTIONAL) 0 EACH END, CONT. EACH BAY n 0 © TB 2X4 SPF W/ (2) #7X&1/2" / / TRUSSES ¢ 0 LID ALTERNATING DB WOOD SCREW EACH TRUSS OR H5 @ 48" O.C. / / SEE PLAN - I I ■ F ate+ N O) BLOCKING / / i m M PRE�IG. TRUSS \ / / o o 0] LO CONT. ROOF SHEATHING AT TRUSS TOP STRUCTURAL SHEATHING CHORD AT ALL HAND FRAMED AREAS TYP- \ / / \ \ / / m o m Z In U SEE PLAN FOR CONNECTION SIMPSON A34 OR \ \ / / 0 L� r' m N a 1— v LO B 2X4 P.T. BLOCKING BETWEEN (USP MP4) �+ O J W Z) � LO WOOD 2x8 #2 SYP RIDGE BEAM /O AT 8'� EACH END TRUSS MAX2x6 RAFTERS ® 2'-0"O.C, TRUSSES W 2 -12d NAILS @ DIAGVCHORDSEARING 2'-0' ON (TENTER \ \ / / \ /\ / 2X4 SPF BLOCKING BETWEEN TRUSSES � ai J MAX. W/ (3) 12d COMMON Y 24" O.C. Model Name / Number: TOENAILS To RIDGE BEAM / _ 1820 WALL BELOW (SEE PLANS FOR TYPE) 2X4 RAFTERS FOR SPANS LESS THAN 4 FT @ Z-O' O.C. MAX W / (3) 10D \ \ ( ND (TYP.) (3)12d EA. END (TYP.) SEE PLAN NC. MASONRY COMMON TOE NAILS TO FUDGE BEAM p+ 2xEL OR WOOD m V Plan Issue Date: T & SUPPORT TYP. WOOD TRUSS BLOCKING A -A ALTERNATE BLOCKING 1/z" sPACE Wednesday, March 11, 2020 @ RAISED HEEL DETAIL DETAIL @ INTERIOR BEARING $ KA PROJECT NUMBER: SEE PLAN FOR MORE SHEATHING 20-1548 INFORMATION m m 2x4 S.Y.P. a Sheet: A Of. @ 16" O.C. N TBOG BLOCKING AND CONVENTIONAL FRAME DETAILS N.T. s. T615 I EXTERIOR NON -BEARING WALL DETAIL N.T.S. ROOF FRAMING a AND BRACT -. ILS Al 6" N \ THERMA-TRU INSTALLATION KEY DIFFERENCES CHECK LIST Rough openings are 1/41' smaller on each side and 1/4" smaller on the header than standard Therma-Tru rough opening dimensions. Use only a maximum of 1/4" thick shims. Predrill the jambs and headers using 1/81' drill bit. Predrilling increases structural performance. Use only 2-1/2" wood screws (#8 and #10) when securing the pre hung frame to the rough opening buck. Drywall screws, deck screws, and nails are insufficient anchors, and should not be substituted for wood screws. Be certain of the number and placement of all screws securing the frame to the rough opening buck. Consult the architect or engineer of record concerning fastening the buck to the rest of the building structure. CONTRACTOR TO PROVIDE A 1 x P.T. BUCK STRIP CONT, AT OPENING SIDES AND HEADER. ** 1 x BUCK STRIPS WILL BE ACCEPTABLE PROVIDED THE 3/16" DIA FLATHEAD TAPCONS ARE PROVIDED SPACED AS SHOWN. THE TAPCONS ARE TO BE CONTINUOUS THRU THE DOOR FRAME, 1 x P.T. BUCK STRIP AND HAVE A MINIMUM OF 1 1/4" EMBEDMENT INTO THE MASONRY JAMBS. Fe a" SPA EVE I. 6" 6" SINGLE DOOR SINGLE DOOR W SIDELITE r„ r„ 3" 0 3" 3„ 3- 3" I Li I1 3„ 3" 3" 3" 6, 6 6„ 6„ DOUBLE DOOR W/ SIDELITES 1A /E 7 i" 6, SPACE :VENLY 3 6 SINGLE DOOR W/ SIDELITES DOUBLE DOOR LOCATION OF BARRIER TO BE 111-0aF IN FRONT OF MECH. OR APP. WHEN REQUIRED 4" DIA. CONCRETE FILLED PVC. PIPE. m TOP OF SLAB 00 o z I ' a r— 16" MIN. DIAMETER CONCRETE FOOTING 3" SPACE EVENLY m acot Ved6 7" s to use In I..s�N�!!1!�J■■ NAIL SHINGLES W/ 11 OR 12 GAUGE ROOFING NAILS. 