Loading...
HomeMy WebLinkAboutEnergy CodeCP b•G O p FORM R405-2017 yq FLORIDA ENERGY EFFICIENCY CODE FOON31.1ILDING Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 175 Block 5 Waterstone 1820 DGLN Builder Name: ADAMS HOMES Street: 5365 San Benedetto Place Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(2120.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1850.00 ft2 b. Frame - Wood, Adjacent R=13.0 270.00 112 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1820.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1820.00 ft' 6. Conditioned floor area above grade (ft2) 1820 b. WA R= ft2 Conditioned floor area below grade (ft2) 0 c. WA R= 112 11. Ducts R ft2 7. Windows(237.2 sqft.) Description Area a. Sup: Attic, Rat: Main, AH: Main 6 364 a. U-Factor: Dbl, U=0.33 168.74 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft' 12. Cooling systems kBtWhr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.33 18.33 ft2 SHGC: SHGC=0.31 13. Heating systems kBtumr Efficiency d. U-Factor: other (see details) 17.78 ft' a. Electric Heat Pump 34.6 HSPF:8.20 SHGC: other (see details) Area Weighted Average Overhang Depth: 4.069 ft. Area Weighted Average SHGC: 0.269 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1820.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1820.00 112 b. Conservation features b. N/A R= ft2 None c. N/A R= 112 15. Credits Pstat Glass/Floor Area: 0.130 Total Proposed Modified Loads: 61.68 PASS Total Baseline Loads: 68.77 1 hereby certify that the plans and specifications covered by Review of the plans and S7}�A this calculation are in compliance Florida Ene specifications covered by this DFTIiE Code. calculation indicates compliance f`;•=:„ with the Florida Energy Code. nrn"'%. O� PREPARED BY: Before construction is completed tf DATE: 03-1 R this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida ner y Code. COb W6'iR0 OWNER/AGEN,T- '� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. �� - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.¢,41cei� pr�/@)�r'eeyires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). r LG V �+ 3/18/2020 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 175 Block 5 Walerstone 1 Bedrooms: 4 User Conditioned Area: 1820 Total Stores: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot# 17 Block/Subdivision: Waterstone PlatBook: Street: 5365 San Benedetto PI County: St. Lucie City, State, Zip: Fort Pierce , FL , 34951 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 1820 18200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1820 18200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 — 0.42 0 0.58 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic ' Vented 300 1820 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1820 ft2 0.11 Wood 3/18/2020 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space _ 1 SW Exterior Concrete Block - Int Insul Main 4.1 59 0 10 0 590.0 ft' 0 0 0.6 0 -2 SE Exterior Concrete Block - Int Insul Main 4.1 13 0 10 0 130.0 ft' 0 0 0.6 0 3 NE Exterior Concrete Block - Int Insul Main 4.1 66 0 10 0 660.0 W 0 0 0.6 0 -4 NW Exterior Concrete Block- Int Insul Main 4.1 27 0 10 0 270.0 ft' 0 0.6 0 5 - Garage Frame - Wood Main 13 27 0 10 0 270.0 ft' • 0 0.23 0.01 0 -6 SE Exterior Concrete Block - Int Insul Main 4.1 7 0 10 0 70.0 ft' 0 0 0.6 0 7 NW Exterior Concrete Block - Int Insul Main 4.1 13 0 10 0 130.0 ft2 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds Exteriors 2 SW 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft' 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 SE 6 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 it' 9 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 4 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 5 SE 2 Vinyl Low-E Double Yes 0.33 0.21 N 16.2 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 6 SE 6 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft' 9 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 7 NE 3 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 W 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 NW 7 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 k' 11 115 in 0 ft 6 in Drapes/blinds Exterior 5 9 NW 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 10 NW 7 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 11 It 6 in 0 It 6 in Dapes/blinds Exteriors GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 396 ft2 396 ft2 64 ft Sit 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2123.3 116.57 219.22 .1685 7 3/18t202O 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 'FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heal Pump/ Split HSPF:8.2 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SeWnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS / —Supply— V # Location R-Value Area --Return Air Location Area Leakage Type Handler CFM 25 TOT CFM25 OUT ON RLF HVAC# Heat Cool 1 Attic 6 364 ft' Main 91 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablee ]Thermostar[t:,JY [[ ]] Heating ( Jan l l Feb [)n Mar Venting [ 1 Jan I 1 Feb [[X�l Mar Cr[eiling Fans: [[ ]] [[ ]] Apr [ May lMayxl Jun [X] Jul [X] Aug Jun [[ l) Jul [( 11 Aug [X] [ I Sep [ I Sep [ ] L 1 lXl Oct tt Nov[jX]INovrX�] (1(] Nov Dec [ ]DDec ec Thermostat Schedule: HERS 2005 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) AM 66 PM 68 Heating(WEH) AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main 3/18/202U 11:28 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 90 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: CapaciTy 35.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1820 d) Room unit/PTAC EER e) Other 7. Windows, Type and area a) U-factor:(weighted average) 7a. 0.346 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.269 14. Heating system: Capacity 34.6 c) Area 7c. 237.2 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF B. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 13.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: �' Date: Address of New Home: 5365 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951 3/18/2020 11:28:16 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1