HomeMy WebLinkAboutEnergy CodeCP
b•G O p
FORM R405-2017 yq
FLORIDA ENERGY EFFICIENCY CODE FOON31.1ILDING
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 175 Block 5 Waterstone 1820 DGLN
Builder Name: ADAMS HOMES
Street: 5365 San Benedetto Place
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2120.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
b. Frame - Wood, Adjacent
R=13.0 270.00 112
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1820.0 sqft.)
Insulation Area
a. Under Attic(Vented)
R=30.0 1820.00 ft'
6. Conditioned floor area above grade (ft2) 1820
b. WA
R= ft2
Conditioned floor area below grade (ft2) 0
c. WA
R= 112
11. Ducts
R ft2
7. Windows(237.2 sqft.) Description Area
a. Sup: Attic, Rat: Main, AH: Main
6 364
a. U-Factor: Dbl, U=0.33 168.74 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft'
12. Cooling systems
kBtWhr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.50
c. U-Factor: Dbl, U=0.33 18.33 ft2
SHGC: SHGC=0.31
13. Heating systems
kBtumr Efficiency
d. U-Factor: other (see details) 17.78 ft'
a. Electric Heat Pump
34.6 HSPF:8.20
SHGC: other (see details)
Area Weighted Average Overhang Depth: 4.069 ft.
Area Weighted Average SHGC: 0.269
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1820.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 112
b. Conservation features
b. N/A R= ft2
None
c. N/A R= 112
15. Credits
Pstat
Glass/Floor Area: 0.130 Total Proposed Modified Loads: 61.68
PASS
Total Baseline
Loads: 68.77
1 hereby certify that the plans and specifications covered by
Review of the plans and
S7}�A
this calculation are in compliance Florida Ene
specifications covered by this
DFTIiE
Code.
calculation indicates compliance
f`;•=:„
with the Florida Energy Code.
nrn"'%. O�
PREPARED BY:
Before construction is completed
tf
DATE: 03-1 R
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida ner y Code.
COb W6'iR0
OWNER/AGEN,T- '�
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1. ��
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.¢,41cei� pr�/@)�r'eeyires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). r LG V �+
3/18/2020 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 175 Block 5 Walerstone 1 Bedrooms: 4
User Conditioned Area: 1820
Total Stores: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot# 17
Block/Subdivision: Waterstone
PlatBook:
Street: 5365 San Benedetto PI
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2
— 0.42 0 0.58
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N
0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic '
Vented 300 1820 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft2 0.11 Wood
3/18/2020 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Belo w
Space
_ 1
SW
Exterior
Concrete Block - Int Insul
Main
4.1 59
0
10 0
590.0 ft'
0
0 0.6
0
-2
SE
Exterior
Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft'
0
0 0.6
0
3
NE
Exterior
Concrete Block - Int Insul
Main
4.1 66
0
10 0
660.0 W
0
0 0.6
0
-4
NW
Exterior
Concrete Block- Int Insul
Main
4.1 27
0
10 0
270.0 ft'
0 0.6
0
5
-
Garage
Frame - Wood
Main
13 27
0
10 0
270.0 ft'
• 0
0.23 0.01
0
-6
SE
Exterior
Concrete Block - Int Insul
Main
4.1 7
0
10 0
70.0 ft'
0
0 0.6
0
7
NW
Exterior
Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0 0.6
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SE
Insulated
Main
None
.25
3
6 8
20 ft2
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes
NFRC
U-Factor SHGC
Imp Area
Depth
Separation
Int Shade
Screening
1
SW 1
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exteriors
2
SW 1
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
SE 6
Vinyl Low-E Double
Yes
0.33 0.31
N
5.0 it'
9 ft 0 in
0 ft 6 in
Drapes/blinds
Exterior 5
4
SE 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
5
SE 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft'
1 ft 4 in
1 ft 0 in
Drapes/blinds
Exterior 5
6
SE 6
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft'
9 ft 0 in
2 ft 0 in
Drapes/blinds
Exterior 5
7
NE 3
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 W
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
NW 7
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 k'
11 115 in
0 ft 6 in
Drapes/blinds
Exterior 5
9
NW 4
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
10
NW 7
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
11 It 6 in
0 It 6 in
Dapes/blinds
Exteriors
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft
Sit
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000445
2123.3 116.57
219.22
.1685
7
3/18t202O 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heal Pump/
Split
HSPF:8.2 34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15.5 35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use
SeWnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
DUCTS
/ —Supply—
V # Location R-Value Area
--Return Air
Location Area Leakage Type Handler
CFM 25
TOT
CFM25
OUT
ON
RLF
HVAC#
Heat Cool
1 Attic 6 364 ft'
Main
91 ft' Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programablee ]Thermostar[t:,JY [[ ]]
Heating ( Jan l l Feb [)n Mar
Venting [ 1 Jan I 1 Feb [[X�l Mar
Cr[eiling Fans: [[ ]] [[ ]]
Apr [ May lMayxl Jun [X] Jul [X] Aug
Jun [[ l) Jul [( 11 Aug
[X]
[ I Sep
[ I Sep
[ ]
L 1
lXl
Oct
tt
Nov[jX]INovrX�]
(1(] Nov
Dec
[ ]DDec
ec
Thermostat Schedule: HERS 2005 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating(WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78 78
78 78 78 78
78 78 78 78
78 78 78 78
66 66 68 68
68 68 68 68
66 66 68 68
68 68 68 68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
0 ft 0.3
Main
3/18/202U 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 90
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: CapaciTy
35.0
a) Split system SEER
15.5
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1820
d) Room unit/PTAC EER
e) Other
7. Windows, Type and area
a) U-factor:(weighted average)
7a.
0.346
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.269
14. Heating system: Capacity
34.6
c) Area
7c.
237.2
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
B. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 1la. 30.0 b) Cross ventilation No
b) Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: �' Date:
Address of New Home: 5365 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951
3/18/2020 11:28:16 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1