3/8" MIN HEADS. B PER SHINGLE. w-.1°s Naso 3c6OO"t"a 79" EwLend the sNngles over the eke and eaves about 1/2" H dd, edge iB used, or about 3/4" If no drip Ddge Is two. valley centenine ' SHINGLE INSTALLATION GUIDE ROOF CRICKET: MIN: 3:12 SLOPE ASPHALT BASED (REQUIRED AT SEALANT APPLIED ALL LEVEL VALLEY TEXTURED, PAINTED BEHIND FLASHING LOCATIONS) ETTER, WALL FINISH fN D EXTENDING ABOVE 8" X 6" H GA-V. VERTICAL RISE OF FLASHING VERTICAL WALL SHINGLES FLASHING CONT. AT KNEEWALL T ENTRY PIASTER STOP —,SEALANT ft00T� ` FLASHING DETAILS v 6° HORIZ. NOTE: THIS DETAIL IS REQUIRED F SHING AT ALL VERTICAL WALL INTERSECTIONS WITH ROOF VALLEYS & ROOF CRICKETS. FLASHING DETAIL AT CRICKET / KNEEWALL INTERSECTION INSTALLATION OF BUCK BUCK STRIPS - 2x (DEPTH OF W'DOW AND/OR SGD FRAME MIN.) GLUE STRIP w/ ADHESIVE SEALANT & SCREW w/ 3/16" \ x 3 1/2" PHILLIPS FLAT HD. "TAPCON" SCREW MIN, 4" FROM END AND 16" C.C. TYPICAL 2x BUCK INSTALLATION OF WINDOW ATTAC H M ENT N.T.S BUCK STRIPS -1x4 (DEPTH OF Wow. FRAME MIN.) GLUE STRIP W/ADHESIVE SEALANT BLOCK LINTEL & SCREW W/3/16" x 2 1/2" PHILLIPS 1/2" DRYWALL FLAT HD. "TAPCON" SCREW THRU N THE WIDOW FRAME INTO MASONRY \ JAMB MIN. 4" FROM END AND MIN. 16" C.C. 1/8" SHIM SPACE EXT. FINISH ° DRIP EDGE WINDOW SEALANT BACK OF JAMB GENERAL CONTRACTOR TO COORIDATE SPACING AND SIZE OF TAPCONS w/ WINDOW MANAFACTURER'S SPECIFICATIONS TYPICAL MASONRY OPENING WINDOW INSTALLATION N.T.S 2X WOOD FRAME BY OTHERS 5HEATf IINb' BY OTHERS CAUILK`BETWEEN FIN &SHEATHING CAULK BY OTHERS O.A. WINDOW HEIGHT EXTERIOR 11/20 MIN. EMBEDMENT -- 49 I11001) SCREW INTERIOR TYPICAL FRAME OPENING WINDOW INSTALLATION N,T.S R905.2.8,5 DRIP EDGE. PROVIDE DRIP EWE AT EAVES AND SABLES OF SHINGLE ROOF. OVERLAP TO ST A MIN MUM OF 31n 76cm1. SAVE Dan EDGES SHALL EXTEND Vsh BELOW SHFATHNG AND MOD BACK ON THE ROOF A MINIMUM OF tin. DRIP EDGE AT EAVES SHAL-BE PERMITTED TO RE NSTKtED EITHER OVFR OR UNIFR THE CNDFRI. AYMEM- F INSTAL I.FD DYER THE ENDERLAYMENT, THERE SHALL BE A MINIMUM 4h WIDTH OF ROOF CEMENT INSTALLED OVtA IHL DRIP ELSE H ANDE. Urn' EUGE SHALL BE MCCI IANICALLY fA5(CNCU A MPXW UM 01121n ON [YM3. WHERE THE WW AS DETERMINED IN ACCORAWE WI*H SECTION R3012.LB Situ MPH 1177 KM/HI OR GREATER OR THE MEAN ROOF HOGHT EXCEEDS 33 FEET I10,098 mm)• DRIP EDGES SHALL BE MECHANICALLY FASTENED A MAKMUM OF 41NOHES ON CENTER Madmum Fastener Spacing (lambs Head acid$111) Screws Meuni Fin _ exterior Axed VIEW, Window of — —_— - Wall Frandw #2Spruoe/Mne/Fir Or Seder / Silicone Yl01 — sore. Minimum Penetration Glazi"g Bead 1.3/8" Crow Section View Ex erfarsheNMng µd-e b>t blvks Fran si sW"s n,,d osier do es until ca.atmcron is cdrtlpl¢P.. Step 1 Measure to be sure the opening I5 318" to Ur larger than the Window size both vertically and hmhmfally. • You MaY Wish To pleddll to mularation Holes in the fin at this trine. ObVegand Me DrejUrsidnedho'es as Memcvn as MW are not Step 2 Apply a gerrerous head of sllicorle to the backside of the n ourti g fin. Use enough Sksirm to su fbemly fill all voids between de fin and the wait ShSithing. SW Ircertthe wallow brio the opening Fran the outside. The window is labeled "kslde"and"oobede", but lfthaw IBbeh have been removed, the glazing bead should always be to the inside of the budding. %W 4 Install shirrs wda the sill, adjusting them unEl the Led is planb In the opening, SMms should be Installed under the sib every 2 feet. The window should be basically centered In the opening with w more than 4" gap between the window and wall firarning. S Install a#10 X 1-Y screw, 4' from the caner of the fin at each end of the tread sill and bah iambs, Swp6 IRstull the remaining flITAmars In 8- Rxiemei Gam the corner, screws In the ceder of each frame menb r. Use came not W ower, tighten the mmme and pIA1 Meinth" the f n. Ake, make surethe aoT go M stra htend do Tetouse bA fmma to bow. Waft tanning shawl b a mlmmu n of #2 Sprum/Plneila. Fasteners ahndtl be #10 screws of %ftmt length to achieve 1-3/8" dratan lids Me well and per less dean Itr from edge of Vent". Fastener ouaTlttlea needed in each side of tame In amlew, W sradm Sep 8 tdeslfed, A mom InWelkii l tan be applied M the inenm gap between the window and wall taming: If ap0ft%J Mirmust be d e NON EXPANDING I'YPEFAAN. Step 9 Since these windows are typically used in moms with high mdandis, Is; beMreams, t h remmrnantlM Mat the MaMW gap between the window and wall taming also be sealed with Alkme and tooled W as not to Interfere with the installation of walPooard, his or trim. Step 10 Once all constructon is conpkte, rebore the bubble wrap from the Inside and outside of the window. If neoessay, clean to bmtka with a Mid deougent and warm water Ysalg a soft doth, Failure to follow these procedures will void any and all warranties. GENERAL NOTE: 1- SEE COVER SHEET FOR WIND PRESSURE AND EXPOSURE. 2- SEE ELEVATION SHEET FOR ROOF OVERHANG AND PITCH. 3- SEE TITLE BLOCK FOR ENGINEER SEAL AND INFORMATION. SEE STRUCTURAL SHEETS FOR ANY STRUCTURAL INFORMATION AND CALL OUTS. Product Approval Submittal Affidavit Building Address: Contractor: Building Permit: Product Design Pressures Manufacture Model # Attachment Method Approval # Roofing: 1st Choice DE COUNTY APP. IKO Industrues, Ltd Cambridge AR NAIL SHINGLES W/ 12 GAUGE ROOFING NAILS. 3/8" MIN HEADS. 6 PER SHINGLE. FL7006.1 R-10 W/ 3/8" MIN PENETRATION THRU SHEATHING ROOFING VENTS- " Florida Metal FLAMED FASTEN WRH 11 GAUGE GALVINIZED RING SHANK ROOFING NAIL, Products Inc. "Off -rid a vent" ^EEOM EDGE AND 4" O.C. TYPICAL mAx FL21580.1 R-1 ROOFING UNDERLAYMENT: 1st Choice WOODLAND TYPE II UNDERLAYMENTS-HVHZ UNDERLAYMENT SHALL BE APPLIED AND FL15216 - R3 INDUSTRIES C 1#30 ASPHALT -SATURATED ORGANIC FELT ATTACHED IN ACCORDANCE WITH R905.1.1 F 0 2nd Choice Overhead Garage Doors: 1st Choice +30.0/-30.0 CLOPAY 73W6 16 x 7 2"x6" P.T. WOOD JAMB WITH (5) 1/2" DIA. x 8" "J" BOLTS FL16546.1 2nd Choice +30.0/-32.0 CLOPAY W6 73 B X 7 FL15279.36 Swing Doors: 1st Choice +67.0/-67.0 THERMATRU-CORP. FIB RG SS GLAZED INSWING 2xBUCK ATTACHMENTTOBEATTACHEDWITH3/16"X3" TAPCONS MIN. 4" FROM TOP & BOTTOM OF INTERSECTIONS AND MIN. 12" O.C. THEREAFTER. THE DOOR FRAME SHALL fL20461.1 2nd Choice +67.0/-67.0 -C THERMA TRU-CORD. FLUSH FL20461.19 OUTSWING BE ATTACHED WITH 3/16" X 3" WOOD SCREWS MIN. FROM 4 1. TOP & BOTTOM OF INTERSECTIONS AND MIN. 16"O.C. THEREAFTER. (TYPICAL ALL 4 SIDES) Siding: 1st Choice +0/-146.3 The Tapeo Group 7" Staggered Shakes INSTALLAITON FASTERNERS ARE GALVANIZED STEEL ROOFING NAILS 11f2" LONG WITH 1/8" DIA. SHANKS & 3/8" DIA. HEADS AT 10" O.C. HORIZONTALLY. EMBEDMENT TO BASE MATERIAL FL20403.17 N.A. N.A. IN A SHALL BE BEYOND WALL DRESSING Windows: 1$t Choice +40/-50 MI WINDOWS 3540 SERIES Single Hun (fin)ANCHOR SEE BUCK DETAILS (THIS PAGE) FOR UNIT INSTALLATION USE 3/16" TAPCON WITH MIN. 1L6" EMBED. TO ALL FACTORY DESIGNATIONS WITH ALL HOLES NOT DESIGNATED FOR TARCON SHOULD BE FILLED W/ #8 SCREWS OF SUFFICIENT LTH. TO PROVIDE 5/8" MIN. EMBED. INTO WOOD BUCK. FOR INSTALLATION THROUGH 2x BUCK USE #8 WOOD SCREW OF FIL 17676.1 R9 +40/-50 MI WINDOWS 3540 SERIES Single Hung (flange) FL 17676.8 R9 3540 SERIES +50.0/-50.0 MI WINDOWS Picture window SUFRENT LENGTH TO ACHIEVE 11fi" INCH MINIMUM EMBEDMENT FL18644.3 R3 IN WOOD SUBSTRATE. Mullions: 1st Choice M-1926 MI WINDOWS Vertical FOR ATTACHING MI WINDOWS MULLION SECT5796 CLIP INTO CONCRETE FL 18504.1 Mullilipon 3/1-6" TAPCON ANCHOR WITH SUFFICIENT LENGTH TO ACHIEVE A 11A Horizontal FL 15804.2 M-1926 MINIMUM EMBEDMENT WITH 1" MINIMUM EMBEDMENT WITH 1" MINIMUM EDGE DISTANCE Fixed Glass" • 1st Choice +50.0/-50.0 US BLOCK 625 FOR UNIT INSTALLATION USE 3/16" TAPCON ANCHOR FL18644.3 R-3 WITH MIN. IA" EMBED. TO ALL FACTORY DESIGNATIONS WITH ALL HOLES NOT DESIGNATED FOR TAPCON SHOULD 2nd Choice BE FILLED W/ #8 SCREWS OF SUFFICIENT LTH. TO PROVIDE 5/8" MIN. EMBED. INTO WOOD BUCK. 3rd Choice Soffit: 1st Choice 1 +55.0/-35.0 KAYCAN LTD 8" BEADED D FFIT VINYL 1 1/2" NAILS 10" O.C. IN I DIRECTION OE SOFFIT LENGTH FL16503.4 R-3 Hurricane Panels: 46 PSF EXT HURRICANE STORM 24" Ga. DIRECT MOUNT. TOP 1/4"-20 MALE-PANELMATE W/ / Galvanizes FL16293.1 1st Choice 46 PSF INT. PANEL MFG. INC. Steel Storm WINGNUTS AT 12lh" O.C. BOTTOM 1/4^-20 SIDEWALK Panels BOLT w/ POWERS CALKAN I have reviewed the above components of cladding and have approved their use in the structure. (Architect or Engineer of record) Name: Carl A. Brown Certification Number: FI. # 56126 Name: TODD M. BORN Certification Number: FI. # 82126 _ Name: Luis Pablo Torres Certification Number: FI. # 87864 - a m c' 0 UP a sJ 211 tO toNW '�@p a !• a 0 Do Ole SC E gg LL (otro-m ( O o " s8r>i Row MOD.%, W wUirl- vi Oar\ a u.€ ,. 13 ; o m yAJff� y 19 w5SK WE ��Y 13T O gm � LL2Na e n c d OL 13 d��inT Qy.y y rs m - Www.FDSrNG.COM ❑ ❑ ❑ LD in z rn err C4 V/ Z M o u c ,0 Z ¢ o LY J a p3 L _ Y ts- o Z o 111 t9 ¢ m w 12 OurF- 10o _E V 0 � Dido u 0 g m mm r woo$ (' 0 ' 5� 2 �.' �� 0 c Unq N Y10 A\ DAMS HOMES T—Oo FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 a L DIVISION LOCATION: PORT ST. LUCIE Job Information: v m n O s a cO z o�LID ou m -E W > ` V y M O o Ln C GI 4 U) 3 0 20 U) a) 0 J ED -1CnW n 0 n � 7V Model Name/ Number: U20 oV Plan Issue Date: a Wednesday, March 11, 2020 vVI KA PROJECT NUMBER: Y 20-1548 T m 0 Sheet: ark C Of: V V MATERIAL REFERENCE INFO (PSL) MECHANICALLY FASTEN AS FOLD UP WEATHER NECESSARY IN CORNERS THROUGH RESISTIVE BARRIER & WEATHER RESISTIVE FLASHING REQUIREMENTS THESE DETAILS ARE GENERIC AND MEANT TO SHOW SELF -ADHERED FLASHING �,. / TEMPORARILY SECURE BARRIER GENERAL FLASHING AND WATERPROOFING METHODS DOOR ROUGH OPENING TO BE USED. R703.1 General. Exterior walls shall provide the building with a weatherresistant exterior wall envelope. The exterior �WEATHER RESISITIVE WINDOW UNIT wall envelope shall Include flashing as described In Section R703.4. A water -resistive banter Is described as a - BARRIER WOOD FRAME CONSTR. material behind an exterior wall covering that Is Intended to resist liquid water that has penetrated behind the exterior TAPE s EXTERIOR SELFADHERED FLASHING 314'-1' BEAD OF CONSTR. SLOPE covering from further intruding into the exterior wall assembly_ An exterior wall covering is described as a material or SHEATHING BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER 0.3 in: 12.0 in SELF ADHERED FLASHING assembly of materials applied on the exterior side of exterior walls for the purpose of providing a weatherresistive OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN (0.6 cm : 30.5 cm) barrier, Insulation, or for aesthetics, including but not limited to, veneers, siding, exterior Insulation and finish systems, ' vasc+.�oowixnow; WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND OR EQUAL WEATHER PROOF CAULKING SELF -ADHERED FLASHING PRODUCTS DETAILS architectural trim and embellishments such as cornices, soffits, and fascias. R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 WEATHER SELF -ADHERED FLASHING EXTERIOR for Type 1 felt or other approved water4osistive barrier shall be applied over studs or sheathing of all exterior walls. Such RESISITIVE CEMT. FIN. TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND felt or material shall be applied horizontally, with the upper layer lapped over the lower layer not less than 2 Inches BARRIER SEAL TOPS OF JOISTS ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2 (61 man). Where joints occur, felt shall be lapped not less than 6 Inches (152 Frm). The felt or other approved material UNDER DECKING shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner to meet the (SEE DETAIL WP07) SUBFLooR requirements of the exterior wall envelope as described In Section R703.1. SELF -ADHERED FLASHING WIRE LATH R703.7.3 Water -resistive barriers shall be Installed as required in Section R703.2 and, where applied over wood -based HEAD FLASHING TIE-IN INSTRUXTIONS: Detal ( I I1StrU CtIOn$ sheathing, shall Include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of 1. Cut, fold up &temporarily secure weather RIM JOIST Grade D paper. The individual layers shall be installed Independently such that each layer provides a separate resistive barrier above header to allow for flashing installation Refer to the number marked as ® in each detail that corresponds to the continuous plane and any flashing (installed In accordance with Section R703A) Intended to drain to the water -resistive 2. Self -adhered flashing plus head flashing under weather BUILDING nl b ti t f i t li th i ed it be umrems n e sof below: barrier Is directed between the layers. resistive barrier 3. Fold weather resistive barrier back over head flashing and seal with tape 1 2 1 2 PAPER O 1. Install self -adhered flashing in order as shown by numbers 2. 1 nstall flashing and weather resistive barrier to form water shedding laps 9 9 P 3. Self -adhered flashing can be substituted for building paper Exception: Where the water -resistive barter that is applied over wood -based sheathinghas a water resistance equal to or greater than that of 60-minute Grade D g paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or designed drainage space. 4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - for ease of installation and to minimize y ) R703.4 Flashing. Approved corrosion -resistant flashing small be applied shin le fashion in a manner to of g p g g prevent entry Scale: NTs SELF -ADHERED FLASHING FLANGED WINDOW WPM SELF -ADHERED FLASHING TWPO 2 SELF -ADHERED FLASHING �/ P03 Scoring Cuts water Into the wall cavity or penetration of water to the building structural framing components. Self -adhered membranes a used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with the EXTERIOR DOOR WITH DECK - SECTION A CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER 5. Remove all release paper per standard installation instructions and building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint adhere to substrate using a square piece of Hashing material (6" x 6" expansion and contraction, ASTM C1281, AAMA 812, or other approved standard as appropriate for the type of seala. nt EXTERIOR SHEATHING RUBBERIZED ASPHALT RUBBERIZED Minimum) Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing Mall extend to the finish. ADHESIVE surface of the exterior wall Approved corrosion resistant flashings shall be installed at the following locatlona: EXTERIOR SHEATHING 3/4"-1" BEAD OF CONSTR. ADHESIVE TO BE APPLIED UNDER INSTALL SELF -ADHERED FLASHING JAMB & HEAD ASPHALT 6. Fold as shown by arrows THRESHOLD OF DOOR AND RETURN FLASHING, SEE ADHESIVE SELF -ADHERED FLASHING 7. Angle of corner may vary, adjust folding of the flashing accordingly to fit 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW tight CO Corner exterior wall finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. REFER TO TECHNICAL OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) I Mechanically attached flexible flashings shall comply with AAMA 712. Flashing at exterior window and door openings LETTER ON CHEMICAL SCORED 8. Mechanically fasten as necessary shall be installed In accordance with one or more of the following: COMPATIBILITY RELEASE PAPER 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed In the SELF -ADHERED SELF -ADHERED FLASHING, ISEFOREFOLOING,SCORE fenestration manufacturer's Instructions, In accordance with the flashing manufacturer's Instructions. Where FLASHING EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE ADHESIVE flashing Instructions or details are not rovlded g provided, pan flashing shall be installed at the slit of exterior window and VERTICALLY FROM door openings. Pan flashing shall be sealed or sloped in such a manor as to direct water to the surface of the BOTTOM OF THRESHOLD exterior wall finish or to the water resistive barrier for subsequent drainage. 0 bse4 g . parings using pan flashing shall z a ' MECHANICALLY FASTEN AS Incorporate flashing or protection at the head and sides. SECTION -A NECESSARY IN CORNERS THROUGH SELF -ADHERED FLASHING 1-2. In accordance with the flashing design or method of a registered design professional. (SEE DETAIL WP02) 13. In accordance with other approved methods. - SELF -ADHERED FLASHING O \ 3-4 In accordance with FMA/AAMA 3.00, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. V 2 z 2. At the intersection of chimneys or other masonry construction with hams or stucco walls, with projecting lips on both SELF -ADHERED FLASHING 5 sides under stucco Copings. NAILING FLANGE 1 G 4 3. Under and at the ends of masonry, wood or metal copings and sills. DO NOT FLASH OVER - BOTTOM NAILING 2 8 SEAL TOPS OF JOISTS UNDER DECKING DETAIL WP07) t 2 B 4. Continuously above all projecting Wood trim. FLANGE (SEE S. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. 6. At wall and root intersections. SELF -ADHERED FLASHING W P 04 SELF -ADHERED FLASHING EXTERIOR DOOR WITH DECK FWP05 SELF -ADHERED FLASHING WP06 HALF ROUND WINDOW 7. At built-in gutters. SELF -ADHERED FLASHING DECK PROTECTOR SHEATHINGi 7/8" Cement Plaster" Cement in accordance with / accordance with Plaster n - _ --- SELF -ADHERED ASTMC926 ASTMC926 FLASHING PATCH "-,.". Fell backed metal - Felt backed metal lathe in accordance afire in accordance SELF -ADHERED FLASHING with ASTMC1063 with ASTMC1063 \ DECK PROTECTOR e >?'' , Building Paper Building Paper 7/16" O.S.B. 7/16" O.S.B. sheathing %. sheathing DOUBLE SINGLE JOIST Metal -- Keep top edge JOIST SELF -ADHERED FLASHING ` ' - Flashing g .. of weep Screed SELF -ADHERED FLASHING t , .. 2" below top Of 2 3 1 /2" block 3" MIN Unperforated .. . . 4 Flange 7/8" Vulcum Weep Screed caulk bottom O 5 joint only Maintain Metal Flashing SELF -ADHERED FLASHING \H0:8362x;DECK JOIST WP07 SELF -ADHERED FLASHING OUTSIDE CORNER p y �► APPLYA LIQUID FLASHING TO THE MASONRY OPENING (HEAD, JAMB, SILL) IN Bottom of Weep Screed 1/2" to 2" Unperforated Flange 7/8" Weep Screed INSTALLATION OF THE BUCKIRECEPTOR. Above Roof Sheathing 1/2" Cementitious Decorative Finish b • " o, All inside and outside EXTERIOR WINDOW UNIT 0' needto be miter CEMT. FIN. PlasterCement cut and caulked all PAPER SLOPE in accordance butt joints need to o, o • ' becaulked usin 9 SLOPE with ASTMC926 SLOPE 0.3 in: 12.0 in 0.3 in: 12.0 in (0.6 cm : 30.5 cm) 0.3 in :12.0 in (0.6 cm : 30.5 cm) over wood 2nd floor Vulcum caulk for all (0.6 cm : 30.5 cm) SELF -ADHERED FLASHING WIRE LATH SELF -ADHERED FLASHING ~-'-- EXTERIOR .. CEMT. FIN. BUILDING PAPER WIRE LATH " 1/2" Cement SELF -ADHERED FLASHING Plaster Finish Block WIRE LATH.: 2 1/2" Perforated ° Flange 1/2" Weep BUILDING PAPER BUILDING PAPER Tt Cement p, Screed Plaster over block EXTERIOR 1 st floor WINDOW UNIT CEMT. FIN. Install bottom Slab edge of weep screed 1" below finish floor OPTIONAL DETAIL $ g Note: O The building paper and metal lath must be installed over the to ofWEEP p SCREED DETAIL SELF -ADHERED FLASHING FINISH WINDOW WP 10 WP 12 U SCALE: NOT TO SCALE CEMT. HEAD CEMT-FINISH WINOW SILL tiji CEMTFFINISH PARAPET the weep screed. r 0 4L 'w d y R -fill N to 00 N g00 !"$L N rfi3&�j QOge1�$l-'0 N E 0 mm� 8 �p�� QiQ=pmp aj ,�`t®i'6g t9a.�i air aA�"sao0 ag mMgmY�a m m "E 2 0 ❑ w X "As in o li 9j; `' in I- A VMW..FDRENG.00N ❑ ❑ ❑ 10 J N V/ Z N Ory /e Z ro ■ Z O 0 o 4 r � J V I � Y Z u w F E O' w p t/) Q' In tf1 M 0 ro r c�ro wm O2W o � �sxrt "q M u, � v z 0 Ot Q m 0 °n 4c m. DAMS HOMES FLORIDA CONTRACTORS LICENSE NO. CRC1330146 3000 GULFBREEZE PARKWAY GULFBREEZE, FLORIDA 32563 DIVISION LOCATION: PORT ST. LUCIE VI Job Information: O a z� a ui W w 4) rf LO m a to3 m P J v/ vJ nn w Model Name / Number: 1820 Plan Issue Date: Wednesday, March 11, 2020 KA PROJECT NUMBER: 20-1548 Sheet: W P Of WATER PROOF DETAILS i III 2s SIT PRECAST BOTTOM a 6'- '. E 1\07EIR'S BEDROOM LANAI VAULTED CEILINIG VAULT CEILING o o' 14x8 1 wcd 2868 200 O N w 16x16 raef 6x16rag N W DBL 25 5" bath duct s' 14xl4 ra`- M f FAMILY ROOM to roof cap " 10' CEILING w/70 cfm fan w c 14x8 lwcd 10'11 CLG. 21 x4 1 cd N 5 1Ox10 N 8ss Ox6 1 wcd 45_ 0 s OWNER BATH 11 ,..,VAULTED CLG. �; 4 dryer duct 14x8 1wcd KITCH N 2668 'b• = 8' CLG. 1R/1SH loss ATH 2 DOOM ##: Ox6 1wcd 75 1 R/1 SH 24x1 fbr g DINING ROOM V) Ln N to roo, w/dryer vent pVAULTEDCEILING box 165 vnuLrE G. 7 12x6 l wcd x 130 v m REFRIG. VERIFY LOCATION W ' BUILDER Q "` VAULTED CLG. U N 12xl 2 rag 9" 1 1 ' CLG 4 }. D N mod. 0. O_ 711 4' STEP DN FOYER xl2 rag 42X42 A/C SLAB 8 10' CEILING PULL RE. STAIRS BY BLDR MIN 22 1/a' x 54" 2' FROM WALL m EN BEDROOM ##4 3068 /(2) 12» s.L. 12x6 1 wcd W 2 OAR GARAGE 140 8' CEILING 20 '.0„ ENTRY IEGRESS 10' CEILING" LINE OF GARAGE DOOR BM3 IF v ELEV M3 5" bath duct to roof cap w/70 cfm fan G.T. NOTE TO BUILDER: MUST PROVIDE UNRESTRICTED Pw i 16 X' 7 OVERHEAD DOOR i 1 INCH UNDERCUT BELOW DOORS TO HABITABLE ROOMS Transfer ducts/grills sized in compliance with Florida Residential Building Code—M1602.4 balanced return air. AREA CALCULATIONS EXCEPTIONS 1-3 1st FLOOR 1820 S.F. FLOOR PLAN TOTAL LIVING (AC) 1820 S.F. SCALE: 1/4" =V-0" GARAGE 396 S.F. ALL ELEVATIONS COVERED ENTRY (BASE) 56 S.F. COVERED PATIOAANAI 137 S.F. TOTAL AREA UNDER ROOF 2409 S.F. Must have a minimum clearance f 4 inches around th air handler 'er t = . o p he State Energy code. All duct has an r 6 insulation value Rating � m 0 W LU LU Q z LLl O O = LLJ V) p— Q U o ^� O Q ® J m Q Z N .. 00 Ln O 1 — — U) CV m W •• >_ Z Q Z Q LU J Q F-- m Q D J O D <[ Q:� mEL_jc10®®